Laserfiche WebLink
Overall Project Site Plan <br />(PN SCALE: 1" = 40'-0" <br />THIS SET OF DRAWINGS IS LIMITED TO BUILDING B AND ITS ADJACENT SIDEWALKS ONLY. <br />ALL OTHER BUILDINGS AND PARCELS SHALL BE DESIGNED, PERMITTED, AND CONSTRUCTED SEPARATELY. <br />FOR COMPLETE SITE WORK INFORMATION, REFER TO THE CIVIL DRAWINGS PREPARED BY AVID. <br />FOR COMPLETE LANDSCAPE AND IRRIGATION INFORMATION, REFER TO THE CIVIL DRAWINGS PREPARED BY AVID. <br />FOR COMPLETE SITE LIGHTING INFORMATION, REFER TO THE ELECTRICAL DRAWINGS. <br />-0-12"WM <br />FireMarshal's Checklist <br />EGRESS TRAVEL AND EXITS <br />RE: LIFESAFETY PLAN & CODE INFO ON A121 <br />EXIT AND EMERGENCY LIGHTS <br />RE: LIFESAFETY PLAN ON A121 <br />A FIRE ALARM SYSTEM WILL BE DESIGNED AND PERMITTED BY <br />SMOKE DETECTORS <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A121 <br />RE: LIFESAFETY PLAN ON A121 FOR LOCATIONS <br />FIRE EXTINGUISHERS <br />RE: DETAIL 4 ON A121 FOR MOUNTING DETAIL <br />RE: LIFESAFETY PLAN ON A121 FOR LOCATIONS <br />FIRE RATED WALLS <br />RE: DETAILS ON A121 & A122 FOR UL ASSEMBLY DETAILS <br />ALL DOORS SHALL HAVE HARDWARE THAT COMPLIES WITH <br />REQUIREMENTS FOR EGRESS AND ADA ACCESSIBILITY. <br />PANIC HARDWARE <br />RE: LIFESAFETY PLAN ON A121 FOR DOOR LOCATIONS <br />RE: A601 FOR COMPLETE HARDWARE INFORMATION <br />DUCT DETECTORS SHALL BE PROVIDED AS REQUIRED BY SMACNA, NFPA, <br />DUCT DETECTORS <br />AS WELL AS ANY OTHER APPLICABLE CODE <br />RE: MECHANICAL DRAWINGS FOR HVAC INFORMATION <br />EMERGENCY GENERATOR <br />NONE REQUIRED. NONE PROVIDED. <br />RE: LIFESAFETY PLAN ON A121 FOR CALL OUTS FOR EACH ROOM <br />INTERIOR FINISHES <br />RE: SCHEDULE ON A121 FOR SPECIFIC FINISH INFORMATION <br />RE: CODE INFO ON A121 FOR FLAME SPREAD RATINGS <br />SITE PLAN SHOWING ADJACENT <br />RE: OVERALL PROJECT SITE PLAN ON A100. FOR COMPLETE SITE <br />ROADWAYS, BUILDINGS, AND <br />WORK AND UTILITY INFORMATION, RE: CIVIL DRAWINGS BY AVID. <br />FIRE HYDRANTS <br />FULL SYSTEM PROVIDED. TO BE DESIGNED AND PERMITTED BY <br />FIRE ALARM <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A121 <br />FULL SYSTEM PROVIDED. TO BE DESIGNED AND PERMITTED BY <br />SPRINKLERS <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A121 <br />GAS USAGE <br />NONE REQUIRED. NONE PROVIDED. <br />U <br />O <br />O <br />Q- <br />O <br />�Ln <br />V <br />(� CV 00 <br />0= <br />co <br />� L � CO <br />U <br />/11C O <br />E2 cow <br />C2 a)z C35 > <br />z <br />J <br />/� <br />0— Cl) l� in <br />U <br />I <br />O <br />O <br />i <br />UUJ <br />., <br />I <br />C <br />W <br />0 <br />Z <br />06 � 0 <br />O <br />w <br />-J <br />U <br />-0 U3 C1 U) <br />�YNa- <br />o <br />_ <br />o <br />a <br />z <br />o <br />O <br />~ <br />_n <br />M <br />c+> <br />LL1 <br />Lu <br />N <br />w <br />o <br />CD <br />U m <br />Q� <br />LLJ <br />a <br />d' <br />Q <br />CL <br />S <br />o <br />0- <br />O <br />r) <br />U <br />Al 00 <br />