Laserfiche WebLink
cj <br />w <br />c� <br />w <br />48" y <br />AFF <br />GFI <br />4 <br />4 <br />q <br />CO <br />LU <br />w <br />w <br />w <br />w <br />TT13 <br />1 Electrical Power Plan <br />Scale 1/8'=1'4" <br />Power Plan Key Notes: <br />1O EXISTING J-BOX AND EMPTY 3/4' CONDUIT. EXTEND <br />CONDUIT AS NEEDED AND RUN NEW WIRES TO NEW <br />TENANT PANEL VIA TIME CLOCK <br />O2 EXISTING RTU TO BE WIRED BACK TO NEW TENANT PANEL. <br />CONTRACTOR SHALL VERIFY THAT THERE IS AN EXISTING <br />SMOKE DUCT DETECTOR IN THE SUPPLY DUCT. IF THERE <br />ISN?, REFER TO MECHANICAL GENERAL NOTE # 7 ON <br />SHEET M101. THE GC SHALL BE RESPONSIBLE FOR <br />COORDINATING THE EXACT SCOPE OF WORK REQUIRED <br />BETWEEN THE MECHANICAL SUB AND THE ELECTRICAL <br />SUB PRIOR TO BIDDING. NO CHANGE ORDERS WILL BE <br />APPROVED FOR FAILURE TO VERIFY EXISTING <br />CONDITIONS OR COORDINATE BETWEEN SUBS. <br />O EXISTING FACTORY INSTALLED DISCONNECTS. FOR <br />POWER REQUIREMENTS TO RTU'S, RE: M101 AND <br />ELECTRICAL PANEL SCHEDULE ON THIS SHEET. <br />O4 EXISTING FACTORY INSTALLED POWERED CONVENIENCE <br />OUTLET. INSTALLATION SHALL BE PER SECTION 210.63 OF <br />THE NEC. COORDINATE WITH MECHANICAL. <br />48"AFF GFI <br />4 <br />Cn <br />GFI OUTLET <br />FOR FUTURE <br />REFRIGERATOR <br />BY TENANT <br />4 <br />O LOCATE NEW 200 AMP TENANT ELECTRICAL <br />PANEL AS CLOSE AS POSSIBLE TO EXISTING <br />CONDUIT STUB OUT. EXACT LOCATION SHALL <br />BE COORDINATED TO MAINTAIN REQUIRED <br />CLEARANCE AROUND REAR DOOR. REFER TO <br />RISER DIAGRAM ON THIS SHEET <br />O6 EXISTING 1' TELEPHONE CONDUIT STUBBED <br />INTO REAR OF TENANT SPACE FROM THE <br />EXISTING TELEPHONE TERMINAL CABINET ON <br />THE BACK OF THE BUILDING. <br />O7 RE-ROUTE EXISTING TELEPHONE CONDUIT TO <br />THIS LOCATION UNDERGROUND AND PROVIDE <br />TELEPHONE TERMINAL BOARD. PROVIDE <br />TELEPHONE CABLE FROM TELEPHONE <br />TERMINAL BOARD TO COMMUNICATION <br />OUTLET LOCATIONS SHOWN. <br />RISER KEY NOTES: <br />1. (1) SET OF EXISTING (4) # 310 & (1) # 310 G, IN EXISTING 2' CONDUIT <br />2. (1) SET OF NEW (4) # 310 & (1) # 6 G, IN EXISTING 2' CONDUIT <br />3. (1) EXISTING 4" TO 2" REDUCER <br />4. (1) SET OF NEW (4) # 310 & (1) # 6 G, IN EXISTING 4" CONDUIT <br />5. (1) NEW 4' TO 2' REDUCER AT TOP OF EXISTING STUB IN <br />Fire Alarm Plan Key Notes: <br />11 ALL FIRE ALARM EQUIPMENT IS SHOWN FOR <br />REFERENCE PURPOSES ONLY. FIRE ALARM <br />DESIGN DRAWINGS SHALL BE SUBMITTED <br />BY TENANT BUILD -OUT CONTRACTOR, <br />SIGNED AND SEALED BY STATE OF FLORIDA <br />LICENSED AND REGISTERED ENGINEER. <br />Lighting Plan Key Notes: <br />21 EXISTING DECORATIVE SCONCE FIXTURES <br />SHALL REMAIN WIRED AS IS TO THE <br />EXISTING HOUSE PANEL. <br />22 EXISTING REAR WALL MOUNTED LIGHT <br />SHALL BE WIRED TO THE NEW TENANT <br />PANEL VIA A NEW LIGHT SWITCH. <br />2 Fire Alarm Plan <br />Scale 1/8"=1'4" <br />Light General Notes <br />1. VENDOR SHALL VERIFY ALL FIXTURE QUANTITIES. <br />2. VERIFY FIXTURE LOCATION, SEE REFLECTED CEILING PLAN. <br />3. MOUNTING HEIGHTS INDICATED ARE TO THE CENTER LINE OF <br />DEVICE OR FIXTURE UNLESS OTHERWISE NOTED. <br />4. ALL FIXTURES TO BE CENTERED ON 2X4 CEILING GRID U.O.N. <br />5. ALL FIXTURES TO BE PROVIDED BY, RECEIVED, STORED & <br />INSTALLED BY ELECTRICAL CONTRACTOR. <br />6. ELECTRICAL CONTRACTOR SHALL SUPPLY 10% ADDITIONAL <br />SPARE OF ALL LAMP TYPES TO BE LEFT AT JOB SITE AT END <br />OF JOB. <br />7. CIRCUIT BREAKERS USED AS SWITCHES IN 120V AND 277V <br />FLUORESCENT LIGHTING CIRCUITS SHALL BE LISTED AND <br />SHALL BE MARKED SWD OR HID. <br />6. (1) SET OF NEW (4) # 310 & (1) # 6 GROUND IN NEW 2' CONDUIT. <br />7. (1) NEW 7-DAY, 4 CIRCUIT PROGRAMMABLE TIME CLOCK <br />ALL WIRING SHALL BE COPPER ONLY. <br />CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR <br />TO SUBMITTING BIDS. IF EXISTING CONDITIONS ARE NOT AS <br />SPECIFIED, CONTRACTOR SHALL NOTIFY THE ARCHITECT I <br />ENGINEER IMMEDIATELY. <br />EXISTING 12" X 12" WP WIREWAY WITH KEY TAPS <br />EXISTING <br />1200 AMP O 10DISCONNECT ��...�i" <br />3P / 4W <br />120 / 208 V <br />NEMA 3R <br />EXISTING <br />DIS- <br />CONNECT <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />200 AMP <br />200 AMP <br />200 AMP <br />UTILITY COMPANY <br />DIS- <br />TRANSFORMER <br />I <br />CONNECT <br />CONNECT <br />CONNECT <br />I <br />.3. <br />2� <br />LJL' <br />I <br />i <br />G <br />is <br />G1 <br />1 <br />I 3 <br />n <br />EXISTING SECONDARY CONDUIT TO CONDUIT TO EXISTING <br />SPACE D2 SPACE D3-D4 CONDUIT NO <br />EXISTING GROUND _ ' FOR FUTURE FOR EXISTING LONGER USED <br />TENANT TENANT <br />3 Building Power Riser Diagram <br />SCALE: NTS <br />EXISTING <br />400 AMP <br />DISCONNECT <br />EXISTING <br />HOUSE <br />PANEL <br />HPD1 <br />120 / 208 <br />(7 C <br />3 Electrical Lighting Plan <br />Scale 1/8 4-0" <br />Light Fixture Schedule <br />TYPE <br />MANUFACTURER <br />CATALOG NO. <br />VOLT <br />LAMPS <br />MOUNTING & OPTION <br />NOTE <br />A <br />DAYBRITE <br />2TG8-3-32-01-UNV-1/3-EB <br />120 <br />(3) 32W TS <br />GRID MOUNTED <br />1-3,5-6 <br />C <br />NITE BRITES <br />WCR-050-M-MT <br />120 <br />- <br />EXISTING TO REMAIN <br />EM <br />BEGHELLI <br />XLP-S1 <br />120 <br />- <br />WALL MTD AT 9'-0"AFF <br />2 & 4 <br />X <br />BEGHELLI <br />VA4-R-SA <br />120 <br />1 LED (INCLUDED) <br />UNIVERSAL <br />2 & 4 <br />ALTERNATE FIXTURES MAY BE COOPER, LITHONIA, GENLYTE, HUBBELL, OR THOMAS. FIXTURE <br />SUBSTITUTIONS MUST BE APPROVED BY OWNER BEFORE THEY ARE SUBMITTED TO THE ENGINEER. <br />1. ALL FLUORESCENT LIGHTING FIXTURES SHALL 4. <br />ALL EMERGENCY, EXIT AND NIGHT LIGHT FIXTURES <br />HAVE ENERGY SAVING LAMPS AND ELECTRONIC <br />SHALL BE CONNECTED AHEAD OF LOCAL SWITCHES. <br />BALLASTS. <br />UNLESS OTHERWISE NOTED. <br />2. PROVIDE NECESSARY MOUNTING HARDWARE 5. <br />ALL ALTERNATE FIXTURES SHALL BE SUBMITTED <br />AND ACCESSORIES FOR ALL FIXTURES. <br />FOR PRIOR APPROVAL, SEE SPECIFICATIONS. <br />3. PROVIDE .125 MIN. THICK LENSES FOR 6. <br />CONTACT SESCO LIGHTING (407) 629-6100 DAN <br />FLUORESCENT FIXTURES. <br />SCHULMAN <br />EXISTING <br />75 KIA STEP UP <br />TRANSFORMER <br />EXISTING <br />HOUSE <br />PANEL <br />HPD2 <br />2771480 <br />EXISTING <br />400 AMP <br />DISCONNECT <br />TO REMAIN <br />UNUSED <br />CONDUIT TO <br />SPACE 65-D6 <br />FOR EXISTING <br />TENANT <br />Electrical Legend <br />NOTES: 1. MOUNTING HEIGHTS SHOWN ARE MAX. / MIN. HANDICAP ACCESSIBILITY 2. NOT ALL DEVICES SHOWN IN LEGEND ARE REQUIRED. RE: PLANS <br />STANDARDS - THEY SHALL NOT BE ALTERED W / 0 WRITTEN AUTHORIZATION. & DETAILS FOR ITEMS WHICH APPLY TO THIS PROJECT. <br />A®a A®a <br />FLUORESCENT LIGHT FIXTURE, LETTER INDICATES TYPE. SEE FIXTURE <br />LOWER CASE SWITCH <br />- <br />SCHEDULE. LETTER INDICATES (IF USED) <br />A*--8­48 <br />FLUORESCENT STRIP LIGHT, LETTER INDICATES TYPE. SEE FIXTURE <br />SCHEDULE. LOWER CASE LETTER INDICATES SWITCH (IF USED) <br />p o, p <br />SURFACE MOUNTED LIGHT, LETTER INDICATES TYPE. SEE FIXTURE <br />SCHEDULE. LOWER CASE LETTER INDICATES SWITCH (IF USED) <br />O B -0- B <br />INCANDESCENT OR HID LIGHT FIXTURE, LETTER INDICATES TYPE <br />SEE LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />(� C Q C <br />WALL BRACKET LIGHT FIXTURE, LETTER INDICATES TYPE SEE <br />LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />NL <br />NIGHT LIGHT FIXTURE (NL) <br />® X <br />EXIT LIGHT (SHADE AREA INDICATES DIRECTION) LETTER INDICATES TYPE <br />SEE LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />BATTERY POWERED EMERGENCY LIGHT <br />TRACK LIGHTING AND TRACK. FOR INFORMATION ON TRACK SEE <br />LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />WALL WASHER FIXTURE. (SHADE AREA INDICATES DIRECTION) SEE <br />LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />SINGLE POLE SWITCH, LOWER CASE LETTER INDICATES LIGHTS <br />CONTROLLED. LETTER NOT SHOWN IF SELF EVIDENT. MOUNT <br />a <br />48" A.F.F. U.O.N. <br />F <br />SINGLE POLE SWITCH. FAN CONTROLLER, MOUNT 48" A.F.F. U.O.N. <br />3 <br />3-WAY SWITCH, FOR CONTROLLING LIGHTS FROM TWO DIFFERENT POINTS. <br />® <br />TWO GANG FLOOR OUTLET BOX. ONE QUADPLEX ISOLATED GROUND <br />RECEPTACLE AND ONE COMPUTER OUTLET. <br />�. 01 <br />WIREMOLD-WALKER INFLOOR SYSTEMS. RC4 FLUSH QUAD POKE <br />THRU SERIES WITH FOUR MULTIMEDIA COMMUNICATION LOCATIONS <br />WIREMOLD WALLSOURCE MULTIPLE SERVICE BOX. <br />QUADPLEX FLOOR RECEPTACLE OUTLET. <br />QUADPLEX RECEPTACLE OUTLET. <br />QUADPLEX RECEPTACLE OUTLET MOUNTED ABOVE COUNTER TOP U.O.N. <br />O <br />DUPLEX FLOOR RECEPTACLE OUTLET. <br />1�: <br />DUPLEX RECEPTACLE, MOUNT 18' AFF UON <br />0. <br />DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER HEIGHT U.O.N. <br />GFI <br />GROUND FAULT INTERRUPTER RECEPTACLE, LEVITON #6898-I, MOUNT <br />ABOVE COUNTER HEIGHT U.O.N. <br />I.G. <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362-IGI <br />MOUNTED ABOVE COUNTER HEIGHT. U.O.N. <br />I.G. <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362-IGI <br />MOUNT AT 18" AFF UON <br />$ <br />DUPLEX RECEPTACLE, MOUNTED ABOVE STOREFRONT WINDOWS <br />SINGLE RECEPTACLE, MOUNTED AT HEIGHT NOTED ON PLANS <br />® <br />SPECIAL PURPOSE RECEPTACLE OUTLET <br />O <br />JUNCTION BOX (FLUSH MOUNT IN FINISHED AREAS U.O.N.) <br />LIGHTING, POWER, FACP PANELBOARD OR TELE. TERM. CABINET. <br />MSBANDP <br />MAIN SWITCHBOARD OR MAIN DISTRIBUTION PANEL <br />CONDUIT CONCEALED IN WALL, BELOW SLAB, OR ABOVE CEILING. <br />CONDUIT EXPOSED ON WALL OR CEILING. <br />FLEXIBLE CONDUIT NOT TO EXCEED 6 FEET IN LENGTH <br />A-1 ,3 <br />CONDUIT RUN CONCEALED IN WALLS BELOW SLAB, OR CEILING SPACES. <br />ARROWS INDICATE HOMERUN. SMALL HASHMARKS INDICATE NUMBER OF <br />HOT CONDUCTORS, AND LARGE HASHMARK INDICATES NEUTRAL. <br />SUBSCRIPT INDICATES PANEL AND CIRCUIT NUMBERS. GROUND <br />CONDUCTOR REQUIRED IN ALL CONDUITS BUT NOT INDICATED. <br />A-37:39:41 <br />SUBSCRIPT INDICATES PANEL -AND NUMBERS WITH COLONS <br />INDICATE 2 OR 3 POLE CIRCUITS. <br />`O <br />DISCONNECT SWITCH <br />100/3I60 <br />DISCONNECT DESIGNATION (SIZE/POLES/FUSE) "NF" INDICATES <br />NON -FUSED; "DE" INDICATES DUAL ELEMENT FUSES. <br />EF <br />MOTOR PERMANENTLY CONNECTED WITH FLEXIBLE CONDUIT <br />(HORSEPOWER OR EQUIPMENT INDICATED) <br />THERMOSTAT. PROVIDE SINGLE GANG BOX WITH 1/2' C. STUBBED <br />OT <br />INTO CEILING SPACE, MOUNT 60" A.F.F. U.O.N. (COORDINATE WITH <br />MECHANICAL DRAWINGS PRIOR TO ROUGH -IN) <br />TELEPHONE WALL OUTLET, PROVIDE SINGLE GANG BOX WITH 3/4' <br />CONDUIT WITH PULL WIRE AND INSULATING BUSHING STUBBED INTO <br />CEILING SPACE. MOUNT BOX 18" A.F.F. U.O.N. <br />0 <br />COMPUTER OUTLET. MOUNT BOX @ 18' A.F.F. U.O.N. <br />(D <br />CEILING MOUNTED AUDIO SPEAKERS <br />OD <br />CEILING MTD. SENSOR DEVICE <br />FIRE ALARM PULL STATION <br />MF <br />HORN/STROBE <br />G)SMOKE <br />DETECTOR <br />U)HEAT <br />DETECTOR <br />FACP <br />FIRE ALARM CONTROL PANEL <br />EF <br />BATH ROOM FAN LIGHT <br />—Q\ <br />I <br />FIRE ALARM VISUAL ANNUNCIATOR <br />ABBREVIATIONS <br />ACC-CU <br />CONDENSING UNIT <br />LB <br />LOCK BREAKER <br />AFF <br />ABOVE FINISH FLOOR <br />NF <br />NON -FUSED <br />AFG <br />ABOVE FINISH GRADE <br />NIC <br />NOT IN CONTRACT <br />A/H-AHU <br />AIR HANDLING UNIT <br />NL <br />NIGHT LIGHT <br />C/T <br />CURRENT TRANSFORMER <br />NTS <br />NOT TO SCALE <br />DE <br />DUAL ELEMENT FUSE <br />OS <br />OCCUPANCY SENSORS <br />EC <br />EMPTY CONDUIT <br />PC <br />PULL CHAIN <br />E/F-EF <br />EXHAUST FAN <br />RTU <br />ROOF TOP UNIT <br />EG <br />EQUIPMENT GROUND <br />TTB <br />TELEPHONE TERMINAL BOARD <br />EM <br />EMERGENCY LIGHT <br />TTC <br />TELEPHONE TERMINAL CABINET <br />EWC <br />ELECTRIC WATER COOLER <br />TYP <br />TYPICAL <br />EWH <br />ELECTRIC WATER HEATER <br />LION <br />UNLESS OTHERWISE NOTED <br />EX <br />EXISTING DEVICE TO REMAIN <br />VTC <br />VIA TIME CLOCK <br />FACP <br />FIRE ALARM CONTROL PANEL <br />WP <br />WEATHERPROOF <br />GFI <br />GROUND FAULT INTERRUPTER <br />X <br />EXIT LIGHT <br />IG <br />ISOLATED GROUND <br />NOTE: MOUNTING HEIGHTS NOTED ARE TO BOTTOM OF DEVICE SHOWN UON <br />U <br />S2 <br />8 <br />CU <br />C <br />O <br />Q <br />0 <br />�•/ W <br />CU 15 <br />0 cr) <br />.� ch <br />(DaU--j <br />w <br />Q <br />Iw <br />.��IL <br />M oQ <br />J <br />�U <br />O <br />E <br />E <br />0 <br />U <br />L <br />i <br />W <br />No <br />CU 0 <br />J <br />Q m <br />Q <br />W <br />CU It <br />Qp <br />> <br />♦♦^^ <br />y,mJ <br />LU <br />= JUj <br />U <br />0 <br />�COa <br />'"� N <br />a <br />v <br />0o <br />N <br />en O <br />b.0 <br />�w <br />Qo <br />i <br />C" <br />J <br />0 <br />C <br />CO <br />L <br />Q" <br />ve <br />_W <br />i <br />U) <br />J <br />CU <br />w V.J <br />H <br />w <br />w Uj <br />s <br />co <br />w <br />Cn <br />w <br />IL <br />N <br />LO <br />O <br />w <br />O <br />R <br />w <br />r� <br />Z� <br />o <br />0 <br />WY0 <br />LU <br />N <br />w <br />N <br />Q <br />L) <br />LU <br />a <br />o <br />o <br />U <br />E101 <br />