Laserfiche WebLink
Iw <br />SIDEWALK CURB <br />- - - - - - - - - <br />I11 1 /2"0 <br />WATER LINE <br />& HOSE BI B <br />3'-8 <br />C/) <br />C/) <br />cl-) <br />cf) <br />O <br />O <br />O <br />O <br />Q <br /><c <br /><c <br />a <br />m <br />m <br />m <br />m <br />wl wl wl w <br />w w w w <br />0 <br />N R TU <br />o <br />STEEL GIRDER TRUSS <br />24'-0 3/8" <br />2- 13 "0 <br />PVC FOR <br />4'-3 3/8" I ELECTRICAL <br />I <br />I <br />I I <br />I <br />RF:-^AOVE FLQURSCENT ITS. , Q <br />I I I <br />I I I Of <br />0 <br />rig <br />EMOVE FL URSCENT L S. <br />I <br />1 -2" 3'-4" 10 -0" <br />I I I I I <br />Ki4 <br />- - - - - - - - - - - - - - - - - - - - - - <br />I <br />I <br />24'-7 1 /2" <br />- - - - - - - - - - - - - - - - - - - - - - - J <br />FLOOR PLAN -EXISTING <br />\_ LEASABLE GROSS AREA - 1,600 S.F. <br />0 <br />I <br />CV <br />6"k6" STL <br />1 /4" = 1'-0" <br />00 <br />I <br />(V <br />COL. <br />GENERAL NOTES - <br />DIVISION 1 GENERAL REQUIREMENTS <br />1. THE INTENT OF THESE DOCUMENTS IS TO PROVIDE FOR THE CONSTRUCTION OF THIS <br />PROJECT, COMPLETE AND FUNCTIONAL IN ALL RESPECTS. THE .CONTRACTOR SHALL BE <br />RESPONSIBLE FOR THIS RESULT. THE OMISSION OF EXPRESS REFERENCE TO WORK <br />NECESSARY AND REASONABLY INCIDENTAL FOR THE COMPLETE CONSTRUCTION OF THE <br />PROJECT SHALL NOT BE CONSTRUED AS RELEASING THE CONTRACTOR FROM HIS <br />RESPONSIBILITIES. <br />2. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, CLEARANCES AND <br />CONDITIONS TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. FAILURE TO DO SO <br />CONSTITUTES ACCEPTANCE AND RESPONSIBILITY FOR ALL EXISTING CONDITIONS. THE <br />CONTRACTOR WILL NOT BE ALLOWED ADJUSTMENTS IN THE TIME OR MONEY REQUIRED TO <br />RECTIFY THE SITUATION. <br />3. DO NOT SCALE DRAWINGS. GIVEN DIMENSIONS SHALL GOVERN. LARGE SCALE DRAWINGS <br />SHALL GOVERN OVER SMALL SCALE DRAWINGS. <br />4. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL PURCHASED, FABRICATED AND <br />FINISHED ITEMS FOR REVIEW BE THE ARCHITECT UNLESS WAIVED BY THE SAME. <br />5. ALL EQUIPMENT, MATERIALS AND ARTICLES INCORPORATED INTO THE PROJECT SHALL BE <br />NEW AND UNDAMAGED. ALL WORKMANSHIP SHALL BE WITHIN INDUSTRY STANDARDS. <br />6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR AND REPLACEMENT OF DAMAGE <br />TO AREAS CAUSED BY HIS WORK AT NO ADDITIONAL COST TO THE OWNER. <br />7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY CONDITIONS RELATING TO JOB <br />CONSTRUCTION INCLUDING A SAFE ENVIRONMENT FOR OCCUPANTS OF AREAS ADJACENT <br />TO THE WORK AREA. <br />8. THE CONTRACTOR SHALL PAY ALL FEES FOR PERMITS NECESSARY FOR PROPER <br />COMPLETION OF WORK, UNLESS NOTED OTHERWISE. <br />9. SHOULD THE CONTRACTOR OBSERVE ERRORS, DISCREPANCIES OR OMISSIONS IN THE <br />CONTRACT DOCUMENTS, HE SHALL PROMPTLY NOTIFY THE ARCHITECT REQUESTING <br />CLARIFICATION. THE CONTRACTOR SHALL NOT PROCEED WITH WORK AFFECTED BY SUCH <br />ERRORS, DISCREPANCIES OR OMISSIONS WITHOUT RECEIVING CLARIFICATIONS. <br />ADJUSTMENTS INVOLVING SUCH CONDITIONS MADE BY THE CONTRACTOR WITHOUT PRIOR <br />CLARIFICATION BY THE ARCHITECT, SHALL BE AT THE CONTRACTOR'S OWN RISK. <br />COMPLICATIONS ARISING FROM PROCEEDING WITHOUT CLARIFICATION SHALL BE <br />RESOLVED AT THE CONTRACTOR'S EXPENSE. <br />10. ALL WORK PERFORMED ON THIS PROJECT SHALL COMPLY WITH ALL APPLICABLE LOCAL, <br />STATE AND NATIONAL CODES, LAWS AND ORDINANCES. <br />11. ANYTHING IN THE CONTRACT DOCUMENTS NOT WITHSTANDING, THE CONTRACTOR <br />ACCEPTS THE RESPONSIBILITY OF CONSTRUCTING A WATERTIGHT, WEATHER TIGHT <br />PROJECT. <br />12. CONTRACTOR SHALL COORDINATE LOCATION OF ALL NEW ROOF MOUNTED EQUIPMENT <br />WITH OWNER PRIOR TO INSTALL. CENTER EQUIPMENT OVER BEAM OR COLUMN UNLESS <br />DIRECTED OTHERWISE BY OWNER. <br />13. CONTRACTOR SHALL PROVIDE 2x BLOCKING AT ALL WALL MOUNTED EQUIPMENT OR <br />ACCESSORIES. <br />14. ALL SIGNS, INCLUDING WINDOW SIGNS, TO BE SUBMITTED FOR REVIEW AND APPROVAL <br />UNDER SEPARATE PERMIT BY OWNER/CONTRACTOR. <br />15. ALL ANGLES AT 45° OR 90' UNLESS OTHERWISE NOTED. <br />DIVISION 2 DEMOLITION; HAZARDOUS MATERIALS <br />1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED TO ALLOW <br />FOR ALL PROPOSED NEW WORK. <br />2. PATCH, REPAIR, REPLACE AND FINISH ANY FLOOR, WALL OR CEILING TO MATCH ADJACENT <br />AREAS WHERE DEMOLITION HAS BEEN REQUIRED. <br />3. PROVIDE PROPER SHORING AND DISCONNECTION OF ALL UTILITIES PRIOR TO DEMOLITION. <br />4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE SITE FREE OF DEBRIS. <br />5. THE CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER PRIOR TO START OF WORK, <br />THE REQUIREMENTS FOR CORING OF FLOOR SLAB FOR ALL REQUIRED WORK. <br />6. THE ARCHITECT AND ENGINEERS, AND CONSULTANTS SHALL HAVE NO RESPONSIBILITY <br />FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF <br />PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT <br />NOT LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER <br />TOXIC SUBSTANCES. <br />8. COMPLY WITH APPLICABLE CODES AND/OR ORDIANCES CONCERNING DEMOLITION <br />OPERATIONS, REFUSE REMOVAL, AND DISPOSAL. <br />DIVISION 3 CONCRETE <br />1. CLEAN, GRIND AND FILL EXISTING CONCRETE TO ACCEPT VINYL TILE, CARPER, OR CERAMIC <br />TI LE. <br />2. FLOORS TO RECEIVE TILE OR SHEET VINYL SHALL NOT VARY MORE THAN 1 /4" PER 10 FT. <br />DIVISION 5 METALS <br />1. STEEL FRAMING: WITH EACH TYPE OF METAL FRAMING REQUIRED, PROVIDE <br />MANUFACTURER'S STANDARD STEEL RUNNER, BLOCKING, LINTELS, CLIP ANGLES, SHOES, <br />REINFORCEMENTS, FASTENERS AND ACCESSORIES AS RECOMMENDED BY THE <br />MANUFACTURER FOR THE APPLICATIONS INDICATED. <br />2. METAL STUDS: OPEN BOX SHAPED SECTIONS, 3-1/2 INCH x 25 GAGE MIN. (20 GAGE FOR <br />STUDS OVER 14'-0" IN HT. AND AT WALL AT WATER HEATER / MOP SINK ENCLOSURE). <br />DIVISION 7 THERMAL & MOISTURE PROTECTION <br />1. ALL INSULATING MATERIALS IN CONCEALED SPACES HAVE A FLAME SPREAD RATING OF <br />75 OR LESS AN A SMOKE DEVELOPED RATING OF 450 OR LESS PER ASTM E84. <br />DIVISION 8 DOORS & WINDOWS <br />1. ALL GLASS SUBJECT TO HUMAN IMPACT SHALL CONFORM TO THE STANDARD SET FORTH <br />IN THE LOCAL BUILDING CODE. <br />2. ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR <br />SPECIAL KNOWLEDGE. <br />3. MANUALLY OPERATED EDGE OR SURFACE -MOUNTED FLUSH BOLTS AND SURFACE BOLTS <br />OR ANY OTHER TYPE OF DEVICE THAT MAT BE USED TO CLOSE OR RESTRAIN THE DOOR <br />ARE PROHIBITED. WHERE EXIT DOORS ARE USED IN PAIRS AND APPROVED AUTOMATIC <br />FLUSH BOLTS ARE USED, THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS SHALL <br />HAVE NO DOORKNOB OR SURFACE -MOUNTED HARDWARE. THE UNLATCHING OF ANY LEAF <br />SHALL NOT REQUIRE MORE THAN ONE OPERATION. <br />4. PANIC HARDWARE, WHERE INSTALLED, SHALL COMPLY WITH THE LOCAL BUILDING CODE. <br />THE ACTIVATING MEMBER SHALL BE MOUNTED AT 36 TO 44 INCHES ABOVE THE FINISH <br />FLOOR. THE UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED IN THE <br />DIRECTION OF TRAVEL. <br />DIVISION 9 FINISHES <br />1.INTERIOR FINISHES TO HAVE A MAXIMUM FLAME SPREAD RATING OF 200 AND MAXIMUM <br />SMOKE DEVELOPMENT RATING OF 450. <br />2. STUD PARTITIONS TO BE ANCHORED SO AS TO RESIST A LATERAL LOAD OF 5 PSF AS <br />FOLLOWS, BOTTOM PLATE: ANCHOR TO SUB FLOOR WITH 300# POWER DRIVEN PINS AT <br />48" O.C. ICBO #1639 <br />3. GYP BOARD WALLS TO BE TAPED, SANDED AND HAVE SMOOTH FINISH, UNLESS NOTED <br />OTHERWISE. <br />4. THE CONTRACTOR SHALL PROVIDE AND INSTALL CAULKING WHERE NOT SPECIFICALLY <br />PERFORMED BY OTHER TRADES. <br />5. CERAMIC TILE FLOORS SHALL NOT VARY MORE THAN 1 /4" PER 10 FEET. <br />DIVISION 10 SPECIALTIES <br />1. SUITE NUMBER OR ADDRESS TO BE POSTED ABOVE DOOR. <br />2. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION / <br />MODIFICATION OF THE FIRE SPRINKLER SYSTEM. CONTRACTOR SHALL SUBMIT DRAWING <br />TO GOVERNING AUTHORITY FOR REVIEW AND APPROVAL PRIOR TO COMMENCING WITH <br />WORK. <br />DIVISION 15 MECHANICAL <br />1. VERIFY EXISTING MECHANICAL EQUIPMENT (HVAC) IS IN FULL WORKING ORDER, REPLACE <br />FILTERS THROUGHOUT SYSTEM. <br />2. VERIFY FRESH AIR SETTING, HUMIDITY CONTROLS, BALANCE, ETC. ARE ADEQUATE FOR <br />PROPOSED USE. REPLACE AND/OR MODIFY SYSTEM AS REQUIRED FOR COMPLIANCE WITH <br />LOCAL GOVERNMENTAL AGENCIES REQUIREMENTS. <br />ELECTRICAL LEGEND <br />SYMBOL <br />DESCRIPTION <br />COMMENTS <br />3 - TUBE <br />PRISMATIC (ACRYLIC) <br />FLUORESCENT LT. <br />LENSES FIXTURES <br />A.C.T. GRID MNT. <br />24" X 48" <br />PARABOLIC LENSES <br />3 - TUBE <br />FIXTURES <br />FLUORESCENT LT. <br />A.C.T. GRID MNT. <br />34 TUBE <br />PRISMATIC (ACRYLIC) <br />FLUORESCENT LT. <br />LENSES FIXTURES <br />A.C.T. GRID MNT. <br />24" X 24" <br />PARABOLIC LENSES <br />3 - TUBE <br />FIXTURES <br />FLUORESCENT LT. <br />A.C.T. GRID MNT. <br />DOUBLE TUBE <br />FLUORESCENT LT. <br />® <br />RECESSED CAN LT. <br />CLG MNT <br />SURFACE MOUNTED <br />INCANDESCENT <br />SURFACE MOUNTED <br />PULL -CHAIN <br />-(>PC <br />INCANDESCENT <br />SWITCH <br />C <br />CHANDELIER <br />CEILING MOUNTED <br />WALL MOUNTED <br />INCANDESCENT <br />0 0 o <br />TRACK LIGHTING <br />CEILING MOUNTED <br />INCANDESCENT <br />LIGHT & FAN <br />O O <br />EMERGENCY LIGHT <br />® <br />& EXIT LIGHT COMBO <br />0 <br />EMERGENCY LIGHT <br />® <br />EXIT LIGHT <br />® SPEAKERS <br />WALL OUTLET <br />18" ABOVE FIN. FLR. <br />42" A.F.F. WALL OUTLET <br />CLG <br />CEILING MOUNT DUPLEX <br />FOUR PLEX <br />WALL OUTLET <br />ez <br />EXISTING OUTLET <br />FIELD VARIFY <br />® <br />DIRECT CONNECTION <br />JUNCTION <br />DISCONNECT <br />ELECTRICAL PANEL <br />SINGLE POLE SWITCH <br />$2 <br />SINGLE POLE <br />TWO-WAY SWITCH <br />n <br />HVAC THERMO-STAT <br />42" A.F.F. <br />�J <br />WALL MOUNT <br />0 <br />TELEPHONE <br />DATA <br />os <br />OCCUPANCY SENSOR <br />DELAY. WALL MOUNT <br />SWITCH W/ TIME <br />42" A.F.F. <br />os <br />OCCUPANCY SENSOR <br />CEILING MOUNT <br />SWITCH W/ TIME <br />Tc <br />INTERMATIC TIME CLOCK <br />FTF DJ. TO PWR PNL <br />600UA <br />HVAC <br />LEGEND <br />A/C DIFFUSER <br />CLG. VENT <br />A/C RETURN AIR <br />pVR4 <br />CLG. GRILL <br />® <br />EXHAUSTFAN <br />CLG. VENT <br />HVAC <br />NOTE: <br />ALL EXISTING <br />HVAC SYSTEMS <br />TO REMAIN, AS IS, U.N.O. <br />ON DEMOLITIONS PLANS, AND <br />/ OR ALTERATION PLANS. <br />FIRE PROTECTION <br />�}E <br />SPRINKLER HEAD <br />O NEW OR RELOCATED <br />SPRINKLER HEAD <br />F.E. >0 <br />FIRE-EXTINGUISHER <br />❑ <br />FIRE -ALARM PULL STATION <br />AUDIO / STROBE <br />FIRE -ALARM COMBINATION <br />EXISTING MECHANICAL & ELECTRICAL: <br />EXISTING HVAC RTU TO REMAIN. <br />DIMENSIONS: <br />GENERAL CONTRACTOR TO FIELD VARIFY <br />LOCATION OF PROPOSED NEW WALLS <br />EQUIPMENT AND PLACEMENT, PRIOR <br />TO START OF WORK. DIMENSION DISCREPENCY <br />OR EQUIPMENT SHALL BE BROUGHT <br />TO ARCHITECT'S ATTENTION FOR CORRECTION. <br />SAMUEL <br />OLMEDO <br />ARCHITECT <br />FL. REG. AR0015027 <br />TEL. 407. 967. 3109 <br />soarcht @ yahoo.com <br />P.O. BOX 784825 <br />WINTER GARDEN, FL, 34778 <br />CONSULTANT <br />CONSULTANT <br />REVISIONS: <br />NO . DATE DESCRIPTION <br />INSTRUMENTS OF SERVICE OWNERSHIP <br />ALL REPORTS, PLANS, SPECIFICATIONS, <br />COMPUTER FILES, FIELD DATA, NOTES <br />INSTRUMENTS PREPARED BY THE <br />AND OTHER DOCUMENTS AND RELATED <br />INSTRUMENTS PREPARED BY THE <br />ARCHITECT OR CONSULTANTS AS <br />INTRUMENTS OF SERVICE SHALL REMAIN <br />THE PROPERTY OF THE ARCHITECT OR <br />CONSULTANT. THE ARCHITECT AND OR <br />THE CONSULTANT SHALL RETAIN ALL <br />COMMON LAW, STATUTORY AND OTHER <br />RESERVED RIGHTS, INCLUDING THE <br />COPYRIGHT THERETO. <br />MR. RANDY HAGAR <br />MR. JOSHUA LINCOLN <br />J�a <br />0 <br />M� 1 <br />. <br />Suss <br />ZEPHYR COMMONS <br />SHOPPING CENTER <br />7890 HWY 301 <br />ZEPHYRHILLS FLORIDA <br />EXISTING FLOOR PLAN <br />I <br />NUMBER <br />EL OLMEDO <br />AR0015027 <br />- - - - - - - <br />li TF_ I _T <br />