Laserfiche WebLink
List Of Abbreviations <br />A <br />A/C <br />AIR CONDITION <br />E <br />EL <br />ELEVATION <br />L <br />LAV <br />LAVATORY <br />S <br />SC <br />SOLID CORE <br />AB <br />ANCHOR BOLT <br />ELEC <br />ELECTRICAL <br />LBL <br />LABEL <br />SCHED <br />SCHEDULE <br />ACT <br />ACOUSTICAL CEILING TILE <br />ELEV <br />ELEVATOR <br />LBS <br />POUNDS <br />SCP <br />SCUPPER <br />AD <br />ADJUSTABLE, ADJACENT <br />EMER <br />EMERGENCY <br />LF <br />LINEAR FEET <br />SD <br />SOAP DISPENSER <br />AFF <br />ABOVE REF FINISHED <br />EQ <br />EQUAL <br />LT WT <br />LIGHT WEIGHT <br />SEAL <br />SEALANT <br />FLOOR (SLAB) <br />EQUIP <br />EQUIPMENT <br />SECT <br />SECTION <br />AHU <br />AIR HANDLER UNIT <br />ESC <br />ESCALATOR <br />M <br />MAS <br />MASONRY <br />SF <br />SQUARE FEET <br />ALT <br />ALTERNATE <br />EWC <br />ELECTRIC <br />MAX <br />MAXIMUM <br />SHT <br />SHEET <br />ALUM <br />ALUMINUM <br />WATER COOLER <br />MECH <br />MECHANICAL <br />SIM <br />SIMILAR <br />ANOD <br />ANODIZED <br />EXIST <br />EXISTING <br />MFR <br />MANUFACTURER <br />SPEC <br />SPECIFICATION <br />APPROX APPROXIMATE <br />EXP <br />EXPANSION <br />MH <br />MANHOLE <br />SS <br />STAINLESS STEEL, <br />ARCH <br />ARCHITECT <br />EXT <br />EXTERIOR <br />MIN <br />MINIMUM <br />SERVICE SINK <br />AUTO <br />AUTOMATIC <br />MIN <br />MINIMUM, MINUTE <br />STD <br />STANDARD <br />F <br />FACP <br />FIRE ALARM <br />MISC <br />MISCELLANEOUS <br />STL <br />STEEL <br />B <br />B 0 <br />BOTTOM OF <br />CONTROL PANEL <br />MLDG <br />MOLDING <br />STOR <br />STORAGE <br />BD <br />BOARD <br />FD <br />FLOOR DRAIN <br />MO <br />MASONRY OPENING <br />STRUC <br />STRUCTURAL <br />BLDG <br />BUILDING <br />FDN <br />FOUNDATION <br />MR <br />MOISTURE RESISTANT <br />SUSP <br />SUSPENDED <br />BM <br />BEAM <br />FIN <br />FINISHED <br />MTD <br />MOUNTED <br />SY <br />SQUARE YARD <br />BRG <br />BEARING <br />FLR <br />FLOOR <br />MTL <br />METAL <br />BTM <br />BOTTOM <br />FR <br />FIRE RESISTANT <br />MUL <br />MULLION <br />T <br />T <br />TREAD <br />BUR <br />BUILT UP ROOF <br />FR-S <br />FIRE -RETARDANT <br />T&G <br />TONGUE & GROOVE <br />WOOD TREATMENT <br />N <br />NIC <br />NOT IN CONTRACT <br />TBL <br />TABLE <br />C <br />CB <br />CATCH BASIN <br />FT <br />FEET, FOOT <br />NOM <br />NOMINAL <br />TELE <br />TELEPHONE <br />CG <br />CORNER GUARD <br />FTG <br />FOOTING <br />NTS <br />NOT TO SCALE <br />TEMP <br />TEMPERED <br />CI <br />CAST IRON <br />FURR <br />FURRING <br />THK <br />THICK <br />CJ <br />CONTROL JOINT <br />FLIT <br />FUTURE <br />0 <br />OC <br />ON CENTER <br />TLT <br />TOILET <br />CL <br />CENTER LINE <br />OD <br />OUTSIDE DIAMETER <br />TO <br />TOP OF <br />CLG <br />CEILING <br />G <br />GA <br />GAUGE <br />OPP <br />OPPOSITE <br />TPD <br />TOILET PAPER <br />CLO <br />CLOSET <br />GAL <br />GALLON <br />OVFL <br />OVERFLOW <br />DISPENSER <br />CLR <br />CLEAR <br />GALV <br />GALVANIZED <br />TS <br />TUBE STEEL <br />CMU <br />CONCRETE <br />GB <br />GRAB BAR <br />P <br />PL <br />PLATE <br />TV <br />TELEVISION <br />MASONRY UNIT <br />GC <br />GENERAL CONTRACTOR <br />PLAM <br />PLASTIC LAMINATE <br />TYP <br />TYPICAL <br />CO <br />CLEAN OUT <br />GYP <br />GYPSUM <br />PLAS <br />PLASTER <br />COL <br />COLUMN <br />PLBG <br />PLUMBING <br />U <br />UON <br />UNLESS OTHER- <br />CONC <br />CONCRETE <br />H <br />HB <br />HOSE BIBB <br />PLWD <br />PLYWOOD <br />WISE NOTED <br />CONST <br />CONSTRUCTION <br />HC <br />HOLLOW CORE <br />PNL <br />PANEL <br />UTIL <br />UTILITY <br />CONT <br />CONTINUOUS <br />HDW <br />HARDWARE <br />PR <br />PAIR <br />CONTR <br />CONTRACTOR <br />HM <br />HOLLOW METAL <br />PREFAB <br />PREFABRICATED <br />V <br />VB <br />VINYL BASE <br />CORR <br />CORRIDOR <br />HORIZ <br />HORIZONTAL <br />PT <br />POINT <br />VCT <br />VINYL COMPOSITE TILE <br />CT <br />CERAMIC TILE <br />HR <br />HOUR <br />PT <br />PRESSURE TREATED <br />VERT <br />VERTICAL <br />CTR <br />CENTER <br />HT <br />HEIGHT <br />PTD <br />PAPER TOWEL DISPENSER <br />VEST <br />VESTIBULE <br />CU <br />CONDENSING UNIT <br />HTG <br />HEATING <br />PVC <br />POLY VINYL CLORIDE <br />VIF <br />VERIFY IN FIELD <br />CW <br />COLD WATER <br />HVAC <br />HEATING, VENTILATING <br />VTR <br />VENT THRU ROOF <br />& AIR CONDITIONING <br />Q <br />QT <br />QUARRY TILE <br />VN1C <br />VINYL WALL COVERING <br />D <br />DBL <br />DOUBLE <br />HW <br />HOT WATER <br />DEPT <br />DEPARTMENT <br />R <br />R <br />RADIUS, RISER, <br />W <br />W <br />WIDTH <br />DET <br />DETAIL <br />I <br />ID <br />INSIDE DIAMETER <br />THERMAL RESISTANCE <br />W/ <br />WITH <br />DF <br />DRINKING FOUNTAIN <br />IN <br />INCH <br />RD <br />ROOF DRAIN <br />W/O <br />WITHOUT <br />DIA <br />DIAMETER <br />INCL <br />INCLUDING <br />RECP <br />RECEPTACLE <br />WC <br />WATER CLOSET <br />DIM <br />DIMENSION <br />INSUL <br />INSULATION <br />REF <br />REFERENCE <br />WD <br />WOOD <br />DISP <br />DISPENSER <br />INT <br />INTERIOR <br />REFR <br />REFRIGERATOR <br />WH <br />WATER HEATER <br />DN <br />DOWN <br />INV <br />INVERT <br />REG <br />REGLET <br />WP <br />WATERPROOF <br />DS <br />DOWNSPOUT <br />REINF <br />REINFORCEMENT <br />WT <br />WEIGHT <br />DWG <br />DRAWING <br />J <br />JAN <br />JANITOR <br />REQ <br />REQUIRED <br />WWF <br />WELDED WIRE FABRIC <br />JB <br />JUNCTION BOX <br />REV <br />REVISION <br />WWM <br />WELDED WIRE METAL <br />E <br />EA <br />EACH <br />JT <br />JOINT <br />RM <br />ROOM <br />EB <br />EXPANSION BOLT <br />RND <br />ROUND <br />Y <br />YD <br />YARD <br />EIFS <br />EXTERIOR INSULATING <br />L <br />L <br />LENGTH <br />RO <br />ROUGH OPENING <br />FINISH SYSTEM <br />LAM <br />LAMINATE <br />RTU <br />ROOF TOP UNIT <br />EJ <br />EXPANSION JOINT <br />Legend <br />X -- GRID DESIGNATION <br />102 ROOM NUMBER <br />102A DOOR NUMBER <br />OWINDOW TYPE <br />® STOREFRONT TYPE <br />WALL TYPE <br />0 KEY NOTE <br />© REVISION NUMBER <br />TO SOMETHING XX'-XX° ELEVATIONS TAGS <br />SPOT ELEVATION TAG <br />• <br />N NORTH ARROW <br />BUILDING SECTION <br />A301-2 A301-2 <br />SHEET NUMBER SECTION NUMBER <br />WALL SECTION <br />A30�2� <br />SHEET NUMBER SECTION NUMBER <br />A501-6 SECTION DETAIL <br />SHEET NUMBER DETAIL NUMBER <br />A888-88 DETAIL REFERENCE <br />SHEET NUMBER DETAIL NUMBER <br />EXTERIOR ELEVATION <br />A201-2 MARKERS <br />� : ;% <br />SHEET NUMBER ELEVATION NUMBER <br />1 <br />INTERIOR ELEVATION <br />4 A401 "' 2 MARKERS <br />SHEET NUMBER 3 ELEVATION NUMBER <br />BRICK <br />. ° ! ° ! CONCRETE <br />PLYWOOD <br />GYPSUM <br />BOARD <br />WO <br />09 <br />DRAINAGE <br />FILL <br />MASONRY <br />��/���/� ECOMPAARTH CTED <br />STEEL <br />GID <br />INSULATION <br />MR <br />BOARD <br />General Notes <br />1. ALL WORK WILL COMPLY WITH LOCAL, STATE, AND NATIONAL CODES <br />8. THE CONTRACTOR SHALL HAVE INSTALLATION INSTRUCTIONS FOR ALL <br />RELATED TO THIS PROJECT. <br />EQUIPMENT AND APPLIANCES ON SITE AT TIME OF INSPECTION. <br />2. THE WRITTEN DIMENSIONS PREVAIL ON THE CONSTRUCTION DOCUMENTS, <br />9. BOTH BUILDINGS D & F SHALL BE FULLY SPRINKLERED. CONTRACTOR TO SUBMIT SIGNED <br />DO NOT SCALE THESE DRAWINGS. CONTRACTOR TO VERIFY ALL DIMENSIONS <br />AND SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE ARCHITECT FOR <br />AND CONDITIONS IN THE FIELD. IF ANY DISCREPANCY OCCURS, THE <br />REVIEW AS WELL AS LOCAL JURISDICTION FOR PERMITTING. NO CONSTRUCTION OF THE <br />CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT IN WRITING BEFORE <br />FIRE PROTECTION SYSTEM SHALL TAKE PLACE UNTIL THE APPROPRIATE PERMITS ARE <br />PROCEEDING WITH ANY WORK AFFECTED BY THE DISCREPANCY. <br />OBTAINED BY THE FIRE PROTECTION SUB CONTRACTOR <br />3. CONTRACTORS TO SECURE ALL PERMITS AND REQUIRED INSPECTIONS <br />10. CONTRACTOR SHALL PROVIDE FLORIDA PRODUCT APPROVAL SUBMITTALS FOR THE <br />NECESSARY TO OBTAIN A CERIFICATE OF OCCUPANCY. <br />FOLLOWING BUILDING COMPONENTS THAT COMPLY WITH RULE 96-72: <br />a. EXTERIOR HOLLOW METAL DOORS <br />4. CONTRACTORS ARE TO PROVIDE ALL TEMPORARY UTILITIES AND <br />b. STORE FRONT SYSTEMS (WIND VELOCITY =130 MPH) <br />INFRASTRUCTURE REQUIRED TO PERFORM THE WORK, INCLUDING <br />c. ROOFING AND COPING (CONFIRMING TO FM 1-120 REQUIREMENTS) <br />FIRE PROTECTION AS REQUIRED DURING CONSTRUCTION. <br />d. CLADDINGS (LAPPED SIDING) <br />LCONTRACTOR TO PROVIDE THREE COPIES FOR REVIEW AND SUBMITTAL TO <br />5. EACH CONTRACTOR AND SUBCONTRACTOR IS EXPECTED TO REVIEW ALL <br />THE LOCAL JURISDICTION AND PRODUCT SUBMITTAL FOR ARCHITECTS <br />CONTRACT DOCUMENTS AND SITE CONDITIONS PRIOR TO ISSUED BID. <br />REVIEW. <br />CHANGE ORDERS WILL NOT BE APPROVED FOR FAILURE TO DO SO. <br />11. ALL PLYWOOD SHEATHING TO BE FIRE RETARDANT TREATED (FRT) <br />6. PRODUCTS SPECIFIED OR OTHERWISE INDICATED IN THE CONTRACT <br />DOCUMENTS SHALL NOT BE SUBSTITUED WITHOUT PRIOR WRITTEN <br />12. SEE "PUBLIX CANOPY PACKAGE" DRAWINGS FOR DETAILS KEYED WITH PREFEX "PCA-" <br />APPROVAL FROM THE ARCHITECT. <br />13. SEE STRUCTRUAL DRAWINGS FOR SOILS REPORT INFORMATION <br />7. THIS CONTRACTOR SHALL COORDINATE ALL TRADES REQUIRED TO <br />COMPLETE THIS PROJECT AS REQUIRED TO ACTIVATE THE USE OF THE <br />14. SEE ENERGY CALCULATION ATTACHED TO THIS SUBMISSION <br />FACILITY AS PLANNED. <br />Legal Description <br />A TRACT OF LAND LYING IN THE NORTHEAST %4 OF SECTION 34 AND IN THE NORTHWEST %4 OF SECTION <br />35, TOWNSHIP 25 SOUTH, RANGE 21 EAST, PASCO COUNTY, FLORIDA. THE SAME BEING A PORTION OF <br />THE ZEPHYRHILLS COLONY COMPANT LANDS SUBDIVISION OF SAID SECTION 34 AND 35 AS SHOWN <br />ON THE PLAT OR MAP THEREOF RECORDED IN PLAT BOOK 1, PAGE 55 OF THE PUBLIC RECORDS OF <br />PASCO COUNTY, FLORIDA. ALL BEING FURTHER DESCRIBED AS FOLLOWS: FOR A POINT OF <br />REFERENCE COMMENCE AT THE SOUTHEAST CORNER OF THE NORTHWEST y OF SAID SECTION 35; <br />THENCE N. 89 53'13"W., ALONG THE SOUTH BOUNDARY THEREOF, A DISTANCE OF 1638.79 FEET; <br />THENCE N. 00 09'45" W., A DISTANCE OF 657.26 FEET TO THE INTERSECTION OF THE EASTERLY <br />RIGHT-OF-WAY LINE OF U.S. HIGHWAY 301; THENCE NORTHERLY, ALONG SAID EASTERLY <br />RIGHT-OF-WAY LINE, THE FOLLOWING FOUR COURSES; (2) S. 89 46'32" E., A DISTANCE OF 5.00 FEET; (4) <br />NORHTERLY, 625.74 FEET ALONG THE ARC OF A CURVE TO THE RIGHT (SAID CURVE HAVING A <br />RADIUS OF 625.73 FEET) TO A POINT LYING ON THE NORTH BOUNDARY OF SAID SECTION 34; THENCE <br />S. 89 58'32" SECTION 34 ALSO BEING THE NORTHWEST CORNER OF SAID SECTION 35; THENCE S. 89 <br />59'50" E., ALONG THE NORTH BOUNDARY OF SAID SECTION 35, A DISTANCE OF 1015.05 FEET; THENCE <br />S. 00 09'45" W., A DISTANCE OF 2618.58 FEET TO THE POINT OF BEGINNING. <br />LESS AND EXCEPT THAT PORTION OF SAID TRACTS 58 AND 59 CONVEYED IN OFFICIAL RECORDS <br />BOOK 1902, PAGE 690, PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br />SAID LAND CONTAINING 60.76 ACRES MORE OR LESS. <br />Vicinity MapNTS <br />i Ij <br />in <br />... <br />KOSSIK RD cn <br />' <br />PROJECT <br />SITE I <br />ROAD 54 { <br />INTERSECTION OF KOSSIK & US HWY 301 (GALL BLVD) <br />Scope of Work <br />ZEPHYR COMMONS CONSISTS OF NEW SITE CONSTRUCTION AND THE NEW CONSTRUCTION OF SEVERAL BUILDINGS. <br />THE SCOPE OF WORK IN THIS SET OF DRAWINGS IS FOR RETAIL BUILDINGS D AND F ONLY. THE SITE WORK AND THE <br />OTHER BUILDINGS WILL BE DESIGNED, PERMITTED, AND CONSTRUCTED AS SEPARATE DRAWING PACKAGES. <br />Code Information <br />REFER TO A121 AND A122 FOR COMPLETE CODE INFORMATION <br />CITY OF ZEPHYRHILLS THREE (3) SIGNED & SEALED <br />5335 8TH ST SETS FOR PERMIT SUBMISSION <br />ZEPHYRHILLS, FLORIDA 33542 <br />(813) 780-0020 - PHONE <br />(813) 780-0021 - FAX <br />BUILDING: <br />FLORIDA BUILDING CODE, BUILDING - 2004 W/ 2006 SUPPLEMENTALS] <br />FIRE: <br />FLORIDA FIRE PREVENTION CODE - 2004 W/ 2006 SUPPLEMENTALS <br />CHAPTER 36 - (NFPA 1 & NFPA 101 W/ STATE FIRE MARSHAL AMENDMENTS) <br />PLUMBING: <br />FLORIDA BUILDING CODE, PLUMBING - 2004 W/ 2006 SUPPLEMENTALS <br />MECHANICAL: <br />FLORIDA BUILDING CODE, MECHANICAL - 2004 W/ 2006 SUPPLEMENTALS <br />ELECTRICAL: <br />FLORIDA BUILDING CODE, BUILDING - 2004 W/ 2006 SUPPLEMENTALS <br />CHAPTER 27 - (NFPA 70, NATIONAL ELECTRIC CODE) <br />FUEL/GAS: <br />FLORIDA BUILDING CODE, FUEL/GAS - 2004 W/ 2006 SUPPLEMENTALS <br />ACCESSIBILITY: <br />FLORIDA BUILDING CODE, BUILDING - 2004 W/ 2006 SUPPLEMENTALS <br />CHAPTER 11 - (FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION). <br />ENERGY: <br />FLORIDA BUILDING CODE, BUILDING - 2004 W/ 2006 SUPPLEMENTALS <br />CHAPTER 13 - (FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION). <br />BUILDING AND CONSTRUCTION DATA <br />OCCUPANCY CLASSIFICATION (FBC 309) <br />CONSTRUCTION TYPE (FBC TABLE 601) <br />MAXIMUM HEIGHT AND AREA (FBC TABLE 503) <br />*THE PUBLIX AND ADJACENT RETAIL <br />BUILDINGS ARE CLASSIFIED AS UNLIMITED <br />AREA AS ALLOWED BY FBC 507 <br />Contact Information <br />AND <br />E� Rjt-:5 <br />0;0j.;f­_y INIP~- : sYRBiN ILLS <br />REVIEW DAYS;: --Al& <br />CITE' OF : EPHy I <br />GROUPS M - MERCANTILE <br />TYPE II-B, NEW CONSTRUCTION, SPRINKLERED` <br />HEIGHT - 55'-0" AREA-12,500 SF* �� l <br />ACTUAL HEIGHT = 30' -0" (SINGLE STORY) <br />ACTUAL AREA PUBLIX 54 = 54,817 SF <br />RETAIL D = 8,600 SF��'��`�Ktl <br />RETAIL F = 9,200 SF S u"_fT �'1 r' <br />TOTAL SF = 72,617 SF <br />ti 0i4 c_f <br />CLIENT: <br />PRIMERICA GROUP ONE, INC. <br />STRUCTURAL <br />BURTON BRASWELL MIDDLEBROOKS ASSOCIATES, INC <br />3629 MADACA LANE <br />ENGINEER: <br />1912 BOOTHE CIRCLE SUITE 100 <br />TAMPA, FL. 33618 <br />LONGWOOD, FLORIDA 32750 <br />(813) 933-0629 PHONE <br />(407) 645-3423 <br />(813) 935-3420 FAX <br />(407) 645-3790 FAX <br />CONTACT: STEVE FACIONE <br />CONTACT: BORA ERBILEN, P.E., MBA <br />ARCHITECT: <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />MECHANICAL <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />1925 PROSPECT AVE <br />ENGINEER: <br />1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />(407) 661-9101 FAX <br />CONTACT: GABRIEL ROBERTSON <br />CONTACT: JOE KEENE <br />CIVIL <br />AVID GROUP <br />ELECTRICAL <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />ENGINEER: <br />8659 BAYPINE ROAD, STE 304 <br />ENGINEER: <br />1925 PROSPECT AVE <br />JACKSONVILLE, FLORIDA 32256 <br />ORLANDO, FL 32814 <br />(904) 737-4001 PHONE <br />(407) 661-9100 PHONE <br />(904) 252-7030 FAX <br />(407) 661-9101 FAX <br />CONTACT: TAMARA D. SCHURIAN, P.E. <br />CONTACT: TIM CONWAY <br />SHEET NO. <br />ARCHITECTURAL <br />A100 <br />A101 <br />A121 <br />A122 <br />A131 <br />A132 <br />A141 <br />A142 <br />A201 <br />A202 <br />A301 <br />A302 <br />A501 <br />A502 <br />A601 <br />A001-AO09 <br />STRUCTURAL <br />PLUM, & FP <br />MPF-1 <br />FIRE PROTECTIO <br />FP001 <br />FP101D <br />FP101F <br />PLUMBING <br />P001 <br />P101D <br />P101F <br />MECHANICAL <br />M001 <br />M101D <br />M101F <br />ELECTRICAL <br />Zephyr Commons <br />Gall Blvd. & Kossik Road <br />Ll <br />ZPyehrhills, Florida <br />SIGN <br />ORION 00101 <br />Retail D <br />Retail F <br />Drawing Index <br />10-03-07 <br />11-28-07 <br />01-07-08 <br />1ST PUBLIX <br />2ND PUBLIX <br />PERMIT <br />SHEET TITLE <br />SUBMISSION <br />SUBMISSION <br />SUBMISSION <br />GENERAL STRUCTURAL NOTES <br />GENERAL STRUCTURAL NOTES <br />GENERAL STRUCTURAL NOTES <br />FOUNDATION PLAN - RETAIL "D" <br />FOUNDATION PLAN - RETAIL I" <br />ROOF FRAMING PLAN - RETAIL "D" <br />ROOF FRAMING PLAN - RETAIL "F" <br />FOUNDATION SECTIONS AND DETAILS <br />GENERAL STRUCTURAL NOTES <br />GENERAL STRUCTURAL NOTES <br />H11 <br />SIGN <br />—lij, 1V W <br />the, app lble <br />.. 1 A. & Lhe City Of Zephyrhills <br />y FirC Marshal of Zehrhills <br />with co nts provided -i plans) <br />t <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />FP & P SITE COORDINATION PLAN X X X <br />=dl I I I <br />El = __1 -A <br />N SEE GENERAL NOTE #9 <br />FIRE PROTECTION NOTES SCHEDULES & DETAILS X X X <br />FIRE PROTECTION FLOOR PLAN - RETAIL D X X X <br />FIRE PROTECTION FLOOR PLAN - RETAIL F X X X <br />PLUMBING NOTES SCHEDULES & DETAILS X X X <br />PLUMBING FLOOR PLAN - RETAIL D X X X <br />PLUMBING FLOOR PLAN - RETAIL F X X X <br />MECH. NOTES SCHEDULES & DETAILS X X X <br />MECH. ROOF PLAN - RETAIL D X X X <br />MECH. ROOF PLAN - RETAIL F X X X <br />C/!I <br />E <br />U <br />M 00 <br />No <br />o <br />o <br />U- <br />o <br />� <br />Z rn <br />Of <br />o'IT <br />w <br />�� <br />wCP <br />� CP <br />0 CD <br />CDr. <br />v <br />N= <br />N <br />> M <br />ot�.. <br />w <br />J O� <br />m� <br />w <br />.a <br />> <br />�i <br />O <br />4-3 <br />N <br />� <br />N <br />M <br />O <br />N <br />