ARCHTECT
<br />DesignTech
<br />International
<br />Architecture Planning 9 Inferior Design
<br />14125 NW 80th AVENUE , SUITE # 303 , MIAMI LAKES, FLORIDA 33016
<br />TELEPHONE: (786) 235-9097 FAX: (305) 821-5911
<br />www.dtlarchitect.com
<br />AA 26001933
<br />GENERAL NOTES
<br />1. QU,4LIT`r 456URANCE;
<br />A) USE ADEQUATE NUMBERS OF SKILLED WORKER-5 WHO ARE THOROUGHLY TRAINED AND
<br />EXPERIENCED IN THE NECESSARY GRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE
<br />SPECIFIED REQUIREMENTS AND THE METH005 NEEDED FOR THE PROPER PERFORMANCE OF THE
<br />WORK OF SPECIFIED HEREIN.
<br />B) ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE FLORIDA BLDG. CODE
<br />2010 EDIT.
<br />C) COORDINATE DIMEN5ION5 OF ALL D150IPLINE5 WITH ARCHITECTURAL DRAWIN65. DO NOT SCALE
<br />DRAWING5
<br />2. 5U51" IITTAL5-
<br />A) PRODUCT DATA: WHERE PRODUCT DATA 15 GALLED FOR, PROVIDE THE FOLLOWING AS A MINIMUM:
<br />1) MATERIALS LI5T OF ITEMS PROP05ED TO BE PROVIDED UNDER SPECIFIC DIV15ION OF WORK.
<br />2) MANUFACTURER5 SPECIFICATIONS AND OTHER DATA NEED TO PROVE COMPLIANCE WITH THE
<br />SPECIFIED REQUIREMENTS.
<br />5) COLOR AND PATTERN CHARTS 5HOWIN(v COLORS AND PATTERNS AVAILABLE IN THE SPECIFIED
<br />PRODUCTS FROM THE PROPOSED MANUF.
<br />4) MANUFACTURERS RECOMMENDED INSTALLATION PROCEDURES WHICH, WHEN APPROVED BY THE
<br />ARCHITECT, WILL BECOME THE BA515 FOR ACCEPTING OR REJECTING ACTUAL INSTALLATION
<br />PROCEDURES USED ON THE WORK.
<br />3. SITE CONDITIONS:
<br />A) MEASUREMENTS: VERIFY ALL DIMENSIONS ON DRAWINGS BY TAKING FIELD MEASUREMENTS; PROPER
<br />FIT AND ATTACHMENT OF ALL PARTS 15 REQUIRED.
<br />B) SURFACE CONDITIONS: EXAMINE THE AREAS AND CONDITIONS UNDER WHIGH WORK SPECIFIED WILL BE
<br />PERFORMED. CORRECT CONDITION5 DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF THE WORK.
<br />DO NOT PROCEED UNTIL UN5AT15FACTORY CONDITIONS ARE CORRECTED.
<br />C) COORDINATION: COORDINATE AS REQUIRED WITH OTHER TRADES TO A55URE PROPER AND ADEQUATE
<br />PROV15ION IN THE WORK OF TH05E TRADES FOR INTERFACE WITH THE WORK SPECIFIED.
<br />4. ACCEPTABLE 1" IANUFACTURER5:
<br />A) THE SPECIFIED MANJFACTURERS/PRODUCTS/5Y5TEM5 HAVE BEEN ESTABLISHED AS 5TANDARD5 OF
<br />QUALITY, FUNCTION AND DE516N. ALTERNATE MANUFACTURERS WHICH CAN DUPLICATE THE ITEMS
<br />DETAILED MAY SUBMIT SHOP DRAWINGS, EN&INEERIN6/PRODUGT DATA AND 5AMPLE5 FOR
<br />CONSIDERATION.
<br />5. INSTALLATION/APPL ICATION-
<br />A) INSTALL THE WORK SPECIFIED HEREIN IN STRICT ACCORDANCE WITH THE ORIGINAL DESIGN, THE
<br />APPROVED SHOP DRAWINGS, PERTINENT REQUIREMENTS OF GOVERNMENTAL AGENCIE5 HAVING
<br />JURISDICTION, AND THE MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES AS APPROVED BY
<br />THE ARCHITECT, ANCHORING ALL COMPONENTS FIRMLY INTO POSITION FOR LON6 LIFE UNDER HARD USE.
<br />1) ALL DETAILS AND SECTIONS SHOWN IN THE CONSTRUCTION DOCUMENTS ARE INTENDED TO BE TYPICAL
<br />AND TO APPLY TO ANY SIMILAR 51TUATION E1-5EHHERE IN THE PROJECT, EXCEPT OTHERWISE INDICATED.
<br />2) ALL CONTRACTORS ARE TO FAMILIARIZE THEMSELVES WITH EXI5TIN6 CONDITIONS, MATERIALS AND
<br />QUANTITIES PRIOR TO SUBMITTIN6 BID. IF DISCREPANCIES ARE FOUND NOTIFY ARCHITECT IMMEDIATELY.
<br />5) GENERAL CONTRACTOR SHALL CHECK ARCHITECTURAL DRAAIN65 FOR WALL MOUNTED AND CEILING
<br />MOUNTED DEVICES PRIOR TO INSTALLATION OF GEILIN6, AND SHALL ASSUME FULL RESPONSIBILITY FOR
<br />THEIR PROPER LOCATIONS.
<br />4) IF CONTRACTOR/51,15GONTRACTOR FIND IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED
<br />PLANS, THEN IT 15 THE CONTRACTOR/SUBGONTRACTOR RESPONSIBILITY TO PROVIDE THE ARCHITECT
<br />WITH FOUR COPIES OF THE PROP05ED CHANGES FOR APPROVAL BEFORE PROCEEDING WITH THE WORK.
<br />5) IN ADDITION THE CONTRACTOR/SUBCONTRACTOR 15 RESPONSIBLE FOR PROCURING ALL NECESSARY
<br />APPROVAL5 FROM BUILDING AUTHORITIE5 FOR THE PROPOSED CHANGES, BEFORE PROCEEDING WITH
<br />THE WORK. THE CONTRACTOR/5UBCONTRACTOR ARE AL50 RESPONSIBLE FOR PROCURIN6 ALL
<br />NECESSARY INSPECTIONS AND APPROVAL FROM BUILDING AUTHORITIES DURING THE EXECUTION OF THE
<br />WORK.
<br />6) CONTRACTOR SHALL PROVIDE AND INSTALL THE GREATEST QUANTITY AND/OR BEST QUALITY OF
<br />WORK A5 SHOWN IN, GALLED FOR IN, OR REASONABLY INFERABLE FROM THE BID DOCUMENTS A5
<br />REQUIRED TO OBTAIN THE FINAL RESULT AND CONFI6URATION GALLED FOR OR 5HOAN IN THE BID
<br />DOCUMENTS.
<br />(oCONSTRUCTION D0CUMENT6 INTENT:
<br />A) THE INTENT OF THE CONTRACT DOCUMENTS 15 TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER
<br />EXECUTION AND COMPLETION OF THE WORK BY THE CONTRACTOR. THE CONTRACT DOCUMENTS ARE
<br />COMPLEMENTARY, AND WHAT 15 REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL:
<br />PERFORMANCE BY THE CONTRACTOR SHALL BE REQUIRED ONLY TO THE EXTENT CONSISTENT WITH THE
<br />CONTRACT DOCI%ENT5 AND REASONABLY INFERABLE FROM THEM A5 BEIN6 NECESSARY TO PRODUCE THE
<br />INDICATED REE-A—T5.
<br />PROPOSED VACANT BUILDOUT
<br />AT ZEPHYR COMMONS SHOPPING CENTER
<br />SYMBOLOGY / LEGEND
<br />ELEVATION NUMBER
<br />DETAIL, SECTION OR
<br />OR PLAN NUMBER
<br />WALL SECTION NUMBER,
<br />BUILDING SECTION LETTER
<br />SHEET NUMBER
<br />DETAIL NUMBER
<br />SHEET NUMBER
<br />a NOTE NUMBER
<br />0- UJINDOUJ NUMBER
<br />0__
<br />DOOR NUMBER
<br />A-REVISION NUMBER
<br />ROOM----RROOM NAME
<br />XXX ROOM NUMBER
<br />116'-0" ELEV. DATUM POINT
<br />TRUSS BRG.
<br />COLUMN GRID
<br />D__NIJME3EfR OR
<br />LETTER
<br />NORTH ARROW
<br />;6
<br />U.S. HIGHWAY 301 & PRETTY POND ROAD
<br />ZEPHYRHILLS, FL 33541
<br />PROJECT # 14025.01
<br />I SCOPE OF WORK I
<br />THE SCOPE OF WORK UNDER TH15 PERMIT SHALL CONSIST OF PROVIDING A 5ET
<br />OF CONSTRUCTION DOCUMENT5 FOR A GRAY SHELL A5 DEFINED BY THESE
<br />DOCUMENTS.
<br />THE PROJECT CON51515 OF PUTTING UP A DEMISING WALL AND EMERGENCY
<br />LIGHTING SO THAT THE TENANT COULD PUT UP THEIR OWN SPACE.
<br />LEGAL DESCRIPTION
<br />LOT 3 AND THE SOUTH 29.12 FEET OF LOT 2, ZEPHYR COMMONS PHASE 1,
<br />ACCORDING TO THE MAP OR PLAT THEREOF A5 RECORDED IN PLAT BOOK, 62,
<br />PAGES 132 THROU-H 142, OF THE PUBLIC RECORDS OF PA5CO COUNTY, FLORIDA.
<br />PROJECT DIRECTORY
<br />OWNER:
<br />NORTH AMERICAN
<br />DEVELOPMENT GROUP
<br />400 CLEMATIS STREET, SUITE 201
<br />WEST PALM BEACH, FLORIDA, 33401
<br />STRUCTURAL:
<br />J.A. MESSULAN
<br />5121 ORDUNA DR
<br />CORAL GABLE5, FL
<br />PHONE: 305-665-5032
<br />CONTACT: CARLOS CARD050
<br />MEP
<br />COLWILL ENGINEERING
<br />CONSULTING ENGINEERS, INC.
<br />4150 EAST ADAMO DRIVE
<br />TAMPA, FLORIDA, 33605
<br />ARCHITECT:
<br />DESIGN TECH INTERNATIONAL ASSOC., INC.
<br />14125 NW SOth AVENUE, SUITE 0303
<br />MIAMI LAKES, FLORIDA, 3301fo
<br />PHONE: (186) 235-9091
<br />CONTACT: William Romberg
<br />Cl VIL:
<br />AVID GROUP
<br />2300 CURLEW ROAD 6UITE 201
<br />PALM HARBOR, FLORIDA, 34683
<br />PHONE: (121)185-9500
<br />AIL WORK SHALL COMPLY WITH ALL
<br />G
<br />PUVXMG CODES, FLORIDA CODE AI�D
<br />CO
<br />D,NATIONALELT SORDINANCES
<br />CITY Oy i
<br />EpUZ'RHIL=
<br />6,4f(AVJ
<br />le
<br />REvIEw Y
<br />CIS OF Z DINER
<br />Po NS EXP
<br />DEVELOPER:
<br />PROJECT SUMMARY
<br />1. APPLICABLE CODES
<br />THE FOLLOWING BUILDING CODES, CURRENT EDITIONS UNLESS OTHERWISE
<br />SPECIFIED, WILL BE ADHERED TO:
<br />SCOPE
<br />YEAR / CODE
<br />BUILDING
<br />2010 FLORIDA BUILDING CODE WITH 2O0q SUF'PLEMENT
<br />BUILDING
<br />2010 FLORIDA EXISTING BUILDING CODE
<br />ACCESSIBILITY
<br />2010 FLORIDA BUILDING CODE, CHAPTER II
<br />ACCESSIBILITY
<br />2010 DEPARTMENT OF JU5TICE (ADA)
<br />LIFE SAFETY
<br />2012 NFPA LIFE 5AFE7Y CODE 101 AND NFPA I
<br />FIRE PREVENTION
<br />2010 FLORIDA FIRE PREVENTION CODE
<br />ENERGY
<br />FL EFFICIENCY CODE FOR BLDN6 CONSTRUCTION
<br />ELECTRIC
<br />2011 NATIONAL ELECTRIC CODE
<br />PLUMBING
<br />2010 FLORIDA BUILDING CODE, PLUMBING
<br />MECHANICAL
<br />2010 FLORIDA BUILDING CODE, MECHANICAL
<br />GAS
<br />2010 FLORIDA BUILDING CODE, FUEL GAS
<br />11. ZONING DESCRIPTION:
<br />SEE THIS SHEET FOR LEGAL DESCRIPTION
<br />BUILDING DATA
<br />I. OCCUPANCY CLASSIFICATION
<br />2010 FBC
<br />2012 NFPA
<br />GROUP M, MERCANTILE
<br />(CHAPTER 3 SECTION 30e)
<br />MERCANTILE
<br />(CHAPTER 36)
<br />II. TYPE OF CONSTRUCTION
<br />CODE
<br />2010 FBC
<br />2012 NFPA
<br />TYPE OF CONSTRUCTION
<br />CsROUP M TYPE II-B
<br />NOT SPRINKLERED
<br />CHAPTER 6
<br />MERCANTILE
<br />CHAPTER 36
<br />CONSTRUCTION COMPONENT
<br />REQUIRED RATING
<br />2010 FBC TYPE II-B
<br />Table 601
<br />REQUIRED RATING
<br />NFPA TYPE 1/ (000)
<br />Table A.8.2.1.2
<br />STRUCTURAL FRAME
<br />(0 hr.)
<br />(0 hr)
<br />EXTERIOR BEARING WALLS
<br />(0 hr.)
<br />(0 hr.)
<br />INTERIOR BEARING WALLS
<br />(0 hr.)
<br />(0 hr)
<br />EXT. NON -BEARING WALLS (20'<x<30')
<br />(O hr)
<br />(0 hr)
<br />INT. NON -BEARING WALLS AND PARTITION
<br />(O hrJ
<br />(0 hr.)
<br />FLOOR CONSTRUCTION
<br />(0 hr.)
<br />(0 hr.)
<br />ROOF CONSTRUCTION
<br />(0 hr.)
<br />(0 hr.)
<br />FIRE RESISTANCE RATINGS
<br />AT FIRE WALLS, CHASES AND PARTITIONS
<br />F.B.0 TABLE 302.3.2
<br />F.B.0 707,
<br />*Minimum Fire Resistance
<br />of Walls and Partitions
<br />Shafts less than 4 stories
<br />1 HR
<br />cupancl
<br />F1r�GSepaeok second floor
<br />N/A
<br />Fire Separation between Tenants
<br />1 HR
<br />Flre Wall Separation Between Bulldings
<br />4 HR
<br />III. ALLOWABLE HEIGHT
<br />& BUILDING AREA
<br />(CHAPTER 5, TABLE 503)
<br />ALLOWABLE AREA
<br />OCC GROUP/ CONST
<br />TABLE
<br />503
<br />AREA INCREASE
<br />EQUATION 5-1, FBC 506.1
<br />PROPSED AREA
<br />M OCCUPANCY
<br />TYPE 115
<br />UNSPRINKLERED
<br />12,500 SF
<br />N/R
<br />1,500 SQ. FT.
<br />ALLOWABLE HEIGHT & STORY'S
<br />OCC GROUP/ CONST
<br />HEIGHT
<br />STORY'S
<br />TABLE 503
<br />PROPOSED
<br />TABLE 503
<br />PROPOSED
<br />GROUP M,
<br />TYPE 115
<br />UNSPRINKLERED
<br />55'-0"
<br />24'-0"
<br />4
<br />I
<br />SHEET INDEX
<br />ISHT. NO.1 DESCRIPTION
<br />A-O I COVER PAGE
<br />ARCHITECTURAL DRAWINGS
<br />A-1.0 1 LIFE 5AFE7Y PLAN
<br />A-2.0 I PROP05ED FLOOR PLAN
<br />A-5.0 I REFLECTED CEILING PLAN I
<br />A-4.0 I WALL TYPES I
<br />PERMIT SET
<br />
|