My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7810 and 7850 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7810 and 7850 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 4:42:30 AM
Creation date
2/19/2025 11:48:39 AM
Metadata
Fields
Template:
Building Plans
Street #
7810 and 7850
Location
Gall Blvd
Contractor
Hawkins Construction
Building Plans - Permit #
8060 and 8061
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N S <br />CONT. S.S. CLIP ATT. TO NAILERS @ 6" O.C. O <br />W/ S.S. SCREWS <br />GALV. STL. CAP u CANOPY ROOF SYSTEM TO MATCH PUBLIX <br />.045 EPDM MEMBRANE <br />6" DIA SCH 40 PIPE (GALV. STEEL) P.T. 2X6 NAILERS: ATT. TO CONC. T.B. @ 48" ROOF P-+ <br />STAINLESS STL. CAP FILLED W/ CONCRETE (LENGTH = 8'-8") CONT. S.S. CLIP ATT. TO NAILERS @ 6" , N <br />O.C. W/Y" DIA. BOLTS MIN. EMBEDMENT: 4" v� a <br />6"I DIA SCH <br />W/ 4000NCRETEPIP(STAINLESS <br />ST8EE8L) _ Oo 0 15" MAX OCW/S.S. SCREWS " <br />o o O S.S. SCREWS W/ NEOPRENE WASHERS @ 6" G) o <br />(LENGTH - ) o SLOPE Y PER FT. MIN. S.S. PARAPET CAP W/ MIN. 4 BACKING <br />PAVING o� O.C. - HORIZ. SLOTTED HOLES IN FLASHING PLATE @ JOINTS EXTEND UP & UNDER BASE . <br />4 �o <br />xi d <br />PAVING ` o LEG FLASHING MIN. 8"LAP <br />bq Go <br />%" "HAT SECTION" GALV. FURRING 24, O.C. w <br />@ RE: STRUCTURAL FOR ROOF FRAMING INFO <br />`\ ATT. TO CONC. BLK. @ 8' O.C. W > o <br />�1 2'-0" DIA CONC. FTG. ` METAL FLASHING P.T. 2X6 NAILERS: ATT. TO CONC. T.B. @ 48" <br />2'-0" DIA CONC. FTG. - CLAMPING RING S.S. PARAPET CAP W/ MIN. 4" PACKING p W/ "DIA EXP. BOLTS M EMBEDMENT <br />CORNICPLATEE MOLDING RE: ELEVATIONS ,;C z IN. o <br />OINTS <br />STRAINER 4 SLOPE TOP 1 PER FT. MIN. U o <br />\ \ \ BULDING FINISH RE: ELEVATIONS CONT. S.S. GUTTER EXTEND UP & UNDER <br />\ \ FLASHING MIN. 4 LAP <br />\\ \� MASONRY WALL RE: PUBLIX DWGS a s <br />EXTEND BASE FLASHING BEHIND GUTTER U <br />DETAILS ARE SIM. FOR ALL PARAPET <br />ROOF DRAIN 6'-0" „ <br />TURN: Z100-85 0R EQUAL CONDITIONS. WHERE EXTERIOR FINISH IS Y DIA. ANCHOR @ ROLLOVER STRAP Q' <br />�\ \�\ : �; .' , \ j\\ \ N \\\/\ •� \\�\ \ - DECK CLAMP NOT PRESENT REPOSITION NAILERS AS <br />\\\\\ \\ \\\\ \\/\ o \\\\ \\/\\ " '. ' :., \\j\� \\\\ `' TAPER INSULATION 24" DOWN TO REQUIRED. <br />� :'• \/\\��\\ E: PUBLIX DWGS. <br />PRIMARY ROOF DRAIN FASTENER SPACING MAY BE INCREASED S.S. DOWNSPOU ONRY WALLTTO CONC. SPASHBLOCK <br />\\ \\� \/ . •'`w \/\\\ \/\ \ /\ \� OVERFLOW DRAIN SIM. TO PRIMARY WHERE ALLOWED BY WIND CLASSIFICATION S.S. REGLET ATT, TO WALL W/ S.S. SCRWS @ <br />\�\ \ DRAIN EXCEPT OVERFLOR DRAIN TO 1 ALUM. SIDING ATT. TO FURRING @ 8 O.C. NEOPRENE WASHERS @ 8" O.C. <br />BE 2" MIN - 4" MAX ABOVE PRIMARY HORIZ. & 24" O.C. VERT. W/ S.S. SCREWS 2 PIECE SNAP -IN S.S. COUNTER FLASHING <br />j \ \ (COVER W/ SEALANT) <br />SYSTEM CONCURRENT W/ THE PLY SHEET <br />S.S. REGLET ATT. TO WALL W/ S.S. SCRWS @ FLASHING SYSTEM INSTALLATION =' <br />NEOPRENE WASHERS @ 8" O.C. _ SET BASE FLASHING IN COLD APPLIED <br />Front Bollard Detail ,'-o" ,'-0" 2 Rear & Side Bollard Detail 1'-0" 1'-0" Roof Drain Detail - 2 PIECE SNAP -IN S.S. COUNTER FLASHING MODIFIED BITUMEN ROOF CEMENT EXTEND <br />1 SCALE: Y" =1'-0" SCALE: Y" =1'-0'. 3 SCALE: N.T.S. SYSTEM CONCURRENT W/ THE PLY SHEET MIN. 4" ABOVE CANT (18" MAX HT) <br />FLASHING SYSTEM INSTALLATION CONT. 4" FIBER OR PERLITE CANT STRIP <br />SET BASE FLASHING IN COLD APPLIED CANOPY ROOF SYSTEM TO MATCH PUBLIX <br />MODIFIED BITUMEN ROOF CEMENT EXTEND ROOF RE: ROOF PLANS FOR SLOPE <br />MIN. 4" ABOVE CANT (18" MAX HT) INFORMATION <br />DETAILS ARE SIMILAR FOR ALL PARAPET <br />1"ALUM. SIDING ATT. TO FURRING @ 8" O.C. HORIZ. — CONT. 4" FIBER OR PERLITE CANT STRIP RE: STRUCTURAL FOR ROOF FRAMING INFO <br />CONDITIONS. WHERE EXTERIOR FINISH IS NOT & 24" O.C. VERT. W/ S.S. SCREWS (COVER W/ PUBLIX ROOF SYSTEM, RE: PUBLIX DWGS <br />PRESENT REPOSITION NAILERS AS REQUIRED, SEALANT) FOR CONSTRUCTION AND SLOPE <br />S.S. REGLET ATT. TO WALL W/ S.S. SCRWS @ INFORMATION <br />NEOPRENE WASHERS @ 8" O.C. <br />FASTENER SPACING MAY BE INCREASED WHERE <br />ALLOWED BY WIND CLASSIFICATION 2 PIECE SNAP -IN S.S. COUNTER <br />FLASHING SYSTEM CONCURRENT W/ <br />THE PLY SHEET FLASHING SYSTEM <br />CONT. S.S. CLIP ATT, TO NAILERS @ 6" O.C. W/ S.S. = INSTALLATION <br />SCREWS <br />SET BASE FLASHING IN COLD APPLIED MODIFIED <br />045 EPDM MEMBRANE BITUMEN ROOF CEMENT EXTEND MIN. 4" ABOVE 4 MTL. Panel Roof Detail 5 Gutter & Downspout Detail <br />15" MAX P.T. 2X6 NAILERS: ATT. TO CONC. T.B. @ 48" O.C. W/ CANT (18" MAX HT) CEILING ACCESS HATCH SCALE: N.T.S. SCALE: N.T.S. <br />SLOPE Y" PER FT. MIN. Yz" DIA. BOLTS MIN. EMBEDMENT: 4" CONT. 4" FIBER OR PERLITE CANT STRIP 6" MTL STUD FRAMING @ 24" O.C. TYP. <br />CANOPY ROOF SYSTEM TO MATCH PUBLIX ROOF STL SUPPORT RE: STRUCTURAL <br />S.S. SCREWS W/ NEOPRENE WASHERS @ 6" O.C. - RE: ROOF PLANS FOR SLOPE INFORMATION SOFFIT CEILING SYSTEM <br />_ HORIZ. SLOTTED HOLES IN FLASHING LEG RE: STRUCTURAL FOR ROOF FRAMING INFO RE: REFLECTED CEILING PLAN Q� <br />%" "HAT SECTION" GALV. FURRING @ 24' O.C. ATT. <br />TO CONC. BILK. @ 8" O.C. %" GYP. BD. O <br />MTL STUD FRAMED WALL RE: <br />S.S. PARAPET CAP W/ MIN. 4" PACKING PLATE @ a„ PLANSNVALL TYPE DETAILS <br />8 Access Hatch Detail 6 MTL STUD FRAMED WALL RE: PLANS RAIN LEADER FROM ABOVE <br />JOINTS SCALE: N.T.S. <br />e" DENSGLASS SHEATHING R-11 BATT INSULATION O <br />RE: CIVIL FOR CONNECTION <br />BUILDING FINISH RE: ELEVATIONS C <br />MTL. STUD FRAMING RE: STRUCTURAL v <br />1"ALUM. SIDING ATT. TO FURRING @ 8" O.C. HORIZ. 7SCALE: <br />Cant Strip Detail 3,�„ s� n� °° <br />& 24 O.C. VERT. W/ S.S. SCREWS COVER W/ +' 3�( N.T.S. � (.) � co <br />SEALANT)FL <br />Y' <br />S.S. REGLET ATT. TO WALL W/ S.S. SCRWS @ J <br />NEOPRENE WASHERS @ 8" O.C.LLJ = - CmCU <br />2 PIECE SNAP -IN S.S. COUNTER 8 CMU RE: SECTIONS 12" PUBLIX CMU WALL RE: PUBLIX PLANS N �_, .r,. :'-: � : _:�:� ., Y„ :: =;.; .-.: •: a: ,pUb,�r_ u d- .L Q- <br />FLASHING SYSTEM CONCURRENT W/ STONE VENEER SYSTEM PER 1" EXPANSION JOINT <br />_ THE PLY SHEET FLASHING SYSTEM w M H U) <br />MANUF.INSTALLATION 6 MTL STUD FRAMED WALL RE: PLANS 8" CMU RE: SECTIONS <br />INSTALLATION INSTRUCTIONS R-11 BATT INSULATION `= = U <br />ya. <br />STONE VENEER SYSTEM PER WALL FINISH RE: PLAN <br />SET BASE FLASHING IN COLD APPLIED MODIFIED MANUF.INSTALLATION SHEET MTL. REGLET EMBEDDED <br />BITUMEN ROOF CEMENT EXTEND MIN. 4" ABOVE _ -- - - <br />INSTRUCTIONS BEHIND WALL CLADDING <br />CANT (18" MAX HT) <br />• BUILDING PAPER <br />CONT. 4" FIBER OR PERLITE CANT STRIP <br />_ 1n 3'4' 8" CMU RE: SECTIONS FASTENERS 24" O.C. <br />ER <br />CANOPY ROOF SYSTEM TO MATCH PUBLIX ROOF _ o LL 3X(76mLm) LAP (MIN.) W/ BEAD OF SEALANT <br />STONE VENEER SYSTEM PER <br />RE: ROOF PLANS FOR SLOPE INFORMATION 8 <br />RE: STRUCTURAL FOR ROOF FRAMING INFO MANUF.INSTALLATION 24 GAUGE SHEET MTL. COUNTERFLASHING <br />N o -��, rt' INSTRUCTIONS f OPTIONAL 2" WIDE CLIP 30" O.C. <br />> > L? <: MEMBRANE BASE FLASHING o <br />°° °° 11 Enlarged Plan Detail 12 Enlarged Plan Detail <br />:r SCALE: %" =1'-0" SCALE: %" =1'-0" �� IL <br />U <br />< �. <br />^F <br />0 <br />.........._. ......................... g <br />6MTL. Panel Roof Detail `7 r� <br />SCALE: N.T.S. BUILDING D _ — <br />2' 6° 8" CMU RE: SECTIONS Q <br />n n <br />UILDING F STONE VENEER SYSTEM PER <br />MANUF.INSTALLATION a w <br />8" CMU WALL RE:PLANS <br />STUCCO FINISH SYSTEM <br />INSTRUCTIONS I Cl)(� <br />06 <br />9 Enlarged Plan Detail 10 Enlarged Plan Detail <br />SCALE: %" =,'-o" SCALE: 3/a" =1'-0" 13SCALE:Flashinq Detail Cn N.T. � � z <br />Q Q <br />PUB CL 1 U <br />- L <br />8" CMU WALL RE:PLANS 6X6 STEEL COLUMN 4'-0" 0 <br />STUCCO FINISH SYSTEM PUBLIX RETAIL <br />4 8" CMU RE: SECTIONS RE: STRUCTURAL 5 " <br />STONE VENEER SYSTEM PER GYP. BD. � = J w <br />LL <br />MANUF.INSTALLATION 6 MTL. STUD FRAMED WALL N v <br />R-11 BATT INSULATION vi <br />INSTRUCTIONS , s; �� ��,.�',s_ :ti; y; ti � A � :r � �.� gg — _ <br />...'4J�q,�:':yr.::AF�isvi<tav;2�x:t_S,i.;n`-�A:!'; sp:ys'•; ir^ H :%i U <br />LU <br />PUBLIX MU RE: PUBLIX PLANS $ 0 LL Y N EL = w <br />K �A <br />CONTIN OUS CAST -IN -PLACE a <br />CONCR TE CURB <br />x 10" 2'-6" "' %" DENSGLASS <br />f ?� STUCCO FINISH SYSTEM <br />CMU WALL RE: PUBLIX PLANS N <br />3 INSTALL POLYURETHANE SEALANT & TOOL TO o z <br />'4 FACILITATE WATER RUN-OFF EXPANSION JOINT <br />,3Y s CONT. SEALENT TYPE "A" FLASHING e o <br />TAPCON 12 O.C. TYP. X2 N.T.S. <br />A '® a mod" <br />CONT. S.S. COUNTERFLASHING "A" 8 > LL <br />16SCALE:Enlarged Plan DetailBUTYL TAPE3 "- TAPCON 6" O.C. A <br />op <br />3 / -1-0" <br />lo <br />CONT CLEAT "B" E <br />`�`%%''�'"r4-•}+ �'��'�;y' +>=''r "''"r"•= '"^<''S ''� 8" CMU RE: SECTIONS 1 1/2" X " COMPRESSION FILLER f CONT. COUNTER FLASHING "B" <br />STONE VENEER SYSTEM PER TEMCO "DYMERIC" CONSTRUCTION �v <br />MANUF.INSTALLATION JOINT SEALANT. JOINT SHALL BE 1" <br />INSTRUCTIONS WIDE X %" DEEP. INSTALL A CLOSED EXPANSION JOINT <br />Enlarged Plan Detail 17SCALE:Exansion Joint Detail CELL POLYETHYLENE JOINT BACKING TYPE "B" FLASHING14 Enlarged Plan Detail 15 aged 1" =1'-0" ROD TO CONTROL DEPTH. N.T.S. a a <br />SCALE: %" =1'-0" SCALE: %" =1'-0" —.-- <br />15° CONT. COUNTER FLASHING "C' ATT. TO P.T. 6Y4„ 2 ' <br />2X @ 6" O.C. W/ S.S. SCREWS & NEOPREME � <br />n <br />WASHERS @ 8" O.C. (SLOPE AWAY FROM <br />4'-8" 2'-0° 4'-8" Z-0" WALL) <br />" E ti <br />P.T. 2X NAILER <br />...::: .>, ';.:: > _:t' ;: ..;,::,: ;:;;,:.. EXPANSION JOINT FILLER = c ch <br />TEMCO DYMERIC CONSTRUCTION JOINT 6 MTL. STUD FRAMING 6" <br />SEALANT. JOINT SHALL BE 1 1/2 WIDE x / DEEP. 5 " o <br />s " / DENSGLASS \ 4" FIBER CANT STRIP m c <br />INSTALL A CLOSE CELL POLYETHYLENE JOINT ADJACENT ROOF TO MATCH PUBLIX <br />BACKING ROD TO CONTROL JOINT DEPTH. ?" STUCCO FINISH SYSTEM C n <br />8" CMU RE: STRUCTURAL EXPANSION JOINT = A -0 <br /># _ TYPE "C" FLASHING, C j <br />CV t N <br />N.T.S. x <br />a � <br />O <br />•'f:' : i' 21 Q c I..L <br />�. <br />w vi <br />CAST -IN -PLACE CONC. CURB QQ <br />/ \ �. \ W <br />a <br />m <br />2" X 3" COMPRESSION FILLER _ � # - oo # /, <br />PUBLIX RETAIL <br />8" CMU RE: SECTIONS w o � m Y <br />w � <br />O N O W U <br />STONE VENEER SYSTEM PER a o <br />MANUF.INSTALLATION NOTE: FLASHINGS MIN. 266A EXPANSION JOINT <br />INSTRUCTIONS :, ::;:J: ;;;:,;:>; .;;:_;,. ;';.; <br />Expansion Joint Detail CORROSION RESISTANT MTL. TYPE "B" AT <br />N.T.S. <br />3'-4" 3'�" 3'-4" 31-4" Scale N.T.S. A501 <br />18 Expansion Joint Detail 19 Enlarged Plan Detail 20 Enlarged Plan Detail 21 <br />SCALE: %" = 1'-0" SCALE: %" =1'-0" SCALE: 3/" =1'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.