8" CONCRETE BLOCK <br />3/4" 3-COAT STUCCO. PROVIDE <br />ELASTOMETRIC WATER PROOFING, <br />PRIME t PAINT. COLOR TO BE <br />SELECTED BY OWNER <br />5/8" GYPSUM BOARD ON I x 2 P.T. <br />WOOD FURRING STRIPS 0 16" O.C. <br />8" REINFORCED CONCRETE <br />BLOCK SEE STRUCTURAL <br />DRAWINGS. <br />FOILED BACKED INSULATION. <br />R-43 MIN. <br />WALL TYPE <br />EXPOSED STRUCTURE <br />INSIDE OF BUILDING% <br />EXISTING WALL TYPE A <br />SCALE: V = 1'-0" <br />nonbearing Wall <br />DEMISING PARTITION <br />(OR SIMILAR) <br />Design No. U419 <br />Ratings — 1,2,3 or 4 Hr (See <br />October 27, 2005 <br />Items 3 & 4) <br />R5 <br />5EE ITEM 4 <br />I. FLOOR AND CEILING RUNNERS - (NOT SHOWN) - CHANNEL SHAPED, <br />FABRICATED FROM MIN 25 MSG CORROSION -PROTECTED STEEL, MIN WIDTH TO <br />ACCOMMODATE STUD SIZE, WITH MIN I IN LONG LEGS, ATTAGI$D TO FLOOR <br />AND CEILING WITH FASTENERS 24 IN OC MAX <br />2. STEEL STUDS - CHANNEL SHAPED, FABRICATED FROM MIN 25 MSG <br />CORROSION -PROTECTED STEEL, MIN WIDTH AS INDICATED UNDER ITEM 4, MIN <br />1-1/4 IN. FLANGES AND 1/4 IN. RETURN, SPACED A MAX OF 24 IN. OC. STUDS TO <br />BE CUT 3/8 TO 3/4 IN. LESS THAN ASSEMBLY HEIGHT. <br />3. BATTS AND BLANKETS - (REQUIRED AS INDICATED UNDER ITEM 4) - <br />MINERAL WOOL BATTS, FRICTION FITTED BETWEEN STUDS AND RUNNERS. MIN <br />NOM THICKNESS AS INDICATED UNDER ITEM 4. SEE BATTS AND BLANKETS <br />(BKNV OR BZJZ) CATEGORIES FOR NAMES OF CLASSIFIED COMPANIES. <br />3A BATTS AND BLANKETS* - (OPTIONAL) - PLACED IN STUD CAVITIES, ANY <br />GLASS FIBER OR MINERAL WOOL INSULATION BEARING THE UL CLASSIFICATION <br />MARKING AS TO SURFACE BURNING CHARACTERISTICS AND/OR FIRE <br />RESISTANCE. SEE BATTS AND BLANKETS (BKNV OR BZJZ) CATEGORIES FOR <br />NAMES OF CLASSIFIED COMPANIES. <br />4. GYPSUM BOARD• - GYPSUM PANELS WITH BEVELED, SQUARE OR TAPERED <br />EDGES, APPLIED VERTICALLY OR HORIZONTALLY. VERTICAL JOINTS <br />CENTERED OVER STUDS AND STAGGERED ONE STUD CAVITY ON OPPOSITE <br />SIDES OF STUDS. VERTICAL JOINTS IN ADJACENT LAYERS (MULTILAYER <br />SYSTEMS) STAGGERED ONE STUD CAVITY. HORIZONTAL JOINTS NEED NOT BE <br />BACKED BY STEEL FRAMING. HORIZONTAL EDGE JOINTS AND HORIZONTAL <br />BUTT JOINTS ON OPPOSITE SIDES OF STUDS NEED NOT BE STAGGERED. <br />HORIZONTAL EDGE JOINTS AND HORIZONTAL BUTT JOINTS IN ADJACENT <br />LAYERS (M6LTILAYER SYSTEMS) STAGGERED A MIN OF 12 IN. THE THICKNESS <br />AND NUMBER OF LAYERS FOR THE 1 HR 2 NR, 3 HR AND 4 HR RATINGS ARE AS <br />FOLLOWS: <br />WALLBOARD PROTECTION ON EACH SIDE OF WALL <br />RATING MIN STUD DEPTH NO. OF LAYERS 4 THKNS OF PANEL MIN <br />THKNS OF INSULATION (ITEM 3) <br />OPTIONAL 34 1 LAYER 5/8 IN. THICK <br />IN. 1 2-1 1 LAYER 1/2 IN. THICK <br />1-I/2 <br />OPTIONAL 1-1 1 LAYER, 3/4 IN. THICK <br />OF'TIO IAL A 2 LAYERS, 1/2 IN. THICK <br />OPTIONAL <br />2 A 2 LAYERS, 5/8 IN. THICK <br />2 3-1 1 LAYER, 3/4 IN. THICK <br />3 IN. <br />OPTIONAL 3 LAYERS, 1/2 IN. THICK <br />OPTION AL I-g 2 LAYERS, 3/4 IN. THICK <br />OPTIONAL 3 LAYERS, 5/8 R THICK <br />4 A 4 LAYERS, 5/8 IN. THICK <br />OPTIONAL <br />OPTIOt AL I-� 4 LAYERS, In IN. THICK <br />IN. 4 2-1 2 LAYERS, 3/4 IN. THICK <br />2 <br />CANADIAN GYPSUM COMPANY - 1/2 IN. THICK TYPE C, IF-X2 OR IPC-AR* WRC, <br />5/8 IN. THICK TYPE AR C, IP-AR, IP-X1, IP-X2, [PC -AR SCX, SHX, WRX OR WRCt <br />3/4 IN. THICK TYPES IP-X3 OR ULTRACODE <br />UNITED STATES GYPSUM CO - 1/2 R THICK TYPE C, IP-X2, IPC-AR OR WRCt 5/8 <br />R THICK TYPE SCX, SHK WRX, IP-XI, AR C, WRC, FRX-G, IP-AR, IP-X2, IPC-AR <br />s 3/4 IN. THICK TYPES IP-X3 OR ULTRACODE <br />USG MEXICO S A DE C V - 1/2 IN. THICK TYPE C, IP-X2, IPC-AR OR WRCt 5/8 IN. <br />THICK TYPE AR C, IP-AR IP-XI, IP-X2, IPC-AR SCX, SHK WRX, WRC ORs 3/4 IN. <br />THICK TYPES IP-X3 OR ULTRACODE <br />WHEN ITEM 65, STEEL FRAMING MEMBERS*, IS USED, NON15EARINCI WALL <br />RATING IS LIMITED TO I NR. MIN. STUD DEPTH IS 3-1/2 IN., MIN. THICKNESS <br />OF INSULATION (ITEM 3) IS 3 M AND TWO LAYERS OF GYPSUM BOARD <br />PANELS (1/2 IN. OR 5/8 IN. THICK) SHALL BE ATTACHED TO FURRING <br />CHANNELS AS DESCRIBED IN ITEM 5. ONE LAYER OF GYPSUM BOARD <br />PANELS (1/2 IN. OR 5/8 IN. THICK) ATTACHED TO OPPOSITE SIDE OF STUD <br />WITHOUT FURRING C 4ANONELS AS DESCRIBED IN ITEM 5. <br />44 GYPSUM BOARD* - (AS AN ALTERNATE TO ITEM 4) - 5/8 R THICK. 2 <br />FT. WIDE, TONGUE AND GROOVE EDGE, APPLIED HORIZONTALLY AS THE <br />OUTER LAYER TO ONE SIDE OF THE ASSEMBLY. SECURED AS <br />DESCRIBED IN ITEM S. JOINT COVERING (ITEM 1) NOT REQUIRED. <br />CANADIAN GYPSUM COMPANY - TYPE SHX <br />UNITED STATES GYPSUM CO -TYPE SHX. <br />USG MEXICO S A DE C V - TYPE SHX <br />5. FASTENERS - (NOT SHOWN) - TYPE S OR 5-12 STEEL SCREWS USED TO <br />ATTACH PALLS TO STUDS (ITEM 2) OR FURRING CHANNELS (ITEM 6). <br />SINGLE LAYER SYSTEMS: I IN. LONG FOR 1/2 AND 5/8 IN. THICK PANELS OR <br />1-1/4 IN. LONG FOR 3/4 R THICK PANELS, SPACED 8 IN. OC WHEN PANELS <br />ARE APPLIED HORIZONTALLY, OR S IN. OC ALONG VERTICAL AND <br />BOTTOM EDGES AND 12 R OC IN THE FIELD WHEN PANELS ARE APPLIED <br />VERTICALLY. TWO LAYER SYSTEMS: FIRST LAYER- I IN. LONG FOR 1/2 AND <br />5/8 IN. THICK PANELS OR 1-1/4 IN. LONG FOR 3/4 IN. THICK PANELS, <br />SPACED 16 IN. OC. SECOND LAYER- 1-5/8 IN. LONG FOR V2 IN., 5/8 IN. <br />THICK PANELS OR 2-1/4 X LONG FOR 3/4 K THICK PANELS, SPACED 16 R <br />OC WITH SCREWS OFFSET 8 IN. FROM FIRST LAYER THREE -LAYER <br />SYSTEMS: FIRST LAYER- 1 R LONG FOR 1/2 IN, 5/8 IN. THICK PANELS, <br />SPACED 24 IN. OC. SECOND LAYER- 1-5/8 IN. LONG FOR 1/2 K 5/8 IN. <br />THICK PANELS, SPACED 24 IN. OC. THIRD LAYER- 2-1/4 IN. LONG FOR 1/2 K <br />5/8 IN. THICK PANELS OR 2-5/8 R LONG FOR 5/8 R THICK PANELS, <br />SPACED 12 R OC. SCREWS OFFSET MIN 6 IN. FROM LAYER BELOW. <br />FOUR -LAYER SYSTEMS: FIRST LAYER- I IN. LONG FOR 1/2 IN, 5/8 IN. THICK <br />PANELS, SPACED 24 X OC. SECOND LAYER- 1-5/8 R LONG FOR in K 5/8 <br />IN. THICK PANELS, SPACED 24 IN. OC. THIRD LAYER- 2-1/4 R LONG FOR 1/2 <br />IN. THICK PANELS OR 2-5/8 IN. LONG FOR 5/8 R THICK PANELS, SPACED <br />24 IN. OC. FOURTH LAYER- 2-5/8 IN. LONG FOR In R THICK PANELS OR 3 <br />IN. LONG FOR 5/8 IN. THICK PANELS, SPACED 12 IN. OC. SCREWS OFFSET MIN <br />6 IN. FROM LAYER BELOW. <br />6. FURRING CHANNELS - (OPTIONAL, NOT SHOWN, FOR SINGLE OR DOUBLE <br />LAYER SYSTEMS) - RESILIENT FURRING CHANNELS FABRICATED FROM MIN <br />25 MSG CORROSION -PROTECTED STEEL, SPACED VERTICALLY A MAX OF <br />24 IN. OC. FLANGE PORTION ATTACHED TO EACH INTERSECTING STUD WITH <br />1/2 IN. LONG TYPE 8-12 STEEL SCREWS. NOT FOR USE WITH ITEM 4A. <br />6A STEEL FRAMING MEMBERS (NOT SHOWN), - (OPTIONAL ON ONE OR <br />BOTH SIDES, NOT SHOWN, FOR SINGLE OR DOUBLE LAYER SYSTEMS) - AS <br />AN ALTERNATE TO ITEM 6, FURRING CHANNELS AND STEEL FRAMING <br />MEMBERS AS DESCRIBED BELOW: <br />A FURRING CHANNELS - FORMED OF NO. 25 MSG GALV STEEL. <br />2-3/8 K WIDE BY 1/8 IN. DEEP, SPACED MAX 24 IN. OC <br />PERPENDICULAR TO STUDS. CHANNELS SECURED TO STUDS AS <br />DESCRIBED IN ITEM B. GYPSUM BOARD ATTACHED TO FURRING <br />CHANNELS AS DESCRIBED IN ITEM 5. NOT FOR USE WITH ITEM <br />4A <br />B. STEEL FRAMING MEMBERS* - USED TO ATTACH FURRING <br />CHANNELS (ITEM 6AA) TO STUDS (ITEM 2). CLIPS SPACED MAX. <br />48 IN. OC, AND SECURED TO STUDS WITH NO. 8 X 1-1/2 R <br />MINIMUM SELF -DRILLING, 8-12 STEEL SCREW THROUGH THE <br />CENTER GROMMET. FURRING CHANNELS ARE FRICTION FITTED <br />INTO CLIPS. <br />PAC INTERNATIONAL INC - TYPE RSIC-1. <br />615. STEEL FRAMING MEMBERS (OPTIONAL, NOT SHOWN), - AS AN <br />ALTERNATE TO ITEM 6, FURRING CHANNELS AND STEEL FRAMING <br />MEMBERS ON ONLY ONE SIDE OF STUDS AS DESCRIBED BELOW: <br />A FURRING CHANNELS - FORMED OF NO. 25 MSG GALV STEEL, <br />SPACED 24 IN. OC PERPENDICULAR TO STUDS. CHANNELS <br />SECURED TO STUDS AS DESCRIBED IN ITEM B. BATTS AND <br />BLANKETS PLACED IN STUD CAVITY AS DESCRIBED IN ITEM 4. <br />TWO LAYERS OF GYPSUM BOARD ATTACHED TO FURRING <br />CHANNELS AS DESCRIBED IN ITEM 4. NOT FOR USE WITH ITEM <br />4A <br />B. STEEL FRAMING MEMBERS• - USED TO ATTACH FURRING <br />CHANNELS (ITEM 65A) TO ONE SIDE OF STUDS (ITEM 2) ONLY. <br />CLIPS SPACED 48 R OC, AND SECURED TO STUDS WITH TWO <br />NO. 8 X 2-1/2 IN. COARSE DRYWALL SCREWS, ONE THROUGH THE <br />HOLE AT EACH END OF TIME CLIP. FURRING C 4ANpNELS ARE <br />FRICTION FITTED INTO CLIPS. <br />KINETICS NOISE CONTROL INC -TYPE ISOMAX <br />1. JOINT TAPE AND COMPOUND - VINYL OR CASEIN, DRY OR PREMIXED <br />JOINT COMPOUND APPLIED IN TWO COATS TO JOINTS AND SCREW HEADS <br />OF OUTER LAYERS. PAPER TAPE, NOM 2 IN. WIDE, EMBEDDED IN FIRST <br />LAYER OF COMPOUND OVER ALL JOINTS OF OUTER LAYER PANELS. <br />PAPER TAPE AND JOINT COMPOUND MAY BE OMITTED WHEN GYPSUM <br />PANELS ARE SUPPLIED WITH A SQUARE EDGE. <br />8 SIDING, BRICK OR STUCCO - (OPTIONAL, NOT SHOWN) - ALUMINUM, VINYL <br />OR STEEL SIDING, BRICK VENEER OR STUCCO, MEETING THE <br />REQUIREMENTS OF LOCAL CODE AGENCIES, INSTALLED OVER GYPSUM <br />PANELS. BRICK VENEER ATTACHED TO STUDS WITH CORRNXsATED METAL <br />WALL TIES ATTACHED TO EACH STUD WITH STEEL SCREWS, NOT MORE <br />THAN EACH SIXTH COURSE OF BRICK <br />9. CAULKING AND SEALANTS, - (OPTIONAL, NOT SHOWN) - A BEAD OF <br />ACOUSTICAL SEALANT APPLIED AROUND THE PARTITION PERIMETER FOR <br />SOUND CONTROL. <br />UNITED STATES GYPSUM CO - TYPE AS <br />M <br />Ig Tec <br />a n <br />Associates, Inc. AA26001933 <br />Architecture * Planning * Interior Design <br />14125 N.W. 80th Ave. 'Suite 303 <br />Miami Lakes, R. 33016 <br />T. 786-235-9097 <br />F. 305-362-4420 <br />dtiinio@dtiarchitect.com <br />www.dbarchitect.com <br />11 ElmR 00> 079 R.A. I I <br />Date I Description <br />O <br />C7 <br />G <br />� <br />F O <br />W <br />U <br />A <br />rA <br />rA W <br />Z <br />E, m <br />U <br />w <br />� <br />U <br />CD W <br />Q <br />w <br />W <br />� <br />A <br />Z <br />w <br />O <br />V'1 <br />M <br />M <br />0 <br />U <br />rh <br />V <br />0 <br />a <br />Q <br />o <br />a� <br />0j <br />Z <br />o <br />a� <br />°Ix <br />a <br />U <br />o <br />U <br />w <br />N <br />M <br />� <br />x <br />rA <br />x <br />N <br />Job Number: <br />14025.01 <br />File name: <br />Issued Date: <br />04.1.14 <br />Drawn by: <br />MCab <br />Checked by: <br />C.P./C.C. <br />SHEET NAME <br />WALL <br />ppTYPES <br />OIL. <br />DETAILS <br />DEMISING PARTITION B. <br />SCALE: 1/2" = 1'-0" <br />SHEET NUMBER <br />A-400 <br />