W.( <br />WATT <br />WATT <br />PER <br />DOMESTIC WATER RISER PLAN <br />PLAN NOTES <br />EXTEND AND <br />CONNECT <br />TO EXISTING <br />1 <br />0 <br />UNDERGROUND <br />SANITARY PIPING. <br />FIELD VERIFY <br />EXISTING <br />PIPE LOCATION. <br />O <br />EXTEND AND <br />CONNECT <br />TO EXISTING VENT PIPE. <br />FIELD VERIFY <br />EXISTING <br />PIPE LOCATION. <br />O <br />EXTEND AND <br />CONNECT <br />TO 2" DOMESTIC WATER LINE. <br />FIELD VERIFY <br />EXISTING <br />PIPE LOCATION. <br />® <br />NEW 30 GL ELECTRIC <br />WATER TANK. <br />NOT TO SCALE <br />GREASE WASTE PIPE <br />SANITARY WASTE PIPE <br />►fx0mmIwIIto] <br />COLD WATER PIPING <br />HOT WATER PIPE <br />WALL CLEANOUT <br />FLOOR CLEANOUT <br />VENT THRU ROOF <br />GATE VALVE <br />—«R—-— -— -— - —cR—-— <br />(D WCL <br />0 FC <br />JL <br />IN <br />NOTE: TRAP PRIMER VALVE WILL BE INSTALLED <br />IN ACCORDANCE TO SECTION 1002.4 OF THE FLORIDA BUILDING <br />CODE PLUMBING <br />ZURN #Z2415B OR EQUAL <br />FLOOR DRAIN <br />DEEP SEAL P—TRAP <br />ZURN #Z-1000 OR E( <br />1 - FLOOR DRAIN DETAIL <br />NOT TO SCALE <br />140' <br />TO 3 COMP SINK <br />VACUUM <br />BREAKER <br />C.W. SUPPLY <br />CHECK VALVE <br />110' <br />H.W. SUPPLY <br />HEAT TRAP <br />BALL VALVE <br />MIXING VALVE <br />TEMP. AND PRESSURE <br />RELIEF VALVE <br />WATER HEATER <br />RELIEF DISCHARGE <br />PIPE TO FLOOR <br />MOUNTED MOP SINK <br />PROVIDE 6" MIN. AIR GAP <br />qw <br />3-5/8" 20 GA. METAL STUDS <br />SHUT OFF VALVE <br />TANK DRAIN <br />TYP. <br />DRAIN PAN MIN. 1Y2" <br />FIRE RATED PLYWOOD <br />O O <br />O <br />FIRE RATED WOOD <br />SOLID BLOCKING <br />• <br />2"X2" 18 GA. UNI—STRUT <br />3/8" 0 LAG SCREW @ 6" O.C. <br />OVERFLOW DRIAN PIPE <br />TO FLOOR MOUNTED <br />MOP SINK (DIA. TO <br />MATCH RELIEF VALVE) <br />PROVIDE 6" MIN. AIR GAP <br />NOTES: <br />1. STORAGE WATER HEATER <br />SYSTEMS THAT DO NOT INCLUDE A <br />CIRCULATING <br />SYSTEM SHALL HAVE A HEAT TRAP ON <br />THE HOT AND COLD WATER LINES <br />2. DRAIN PAN <br />SHALL BE 5" <br />LARGER THAN THE TANK DIA. <br />2 -WATER <br />HEATER <br />DETAIL <br />NOT TO SCALE <br />NOTE: ALL PLUMBING WORK TO CONFORM TO 2010 EDITION OF FLORIDA BUILDING CODE - PLUMBING. <br />1.) ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH <br />APPUCABLE LOCAL CODES, RULES AND ORDINANCES. <br />2.) PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE <br />HIMSELF WITH ALL EXISTING CONDITIONS. <br />3.) ALL MATERIALS SHALL BE NEW. <br />4.) ALL WORK SHALL BE PERFORMED BY A UCENSED PLUMBING CONTRACTOR IN A FIRST <br />CLASS WORKMALIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. <br />ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION <br />SHALL BE A PART OF THIS CONTRACT. <br />5.) REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR <br />PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION <br />OF THE WORK. <br />6.) PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, <br />INSPECTION <br />AND TEST, PLUMBING CONTRACTOR TO OBTAIN PERMIT AND APPROVED SUBMITTLES <br />PRIOR TO BEGINING WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST <br />BE PRESENT FOR <br />ALL INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES. <br />7.) DRAWINGS ARE DIAGRAMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, <br />PIPING, EQUIPMENT, ETC. <br />8.) ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE <br />WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPTANCY TO ENGINEER / <br />ARCHITECT PRIOR TO BEGINING CONSTRUCTION. <br />9.) VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERTS OF ALL EXISTING UTILITIES <br />PRIOR TO BEGINING OF CONSTRUCTION. ADVISE ENGINEER/ARCHITECT OF ANY <br />DISCREPANCIES. <br />10.) WATER PIPING ABOVE & BELOW GRADE SHALL BE CPVC. <br />11.) SOIL, WASTE, VENT AND RAINWATER PIPING SHALL BE CAST IRON OR P.V.C. <br />PVC MAY NOT BE USED THRU RATED ASSEMBUES OR IN PLENUMS. <br />12.) ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS AN <br />APPROPRIATLEY MARKED ACCESS PANELS, COORDINATE LOCATIONS WITH THE GENERAL <br />CONTRACTOR PRIOR TO INSTALLATION, <br />13.) FURNISH AND INSTALL APPROVED AIR CHAMBERS AT EACH PLUMBING FIXTURE GROUP <br />AS PER CODE AND WITH GOOD ENGINEERING PRACTICE. <br />14.) DIELECTRIC COUPLING ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND <br />EQUIPMENT CONNECTIONS EXCEPT AT WATER HEATER AS PER CODE. <br />15.) RESERVE. <br />16.) ALL ARE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED <br />FROM FIRE, SMOKE AND WATER PENETRATIONS BY FILLING VOIDS BETWEEN PIPE AND <br />WALL, FLOOR SLEEVES WITH FIRE RATED FOAM TO ACHIEVE THE SAME RATING AS <br />WALLS OR FLOORS AS PART OF THE PLUMBERS WORK. <br />17.) PLUMBING CON CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP <br />FREE FROM DEFECTS FOR A PERIOD OF NO LESS THAN (1) ONE YEAR FROM THE DATE OF <br />ACCEPTANCE BY OWNER CORRECTION OF ANY DEFECTS SHALL BE COMPLETED <br />WITHOUT ADDITIONAL CHARGE WITHIN 72 HRS OF NOTiFiCATION AND SHALL INCLUDE <br />REPLACEMENT OR REPAIR OF ANYM OTHER PHASE OF INSTALLATION WHICH MAY HAVE <br />BEEN DAMAGED. <br />18.) PROViDE CHROM PLATED COMBINATiON COVER PLATE AND CLEANOUT PLUG OR <br />ACCESS <br />PANEL FOR ALL WALL CLEANOUTS, <br />19.) NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES <br />WHERE USED AS RETURN AIR PLENUMS. <br />20.) NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR <br />EQUIPMENT ROOMS. <br />21.) CONDENSATE DRAIN LINES TO BE RUN UNDER SLAB IN P.V.C. SCH40 PIPE AND STUBBED <br />OUT OF WALL TO UNIT. TIE IN OF A/C TO BE BY OTHERS. P.V.C. PIPING WITh 1/2" THICK <br />ARAFLEX INSULATiON MAY BE USED IN LOCATIONS WHERE ALLOWED BY LOCAL CODES. <br />SEE PLUMBING DRAWINGS FOR SIZE AND LOCATION OF PIPING. P.V.C. WILL BE MIN. <br />SCHEDULE 40 PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR <br />INDIVIDUAL SHUT OFF. CONDENSATE REMOVEAL SHALL COMPLY WITH SECTION 307 OF FBCM <br />22.) WATER PIPING INSULATION SHALL BE 10 THICK ARMAPLEX INSTALLED IN ACCORDANCE WITH <br />MANUFACTURES INSTRUCTIONS FOR ALL HOT WATER PPING. WHERE DOMESTIC WATER <br />TEMPERATURES CAN CAUSE SWEATING ALL COLD WATER PIPING SHALL BE INSULATED <br />WITH 1/20 THICK ARMAPLEX INSULATION. <br />23.) STUDOR MINI/MAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO VENT <br />PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL CODES, <br />INSTALLATION SHALL BE AS PER MANUFACTURERS RECOMMENDATIONS, <br />SAMUEL <br />OLMEDO <br />ARCHITECT <br />FL. REG. AR0015027 <br />TEL. 407. 967. 3109 <br />soarcht @ yahoo.com <br />P.O. BOX 784825 <br />WINTER GARDEN, FL. 34778 <br />CONSULTANT <br />CONSULTANT <br />REVISIONS: <br />NO . DATE DESCRIPTION <br />INSTRUMENTS OF SERVICE OWNERSHIP <br />ALL REPORTS, PLANS, SPECIFICATIONS, <br />COMPUTER FILES, FIELD DATA, NOTES <br />INSTRUMENTS PREPARED BY THE <br />AND OTHER DOCUMENTS AND RELATED <br />INSTRUMENTS PREPARED BY THE <br />ARCHITECT OR CONSULTANTS AS <br />INTRUMENTS OF SERVICE SHALL REMAIN <br />THE PROPERTY OF THE ARCHITECT OR <br />CONSULTANT. THE ARCHITECT AND OR <br />THE CONSULTANT SHALL RETAIN ALL <br />COMMON LAW, STATUTORY AND OTHER <br />RESERVED RIGHTS, INCLUDING THE <br />COPYRIGHT THERETO. <br />MR. RANDY HAGAR <br />MR. JOSHUA LINCOLN <br />M0 � <br />. <br />suss <br />ZEPHYR COMMONS <br />SHOPPING CENTER <br />7890 H WY 301 <br />ZEPHYRHILLS FLORIDA <br />DOMESTIC WATER <br />RISER <br />P2 <br />NUMBER <br />?1.1 <br />ELOLMEDO <br />AR0015027 <br />----T--FT---T- I I f f <br />