NOTE: <br />G.C. SHALL BE RESPONSIBLE FOR COORDINATION <br />OF ALL ACCESSORIES. ALL ACCESSORIES SHALL BE <br />PROVIDED AS A PACKAGE TO STAPLES. <br />NAME PLATE-� <br />- --AIRFLOW <br />CONFIRMATION <br />_ <br />STAPLES <br />SWITCH <br />ELECTRONIC <br />I RTU-1 <br />THERMOSTAT <br />EfM <br />DIRTY FILTER <br />MODULE <br />SWITCH <br />DUCT TEMP <br />-RETURN Alft INSULATED FLEXIBLE DUCT, <br />SENSOR <br />co L <br />SENSOR INSIDE DIAMETER AS NOTED <br />ON PLANS - FLEX DUCT IS <br />DTS <br />RAS <br />INTENDED TO FACILITATE PRECISE <br />ROOF UNE� <br />i�� <br />STANDARD LOCATION. (6'-0" MAX.) <br />ROOF CURB <br />ROOM TEMP CO2 SENSOR <br />SENSOR IN RETRUN AIR DUCT <br />COMMUNICATION CABLES <br />WIRING BY STAPLES (SEE <br />EMS NOTES DRAWING M-1) <br />1. ETM, DUCT SENSORS, AIRFLOW SWITCH AND DIRTY FILTER SWITCH ARE FACTORY INSTALLED. <br />2. THE DTS, (DUCT TEMP SENSOR) IS LOCATED IN THE RETURN AIR DUCT WITHIN THE <br />ROOF TOP UNITS. <br />3. LANDLORD FURNISHED UNITS ARE TO BE PROVIDED WITH FACTORY PRE -WIRED <br />ENERGY MANAGEMENT SYSTEM (EMS) CONNECTIONS. <br />4. REFERENCE EMS RISER NOTES ON ELECTRICAL DRAWINGS. <br />5. NUMBER RTU'S AS INDICATED ON STAPLES EMS SYSTEM. <br />6. ROOM TEMPERATURE SENSOR TO BE FURNISHED BY LENNOX AND INSTALLED BY STAPLES. <br />7. CO2 SENSOR TO BE FURNISHED BY LENNOX, INSTALLED BY HVAC CONTRACTOR & <br />WIRED BY ELECTRICAL CONTRACTOR. <br />DETAIL <br />-OOFTOP EMS <br />NO SCALE <br />Wlhl(_ All IT <br />nnm <br />4 DETAIL -VOLUME DAMPER <br />M-2 NO SCALE <br />s fib' <br />�4 <br />3% x 21Y2 <br />RETURN AIR <br />DUCT OPENING <br />RETURN AIR SUPPLY AIR 21' <br />OPENING OPENING <br />RTU-1, 2, 3, 4 AND 6 <br />Z4xZU UUGI <br />OPENING <br />(TYPICAL 2) <br />30A x 2174 <br />SUPPLY AIR <br />DUCT OPENING <br />DETAIL -DUCT RTU CURBS <br />M-2 NO SCALE <br />INSULATE TOP OF <br />DIFFUSER <br />CEILING DIFFUSER <br />INSULATION <br />SUPPLY DUCT - <br />FLARED SPIN -IN FITTING WITH <br />MANUAL DAMPER <br />SECURE FLEXIBLE DUCT TO <br />DIFFUSER NECK AND SPIN -IN <br />FITTING WITH STAINLESS STEEL <br />SCREW CLAMP <br />1__1IBC+1 141 C i' 7E �1�� � � �1►I f'E01l•1 <br />NO SCALE <br />V.D. <br />L = 1/4W, 4" MIN. <br />NOTE: <br />NOTE: <br />IN GENERAL, ELBOWS TO HAVE FULL <br />AIRFOIL BLADES TO BE USED WHERE <br />TURNING RADIUS (R=A). WHERE "R" <br />NORMAL RADIUS ELBOW IS IMPRACTICAL <br />IS LESS THAN A" BUT NOT LESS THAN <br />& WHERE ELBOW IS WITHIN 5 FT OF A <br />1/3"A", USE ONE VANE SPACED AS <br />BRANCH TAKE -OFF OR BOOSTER HEATER <br />SHOWN. WHERE "R" IS LESS THAN <br />(TO ASSURE STRAIGHT FLOW). <br />1/3"A", USE TWO VANES SPACED AS <br />SHOWN. MINIMUM RADIUS (R) = 4 INCHES. <br />3 DETAIL -TURNING VANES <br />M-2 NO SCALE <br />iff <br />SUPPLY COORDINATE <br />DIMENSIONS WITH <br />SHEET M-1 <br />I <br />1 <br />14'-6" AFF <br />28X20 RETURN DUCT PROVIDE 48"x24 <br />RETURN GRILL 1'-0" (MIN.) ABOVE <br />o SUPPLY GRILLS. TITUS MODEL. 350ZRL <br />(TYP. RTU-1, 2, 3, & 4). <br />RECTANGULAR BRANCH ENTRY <br />5 DETAIL -DUCT TAKE -OFFS <br />M-2 NO SCALE <br />NOTE: <br />TOP OF RTU CURBS SHALL BE LEVEL <br />SHIM AS REQUIRED. <br />PROVIDE PLUG FOR PROVIDE CLEANOUT AT EACH <br />MAINTENANCE -----,,,CHANGE OF DIRECTION OR EVERY 30' <br />DRAIN LINE. SLOPE <br />;�: <br />TAA� <br />WITH FLOW 1/8"/FT <br />TO LOCATION SHOWN <br />ON DRAWINGS <br />A = FAN SUCTION PRESSURE + 1 INCH <br />CONDENSATE CONDENSATE PIPE <br />PIPE SIZE SIZE BELOW SLAB <br />MAX. TONS ABOVE SLAB OR BELOW GRADE <br />2 3/4" 1-1/4" <br />5 1'I 1-1/2" <br />30 1 1/4" 2" <br />7 CONDENSATE DRAIN TRAP DETAIL <br />M-2 NO SCALE <br />RTU-5 <br />13'- 6" AFF <br />I <br />28"X20" SUPPLY DUCT PROVIDE 24"X18" <br />GRILL ON TWO FACES AND 16"X16" ON <br />OTHER TWO FACES TO CREATE A 4-WAY <br />DISTRIBUTION. TITUS MODEL 30ORL. <br />(TYP. RTU-1, 2, 3, & 4). <br />DETAIL- SUPPLY + RETURN GRILLS <br />NO SCALE <br />RTU <br />X <br />Q 148" MAX. HEIGHT <br />ABV. FRAM E] <br />0 <br />101 <br />'. \r \ <br />RTU TIE -DOWN DETAIL <br />NO SCALE <br />#12 TEK SCREW <br />(TYP.) <br />ROOF MEMBRANE CEMENT <br />NOTE: <br />PRE-ENGINEERED <br />CURB BY RTU <br />SUPPLIER <br />NAILER SUPPLIED W/ CURB, ATTACH TO <br />CURB AS PER MANUFACTURER'S <br />RECOMMENDATIONS / SPECS. <br />RAIL <br />SECURE CURB TO STEEL FRAME USING <br />#12 TEK SCREWS, 2 @ EA. CORNER & <br />12" O.C. BTW. <br />STL. DECK <br />Lp <br />MICRO -HOLD <br />(8 MIN.) <br />(2 EA. SIDE) <br />MICROMETL, 16 GA. MICRO -HOLD HOLD <br />DOWN. ATTACH TO UNIT RAIL REF: MANUF. <br />FOR INSTALLATION REQUIREMENTS <br />PLUMBER STRAP <br />SCHEDULE 40 PVC CONDENSATE PIPING <br />MICRO PIPE SUPPORT <br />4'-0" 0. C. <br />ROOF SYSTEM <br />CONDENSATE PIPE SUPPORT ON ROOF <br />NO SCALE <br />PACKAGE ROOFTOP A.C. UNIT <br />SCHEDULE 1,110 <br />DESCRIPTION <br />RTU-1 <br />RTU-2 <br />RTU-3 <br />RTU-4 <br />RTU-5 <br />RTU-6 <br />REMARKS <br />SERVICE <br />SALES <br />SALES <br />SALES <br />SALES <br />FRONT OFFICE <br />OFFICES/RECEIVING <br />-- <br />LENNOX MODEL NO. <br />!- <br />LCA120H4B <br />L_CA'120H4-B <br />LCA120H4B <br />L_CA120H4B <br />LCAO36H4B <br />-REAR <br />LCA120H4B <br />NOMINAL TONS <br />10 <br />10 <br />10 <br />10 <br />3 <br />10 <br />SUPPLY AIR (CFM) <br />4,000 <br />4,000 <br />4,000 <br />4,000 <br />1200 <br />4,000 <br />OUTSIDE AIR (CFM) <br />1,110 <br />1,110 <br />1,110 <br />1,110 <br />200 <br />940 <br />DRIVE TRAIN <br />BELT <br />BELT <br />BELT <br />BELT <br />BELT <br />BELT <br />HEATING (KW) <br />22.5 <br />22.5 <br />22.5 <br />22.5 <br />7 <br />22.5 <br />EXTERNAL S.P. <br />.80 <br />.80 <br />.80 <br />.80 <br />.50 <br />.80 <br />SUPPLY FAN HP <br />A <br />3 <br />3 <br />3 <br />3 <br />3/4 <br />- <br />3 <br />EER <br />11.2 <br />11.2 <br />11.2 <br />11.2 <br />13.4 SEER <br />11.2 <br />MOCP <br />45 <br />45 <br />45 <br />45 <br />20 <br />45 <br />MCA. <br />42 <br />42 <br />42 <br />42 <br />16 <br />42 <br />VOLTAGE/PHASE <br />460V/30 <br />46OV/30 <br />460V/30 <br />460V/30 <br />460/30 <br />460'V/30 <br />WEIGHT (LBS.) <br />1360 <br />1360 <br />1360 <br />1360 <br />775 <br />1360 <br />NOTES: <br />ACCESSORIES FACTORY INSTALLED: <br />A. NOVAR 2051 EMS MODULE <br />1. EXTERNAL STATIC <br />PRESSURE CONSISTS OF DUCTWORK, DAMPER, AND AIR DEVICES. <br />IT DOES NOT INCLUDE COILS, FILTERS, MIXING <br />B. ECONOMIZER GLOBAL CONTROL <br />PLENUMS, ETC. <br />C. BAROMETRIC EXHAUST <br />2. ALL COOLING CAPACITIES <br />ARE NET. FAN MOTOR HEAT MUST BE ADDED TO OBTAIN <br />TOTAL COIL LOAD. <br />3. LANDLORD SHALL <br />ENSURE THAT ALL ITEMS LISTED UNDER "ACCESSORIES TO BE PROVIDED <br />BY MFG. ARE COORDINATED. IF MFG. <br />D. 11OV GFI OUTLET <br />DOES NOT HAVE <br />ANY ITEM AVAILABLE, LANDLORD SHALL PROVIDE, COORDINATE, AND INSTALL SEPARATELY, REGARDLESS, ALL ITEMS <br />SHALL BE PROVIDED TO STAPLES, NO EXCEPTIONS. <br />ACCESSORIES FIELD INSTALLED: <br />4. ALL COOLING VALUES ARE TO BE BASED ON SITE ELEVATIONS. <br />5. PROVIDE VERTICAL FLOW TYPE SUPPLY AND RETURN. <br />A. ROOF CURB <br />6. ROOF TOP UNITS <br />SHALL HAVE AIR SIDE ECONOMIZERS. <br />B. CO2 SENSOR <br />7. PROVIDE FACTORY <br />INSTALLED WEATHERPROOF GFI 110 VOLT SERVICE OUTLETS. <br />8. SMOKE DETECTORS SHALL BE INSTALLED ON SUPPLY AND/OR RETURN AIR DUCTS <br />AS REQUIRED BY LOCAL CODE AND AUTHORITIES. <br />DETECTOR SHALL <br />BE FURNISHED AND WIRED BY ELECTRICAL CONTRACTOR AND INSTALLED <br />BY HVAC CONTRACTOR. SMOKE DETECTORS <br />TO SHUT DOWN <br />RTU COMPLETELY INCLUDING CONTROL CIRCUIT. <br />9. ROOF TOP UNITS <br />SHALL BE FULLY EQUIPPED WITH ENERGY MANAGEMENT SYSTEM <br />(EMS) ACCESSORIES AND TO BE CONTROLLED BY EMS. <br />10. ROOF CURBS TO <br />BE INSULATED PER DETAIL ON SHEET AS-1.1 <br />11. EQUIPMENT OPERATION CERTIFICATE (EOC) BY AUTHORIZED MANUFACTURER'S REPRESENTATIVE. <br />12. NUMBER ROOF TOP UNITS AS INDICATED ON STAPLES EMS SYSTEM. <br />13. LANDLORD SHALL <br />PROVIDE ALL REQUIRED PREVENTATIVE MAINTENANCE AND FILTER <br />CHANGES BEFORE TURN OVER TO <br />STAPLES, PER LEASE REQUIREMENTS. <br />14. ROOF TOP UNIT DISCONNECTS - SEE RESPONSIBILITY SCHEDULE. <br />15. ROOF TOP UNITS <br />SHALL BE POWERED AND RUNNING AT TIME OF INSTALLATION, STARTUP PROCEDURE BY HVAC CONTRACTOR. <br />16. ROOF TOP UNITS <br />SHALL BE CAPABLE OF OPERATING STANDALONE BYPASSING NOVAR CONTROLLER. <br />EF SCHEDULE <br />UNIT NO. <br />TEF-1 <br />LOCATION <br />ROOF MOUNTED <br />AREA SERVED <br />TOILETS <br />SERVICE <br />EXHAUST <br />FAN TYPE <br />CENTRIFUGAL <br />CFM-TOTAL <br />550 <br />E.S.P.,IN.,W.G. <br />0.5 <br />FAN RPM <br />1550 <br />DRIVE <br />DIRECT <br />MOTOR HP -MIN. <br />1 /4 <br />MOTOR RPM <br />1100 <br />VOLTS/HZ/PHASE <br />120/60/1 <br />MOTOR ENCLOSURE <br />ODP <br />SONES <br />5.7 <br />VIBRATION ISOLATORS <br />RUBBER <br />IN SHEAR <br />ROOF OPENING <br />11.5"x11.5" <br />MFR. <br />SEE SPECIFICATIONS <br />MODEL # <br />SEE SPECIFICATIONS <br />REMARKS <br />1. PROVIDE NEW SELF -FLASHING CURB, GRAVITY <br />BACKDRAFT DAMPER, ALUMINUM BIRDSCREEN, <br />DISCONNECT SWITCH. FAN TO BE ENERGIZED <br />FROM LIGHT SWITCH. <br />2. EXTERNAL STATIC PRESSURE CONSISTS OF <br />DAMPERS, DUCTWORK AND AIR DEVICES. <br />3. PROVIDE INTEGRAL MOTOR RATED DISCONNECT <br />SWITCH. <br />AIR DEVICE SCHEDULE <br />TYPE <br />DESCRIPTION <br />NECK <br />FACE <br />DAMPER <br />NOMINAL CFM <br />SIZE <br />RANGE <br />SQUARE CEILING <br />06 <br />6X6 <br />OBD <br />0 - 100 <br />DIFFUSER,MODEL TDC, <br />ALUMINUM <br />06 <br />9X9 <br />OBD <br />100 - 150 <br />CONSTRUCTION, <br />08 <br />12x12 <br />OBD <br />200 <br />A <br />ROUND NECK. <br />10 <br />12xl2 <br />OBD <br />250 <br />12 <br />12x12 <br />OBD <br />300 <br />CL <br />12 <br />1505 <br />OBD <br />350-400 <br />U) <br />14 <br />15x15 <br />OBD <br />450-500 <br />SIDE WALL DIFFUSER - <br />1Ox8 <br />1Ox8 <br />OBD <br />0 -200 <br />® <br />B <br />MODEL 300 FS <br />18x6 <br />18x6 <br />I OBD <br />250 -450 <br />27x8 <br />27x8 <br />OBD <br />500 -800 <br />DRUM LOUVER <br />18x6 <br />18x6 <br />OBD <br />0 - 400 <br />C <br />MODEL DL <br />20x1O <br />20x10 <br />OBD <br />450 - 700 <br />RECTANGULAR CEILING <br />24x24 <br />N/A <br />UP TO 2000 <br />D <br />GRILLE, EGGCRATE - <br />MODEL 50F <br />SURFACE MOUNT <br />12x8 <br />N/A <br />0 - 250 <br />LOUVERED - <br />18x10 <br />N/A <br />300 - 500 <br />MODEL 25RL <br />E <br />24x12 <br />N/A <br />550 - 900 <br />36x14 <br />N/A <br />950 -1500 <br />RECTANGULAR CEILING <br />10x10 <br />12x12 <br />OBD <br />0 - 250 <br />REGISTER LOUVERED - <br />In <br />F <br />MODEL 50F <br />16x16 <br />18x18 <br />OBD <br />300 - 700 <br />22x22 <br />24x24 <br />OBD <br />750 -1300 <br />x <br />w <br />RECTANGULAR LOUVERED <br />18x10 <br />1 8x1 0 <br />OBD <br />300 -400 <br />G <br />FIXED DEFLECTION - <br />® <br />MODEL 4FL <br />DOOR RETURN GRILLE <br />24x12 <br />24x12 <br />N/A <br />0 - 300 <br />H <br />FIXED DEFLECTION - <br />24x20 <br />24x16 <br />N/A <br />600 -800 <br />MODEL CT-700L <br />REMARKS - APPLY TO ALL UNITS: <br />1. MODEL NUMBERS ARE TITUS UNLESS OTHERWISE NOTED. <br />2. PROVIDE 24x24 MODULE FOR ALL DIFFUSERS INSTALLED <br />IN LAY -IN CEILINGS. <br />3. FRAME ALL AIR DEVICES FOR APPROPRIATE CEILING TYPE. <br />4. PROVIDE ALUMINUM FRAME FOR HARD CEILINGS IN TOILETS. <br />LEGEND <br />\IPUH SCHEDULE <br />UN NO. <br />GUH-1 <br />LOCH ON <br />RECEIVI <br />AREAS vED <br />RECE ING <br />CFM - MI IMUM <br />52 <br />CAPACITY - BH - INPUT/OUTPUT <br />0/24.3 <br />FUEL <br />NATURAL GAS <br />GAS PRESSURE - IN. W.C. MIN. <br />5 <br />FAN TYPE <br />PROPELLER <br />DISCHARGE <br />HORIZONTAL <br />FAN MOTOR H.P. <br />1/20 <br />FAN MOTOR RPM <br />1,650 <br />VOLTS/HZ/PHASE <br />115/60/1 <br />ODP <br />FAN MOTOR ENCLOSU E <br />MOUNTING HEIGHT F.F. - MIN. <br />12'-0" <br />FLUE TYPE <br />SINGLE WALL <br />FLUE SIZE - NCHES <br />4 <br />MFR. <br />L NOX <br />MODEL <br />LF24 30A <br />VIDE WITH DISCHARGE LOUVERS. <br />VIDE THERMOSTAT MOUNTED ON WALL. <br />VIDE SPARK -IGNITED, INTERMITTENT SAFETY <br />OT WITH ELECTRONIC FLAME SUPERVISION A <br />ED LOCKOUT. <br />VIDE MANUAL SHUTOFF VALVE AND UNION. <br />/4R <br />7771 <br />SUPPLY AIR DIFFUSER - ARROWS INDICATE <br />90 DEGREE DUCTWORK ELBOW WITH <br />PATTERN. NO PATTERN SHOWN EQUALS 4-WAY <br />TURNING VANES. <br />RETURN AIR GRILLE <br />RADIUS DUCTWORK ELBOW - ROUND <br />OR RECTANGULAR <br />EXHAUST GRILLE <br />(120) <br />ROUND DUCTWORK. DIAMETER INDICATED <br />FLARED SPIN -IN WITH DAMPER AND <br />FLEX DUCT CONNECTION) <br />IN INCHES <br />(DIFFUSER <br />RECTANGULAR DUCTWORK. SIZE INDICATED IN <br />ROUND DUCT BRANCH TAKE -OFF FROM <br />20X12 <br />INCHES, FIRST NUMBER IS SIDE SHOWN <br />RECTANGULAR MAIN WITH CONICAL TAP <br />20X12 (120) <br />ROUND OR RECTANGULAR METAL DUCTWORK <br />DUCTWORK SIZE TRANSITION <br />FLEXIBLE DUCT <br />SUPPLY OR OUTSIDE AIR DUCT UP <br />SUPPLY OR OUTSIDE AIR DUCT <br />RETURN AIR DUCT <br />SUPPLY OR OUTSIDE AIR DUCT DOWN <br />RETURN AIR DUCT UP <br />RELIEF OR EXHAUST AIR DUCT <br />II�LL���� <br />O <br />THERMOSTAT <br />RETURN AIR DUCT DOWN <br />TS <br />TEMPERATURE SENSOR <br />RELIEF OR EXHAUST AIR DUCT UP <br />CO2 <br />CARBON DIOXIDE SENSOR <br />RELIEF OR EXHAUST AIR DUCT DOWN <br />AFF <br />ABOVE FINISHED FLOOR <br />VOLUME CONTROL DAMPER <br />TYPE OF DIFFUSER/GRILLE <br />A 160 <br />AIRFLOW (CFM) <br />OUTSIDE AIR <br />I <br />CALCULATION <br />RETAIL FLOOR AREA <br />RTU <br />AREA (SF) <br />CFM/S.F. (1) <br />CFM <br />REQUIRED <br />SUPPMLIED <br />RECEIVING AREA <br />RTU-6 <br />2,458 <br />0.15 <br />370 <br />940 <br />SALES FLOOR & COPY CENTER <br />RTU-1,2,3 & 4 <br />14,800 <br />0.3 <br />4,440 <br />4,440 <br />NOTES: <br />(1) PER TABLE 403.3 - FLORIDA BUILDING CODE - MECHANICAL 2004 <br />OFFICE <br />AREA OUTSIDE <br />AIR <br />CALCULATION <br />AREA (S.F.) <br />RTU <br />PEOPLE / S.F. (2) <br />CFM / <br />PERSON (1) <br />CFM REQUIRED <br />CFM SUPPLIED <br />478 <br />RTU- 5 <br />6 <br />20 <br />120 <br />200 <br />NOTES: <br />(1) PER TABLE 403.3 - FLORIDA BUILDING CODE - MECHANICAL 2004 <br />(2) ACTUAL PEOPLE COUNT <br />V <br />C <br />^o <br />W <br />0 <br />Q <br />O <br />V <br />cu000 <br />C <br />Co v- <br />Mc <br />jj���� U <br />W u J U <br />Lu <br />LL co <br />Cm a(D <br />�C > <br />w <br />CD H U) <br />J <br />U <br />L <br />O <br />�L <br />CD <br />_W <br />DL <br />c <br />U) <br />1 <br />O <br />E <br />E <br />O <br />U <br />i <br />CL <br />II <br />N <br />cu co <br />U <br />�=y0 <br />cna� <br />0 <br />mLu <br />Yer <br />a <br />w <br />cn <br />z <br />a <br />CD <br />w <br />cr <br />06 <br />cn <br />cu <br />a� <br />0 <br />w U <br />J Q <br />w <br />w <br />cn <br />z <br />w <br />w <br />Y <br />hizz w <br />CD <br />0 <br />N & " ; <br />0 0 <br />j` CI CD <br />No co col 001 <br />0 <br />z <br />F- <br />rn <br />M <br />cc <br />N <br />Lu <br />it> <br />_ <br />0�1.� <br />U <br />UJI <br />U <br />d <br />C3 <br />M-2 <br />