Laserfiche WebLink
ARCHTECT <br />DesignTech <br />International <br />Architecture Planning 9 Inferior Design <br />14125 NW 80th AVENUE , SUITE # 303 , MIAMI LAKES, FLORIDA 33016 <br />TELEPHONE: (786) 235-9097 FAX: (305) 821-5911 <br />www.dtlarchitect.com <br />AA 26001933 <br />GENERAL NOTES <br />1. QU,4LIT`r 456URANCE; <br />A) USE ADEQUATE NUMBERS OF SKILLED WORKER-5 WHO ARE THOROUGHLY TRAINED AND <br />EXPERIENCED IN THE NECESSARY GRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE <br />SPECIFIED REQUIREMENTS AND THE METH005 NEEDED FOR THE PROPER PERFORMANCE OF THE <br />WORK OF SPECIFIED HEREIN. <br />B) ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE FLORIDA BLDG. CODE <br />2010 EDIT. <br />C) COORDINATE DIMEN5ION5 OF ALL D150IPLINE5 WITH ARCHITECTURAL DRAWIN65. DO NOT SCALE <br />DRAWING5 <br />2. 5U51" IITTAL5- <br />A) PRODUCT DATA: WHERE PRODUCT DATA 15 GALLED FOR, PROVIDE THE FOLLOWING AS A MINIMUM: <br />1) MATERIALS LI5T OF ITEMS PROP05ED TO BE PROVIDED UNDER SPECIFIC DIV15ION OF WORK. <br />2) MANUFACTURER5 SPECIFICATIONS AND OTHER DATA NEED TO PROVE COMPLIANCE WITH THE <br />SPECIFIED REQUIREMENTS. <br />5) COLOR AND PATTERN CHARTS 5HOWIN(v COLORS AND PATTERNS AVAILABLE IN THE SPECIFIED <br />PRODUCTS FROM THE PROPOSED MANUF. <br />4) MANUFACTURERS RECOMMENDED INSTALLATION PROCEDURES WHICH, WHEN APPROVED BY THE <br />ARCHITECT, WILL BECOME THE BA515 FOR ACCEPTING OR REJECTING ACTUAL INSTALLATION <br />PROCEDURES USED ON THE WORK. <br />3. SITE CONDITIONS: <br />A) MEASUREMENTS: VERIFY ALL DIMENSIONS ON DRAWINGS BY TAKING FIELD MEASUREMENTS; PROPER <br />FIT AND ATTACHMENT OF ALL PARTS 15 REQUIRED. <br />B) SURFACE CONDITIONS: EXAMINE THE AREAS AND CONDITIONS UNDER WHIGH WORK SPECIFIED WILL BE <br />PERFORMED. CORRECT CONDITION5 DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF THE WORK. <br />DO NOT PROCEED UNTIL UN5AT15FACTORY CONDITIONS ARE CORRECTED. <br />C) COORDINATION: COORDINATE AS REQUIRED WITH OTHER TRADES TO A55URE PROPER AND ADEQUATE <br />PROV15ION IN THE WORK OF TH05E TRADES FOR INTERFACE WITH THE WORK SPECIFIED. <br />4. ACCEPTABLE 1" IANUFACTURER5: <br />A) THE SPECIFIED MANJFACTURERS/PRODUCTS/5Y5TEM5 HAVE BEEN ESTABLISHED AS 5TANDARD5 OF <br />QUALITY, FUNCTION AND DE516N. ALTERNATE MANUFACTURERS WHICH CAN DUPLICATE THE ITEMS <br />DETAILED MAY SUBMIT SHOP DRAWINGS, EN&INEERIN6/PRODUGT DATA AND 5AMPLE5 FOR <br />CONSIDERATION. <br />5. INSTALLATION/APPL ICATION- <br />A) INSTALL THE WORK SPECIFIED HEREIN IN STRICT ACCORDANCE WITH THE ORIGINAL DESIGN, THE <br />APPROVED SHOP DRAWINGS, PERTINENT REQUIREMENTS OF GOVERNMENTAL AGENCIE5 HAVING <br />JURISDICTION, AND THE MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES AS APPROVED BY <br />THE ARCHITECT, ANCHORING ALL COMPONENTS FIRMLY INTO POSITION FOR LON6 LIFE UNDER HARD USE. <br />1) ALL DETAILS AND SECTIONS SHOWN IN THE CONSTRUCTION DOCUMENTS ARE INTENDED TO BE TYPICAL <br />AND TO APPLY TO ANY SIMILAR 51TUATION E1-5EHHERE IN THE PROJECT, EXCEPT OTHERWISE INDICATED. <br />2) ALL CONTRACTORS ARE TO FAMILIARIZE THEMSELVES WITH EXI5TIN6 CONDITIONS, MATERIALS AND <br />QUANTITIES PRIOR TO SUBMITTIN6 BID. IF DISCREPANCIES ARE FOUND NOTIFY ARCHITECT IMMEDIATELY. <br />5) GENERAL CONTRACTOR SHALL CHECK ARCHITECTURAL DRAAIN65 FOR WALL MOUNTED AND CEILING <br />MOUNTED DEVICES PRIOR TO INSTALLATION OF GEILIN6, AND SHALL ASSUME FULL RESPONSIBILITY FOR <br />THEIR PROPER LOCATIONS. <br />4) IF CONTRACTOR/51,15GONTRACTOR FIND IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED <br />PLANS, THEN IT 15 THE CONTRACTOR/SUBGONTRACTOR RESPONSIBILITY TO PROVIDE THE ARCHITECT <br />WITH FOUR COPIES OF THE PROP05ED CHANGES FOR APPROVAL BEFORE PROCEEDING WITH THE WORK. <br />5) IN ADDITION THE CONTRACTOR/SUBCONTRACTOR 15 RESPONSIBLE FOR PROCURING ALL NECESSARY <br />APPROVAL5 FROM BUILDING AUTHORITIE5 FOR THE PROPOSED CHANGES, BEFORE PROCEEDING WITH <br />THE WORK. THE CONTRACTOR/5UBCONTRACTOR ARE AL50 RESPONSIBLE FOR PROCURIN6 ALL <br />NECESSARY INSPECTIONS AND APPROVAL FROM BUILDING AUTHORITIES DURING THE EXECUTION OF THE <br />WORK. <br />6) CONTRACTOR SHALL PROVIDE AND INSTALL THE GREATEST QUANTITY AND/OR BEST QUALITY OF <br />WORK A5 SHOWN IN, GALLED FOR IN, OR REASONABLY INFERABLE FROM THE BID DOCUMENTS A5 <br />REQUIRED TO OBTAIN THE FINAL RESULT AND CONFI6URATION GALLED FOR OR 5HOAN IN THE BID <br />DOCUMENTS. <br />(oCONSTRUCTION D0CUMENT6 INTENT: <br />A) THE INTENT OF THE CONTRACT DOCUMENTS 15 TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER <br />EXECUTION AND COMPLETION OF THE WORK BY THE CONTRACTOR. THE CONTRACT DOCUMENTS ARE <br />COMPLEMENTARY, AND WHAT 15 REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL: <br />PERFORMANCE BY THE CONTRACTOR SHALL BE REQUIRED ONLY TO THE EXTENT CONSISTENT WITH THE <br />CONTRACT DOCI%ENT5 AND REASONABLY INFERABLE FROM THEM A5 BEIN6 NECESSARY TO PRODUCE THE <br />INDICATED REE-A—T5. <br />PROPOSED VACANT BUILDOUT <br />AT ZEPHYR COMMONS SHOPPING CENTER <br />SYMBOLOGY / LEGEND <br />ELEVATION NUMBER <br />DETAIL, SECTION OR <br />OR PLAN NUMBER <br />WALL SECTION NUMBER, <br />BUILDING SECTION LETTER <br />SHEET NUMBER <br />DETAIL NUMBER <br />SHEET NUMBER <br />a NOTE NUMBER <br />0- UJINDOUJ NUMBER <br />0__ <br />DOOR NUMBER <br />A-REVISION NUMBER <br />ROOM----RROOM NAME <br />XXX ROOM NUMBER <br />116'-0" ELEV. DATUM POINT <br />TRUSS BRG. <br />COLUMN GRID <br />D__NIJME3EfR OR <br />LETTER <br />NORTH ARROW <br />;6 <br />U.S. HIGHWAY 301 & PRETTY POND ROAD <br />ZEPHYRHILLS, FL 33541 <br />PROJECT # 14025.01 <br />I SCOPE OF WORK I <br />THE SCOPE OF WORK UNDER TH15 PERMIT SHALL CONSIST OF PROVIDING A 5ET <br />OF CONSTRUCTION DOCUMENT5 FOR A GRAY SHELL A5 DEFINED BY THESE <br />DOCUMENTS. <br />THE PROJECT CON51515 OF PUTTING UP A DEMISING WALL AND EMERGENCY <br />LIGHTING SO THAT THE TENANT COULD PUT UP THEIR OWN SPACE. <br />LEGAL DESCRIPTION <br />LOT 3 AND THE SOUTH 29.12 FEET OF LOT 2, ZEPHYR COMMONS PHASE 1, <br />ACCORDING TO THE MAP OR PLAT THEREOF A5 RECORDED IN PLAT BOOK, 62, <br />PAGES 132 THROU-H 142, OF THE PUBLIC RECORDS OF PA5CO COUNTY, FLORIDA. <br />PROJECT DIRECTORY <br />OWNER: <br />NORTH AMERICAN <br />DEVELOPMENT GROUP <br />400 CLEMATIS STREET, SUITE 201 <br />WEST PALM BEACH, FLORIDA, 33401 <br />STRUCTURAL: <br />J.A. MESSULAN <br />5121 ORDUNA DR <br />CORAL GABLE5, FL <br />PHONE: 305-665-5032 <br />CONTACT: CARLOS CARD050 <br />MEP <br />COLWILL ENGINEERING <br />CONSULTING ENGINEERS, INC. <br />4150 EAST ADAMO DRIVE <br />TAMPA, FLORIDA, 33605 <br />ARCHITECT: <br />DESIGN TECH INTERNATIONAL ASSOC., INC. <br />14125 NW SOth AVENUE, SUITE 0303 <br />MIAMI LAKES, FLORIDA, 3301fo <br />PHONE: (186) 235-9091 <br />CONTACT: William Romberg <br />Cl VIL: <br />AVID GROUP <br />2300 CURLEW ROAD 6UITE 201 <br />PALM HARBOR, FLORIDA, 34683 <br />PHONE: (121)185-9500 <br />AIL WORK SHALL COMPLY WITH ALL <br />G <br />PUVXMG CODES, FLORIDA CODE AI�D <br />CO <br />D,NATIONALELT SORDINANCES <br />CITY Oy i <br />EpUZ'RHIL= <br />6,4f(AVJ <br />le <br />REvIEw Y <br />CIS OF Z DINER <br />Po NS EXP <br />DEVELOPER: <br />PROJECT SUMMARY <br />1. APPLICABLE CODES <br />THE FOLLOWING BUILDING CODES, CURRENT EDITIONS UNLESS OTHERWISE <br />SPECIFIED, WILL BE ADHERED TO: <br />SCOPE <br />YEAR / CODE <br />BUILDING <br />2010 FLORIDA BUILDING CODE WITH 2O0q SUF'PLEMENT <br />BUILDING <br />2010 FLORIDA EXISTING BUILDING CODE <br />ACCESSIBILITY <br />2010 FLORIDA BUILDING CODE, CHAPTER II <br />ACCESSIBILITY <br />2010 DEPARTMENT OF JU5TICE (ADA) <br />LIFE SAFETY <br />2012 NFPA LIFE 5AFE7Y CODE 101 AND NFPA I <br />FIRE PREVENTION <br />2010 FLORIDA FIRE PREVENTION CODE <br />ENERGY <br />FL EFFICIENCY CODE FOR BLDN6 CONSTRUCTION <br />ELECTRIC <br />2011 NATIONAL ELECTRIC CODE <br />PLUMBING <br />2010 FLORIDA BUILDING CODE, PLUMBING <br />MECHANICAL <br />2010 FLORIDA BUILDING CODE, MECHANICAL <br />GAS <br />2010 FLORIDA BUILDING CODE, FUEL GAS <br />11. ZONING DESCRIPTION: <br />SEE THIS SHEET FOR LEGAL DESCRIPTION <br />BUILDING DATA <br />I. OCCUPANCY CLASSIFICATION <br />2010 FBC <br />2012 NFPA <br />GROUP M, MERCANTILE <br />(CHAPTER 3 SECTION 30e) <br />MERCANTILE <br />(CHAPTER 36) <br />II. TYPE OF CONSTRUCTION <br />CODE <br />2010 FBC <br />2012 NFPA <br />TYPE OF CONSTRUCTION <br />CsROUP M TYPE II-B <br />NOT SPRINKLERED <br />CHAPTER 6 <br />MERCANTILE <br />CHAPTER 36 <br />CONSTRUCTION COMPONENT <br />REQUIRED RATING <br />2010 FBC TYPE II-B <br />Table 601 <br />REQUIRED RATING <br />NFPA TYPE 1/ (000) <br />Table A.8.2.1.2 <br />STRUCTURAL FRAME <br />(0 hr.) <br />(0 hr) <br />EXTERIOR BEARING WALLS <br />(0 hr.) <br />(0 hr.) <br />INTERIOR BEARING WALLS <br />(0 hr.) <br />(0 hr) <br />EXT. NON -BEARING WALLS (20'<x<30') <br />(O hr) <br />(0 hr) <br />INT. NON -BEARING WALLS AND PARTITION <br />(O hrJ <br />(0 hr.) <br />FLOOR CONSTRUCTION <br />(0 hr.) <br />(0 hr.) <br />ROOF CONSTRUCTION <br />(0 hr.) <br />(0 hr.) <br />FIRE RESISTANCE RATINGS <br />AT FIRE WALLS, CHASES AND PARTITIONS <br />F.B.0 TABLE 302.3.2 <br />F.B.0 707, <br />*Minimum Fire Resistance <br />of Walls and Partitions <br />Shafts less than 4 stories <br />1 HR <br />cupancl <br />F1r�GSepaeok second floor <br />N/A <br />Fire Separation between Tenants <br />1 HR <br />Flre Wall Separation Between Bulldings <br />4 HR <br />III. ALLOWABLE HEIGHT <br />& BUILDING AREA <br />(CHAPTER 5, TABLE 503) <br />ALLOWABLE AREA <br />OCC GROUP/ CONST <br />TABLE <br />503 <br />AREA INCREASE <br />EQUATION 5-1, FBC 506.1 <br />PROPSED AREA <br />M OCCUPANCY <br />TYPE 115 <br />UNSPRINKLERED <br />12,500 SF <br />N/R <br />1,500 SQ. FT. <br />ALLOWABLE HEIGHT & STORY'S <br />OCC GROUP/ CONST <br />HEIGHT <br />STORY'S <br />TABLE 503 <br />PROPOSED <br />TABLE 503 <br />PROPOSED <br />GROUP M, <br />TYPE 115 <br />UNSPRINKLERED <br />55'-0" <br />24'-0" <br />4 <br />I <br />SHEET INDEX <br />ISHT. NO.1 DESCRIPTION <br />A-O I COVER PAGE <br />ARCHITECTURAL DRAWINGS <br />A-1.0 1 LIFE 5AFE7Y PLAN <br />A-2.0 I PROP05ED FLOOR PLAN <br />A-5.0 I REFLECTED CEILING PLAN I <br />A-4.0 I WALL TYPES I <br />PERMIT SET <br />