Laserfiche WebLink
CLADDING AND COMPONENTS PRESSURES, PSF <br />EXPOSURE C H<30' <br />1=1.0 V=110 0°<ROOF ANGLE<l0' <br />ROOF <br />WALL <br />OVERHANGS <br />TRIB. <br />AREA <br />ZONE <br />1 <br />ZONE <br />2 <br />ZONE <br />3 <br />ZONE <br />4 <br />ZONE <br />5 <br />ZONE <br />2 <br />ZONE <br />3 <br />A<20 <br />-30,5 <br />-51.1 <br />-77.0 <br />-33.0 <br />-40.7 <br />-44.0 <br />-72.2 <br />14.0 <br />14.0 <br />14.0 <br />30.5 <br />30.5 <br />20<A<50 <br />-29.7 <br />-45.6 <br />-63.7 <br />-31.6 <br />-38.1 <br />43.1 <br />-56.7 <br />14.0 <br />14.0 <br />14.0 <br />29.1 <br />29.1 <br />50<A<100 <br />-28.7 <br />-38.5 <br />-46.3 <br />-29.8 <br />-34.4 <br />_43.1 <br />-56.7 <br />14.0 <br />14.0 <br />14.0 <br />27.3 <br />27.3 <br />100<A <br />-27.9 <br />-39.3 <br />-39.3 <br />-28.6 <br />-31.6 <br />-41.3 <br />56.7 <br />14.0 <br />14.0 <br />14.0 <br />25.9 <br />25.9 <br />CLADDING AND COMPONENTS PRESSURES, PSF <br />EXPOSURE C H<35' <br />1=1.0 V=110 30°<ROOF ANGLE<45° <br />ROOF <br />WALL <br />OVERHANGS <br />TRIB. <br />AREA <br />ZONE <br />1 <br />ZONE <br />2 <br />ZONE <br />3 <br />ZONE <br />4 <br />ZONE <br />5 <br />ZONE <br />2 <br />ZONE <br />3 <br />A<20 <br />-44.2 <br />-51.8 <br />-51.8 <br />-47.9 <br />-59.0 <br />-75.0 <br />-75.0 <br />40.5 <br />40.5 <br />40.5 <br />44.2 <br />44.2 <br />20<A<50 <br />-42.1 <br />-49.3 <br />-49.3 <br />-45,8 <br />-55.2 <br />-72.6 <br />-72.6 <br />39.4 <br />39.4 <br />39.4 <br />42.2 <br />42.2 <br />50<A<100 <br />-39.0 <br />-46.5 <br />-46.5 <br />-43.2 <br />-49•9 <br />-72.6 <br />-72.6 <br />37.7 <br />37.7 <br />37.7 <br />39.6 <br />39.6 <br />100<A <br />-36.7 <br />-44.2 <br />-44.2 <br />-41.5 <br />-45.8 <br />-72.6 <br />72.6 <br />-36.7 <br />36.7 <br />36.7 <br />37.6 <br />37.6 <br />CLADDING AND COMPONENTS PRESSURES, PSF <br />EXPOSURE C H<45' <br />1=1.0 V=110 300<ROOF ANGLE<45° <br />ROOF <br />WALL <br />OVERHANGS <br />TRIB. <br />AREA <br />ZONE <br />1 <br />ZONE <br />2 <br />ZONE <br />3 <br />ZONE <br />4 <br />ZONE <br />5 <br />ZONE <br />2 <br />ZONE <br />3 <br />A<20 <br />-46.7 <br />-54.6 <br />-54.6 <br />-50.5 <br />-62.3 <br />-79.1 <br />-79.1 <br />40.5 <br />42.7 <br />42.7 <br />46.7 <br />46.7 <br />20<A<50 <br />-42.1 <br />-52.0 <br />-52.0 <br />-48.3 <br />-58.3 <br />-76.7 <br />-76.7 <br />39.4 <br />41.6 <br />41.6 <br />44.5 <br />44.5 <br />50<A<100 <br />-39.0 <br />-49.1 <br />-49.1 <br />-45.6 <br />-52.6 <br />_76.7 <br />-76.7 <br />37,7 <br />39.8 <br />39.8 <br />41.8 <br />41.8 <br />100<A <br />-36.7 <br />-46.7 <br />-46.7 <br />-43.8 <br />-48.3 <br />_76.7 T_ <br />-76.7 <br />36.7 <br />38.7 <br />38.7 <br />39.6 <br />39.6 <br />NET UPLIFT PRESSURES, PSF <br />EXPOSURE C H<30 <br />1=1 V=110 00<ROOF ANGI F<50 <br />ROOF <br />TRIB. <br />AREA <br />ZONE <br />1 <br />ZONE <br />2 <br />ZONE <br />3 <br />JOIST <br />-27.7 -43.6 <br />-61.7 <br />-36.3 <br />GIRDERS <br />-24.9 -36.3 <br />PR SR <br />SCALE: N.T.S. <br />4 <br />ZONES <br />SCALE: N.T.S. <br />GENERAL <br />A. ALL WORK SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 2004 WITH 2O05 AND 2006 <br />AMENDMENTS, AS ADOPTED AND SUPPLEMENTED BY LOCAL REGULATIONS. <br />B. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS AT <br />THE SITE AND SHALL NOTIFY THE ARCHITECT/ENGINEER OF DISCREPANCIES BETWEEN THE ACTUAL <br />CONDITIONS AND INFORMATION SHOWN ON THE DRAWINGS BEFORE PROCEEDING WITH WORK. <br />C. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE COMPLETE DESIGN <br />OF THE STRUCTURE. THEY DO NOT INDICATE THE MEANS AND METHODS OF CONSTRUCTION UNLESS <br />SO STATED OR NOTED. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT <br />THE WORKERS, OR OTHER PERSONS DURING CONSTRUCTION. <br />D. OBSERVATION VISITS TO THE SITE BY FOR OR REPRESENTATIVES OF THE FOR MAY BE MADE DURING <br />CONSTRUCTION. ANY SUPPORT SERVICES PERFORMED HEREIN SHALL BE DISTINGUSHED FROM <br />INSPECTION AND/OR TESTING SERVICES PERFORMED BY OTHERS, AND ARE NOT TO BE CONSTRUED <br />AS SUPERVISON AND/OR MANAGEMENT OF CONSTRUCTION. <br />E. THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACING AND SHORING OF ALL <br />STRUCTURAL MEMBERS AS REQUIRED FOR STABILITY OF THE STRUCTURE DURING ALL PHASES OF <br />CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER OF ANY <br />CONDITION WHICH, IN HIS OPINION, MIGHT ENDANGER THE STABILITY OF THE STRUCTURE OR CAUSE <br />DISTRESS WITHIN THE STRUCTURE. <br />F. CONSTRUCTION MATERIALS SHALL NOT BE STACKED ON FLOORS OR ROOFS IN EXCESS OF THE <br />DESIGN LIVE LOADS WHICH ARE INDICATED IN THE GENERAL NOTES. IT IS THE GENERAL <br />CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE SUBCONTRACTORS ARE INFORMED AND DO <br />NOT VIOLATE THIS IMPORTANT REQUIREMENT. IMPACT SHALL BE AVOIDED WHEN PLACING <br />MATERIALS ON FLOORS OR ROOFS. <br />G. DRAWINGS ARE NOT TO BE SCALED. <br />H. FOR ACTUAL ELEVATION OF FIRST FLOOR (REF. ELEV. 0'4" HEREIN), SEE SITE PLAN, <br />1. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE <br />NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO THE DETAILS PRESENTED, <br />SIMILAR DETAILS SHALL BE USED SUBJECT TO THE REVIEW OF ENGINEER OF RECORD. <br />J. <br />ALTERATIONS TO STRUCTURAL MEMBERS ARE NOT PERMITTED WITHOUT WRITTEN AUTHORIZATION <br />OF THE ENGINEER. ANY UNAUTHORIZED DEVIATION FROM THE CONTRACT DOCUMENTS, AND <br />CORRECTION THEREOF, IS THE RESPONSIBILITY OF THE CONTRACTOR. SUBSEQUENT <br />DOCUMENTATION / REQUESTS TO BUILDING ENGINEERING OF RECORD FROM GC SHALL INCLUDE <br />EVALUATION OF DEVIATIONS BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. <br />K. THE MOST STRINGENT REQUIREMENTS APPLY IN CASE OF CONFLICT BETWEEN SPECIFICATIONS, <br />STANDARDS, CODES AND DRAWINGS. <br />L. DESIGN DATA <br />ROOF LIVE LOADS <br />20 PSF <br />ROOF DEAD LOAD <br />20 PSF MAX. (10 PSF TO BE USED FOR UPLIFT) <br />WIND DESIGN: <br />VELOCITY: <br />110 MPH (ASCE 7-02) <br />IMPORTANCE: <br />1.00 <br />BLDG. CATEGORY: <br />II, ENCLOSED <br />WIND EXPOSURE: <br />C <br />INTERNAL PRESSURE COEFF: <br />+l- 0.18 <br />SUBMITTALS <br />A. SHOP DRAWING REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT. <br />CORRECTIONS OR COMMENTS MADE ON THIS REVIEW DO NOT RELIEVE THE CONTRACTOR OF <br />RESPONSIBILITY FOR ERRORS AND OMMISIONS, AND FROM COMPLIANCE WITH THE PLANS AND <br />SPECIFICATIONS. CORRECTIONS OR COMMENTS DO NOT AUTHORIZE AN INCREASE IN THE <br />CONSTRUCTION BUDGET. <br />B. APPROVAL OF SHOP DRAWINGS DOES NOT INDICATE ACCEPTANCE OF DEVIATIONS FROM CONTRACT <br />DOCUMENTS OR PREVIOUS SHOP DRAWING REVIEW, UNLESS SPECIFICALLY NOTED THEREIN BY <br />ENGINEER OF RECORD. <br />C. ANY CHANGES TO THE DESIGN CONCEPT SHOWN IN CONTRACT DOCUMENTS SHALL BE SUBMITTED IN <br />WRITING AND APPROVED BY THE ARCHITECT AND ENGINEER PRIOR TO SUBMITTING SHOP DRAWINGS. <br />ALL SUCH CHANGES SHALL BE "BUBBLED" ON THE SHOP DRAWINGS AND REFERENCED TO THE <br />PROPER R.F.I. <br />D. SUBMITTALS SHALL CONFORM TO THE REQUIREMENTS OF THE CONTRACT DRAWINGS (REFERENCE <br />ITEM C ABOVE FOR EXCEPTION). NON -CONFORMING OR NON -REVIEWED SUBMITTALS WILL BE <br />RETURNED WITHOUT REVIEW. <br />1. SHOP DRAWINGS SHALL BE "APPROVED", SIGNED AND DATED BY THE GENERAL CONTRACTOR <br />PRIOR TO SUBMITTAL TO ENGINEER AND ARCHITECT OF RECORD. <br />2. SHOP DRAWINGS SHALL NOT CONTAIN REPRODUCTIONS OF THE CONTRACT DRAWINGS. <br />3. SUBMITTAL REQUIREMENTS: <br />SHOP DRAWINGS / DATA TO BE SUBMITTED FOR APPROVAL 9 <br />CONSTRUCTION JOINT LOCATIONS IN STRUCTURAL SLABS 1 <br />WALL / VENEER CONTROL JOINT LOCATIONS <br />CONCRETE MIX DESIGNS (INDICATE INTENDED USE OF EACH) <br />REINFORCING STEEL <br />STRUCTURAL STEEL (INCLUDING JOIST & JOIST GIRDERS) <br />METAL DECK <br />SHOP DRAWINGS /DATA TO BE SUBMITTED FOR APPROVAL SUBMITTALS SHALL BE SIGNED AND <br />SEALED BY A REGISTERED PROFESSIONAL ENGINEER LISCENCED IN THE STATE OF THE PROJECT <br />LIGHT GAUGE FRAMING, TRUSSES AND TRUSS SYSTEMS <br />ALUMINUM STOREFRONT SYSTEMS <br />PRE-ENGINEERED CANOPIES, AWNINGS AND MARQUEES <br />E. PROVIDE COPIES OF MANUFACTURERS LITERATURE FOR ALL MATERIALS AND PRODUCTS USED IN <br />CONSTRUCTION ON THE PROJECT. <br />FOUNDATIONS / SITE WORK <br />A. FOUNDATION DESIGN IS BASED UPON THE FOLLOWING SOILS REPORT: <br />NO REPORT PROVIDED: <br />PRIOR TO CONSTRUCTION, CONTRACTOR SHALL RETAIN THE SERVICES <br />OF A QUALIFIED GEOTECHNICAL ENGINEER. THE GENERAL CONTRACTOR HEREIN <br />IS RESPONSIBLE FOR PERFORMING ALL EARTHWORK OPERATIONS IN STRICT <br />ACCORDANCE WITH GEOTECHNICAL ENGINEERING REQUIREMENTS. <br />IF THE FOUNDATION RECOMMENDATIONS AND/OR DESIGN VALUES DIFFER FROM THAT ASSUMED, <br />MODIFICATIONS TO THE DRAWINGS MAY BE REQUIRED. <br />DO NOT PLACE CONCRETE PRIOR TO GEOTECHNICAL APPROVAL, <br />B. ALLOWABLE SOIL PRESSURE ASSUMED TO BE 2000 PSF (REF A., ABOVE). SHALLOW FOUNDATION <br />SYSTEM IS ASSUMED TO BE ADEQUATE. ESTIMATED SETTLEMENT ASSUMED TO BE NO GREATER <br />THAN 1" OVERALL AND �' DIFFERENTIAL SETTLEMENT. IT IS ASSUMED THAT ALL PROBLEMATIC SOILS <br />(ORGANIC, EXPANSIVE, ETC.) WILL BE REMOVED AND REPLACED WITH SUITABLE STRUCTURAL FILL. <br />C. ANY FILL REQUIRED TO BACKFILL EXCAVATED AREA OR ACHIEVE FINISHED GRADE IN STRUCTURAL <br />AREAS SHALL BE AS INDICATED BY GEOTECHNICAL ENGINEER. THE FILL SHALL BE PLACED IN LEVEL <br />LIFTS NOT TO EXCEED 12 INCHES LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF THE <br />SOIL'S MODIFIED PROCTOR MAXIMUM DRY DENSITY AS DETERMINED BY ASTM SPECIFICATION D-1557. <br />D. IN -PLACE DENSITY TESTS SHALL BE PERFORMED BY AN EXPERIENCED ENGINEERING TECHNICIAN. <br />TESTS SHALL BE PERFORMED FOR EACH 2,000 SQUARE FEET, IN EVERY COLUMN FOOTING LOCATION <br />AND EACH 50 FEET ALONG WALL FOOTINGS. COPIES OF THE TEST REPORTS SHALL BE FURNISHED <br />TO THE STRUCTURAL ENGINEER. <br />E. REMOVE FREE WATER FROM EXCAVATIONS BEFORE PLACING CONCRETE, <br />F. CAUTION SHOULD BE USED WHEN OPERATING VIBRATORY COMPACTING EQUIPMENT NEAR THE <br />EXISTING STRUCTURE TO AVOID THE RISK OF DAMAGE TO THE STRUCTURE. <br />G. REFER TO ARCHITECTURE DRAWINGS FOR ANY NECESSARY WATERPROOFING REQUIREMENTS. <br />REINFORCED CONCRETE <br />A. CONCRETE WORK SHALL CONFORM TO ACI-05 SPECIFICATIONS, CODES AND STANDARDS. <br />B. CAST -IN -PLACE CONCRETE, UNLESS OTHERWISE NOTED (U.O.N.): <br />PORTLAND CEMENT PER ASTM C150 <br />PROPORTIONED FOR MAX. ALLOWABLE UNIT SHRINKAGE OF 0.03% <br />25% MAXIMUM FLYASH BY WEIGHT <br />SLABS <br />3000 PSI 28-DAY COMPRESSIVE STRENGTH, NORMAL WEIGHT, <br />MAXIMUM AGGREGATE SIZE OF 1 ", 0.55 MAX. W/C, 4"-5" SLUMP <br />FOOTINGS <br />3000 PSI 28-DAY COMPRESSIVE STRENGTH, NORMAL WEIGHT, <br />MAXIMUM AGGREGATE SIZE OF 1", 0.55 MAX. W/C, 3"4" SLUMP <br />COLUMNS/BEAMS <br />4000 PSI 28-DAY COMPRESSIVE STRENGTH, NORMAL WEIGHT, <br />MAXIMUM AGGREGATE SIZE OF 3/4", 0.45 MAX. W/C, 4%5" SLUMP <br />C. CONCRETE COVER OVER REINFORCEMENT: <br />FOOTINGS <br />3" <br />SLABS, COLUMNS AND BEAMS EXPOSED TO EARTH OR WHEATHER <br />2" (#6 TO #18 BARS), 1 1/2" (#3 TO #5 BARS) <br />SLABS NOT EXPOSED TO EARTH OR WHEATHER <br />3/4" (#3 TO #11 BARS) <br />BEAMS AND COLUMNS NOT EXPOSED TO EARTH OR WHEATHER <br />1 1/2" (#3 TO #18 BARS) <br />D. REINFORCING, UNLESS OTHERWISE NOTED (U.O.N.): <br />1. REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60. <br />2. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. WIRE FABRIC SHALL BE CONTINUOUS, <br />LAPPED ONE CROSS WIRE SPACING PLUS 2" MINIMUM. <br />3. WHERE CONTINUOUS REINFORCING IS SPECIFIED, SUCH REINFORCING MAY BE SPLICED <br />WHERE APPROVED IN WRITTING BY THE ENGINEER OF RECORD. <br />4. AT CHANGES IN DIRECTION OF CONCRETE WALLS, BEAMS, AND FOOTINGS, PROVIDE CORNER <br />BARS OF SAME SIZE, QUANTITY AND SPACING AS HORIZONTAL STEEL. <br />5. LAP SPLICES SHALL BE 48 BAR DIAMETERS, WIRED TOGETHER. <br />E. CONTRACTOR SHALL EMPLOY A QUALIFIED TESTING LABORATORY TO PREPARE ONE SET OF FOUR <br />TEST CYLINDERS PER DAY OR ONE SET FOR EACH 50 CUBIC YARDS POURED, MAXIMUM. <br />LABORATORY REPORT SHALL BE FURNISHED TO THE STRUCTURAL ENGINEER SHOWING STRENGTH <br />OF CONCRETE AT 7 (1 CYLINDER) AND 28 (2 CYLINDERS) DAYS, FINAL CYLINDER SHALL BE HELD IN <br />RESERVE. <br />F. THERE SHALL BE NO HORIZONTAL JOINTS IN ANY CONCRETE POURS UNLESS SHOWN ON THE <br />STRUCTURAL DRAWINGS. THE ENGINEER OF RECORD SHALL APPROVE ALL DEVIATIONS OR <br />ADDITIONAL JOINTS IN WRITING. <br />G. SAW CUT CONTROL JOINTS SHALL BE LOCATED @ 15' O.C. MAXIMUM, U.O.N. WITH LENGTH TO WIDTH <br />RATIO NOT TO EXCEED 2:1. REFER TO SUBMITTAL REQUIREMENTS REGARDING COORDINATION OF <br />CONSTRUCTION JOINTS. REFER TO PLANS FOR EXPANSION JOINT LOCATIONS. <br />H. ALL EPDXY ANCHORS USED AT REINFORCED CONCRETE SHALL BE HILTI HVA, U.O.N, <br />I. POWDER ACTUATED FASTENERS (PAFS) NOT PERMITTED AT CONCRETE. <br />STRUCTURAL STEEL <br />A. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO AISC SPECIFICATIONS FOR STRUCTURAL STEEL <br />BUILDINGS - ALLOWABLE STRESS DESIGN,13TH ED. <br />B. MATERIAL SHALL CONFORM TO THE FOLLOWING, EXCEPT AS NOTED: <br />W BEAMS ASTM A992 <br />STRUCTURAL STEEL PLATES AND SHAPES ASTM A36 <br />THREADED ROD ANCHO:7' )LTS ASTM F1554 GRADE 36 <br />OTHER ANCHOR BOLTS ASTM A307 <br />PIPE SECTIONS ASTM A53, GRADE B. <br />TUBE SECTIONS ASTM A500, GRADE B. <br />C. WELDING, UNLESS OTHERWISE NOTED (U.O.N.): <br />1. ALL SHOP AND FIELD WELDING SHALL CONFORM TO AWS STRUCTURAL WELDING CODE, <br />ANSI/AWS D1.1. <br />2. ALL WELDING IN THE SHOP AND IN THE FIELD SHALL BE PERFORMED BY CERTIFIED <br />WELDERS ONLY. <br />3. WELDING ELECTRODES SHALL BE E70XX LOW HYDROGEN. <br />D. CONNECTIONS, UNLESS OTHERWISE NOTED (U.O.N.): <br />1. TIGHTEN BOLTS BY THE "SNUG -TIGHT" METHOD. <br />2. FIELD CONNECTIONS SHALL BE MADE WITH 3/4" DIA. MIN. HIGH -STRENGTH BEARING TYPE BOLTS <br />(A325N) WITH THREADS ASSUMED TO BE INCLUDED IN SHEAR PLANES. <br />3. CONNECTIONS NOT FULLY DETAILED IN PLANS SHALL BE DESIGNED BY CONTRACTOR ACCORDING <br />TO AISC STANDARDS. IF FORCES ARE NOT PRESENTED IN PLAN OR DIRECTLY IMPLIED THEREIN, <br />CONNECTIONS SHALL BE BASED ON THE FULL CAPACITY OF THE SECTION(S) - EXCEPT THAT STEEL <br />CONNECTIONS FOR BEAMS SIMPLY SUPPORTED AND UNIFORMLY LOADED MAY BE BASED ON 55% <br />OF THE AISC UNIFORM 'LOAD CARRYING CAPACITY OF THE BEAMS. <br />4. CONNECTIONS SHALL BE DOUBLE ANGLE OR STANDARD SHEAR TAB TYPE U.O.N.. SINGLE ANGLE <br />AND EXTENDED SHEAR TAB CONNECTIONS SHALL NOT BE PERMITTED UNLESS SPECIFICALLY i <br />DETAILED AS SUCH HEREIN. <br />t. 6H UF UKAVVIINUb (5tt bUISMi I f F''_",.=>) bHALL INL;L.UUt UUMh Lt It Ut I AILINU Ul- b I KUC; f UKAL 6 I ttL <br />MEMBERS AND CONNECTIONS AS REQUIRED TO FABRICATE AND ERECT ALL STRUCTURAL STEEL <br />FRAMING. <br />F, GROUT UNDER BEARING PLATES SHALL BE NON-METALLIC, NON -SHRINK TYPE WITH A COMPRESSIVE <br />STRENGTH OF AT LEAST 6000 PSI WHEN BEARING ON 3000 PSI CONCRETE, AND 8000 PSI WHEN <br />BEARING ON 4000 PSI CONCRETE. <br />G. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT -DIP GALVANIZED OR OTHERWISE PROTECTED. <br />H. ALL STEEL EXPOSED TO SOIL SHALL BE ENCASED IN CONCRETE OR OTHERWISE PROTECTED, <br />COLD -FORMED STEEL FRAMING / TRUSS SYSTEMS <br />A. ALL COLD -FORMED STEEL FRAMING SHALL CONFORM TO THE "NORTH AMERICAN SPECIFICATIONS <br />FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS," AISI, 2001 EDITON AND 2004 <br />SUPPLEMENT. <br />B. ALL LOAD BEARING STUDS SHALL BE "C" SHAPE EQUAL TO A MINIMUM OF 43 MIL THICK, U.O.N. <br />C. MATERIALS, U.O.N.: <br />54 MIL AND HEAVIER STUDS 50 KSI MIN. <br />33, AND 43 MIL STUDS 33 KSI MIN. <br />RUNNERS AND ACCESSORIES 33 KSI MIN. <br />D. PROVIDE MANUFACTURERS STANDARD STEEL RUNNERS, BRIDGING, BLOCKING, BRACING, CLIPS, <br />REINFORCEMENTS, ETC. - TEMPORARY AND PERMANENT - AS REQUIRED TO PROVIDE A COMPLETE <br />FRAMING SYSTEM CAPABLE OF ACCOMMODATING THE LOADS PRESENTED IN THE CONSTRUCTION <br />DOCUMENTS. ALL FIELD INSTALLED ITEMS SHALL BE PRESENT ON INSTALLATION DRAWINGS. <br />E. ALL PARTS AND ACCESSORIES SHALL BE FORMED FROM STEEL HAVING A G-60 GALVANIZED COATING <br />MEETING THE REQUIREMENTS OF ASTM A525 /ASTM A653. <br />F. FRAME BOTH SIDES OF EXPANSION JOINTS, ALLOWING FOR ADEQUATE MOVEMENT AS REQUIRED. <br />G. FIELD SPLICES IN MATERIALS SHALL NOT BE PERMITTED EXCEPT WHERE INDICATED IN SHOP AND/OR <br />INSTALLATION DRAWINGS AND APPROVED BY STRUCTURAL ENGINEER. <br />H. U.O.N., ANCHORAGE OF LIGHT GAUGE FRAMING SHALL BE BY THE SPECIALITY ENGINEER. ALL <br />ANCHORAGES TO BUILDING STRUCTURE SHALL BE ENGINEERED PARTS/ASSEMBLIES, OR <br />ENGINEERED PRODUCTS FOR USE WITH LIGHT GAUGE METAL (OR READILY ADAPTABLE TO LIGHT <br />GAUGE METAL). ENGINEER OF RECORD SHALL REVIEW AND APPROVE ALL ANCHORAGES. <br />INSTALLATION DRAWINGS SHALL INDICATE ALL ANCHORAGES REQUIRED. <br />I. DEFLECTION LIMITS, U.O.N. IN SPECIFICATIONS OR PLANS: <br />U360, U.O.N. <br />U480, BRICK AND MASONRY VENEER <br />.11 <br />LIGHT GAUGE FRAMING "SYSTEMS", INCLUDING TRUSS SYSTEMS SHALL INCLUDE ALL NECESSARY <br />PARTS AND ACCESSORIES REQUIRED TO FORM A COMPLETE "SYSTEM," INCLUDING, BUT NOT <br />LIMITED TO BRIDGING, BRACING, CLIPS, SHEAR BLOCKING, WEB STIFFENERS, AND HARDWARE - <br />TEMPORARY AND PERMANENT. FAILURE TO COMPLY WITH THIS REQUIREMENT WILL RESULT IN <br />REJECTION OF SUBMITTALS WITHOUT FURTHER REVIEW. <br />K. REFERENCE SUBMITTAL SECTION THIS SHEET. <br />STRUCTURAL INSPECTION <br />A. THE CONTRACTOR OR OWNER SHALL EMPLOY A QUALIFIED INDEPENDENT INSPECTION AGENCY. THIS <br />AGENCY (REFERRED TO AS INSPECTOR HEREIN) SHALL BE RESPONSIBLE FOR VERIFYING THAT <br />PROJECT STRUCTURAL WORK IS ACCOMPLISHED IN CONFORMANCE WITH THE CONTRACT <br />DOCUMENTS. <br />B. DURATION AND FREQUENCY OF JOB VISITS SHALL BE SUFFICIENT FOR THE INSPECTOR TO STATE AT <br />THE COMPLETION OF THE PROJECT THAT THE STRUCTURAL WORK IS ACCOMPLISHED, AND ITS <br />RELATED ELEMENTS HAVE BEEN ERECTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. <br />SPECIFIC SYSTEMS TO BE INSPECTED INCLUDE: <br />FOUNDATION <br />CONCRETE (COLUMNS /BEAMS) <br />CONCRETE (GENERAL, SLAB ON GRADE) <br />MASONRY <br />STRUCTURAL STEEL (INCLUDING BAR JOISTS AND JOIST GIRDERS) <br />METAL DECK (FLOOR AND ROOF) <br />LIGHT GAUGE FRAMING (INCLUDING TRUSSES AND TRUSS SYSTEMS) <br />C. THE FOREGOING LIST IS NOT INTENDED TO BE ALL INCLUSIVE. THE INSPECTOR SHALL USE HIS <br />PROFESSIONAL JUDGMENT AND HIS KNOWLEDGE OF THE JOB SITE CONDITIONS AND THE <br />CONTRACTORS' PERFORMANCE TO DECIDE WHICH ADDITIONAL STRUCTURAL SYSTEM OR ITEMS MAY <br />REQUIRE ATTENTION. <br />D. THE INSPECTOR DOES NOT RELIEVE THE CONTRACTOR'S CONTRACTUAL OR STATUTORY <br />OBLIGATIONS. THE CONTRACTOR HAS THE SOLE RESPONSIBILITY FOR ANY DEVIATIONS FROM THE <br />OFFICIAL CONTRACT DOCUMENTS. THE INSPECTOR WILL NOT REPLACE THE QUALITY CONTROL <br />PERSONNEL OF THE CONTRACTOR. <br />E. ALL INSPECTION REPORTS SHALL BE FORWARD BY THE INSPECTOR TO THE ENGINEER AND <br />ARCHITECT OF RECORD. <br />STRUCTURAL PLYWOOD / CDX. 5/8" <br />MIN. THICKNESS <br />-ZONES 1, 2, AND 4 (REF. S001) #10 <br />BUGLEHEAD SCREWS @ 4" O.C. <br />EDGES AND 6" FIELD <br />-ZONES 3, AND 5 (REF. S001) #10 <br />BUGLEHEAD SCREWS @ 4" O.C. <br />EDGES AND 4" FIELD <br />DENSGLASS <br />-ZONE 4 (REF. S001) #10 MIN. <br />WAFERHEAD SCREWS @ 4" O.C. <br />EDGES AND 6" FIELD <br />-ZONE 5 (REF. S001) #10 MIN. <br />WAFERHEAD SCREWS @ 4" O.C, <br />EDGES AND 4" FIELD <br />LIST OF STRUCTURAL ABBREVIATIONS <br />AB <br />ANCHOR BOLTS <br />T & B <br />TOP AND BOTTOM <br />ADDL <br />ADDITIONAL <br />T & G <br />TONGUE AND <br />ALT <br />ALTERNATE <br />GROOVE <br />ANCH <br />ANCHOR <br />THK <br />THICK <br />APPROX <br />APPROXIMATE <br />THIRD <br />THREAD/THREADED <br />ARCH <br />ARCHITECTURE/ARCHITECTURAL <br />TB <br />TIE BEAM <br />BB <br />BOND BEAM <br />TOC <br />TOP OF CONCRETE <br />BLDG <br />BUILDING <br />TOM <br />TOP OF MASONRY <br />BM <br />BEAM <br />TOS <br />TOP OF STEEL <br />BO <br />BOTTOM OF (SEE TO) <br />TYP <br />TYPICAL <br />BOT / BTM <br />BOTTOM <br />TS <br />TUBE STEEL <br />BP <br />BASE PLATE/BEARING PLATE <br />LINO <br />UNLESS NOTED <br />BRG <br />BEARING <br />OTHERWISE <br />BTW <br />BETWEEN <br />LON <br />UNLESS OTHERWISE <br />CANT <br />CANTILEVER <br />NOTED <br />CB <br />CONCRETE BEAM <br />VERT <br />VERTICAL <br />CC <br />CONCRETE COLUMN <br />VIF <br />VERIFY IN FIELD <br />CIP <br />CAST IN PLACE <br />W <br />WIDE FLANGE <br />CJ <br />CONSTRUCTION JOINT <br />WB <br />WALL BEAM (TILT) <br />CL <br />CENTERLINE <br />WC <br />WALL COLUMN (TILT) <br />CLR <br />CLEAR/CLEARANCE <br />W/ <br />WITH <br />COL <br />COLUMN <br />W/o <br />WITHOUT <br />CONC <br />CONCRETE <br />WD <br />WOOD <br />CONNX <br />CONNECTION <br />WGT <br />WEIGHT <br />CONST <br />CONSTRUCTION <br />WH <br />WEEP HOLE <br />CONT <br />CONTINUOUS <br />WP <br />WORKING POINT <br />CORR <br />CORRUGATED <br />WT <br />STEEL TEE SECTION <br />CMU <br />CONCRETE MASONRY UNIT <br />WWF <br />WELDED WIRE <br />DIET <br />DETAIL <br />FABRIC <br />DIA/DIAM <br />DIAMETER <br />@ <br />AT <br />DIM <br />DIMENSION <br />& <br />AND <br />DIST <br />DISTANCE <br />DIN <br />DOWN <br />DR <br />DRAIN <br />DWG <br />DRAWING <br />DWL <br />DOWEL <br />EA <br />EACH <br />EE <br />EACH <br />END <br />EF <br />EACH <br />FACE <br />EJ <br />EXPANSION JOINT <br />EL, <br />ELEV ELEVATION <br />ELECT <br />ELECTRICAL <br />EMB <br />EMBEDMENT <br />ENGR <br />ENGINEER <br />EQ <br />EQUAL <br />EQUIP <br />EQUIPMENT <br />EQUIV <br />EQUIVALENT <br />ES <br />EACH SIDE <br />EXIST <br />EXISTING <br />EXP <br />EXPANSION <br />EXT <br />EXTERIOR <br />EW <br />EACH WAY <br />FAB <br />FABRICATE <br />FD <br />FLOOR DRAIN <br />FDN <br />FOUNDATION <br />FF <br />FINISHED FLOOR <br />FIN <br />FINISH(ED) <br />FLOOR. <br />FTG <br />FOOTING <br />GA <br />GAGE/GAUGE <br />GALV, GV <br />GALVANIZED <br />GC <br />GENERAL CONTRACTOR <br />HAS <br />HEADED ANCHOR STUD <br />HB <br />HIGH BEAM (MASONRY) <br />HORIZ <br />HORIZONTAL <br />HSB <br />HIGH STRENGTH BOLTS <br />HSS <br />HOLLOW STEEL SECTION <br />HT <br />HEIGHT <br />INT <br />INTERIOR <br />JST <br />JOIST <br />JT <br />JOINT <br />K <br />KIPS <br />KO <br />KNOCK OUT <br />KSF <br />KIPS PER SQUARE FOOT <br />KSI <br />KIPS PER SQUARE INCH <br />L <br />ANGLE <br />LB <br />LOW BEAM (MASONRY) <br />LBS <br />POUNDS <br />LID <br />DEVELOPMENT LENGTH <br />LDH <br />LONG DIMENSION HORIZONTAL <br />LDV <br />LONG DIMENSION VERTICAL <br />LGTH <br />LENGTH <br />LLBB <br />LONG LEG BACK TO BACK <br />LLH <br />LONG LEG HORIZONTAL <br />LLV <br />LONG LEG VERTICAL <br />MAIL <br />MATERIAL <br />MAX <br />MAXIMUM <br />MB <br />MASONRY BEAM <br />MC <br />MOMENTCONNECTION <br />MC <br />MASONRY COLUMN <br />MCJ <br />MASONRY CONTROL JOINT <br />MECH <br />MECHANICAL <br />MEZZ <br />MEZZANINE <br />MFR <br />MANUFACTURE/MANUFACTURERS <br />MIN <br />MINIMUM <br />MISC <br />MISCELLANEOUS <br />MTL <br />METAL <br />NIC <br />NOT IN CONTRACT <br />NOM <br />NOMINAL <br />NTS <br />NOT TO SCALE <br />oC <br />ON CENTER <br />OPNG <br />OPENING <br />OPP <br />OPPOSITE <br />PB <br />PARAPET BEAM (MASONRY) <br />PCC <br />PRECAST CONCRETE <br />PL <br />PLATE <br />PLF <br />POUNDS PER LINEAR Fool <br />PLY <br />PLYWOOD <br />PREENG <br />PRE-ENGINEERED <br />PREFAB <br />PREFABRICATED <br />PRELIM <br />PRELIMINARY <br />PROJ <br />PROJECTION <br />PSF <br />POUNDS PER SQUARE FOOT <br />PSI <br />POUNDS PER SQUARE INCH <br />PT <br />PRESSURE TREATED <br />PT <br />POST TENSIONING) (ED) <br />PW <br />PANEL WIDTH <br />RAD <br />RADIUS <br />RB <br />ROOF BEAM (MASONRY) <br />RCP <br />REINFORCED CONCRETE PIPE <br />RD <br />ROOF DRAIN <br />REF <br />REFERENCE <br />REINF <br />REINFORCING <br />REQ'D <br />REQUIRED <br />REV <br />REVISION <br />RTU <br />ROOF TOP UNIT <br />RW <br />RETAINING WALL <br />SECT <br />SECTION <br />SCHED,SCH <br />SCHEDULE <br />SIM <br />SIMILAR <br />SP,SPC <br />SPACE/SPACES <br />SPECS <br />SPECIFICATIONS <br />SQ <br />SQUARE <br />SS <br />STAINLESS STEEL <br />STD <br />STANDARD <br />STL,ST <br />STEEL <br />STRUCT <br />STRUCTURAL <br />SYM <br />SYMMETRICAL <br />00 <br />N _ <br />Mo <br />a <br />w rn <br />-d G <br />O� <br />�w <br />a , <br />¢o0 <br />o� I <br />�n vo 3 <br />O1 a 3 <br />cn <br />0 <br />0 <br />co <br />CIO LL <br />c) C) <br />Lu <br />z <br />od!EU `> <br />5,o ' <br />CD CL U) <br />w <br />0 <br />Y cu <br />N IZ <br />ry <br />m <br />