8" CONCRETE BLOCK
<br />3/4" 3-COAT STUCCO. PROVIDE
<br />ELASTOMETRIC WATER PROOFING,
<br />PRIME t PAINT. COLOR TO BE
<br />SELECTED BY OWNER
<br />5/8" GYPSUM BOARD ON I x 2 P.T.
<br />WOOD FURRING STRIPS 0 16" O.C.
<br />8" REINFORCED CONCRETE
<br />BLOCK SEE STRUCTURAL
<br />DRAWINGS.
<br />FOILED BACKED INSULATION.
<br />R-43 MIN.
<br />WALL TYPE
<br />EXPOSED STRUCTURE
<br />INSIDE OF BUILDING%
<br />EXISTING WALL TYPE A
<br />SCALE: V = 1'-0"
<br />nonbearing Wall
<br />DEMISING PARTITION
<br />(OR SIMILAR)
<br />Design No. U419
<br />Ratings — 1,2,3 or 4 Hr (See
<br />October 27, 2005
<br />Items 3 & 4)
<br />R5
<br />5EE ITEM 4
<br />I. FLOOR AND CEILING RUNNERS - (NOT SHOWN) - CHANNEL SHAPED,
<br />FABRICATED FROM MIN 25 MSG CORROSION -PROTECTED STEEL, MIN WIDTH TO
<br />ACCOMMODATE STUD SIZE, WITH MIN I IN LONG LEGS, ATTAGI$D TO FLOOR
<br />AND CEILING WITH FASTENERS 24 IN OC MAX
<br />2. STEEL STUDS - CHANNEL SHAPED, FABRICATED FROM MIN 25 MSG
<br />CORROSION -PROTECTED STEEL, MIN WIDTH AS INDICATED UNDER ITEM 4, MIN
<br />1-1/4 IN. FLANGES AND 1/4 IN. RETURN, SPACED A MAX OF 24 IN. OC. STUDS TO
<br />BE CUT 3/8 TO 3/4 IN. LESS THAN ASSEMBLY HEIGHT.
<br />3. BATTS AND BLANKETS - (REQUIRED AS INDICATED UNDER ITEM 4) -
<br />MINERAL WOOL BATTS, FRICTION FITTED BETWEEN STUDS AND RUNNERS. MIN
<br />NOM THICKNESS AS INDICATED UNDER ITEM 4. SEE BATTS AND BLANKETS
<br />(BKNV OR BZJZ) CATEGORIES FOR NAMES OF CLASSIFIED COMPANIES.
<br />3A BATTS AND BLANKETS* - (OPTIONAL) - PLACED IN STUD CAVITIES, ANY
<br />GLASS FIBER OR MINERAL WOOL INSULATION BEARING THE UL CLASSIFICATION
<br />MARKING AS TO SURFACE BURNING CHARACTERISTICS AND/OR FIRE
<br />RESISTANCE. SEE BATTS AND BLANKETS (BKNV OR BZJZ) CATEGORIES FOR
<br />NAMES OF CLASSIFIED COMPANIES.
<br />4. GYPSUM BOARD• - GYPSUM PANELS WITH BEVELED, SQUARE OR TAPERED
<br />EDGES, APPLIED VERTICALLY OR HORIZONTALLY. VERTICAL JOINTS
<br />CENTERED OVER STUDS AND STAGGERED ONE STUD CAVITY ON OPPOSITE
<br />SIDES OF STUDS. VERTICAL JOINTS IN ADJACENT LAYERS (MULTILAYER
<br />SYSTEMS) STAGGERED ONE STUD CAVITY. HORIZONTAL JOINTS NEED NOT BE
<br />BACKED BY STEEL FRAMING. HORIZONTAL EDGE JOINTS AND HORIZONTAL
<br />BUTT JOINTS ON OPPOSITE SIDES OF STUDS NEED NOT BE STAGGERED.
<br />HORIZONTAL EDGE JOINTS AND HORIZONTAL BUTT JOINTS IN ADJACENT
<br />LAYERS (M6LTILAYER SYSTEMS) STAGGERED A MIN OF 12 IN. THE THICKNESS
<br />AND NUMBER OF LAYERS FOR THE 1 HR 2 NR, 3 HR AND 4 HR RATINGS ARE AS
<br />FOLLOWS:
<br />WALLBOARD PROTECTION ON EACH SIDE OF WALL
<br />RATING MIN STUD DEPTH NO. OF LAYERS 4 THKNS OF PANEL MIN
<br />THKNS OF INSULATION (ITEM 3)
<br />OPTIONAL 34 1 LAYER 5/8 IN. THICK
<br />IN. 1 2-1 1 LAYER 1/2 IN. THICK
<br />1-I/2
<br />OPTIONAL 1-1 1 LAYER, 3/4 IN. THICK
<br />OF'TIO IAL A 2 LAYERS, 1/2 IN. THICK
<br />OPTIONAL
<br />2 A 2 LAYERS, 5/8 IN. THICK
<br />2 3-1 1 LAYER, 3/4 IN. THICK
<br />3 IN.
<br />OPTIONAL 3 LAYERS, 1/2 IN. THICK
<br />OPTION AL I-g 2 LAYERS, 3/4 IN. THICK
<br />OPTIONAL 3 LAYERS, 5/8 R THICK
<br />4 A 4 LAYERS, 5/8 IN. THICK
<br />OPTIONAL
<br />OPTIOt AL I-� 4 LAYERS, In IN. THICK
<br />IN. 4 2-1 2 LAYERS, 3/4 IN. THICK
<br />2
<br />CANADIAN GYPSUM COMPANY - 1/2 IN. THICK TYPE C, IF-X2 OR IPC-AR* WRC,
<br />5/8 IN. THICK TYPE AR C, IP-AR, IP-X1, IP-X2, [PC -AR SCX, SHX, WRX OR WRCt
<br />3/4 IN. THICK TYPES IP-X3 OR ULTRACODE
<br />UNITED STATES GYPSUM CO - 1/2 R THICK TYPE C, IP-X2, IPC-AR OR WRCt 5/8
<br />R THICK TYPE SCX, SHK WRX, IP-XI, AR C, WRC, FRX-G, IP-AR, IP-X2, IPC-AR
<br />s 3/4 IN. THICK TYPES IP-X3 OR ULTRACODE
<br />USG MEXICO S A DE C V - 1/2 IN. THICK TYPE C, IP-X2, IPC-AR OR WRCt 5/8 IN.
<br />THICK TYPE AR C, IP-AR IP-XI, IP-X2, IPC-AR SCX, SHK WRX, WRC ORs 3/4 IN.
<br />THICK TYPES IP-X3 OR ULTRACODE
<br />WHEN ITEM 65, STEEL FRAMING MEMBERS*, IS USED, NON15EARINCI WALL
<br />RATING IS LIMITED TO I NR. MIN. STUD DEPTH IS 3-1/2 IN., MIN. THICKNESS
<br />OF INSULATION (ITEM 3) IS 3 M AND TWO LAYERS OF GYPSUM BOARD
<br />PANELS (1/2 IN. OR 5/8 IN. THICK) SHALL BE ATTACHED TO FURRING
<br />CHANNELS AS DESCRIBED IN ITEM 5. ONE LAYER OF GYPSUM BOARD
<br />PANELS (1/2 IN. OR 5/8 IN. THICK) ATTACHED TO OPPOSITE SIDE OF STUD
<br />WITHOUT FURRING C 4ANONELS AS DESCRIBED IN ITEM 5.
<br />44 GYPSUM BOARD* - (AS AN ALTERNATE TO ITEM 4) - 5/8 R THICK. 2
<br />FT. WIDE, TONGUE AND GROOVE EDGE, APPLIED HORIZONTALLY AS THE
<br />OUTER LAYER TO ONE SIDE OF THE ASSEMBLY. SECURED AS
<br />DESCRIBED IN ITEM S. JOINT COVERING (ITEM 1) NOT REQUIRED.
<br />CANADIAN GYPSUM COMPANY - TYPE SHX
<br />UNITED STATES GYPSUM CO -TYPE SHX.
<br />USG MEXICO S A DE C V - TYPE SHX
<br />5. FASTENERS - (NOT SHOWN) - TYPE S OR 5-12 STEEL SCREWS USED TO
<br />ATTACH PALLS TO STUDS (ITEM 2) OR FURRING CHANNELS (ITEM 6).
<br />SINGLE LAYER SYSTEMS: I IN. LONG FOR 1/2 AND 5/8 IN. THICK PANELS OR
<br />1-1/4 IN. LONG FOR 3/4 R THICK PANELS, SPACED 8 IN. OC WHEN PANELS
<br />ARE APPLIED HORIZONTALLY, OR S IN. OC ALONG VERTICAL AND
<br />BOTTOM EDGES AND 12 R OC IN THE FIELD WHEN PANELS ARE APPLIED
<br />VERTICALLY. TWO LAYER SYSTEMS: FIRST LAYER- I IN. LONG FOR 1/2 AND
<br />5/8 IN. THICK PANELS OR 1-1/4 IN. LONG FOR 3/4 IN. THICK PANELS,
<br />SPACED 16 IN. OC. SECOND LAYER- 1-5/8 IN. LONG FOR V2 IN., 5/8 IN.
<br />THICK PANELS OR 2-1/4 X LONG FOR 3/4 K THICK PANELS, SPACED 16 R
<br />OC WITH SCREWS OFFSET 8 IN. FROM FIRST LAYER THREE -LAYER
<br />SYSTEMS: FIRST LAYER- 1 R LONG FOR 1/2 IN, 5/8 IN. THICK PANELS,
<br />SPACED 24 IN. OC. SECOND LAYER- 1-5/8 IN. LONG FOR 1/2 K 5/8 IN.
<br />THICK PANELS, SPACED 24 IN. OC. THIRD LAYER- 2-1/4 IN. LONG FOR 1/2 K
<br />5/8 IN. THICK PANELS OR 2-5/8 R LONG FOR 5/8 R THICK PANELS,
<br />SPACED 12 R OC. SCREWS OFFSET MIN 6 IN. FROM LAYER BELOW.
<br />FOUR -LAYER SYSTEMS: FIRST LAYER- I IN. LONG FOR 1/2 IN, 5/8 IN. THICK
<br />PANELS, SPACED 24 X OC. SECOND LAYER- 1-5/8 R LONG FOR in K 5/8
<br />IN. THICK PANELS, SPACED 24 IN. OC. THIRD LAYER- 2-1/4 R LONG FOR 1/2
<br />IN. THICK PANELS OR 2-5/8 IN. LONG FOR 5/8 R THICK PANELS, SPACED
<br />24 IN. OC. FOURTH LAYER- 2-5/8 IN. LONG FOR In R THICK PANELS OR 3
<br />IN. LONG FOR 5/8 IN. THICK PANELS, SPACED 12 IN. OC. SCREWS OFFSET MIN
<br />6 IN. FROM LAYER BELOW.
<br />6. FURRING CHANNELS - (OPTIONAL, NOT SHOWN, FOR SINGLE OR DOUBLE
<br />LAYER SYSTEMS) - RESILIENT FURRING CHANNELS FABRICATED FROM MIN
<br />25 MSG CORROSION -PROTECTED STEEL, SPACED VERTICALLY A MAX OF
<br />24 IN. OC. FLANGE PORTION ATTACHED TO EACH INTERSECTING STUD WITH
<br />1/2 IN. LONG TYPE 8-12 STEEL SCREWS. NOT FOR USE WITH ITEM 4A.
<br />6A STEEL FRAMING MEMBERS (NOT SHOWN), - (OPTIONAL ON ONE OR
<br />BOTH SIDES, NOT SHOWN, FOR SINGLE OR DOUBLE LAYER SYSTEMS) - AS
<br />AN ALTERNATE TO ITEM 6, FURRING CHANNELS AND STEEL FRAMING
<br />MEMBERS AS DESCRIBED BELOW:
<br />A FURRING CHANNELS - FORMED OF NO. 25 MSG GALV STEEL.
<br />2-3/8 K WIDE BY 1/8 IN. DEEP, SPACED MAX 24 IN. OC
<br />PERPENDICULAR TO STUDS. CHANNELS SECURED TO STUDS AS
<br />DESCRIBED IN ITEM B. GYPSUM BOARD ATTACHED TO FURRING
<br />CHANNELS AS DESCRIBED IN ITEM 5. NOT FOR USE WITH ITEM
<br />4A
<br />B. STEEL FRAMING MEMBERS* - USED TO ATTACH FURRING
<br />CHANNELS (ITEM 6AA) TO STUDS (ITEM 2). CLIPS SPACED MAX.
<br />48 IN. OC, AND SECURED TO STUDS WITH NO. 8 X 1-1/2 R
<br />MINIMUM SELF -DRILLING, 8-12 STEEL SCREW THROUGH THE
<br />CENTER GROMMET. FURRING CHANNELS ARE FRICTION FITTED
<br />INTO CLIPS.
<br />PAC INTERNATIONAL INC - TYPE RSIC-1.
<br />615. STEEL FRAMING MEMBERS (OPTIONAL, NOT SHOWN), - AS AN
<br />ALTERNATE TO ITEM 6, FURRING CHANNELS AND STEEL FRAMING
<br />MEMBERS ON ONLY ONE SIDE OF STUDS AS DESCRIBED BELOW:
<br />A FURRING CHANNELS - FORMED OF NO. 25 MSG GALV STEEL,
<br />SPACED 24 IN. OC PERPENDICULAR TO STUDS. CHANNELS
<br />SECURED TO STUDS AS DESCRIBED IN ITEM B. BATTS AND
<br />BLANKETS PLACED IN STUD CAVITY AS DESCRIBED IN ITEM 4.
<br />TWO LAYERS OF GYPSUM BOARD ATTACHED TO FURRING
<br />CHANNELS AS DESCRIBED IN ITEM 4. NOT FOR USE WITH ITEM
<br />4A
<br />B. STEEL FRAMING MEMBERS• - USED TO ATTACH FURRING
<br />CHANNELS (ITEM 65A) TO ONE SIDE OF STUDS (ITEM 2) ONLY.
<br />CLIPS SPACED 48 R OC, AND SECURED TO STUDS WITH TWO
<br />NO. 8 X 2-1/2 IN. COARSE DRYWALL SCREWS, ONE THROUGH THE
<br />HOLE AT EACH END OF TIME CLIP. FURRING C 4ANpNELS ARE
<br />FRICTION FITTED INTO CLIPS.
<br />KINETICS NOISE CONTROL INC -TYPE ISOMAX
<br />1. JOINT TAPE AND COMPOUND - VINYL OR CASEIN, DRY OR PREMIXED
<br />JOINT COMPOUND APPLIED IN TWO COATS TO JOINTS AND SCREW HEADS
<br />OF OUTER LAYERS. PAPER TAPE, NOM 2 IN. WIDE, EMBEDDED IN FIRST
<br />LAYER OF COMPOUND OVER ALL JOINTS OF OUTER LAYER PANELS.
<br />PAPER TAPE AND JOINT COMPOUND MAY BE OMITTED WHEN GYPSUM
<br />PANELS ARE SUPPLIED WITH A SQUARE EDGE.
<br />8 SIDING, BRICK OR STUCCO - (OPTIONAL, NOT SHOWN) - ALUMINUM, VINYL
<br />OR STEEL SIDING, BRICK VENEER OR STUCCO, MEETING THE
<br />REQUIREMENTS OF LOCAL CODE AGENCIES, INSTALLED OVER GYPSUM
<br />PANELS. BRICK VENEER ATTACHED TO STUDS WITH CORRNXsATED METAL
<br />WALL TIES ATTACHED TO EACH STUD WITH STEEL SCREWS, NOT MORE
<br />THAN EACH SIXTH COURSE OF BRICK
<br />9. CAULKING AND SEALANTS, - (OPTIONAL, NOT SHOWN) - A BEAD OF
<br />ACOUSTICAL SEALANT APPLIED AROUND THE PARTITION PERIMETER FOR
<br />SOUND CONTROL.
<br />UNITED STATES GYPSUM CO - TYPE AS
<br />M
<br />Ig Tec
<br />a n
<br />Associates, Inc. AA26001933
<br />Architecture * Planning * Interior Design
<br />14125 N.W. 80th Ave. 'Suite 303
<br />Miami Lakes, R. 33016
<br />T. 786-235-9097
<br />F. 305-362-4420
<br />dtiinio@dtiarchitect.com
<br />www.dbarchitect.com
<br />11 ElmR 00> 079 R.A. I I
<br />Date I Description
<br />O
<br />C7
<br />G
<br />�
<br />F O
<br />W
<br />U
<br />A
<br />rA
<br />rA W
<br />Z
<br />E, m
<br />U
<br />w
<br />�
<br />U
<br />CD W
<br />Q
<br />w
<br />W
<br />�
<br />A
<br />Z
<br />w
<br />O
<br />V'1
<br />M
<br />M
<br />0
<br />U
<br />rh
<br />V
<br />0
<br />a
<br />Q
<br />o
<br />a�
<br />0j
<br />Z
<br />o
<br />a�
<br />°Ix
<br />a
<br />U
<br />o
<br />U
<br />w
<br />N
<br />M
<br />�
<br />x
<br />rA
<br />x
<br />N
<br />Job Number:
<br />14025.01
<br />File name:
<br />Issued Date:
<br />04.1.14
<br />Drawn by:
<br />MCab
<br />Checked by:
<br />C.P./C.C.
<br />SHEET NAME
<br />WALL
<br />ppTYPES
<br />OIL.
<br />DETAILS
<br />DEMISING PARTITION B.
<br />SCALE: 1/2" = 1'-0"
<br />SHEET NUMBER
<br />A-400