Laserfiche WebLink
€i <br />HYDRANT <br />-FIRE <br />RE: CIVIL PLANS <br />I Ij <br />;f <br />Bldg B <br />EXISTING BUILDING <br />TO REMAIN AS IS. <br />FIRE HYDRANT <br />�RE: CIVIL PLANS <br />s <br />6 <br />FIRE HYDRANT <br />RE: CIVIL PLANS <br />Bldg C <br />EXISTING BUILDING <br />TO REMAIN AS IS. <br />EXISTING REAR SIDEWALK IS FLUSH <br />WITH ADJACENT PAVEMENT ALONG <br />THE ENTIRE REAR OF BUILDING D <br />f <br />9 <br />-------------- <br />40'-0" <br />40'-4" <br />DIM. FROM <br />DIM. FROM <br />I <br />CMU EXTR. <br />I <br />COLUMN <br />FACE TO <br />CENTER TO <br />COLUMN <br />I <br />COLUMN <br />CENTER. <br />CENTER <br />VEIFY <br />IN FRELD <br />D3-D4 <br />I <br />m <br />FIRE HYDRANT <br />RE: CIVIL PLANS <br />EXISTING BLDG D <br />FIRE RISER ROOM <br />DASHED LINE INDICATES <br />EXTENT OF AREA OF WORK <br />REFER TO SHEET A101 FOR <br />ENLARGED PLANS & LIFE <br />SAFETY INFORMATION <br />FIRE HYDRANT <br />RE: CIVIL PLANS <br />- --.� - <br />_ .. <br />_ - 4 <br />Mr nTUMMNI <br />RE: CIVIL PLANS <br />Bldg E <br />Bldg F �>: <br />EXISTING BUILDING <br />EXISTING BUILDING <br />TO REMAIN AS IS. <br />TO REMAIN AS IS. <br />Elevation & Grading Notes <br />1. ABBREVIATIONS: <br />TOS - TOP OF FLOOR SLAB INSIDE BUILDING <br />TOC - TOP OF CURB AT EDGE OF SIDEWALK <br />TOP - TOP OF PAVING <br />2. EXISTING TOS=113.00'. <br />3. ALL SIDEWALKS ARE EXISTING AND START 1/4" BELOW THE <br />TOS AT ALL DOORS. <br />4. ALL EXTERIOR DOORS ARE EXISTING AND HAVE EXISTING <br />THRESHOLDS THAT DO NOT EXCEED 112" IN HEIGHT. <br />5. ALL SIDEWALKS ARE EXISTING AND SLOPE AWAY FROM THE <br />BUILDING AT A RATE BETWEEN 1 % MIN AND 2% MAX. <br />6. AT ALL FRONT SIDEWALKS, TOC IS 6" MAX ABOVE ADJACENT TOP. <br />7. AT ALL REAR SIDEWALKS, TOC IS FLUSH WITH ADJACENT TOP. <br />8. ALL HANDICAP RAMPS ARE EXISTING AND HAVE A SLOPE OF 1:14 <br />MAX. THE SURFACES OF ALL CURB RAMPS HAVE RAISED <br />DETECTABLE WARNING FINISHES. <br />9. THE BOTTOMS OF ALL HANDICAP RAMPS ARE FLUSH WITH <br />THE ADJACENT TOP <br />10. REFER TO CIVIL DRAWINGS FOR EXACT ELEVATIONS. <br />11. THE CONTRACTOR SHALL FIELD VERIFY ALL SIDEWALK AND <br />GRADING CONDITIONS PRIOR TO STARTING WORK. THE GC <br />SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF ANY OF THE <br />EXISTING CONDITIONS DO NOT MEET ADA REQUIREMENTS. <br />4Nv} <br />Fire Marshal's Checklist <br />EGRESS TRAVEL AND EXITS <br />RE: LIFESAFETY PLAN & CODE INFO ON A101 <br />EXIT AND EMERGENCY LIGHTS <br />RE: LIFESAFETY PLAN ON A101 <br />A FIRE ALARM SYSTEM WILL BE DESIGNED AND PERMITTED BY <br />SMOKE DETECTORS <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A101 <br />FIRE EXTINGUISHERS <br />RE: LIFESAFETY PLAN ON A101 FOR LOCATIONS <br />FIRE RATED WALLS <br />RE: LIFESAFETY PLAN ON A101 FOR LOCATIONS & UL DETAILS <br />ALL DOORS SHALL HAVE HARDWARE THAT COMPLIES WITH <br />PANIC HARDWARE <br />REQUIREMENTS FOR EGRESS AND ADA ACCESSIBILITY. <br />RE: LIFESAFETY PLAN ON A101 FOR DOOR LOCATIONS <br />DUCT DETECTORS SHALL BE PROVIDED AS REQUIRED BY SMACNA, NFPA, <br />DUCT DETECTORS <br />AS WELL AS ANY OTHER APPLICABLE CODE <br />RE: MECHANICAL DRAWINGS FOR HVAC INFORMATION <br />EMERGENCY GENERATOR <br />NONE REQUIRED, NONE PROVIDED. <br />RE: A101 FOR ROOF FINISH INFO & CODE INFORMATION <br />INTERIOR FINISHES <br />FOR FLAME SPREAD RATINGS <br />SITE PLAN SHOWING ADJACENT <br />RE: OVERALL PROJECT SITE PLAN ON A100. FOR COMPLETE SITE <br />ROADWAYS, BUILDINGS, AND <br />FIRE HYDRANTS <br />WORK AND UTILITY INFORMATION, RE: CIVIL DRAWINGS BY AVID. <br />FULL SYSTEM PROVIDED. TO BE DESIGNED AND PERMITTED BY <br />FIRE ALARM <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A101 <br />SPRINKLERS <br />FULL SYSTEM PROVIDED. TO BE DESIGNED AND PERMITTED BY <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A101 <br />GAS USAGE <br />NONE REQUIRED. NONE PROVIDED. <br />Ee <br />O <br />O <br />I <br />�a <br />00 <br />00 <br />d� <br />�o <br />• � <br />o <br />do <br />Uw <br />� <br />5 <br />a�" 8 <br />U <br />o� <br />C � <br />� <br />ON a4 <br />U <br />C <br />N <br />C <br />0 <br />CL <br />O <br />�w <br />cuz00 <br />cc (CD") <br />—UM <br />�0LL <br />ul QQ <br />m .E�a <br />�N� <br />w ��< <br />U <br />yr <br />C <br />O <br />E <br />E <br />O <br />U <br />0- <br />CD , <br />NO <br />-6..po <br />CU <br />�m <br />�Q <br />CM <br />J <br />CU 0° <br />:<^j w <br />♦♦ <br />VJJ <br />O J <br />}+ (0 — <br />r-1 co <br />�06>- <br />F- <br />U <br />(0 = <br />�tiN <br />d <br />w <br />Cl) <br />w <br />a <br />0 <br />w <br />Q <br />o <br />u1 <br />C14 <br />J <br />W <br />N <br />o <br />� <br />a, <br />w <br />W <br />Z <br />m <br />N <br />w <br />N <br />V <br />Lu <br />0 <br />0 <br />U <br />Al 00 <br />