Laserfiche WebLink
II�'111M'I II ' I <br />GENERAL <br />L <br />2. <br />3. <br />4. <br />FLOOR PLAN NOTES: <br />CHANGE OF ELEVATION AT ALL DOOR THRESHOLDS SHALL NOT EXCEED V2". <br />LEVEL AREAS REQUIRED CN BOTH SIDES OF DOORS AS PER 5-2.1 NFPA 101. <br />FIRE EXTING ISHERS SHALL BE LOCATED AS INDICATED IN FLOOR LIFE SAFETY PLAN. <br />CONTRACTOR TO VERIFY EXACT MILLWORK SIZE UATH MANUFACTURER TO FIT IN SPACES PRIOR TO <br />FABRICATION. SUBMIT SHOP DRAWINGS FOR REVIEW. <br />RODENT PROOFING NOTE: <br />G.G. SHALL PROVIDE RODENT -PROOFING AT SPACE TENANT IN ACCORDANCE WITH FLORIDA BUILDING CODE <br />SECTION 120U LATEST EDITION <br />TEWITE PROTECTION NOT <br />AREAS OF THE BUILDING WHERE CONCRETE SLAB IS REMMW SHALL RECEIVE A COMPLETE TREATMENT FOR <br />THE PREVENTION OF SUBTERRANEAN TERMITES PRIOR TO NEW CONCRETE BEING POUR TREATMENT IS N <br />ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE, CONSUMER <br />SERVICES AND THE 2010 FLORIDA BUILDING CODE SECTION 1816. <br />GENERAL SITE / FLOOR PLAN NOTES: <br />I. SEE CIVIL DRAWINGS FOR SITE PLAN. <br />2. G.C. SHALL COORDINATE ALL SITE WORK WITH CIVIL, PLUMBING, MECHANICAL, STRUCTURAL, ELECTRICAL AND <br />ARCHITECTURAL DRAWINGS. G.C. SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO COMMENCE WORK <br />3. G.C. SHALL COORDINATE WITH ALL UTILITY COMPANIES AS REQUIRED AND SHALL PROVIDE ALL REQUIRED UTILITY <br />WORK TO BE PERFORMED AS INDICATED BY CIVIL, PLUMBING, MECHANICAL, STRUCTURAL, ELECTRICAL AND <br />ARCHITECTURAL DRAWINGS AND/OR REQUIRED BY UTILITY COMPANIES. G.C. SHALL NOTIFY ARCHITECT OF ANY <br />DISCREPANCIES PRIOR TO COMMENCE WORK <br />4. G.C. SHALL COORDINATE WITH LOCAL POSTAL SERVICE PROVIDER FOR LOCATION, INSTALLATION AND PURCHASE OF <br />REQUIRED MAILBOXES. W. SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO COMMENCE WORK <br />S. W. SHALL PROVIDE "OUTDOOR PHONE BOX" AS REQUIRED BY UTILITY COMPANY. <br />PROPOSED FLOOR PLAN <br />SCALE: 1/6' = I'-0" <br />4 <br />GO WALK (rM) — - <br />- - - - -- - -- PN <br />II <br />005 , <br />PROPOSED <br />VAr..#ANTBUILDOUT <br />(AT&T) <br />I y 800 SF. <br />! i FOUNDATION _ FOUNDATION <br />AREA I <br />I PLANTING <br />DRAWING LEGEND <br />NEW CMU WALL WITH EXTERIOR STUCCO FINISH <br />G.C. TO PROVIDE 5/8, GWB. ON 3/4" RJRWNG <br />STRIPS IW R-5 INSULATION TO UNDERSIDE OF ROOF <br />DECK <br />i j f I NEW CM WALL WITH EXTERIOR STUCCO FINISH t <br />I EXPOSED ON THE INTERIOR <br />i NEW INTERIOR PARTITION: 35" (20 GA) MTL STUDS • <br />�`- Ib" O.C. W/I LAYER 5/8" GM. EACH SIDE TO <br />UNDERSIDE OF STRUCTURE UR-11 BATT INSULATION. <br />PROVIDE DUROCK MASONRY BOARD 0 WET AREAS. <br />FLOOR PLAN NOTES <br />0 EXIST. bXb STEEL COLUMN RE: STRUCTURE <br />© EXISTING 4'-0" CANVAS AWNINGS ABOVE STOREFRONT, BURAMY- <br />TO MATCH EXISTING SHOPPING CENTER <br />© EXISTING 4'-0" CANVAS AWNINGS ABOVE STOREFRONT, KWANDY <br />/IVORY STIPPING TO MATCH EXISTING SHOPPING CENTER COLORS <br />® EXISTING TRUELITE ALUMINUM DOORS t STOREFRONTS, COLORS: <br />ALUMINUM ANODIZED TO MATCH EXISTING CENTER GC. PROVIDES <br />NOA'S <br />© EXISTING LEDGESTONE COLUMNS (TYP), OWENS CORNING CULTURED <br />STONE COUNTY LEDGESTONE-CHARDONNAY CSV-2000b <br />® EXISTING CONCRETE LANDING AT EACH DOOR 140 STEP MAX <br />(TYPJ <br />© NEW b" FIRE RATED DEMISING PARTITION. FOR UL ASSEMBLY <br />NUMBER AND DETAILS. SEE SHEET A-40 (TYP) <br />® EXISTING 8" CMU WALL. SEE SHEET A-40 <br />® F-XISTINS -12")(Z4"X24"RI PVC COMPOSITE RECTAWUI-AR PLANTER <br />(WRITE) MODEL: CORONADO PREMIER BY PLANTERS UNLIMITED. SEE <br />M. ON SHEET SP-1 <br />® EXISTINS LANDSCAPE AREA. <br />® EXIS71NO E*OSM SRADE. READY FOR CONCRETE SLAB. <br />FLOOR PLAN LEGEND <br />NEW EXTERIOR WALL <br />DENOTES DOOR NUMBER SEE DOOR SCHEDULE <br />SHEET A -so <br />x DENOTES EXT. WALL TYPE / SECTIONS <br />x OHM A-b0 <br />x�— GENERAL NOTE - SEE LEGEND, THIS SHEET. <br />O DENOTES STOREFRONT / WINDOW NM R, <br />SEE STOREFRONT / WINDOW SCHEDULE <br />SHEET A-80 <br />© Y PLAN <br />r _ --------- r7 Y <br />m <br />�I I <br />'i <br />I E <br />g LTic6ej, <br />. <br />c � n <br />Associates, Inc. AA26001933 <br />Architecture • Planning • Interior Design <br />14125 N.W. 80th Ave. Suite 303 <br />Miami Lakes, Fl. 33016 <br />T. 786-235-9097 <br />F. 305-362-4420 <br />dtiinfo@dtiarchitect.com <br />www.dtiarchitect.com <br />Revisions: <br />Date I Description <br />O <br />M <br />WN fq <br />F <br />A <br />0 <br />-o <br />U <br />U <br />W <br />A <br />rA <br />zID <br />rA W <br />F <br />0 <br />o� <br />Q <br />W <br />A <br />zz <br />Ix <br />q <br />W <br />0 <br />� <br />M <br />M <br />Q <br />U <br />0 <br />z <br />0 <br />a <br />A <br />�a <br />0 <br />A <br />0� <br />a� <br />A <br />�r <br />�r <br />a <br />o <br />>4 <br />a <br />w <br />f�l <br />Q <br />U <br />0 <br />� <br />w <br />� <br />x <br />a <br />Z <br />a <br />N <br />Job Number: <br />14025.01 <br />File name: <br />Issued Date: <br />04.1.14 <br />Drawn by: <br />MCab <br />Checked by: <br />C.P./C.C. <br />SHEET NAME 1 <br />PROPOSED <br />FLOOR PLAN <br />SHEET NUMBER <br />A-200 <br />-A <br />