Laserfiche WebLink
SJ1 A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM <br />INDUSTRY STANDARD INSPECTIONS TO ENSURE CONFORMANCE WITH <br />PLANS AND SPECIFICATIONS (IF PROVIDED). SUBMIT REPORTS TO <br />ARCHITECT AND ENGINEER. <br />SJ2 ALL DESIGN, FABRICATION AND ERECTION OF STEEL JOISTS AND <br />BRIDGING SHALL BE IN STRICT ACCORDANCE WITH THE CURRENT <br />SPECIFICATIONS OF STEEL JOIST INSTITUTE AND RECOMMENDED CODE OF <br />STANDARD PRACTICE. <br />SJ3 THE ENDS OF ALL BRIDGING LINES TERMINATING AT WALLS OR BEAMS <br />SHALL BE ANCHORED TO THE WALL OR BEAM. <br />5J4 ALL STEEL JOISTS ARE TO BE CAMBERED AS SPECIFIED BY STEEL JOIST <br />INSTITUTE. <br />SJ5 PROVIDE BOTTOM AND/OR TOP CHORD EXTENSIONS AS SHOWN ON <br />DRAWINGS. <br />SJ6 UNLESS NOTED OTHERWISE, MINIMUM JOIST BEARING SHALL BE 2 1/2" FOR <br />K-SERIES JOISTS, 4" FOR LH, DLH AND SLH 15-18, AND 6" FOR SLH iS-25 <br />ON A STEEL MEMBER OR EMBED PLATE. <br />ail BRIDGING SHALL BE FURNISHED AND INSTALLED TO MEET THE SIZE AND <br />SPACING REQUIREMENTS OF THE SJI STANDARD SPECIFICATIONS FOR <br />OPEN WEB STEEL JOISTS. ALL BRIDGING AND BRIDGING ANCHORS SHALL <br />BE COMPLETELY INSTALLED BEFORE CONSTRUCTION LOADS ARE <br />PLACED ON THE JOISTS. <br />SJS ALL HANGERS, CURBS AND/OR ROOFTOP FRAMES TO SUPPORT <br />MECHANICAL EQUIPMENT, ETC., TO BE SUPPORTED BY THE JOISTS SHALL <br />BE LOCATED AT THE PANEL POINTS OF THE JOISTS. IF THE <br />CONCENTRATED LOAD MUST BE LOCATED FURTHER THAN 6" FROM A <br />PANEL POINT, PROVIDE JOIST STIFFENERS. L2x2x3/16 JOIST STIFFENERS <br />MUST BE INSTALLED FROM LOAD TO OPPOSITE CHORD PANEL POINT <br />BEFORE LOAD IS APPLIED. SEE DETAIL BELOW: <br />CONCENTRATED <br />LOAD ING <br />ADD'L WEB ANGLE REQD <br />Lz_�,._WHEN GREATER THAN 6" <br />ADD'L WEB ANGLE <br />FROM LOAD POINT CONCENTRATED <br />TO OPPOSITE SUSPENDED <br />PANEL POINT LOADING <br />DETAIL AT CONCENTRATED LOADS <br />SJ9 CONTRACTOR TO FURNISH BAR JOIST CERTIFICATIONS SIGNED AND <br />SEALED BY AN ENGINEER REGISTERED IN THE SAME STATE AS THE <br />PROJECT LOCATION. THE SPECIALTY ENGINEER FOR THE STEEL JOIST <br />SUPPLIER SHALL ALSO CERTIFY THAT THE STEEL JOIST BOTTOM CHORDS <br />WILL SAFELY RESIST THE WIND UPLIFTS, CONSIDERING THE SPACING OF <br />BRIDGING. <br />SJ10 PROVIDE UPLIFT BRIDGING PER TABULATED PRESSURES ON SHEET 5103 4 5104. <br />SJ11 ALL ITEMS SUSPENDED FROM JOISTS (I.E. CATWALKS, BALCONIES, <br />OPERABLE PARTITIONS, ETC.) SHALL BE INSTALLED AFTER DEAD LOAD <br />HAS BEEN APPLIED. <br />5J12 BOLTED TIE JOISTS (BTJ) ARE USED IN STEEL FRAMES WHERE COLUMNS <br />ARE NOT FRAMED IN AT LEAST TWO DIRECTIONS WITH STRUCTURAL STEEL <br />MEMBERS. JOieT(5) AT COLUMN LINES SHALL BE FIELD BOLTED AT THE <br />COLUMNS WITH TWO 1/2",P BOLTS TO PROVIDE LATERAL STABILITY <br />DURING CONSTRUCTION. <br />5J13 STEEL JOISTS SHALL RECEIVE SHOP COAT OF PRIMER (COLOR AS <br />DIRECTED BY ARCHITECT) WHERE EXPOSED TO VIEW. ALL OTHER <br />AREAS, INCLUDING THOSE WHICH WILL RECEIVE SFRAY-ON FIRE <br />PROTECTION, SHOULD NOT BE PRIMED. <br />SJ14 ANY STEEL JOIST WITHIN A 4'-0" DISTANCE FROM A PARALLEL SUPPORT <br />SHALL BE FABRICATED IN SUCH A WAY THAT CAMBER OF THE JOIST WILL <br />NOT CAUSE A PROBLEM INSTALLING THE METAL DECK. <br />8J15 IN THE EVENT THAT FIRE SPRINKLERS ARE REQUIRED FOR THIS PROJECT, <br />THE STEEL FABRICATOR SHALL PROVIDE A DIMENSIONED JOIST BRIDGING <br />AND JOIST GIRDER BOTTOM CHORD BRACE FLAN ALONG WITH DETAILS TO <br />THE SPRINKLER CONTRACTOR. THE FABRICATOR AND SPRINKLER <br />CONTRACTOR SHALL COORDINATE WITH EACH OTHER TO ENSURE THAT ANY <br />CONFLICTS ARE RESOLVED BEFORE ANY FABRICATION BEGINS. <br />SJ16 FABRICATOR SHALL ENSURE THAT ALL OSHA REQUIREMENTS ARE MET. <br />PARTICULAR ATTENTION SHALL BE PAID TO THE ERECTION PROCESS, <br />BOLTED CONNECTIONS MAY BE REQUIRED. SUBMIT DETAILS FOR <br />APPROVAL. <br />SJ1-1 THE JOIST MANUFACTURER MAY NOT INCREASE ALLOWABLE STRESSES. <br />SJ18 THE OPEN WEB STEEL JOISTS SHALL BE FABRICATED AND ERECTED IN <br />FULL CONFORMANCE WITH THE "OSHA STEEL ERECTION STANDARD". IF <br />THE CONSTRUCTION DRAWINGS DEVIATE FROM THE OSHA STANDARD THEN <br />THE FABRICATOR SHALL PROVIDE SUBMITTALS THAT CLEARLY INDICATE <br />THE DEVIATION WITH A REVISION CLOUD AND REQUEST APPROVAL FROM <br />BBM TO MAKE THE CHANGE SO THAT CONFORMANCE WITH THE OSHA <br />STANDARD IS ASSURED. <br />5J1e THE SUPPORTS FOR SCISSOR, ARCHED CHORDS OR ANY OTHER SIMILAR <br />TYPE JOIST, UNLESS NOTED OTHERWISE, SHALL BE DESIGNED WITH A <br />PINNED CONNECTION AT ONE END AND A HORIZONTAL ROLLER AT THE <br />OTHER END. THE SUFPORTING STRUCTURE, UNLESS NOTED OTHERWISE, HAS <br />NOT BEEN DESIGNED FOR ANY GRAVITY LOAD HORIZONTAL FORCE DUE <br />TO DEFLECTION. DO NOT DESIGN THESE TYPE OF JOISTS WITH PINNED <br />SUPPORTS EACH END. <br />eTEEL JOI Te CONT' <br />SJ20 ALL PIPES MUST BE SUPPORTED AS SHOWN BELOW: <br />EQUAL EQUAL <br />BEAM CLAMP (TYP) JOIST - SEE PLAN - <br />ALL -THREAD <br />ROD (TYF) 4"0 PIPE TRAPEZE <br />� 10' -0" OC MAX <br />HANGER RING (TYP) <br />5" OR 6114 PIPE 4"-P AND SMALLER <br />PARALLEL TO PIPES MAY BE <br />JOISTS REQUIRES SUPPORTED FROM <br />TRAPEZE A SINGLE JOIST. <br />PROVIDE HANGERS <br />AT 10' -0" OC MAX - <br />FOR PIPES PERPENDICULAR TO JOISTS - <br />PROVIDE HANGERS AT EVERY JOIST FOR <br />5"4,AND 6",P PIPES, AND AT EVERY OTHER <br />JOIST FOR 4"0 AND SMALLER PIPES <br />NOTES: <br />I. LOCATE HANGERS WITHIN 6" OF THE JOIST TOP CHORD <br />PANEL POINTS. <br />2. PIPES LARGER THAN 6'I SHALL BE SUBMITTED TO ARCHITECT <br />FOR APPROVAL PRIOR TO FABRICATION OF JOISTS. INCLUDE <br />LOCATION OF PIPE AND PREFERRED HANGING DETAIL IF <br />OTHER THAN INDICATED ABOVE. JOISTS SHALL BE SPECIALLY <br />DESIGNED BY THE FABRICATOR TO SUPPORT PIPES LARGER <br />THAN 6". THE WEIGHT OF THE PIPES LARGER THAN 6" IS NOT <br />INCLUDED IN THESE DOCUMENTS UNLESS SPECIFICALLY <br />INDICATED OTHERWISE. COORDINATE WITH APPLICABLE <br />TRADES. <br />3. DESIGN OF LATERAL BRACING FOR SUSPENDED FIFES IN <br />SEISMIC AREAS SHALL BE SUBMITTED TO ARCHITECT FOR <br />APPROVAL. <br />4.. FIFES SUSPENDED IN CONFORMANCE WITH THIS DETAIL WILL <br />LIMIT THE PIPE SYSTEM WEIGHT TO 3.5 PSF EQUIVALENT <br />DISTRIBUTED LOAD. <br />TYPICAL PIPE HANGER DETAIL. <br />L f GHTC AGE 1'lE TAL f=fRAM f NG <br />LMF1 A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM <br />INDUSTRY STANDARD INSPECTIONS TO ENSURE CONFORMANCE WITH <br />PLANS AND SPECIFICATIONS (IF PROVIDED). SUBMIT REPORTS TO <br />ARCHITECT AND ENGINEER. <br />LMF2 <br />LMF3 <br />LMF4 <br />LMF5 <br />LMF6 <br />CONNECT STEEL STUDS AND TRACKS TO A36 STEEL OR CONCRETE <br />WITH (2) POWDER ACTUATED FASTENERS (FAF) AT EACH STUD, AND <br />CONNECT STEEL STUDS AND TRACKS TO EACH OTHER WITH (2) #8-18 <br />SCREWS AT EACH STUD (TYPICAL UNLESS NOTED OTHERWISE). SEE <br />ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND EXTENTS <br />OF STEEL STUD WORK. <br />NOTE: "POWDER ACTUATED FASTENER (FAF)" REFERS TO 0.1450 <br />SHANK DOMED -HEAD, LOW -VELOCITY FOWDER ACTUATED <br />FASTENERS AS MANUFACTURED BY POWERS RAWL OR APPROVED <br />EQUAL WITH MINIMUM CAPACITIES AS FOLLOWS: <br />CONCRETE: 1 1/2" FENETF ATION = 1850 PULLOUT $ 225# SHEAR <br />IN A36 STEEL: 1/4" MATERIAL = 4300 PULLOUT 4 6600 SHEAR <br />(PIN MUST FULLY PENETRATE THE MATERIAL BY <br />1/4" MINIMUM) <br />STEEL STUDS SHALL MEET FOLLOWING DESIGN CRITERIA: GALV G-60 <br />ASTM A525, MINIMUM YIELD STRESS SHALL BE 50000 PSI FOR 12ga, 14ga, <br />16ga AND 33000 PSI FOR 18ga 4 20ga. <br />STUD SIZE <br />EFFECTIVE <br />MINIMUM I <br />EFFECTIVE <br />MINIMUM S <br />3 5/8"x16 GA <br />.8549 <br />.4388 <br />3 5/8"x18 GA <br />.6941 <br />.3652 <br />3 5/8"x20 GA <br />.5354 <br />.2608 <br />4"x16 GA <br />1.0152 <br />.502-1 <br />4"x18 GA <br />.8i22 <br />.41-1i <br />411x20 GA <br />6rt22 <br />.2589 <br />6 "xl6 GA <br />2.8033 <br />88i2 <br />6 "x18 GA <br />2.26-15 <br />1328 <br />6 "x20 GA <br />1.1421 <br />B234 <br />8"x14 GA <br />6.9471 <br />1.100-1 <br />8"x16 GA <br />5.11 <br />1.34-10 <br />8"x18 GA <br />4.5454 <br />1.1018 <br />8"x20 GA <br />3.48i6 <br />.(o684 <br />NOTES: <br />1. NOT ALL SIZES MAY BE USED. SEE PLANS AND SECTIONS FOR <br />SfZE(S) REQUIRED. (SIZES AND GAGES ON STRUCTURAL DWGS <br />SHALL GOVERN OVER ARCHITECTURAL DWGS) <br />2. ALL SIZES SHALL HAVE 1-5/8" FLANGES. <br />BRACING DURING CONSTRUCTION: <br />PROVIDE 1 1/2" COLD -ROLLED CHANNELS OR HORIZONTAL STRAP <br />BRACING FOR WALLS IMMEDIATELY AFTER STUDS ARE ERECTED. <br />EXECUTION: <br />POSITION STUDS VERTICALLY IN RUNNERS AND SPACE NO GREATER THAN <br />16". SECURELY ANCHOR EACH STUD TO RUNNER WITH (4) 08-18 <br />LOW -PROFILE SCREWS, TWO AT TOP AND TWO AT BOTTOM, WITH ONE <br />SCREW IN EACH FLANGE. TRACKS SHALL BE SECURELY ANCHORED TO <br />THE SUPPORTING STRUCTURE AS SHOWN ON THE PLANS. AT TRACK BUTT <br />JOINTS, ABUTTING PIECES OF TRACK SHALL BE SECURELY ANCHORED TO <br />A COMMON STRUCTURAL ELEMENT, OR THEY SHALL BE BUTT -WELDED OR <br />SPLICED TOGETHER. JACK STUDS OR CRIPPLES SHALL BE INSTALLED <br />BELOW WINDOW SILLS, ABOVE WINDOW AND DOOR HEADS, AT FREE <br />STANDING STAIR RAILS, AND ELSEWHERE TO FURNISH SUPPORT, AND <br />SHALL BE SECURELY ATTACHED TO SUPPORTING MEMBERS. PROVISIONS <br />FOR STRUCTURE VERTICAL MOVEMENT SHALL BE PROVIDED WHERE <br />INDICATED ON THE PLANS. 5PL ICES IN AXIALLY LOADED STUDS SHALL <br />NOT BE PERMITTED. <br />EXTERIOR SHEATHING: <br />ATTACH GYPSUM SHEATHING TO EXTERIOR OF EACH STUD WITH 1" <br />TYPE(5) 5-12 COATED SCREWS SPACED 3/8" FROM ENDS AND EDGES <br />AND AT APPROXIMATELY 8" OC. <br />LMF_1 LATERAL BRACING (HORIZONTAL BRIDGING) FOR WALLS: <br />(NOTE: IF NON -LOAD -BEARING WALLS (PARTITION WALLS OR CURTAIN <br />WALLS) HAVE SHEATHING ON BOTH SIDES, LATERAL BRACING IS NOT <br />REQUIRED.) <br />ENSURE BOTH STUD FLANGES ARE ATTACHED TO TOP AND BOTTOM <br />RUNNER FLANGES. HORIZONTAL BRIDGING MUST BE INSTALLED AT <br />SPACING NOT TO EXCEED 48" OC FOR AXIAL LOAD BEARING WALLS <br />AND 6 0" OC MEASURED VERTICALLY FOR NON -LOAD -BEARING WALLS <br />CARRYING WIND LOAD ONLY. (TYPICAL FOR ALL OPTIONS BELOW.) <br />16ga V-BAR BRIDGING <br />ATTACHED TO BOTH <br />FLANGES. SEE NOTES <br />FOR SPAC ING. <br />(1) *110 <br />(TYP) <br />TIV � MTL STUD - SEE PLAN <br />HORIZONTAL BRIDGING - OPTION #1 <br />5/8" TYPE S -12 <br />LOW PROFILE <br />HEAD SCREWS <br />ID BRIDGING <br />RUNNER) <br />1 1/2"-20 GAGE <br />STRAP BRIDGING <br />STUD <br />HORIZONTAL BRIDGING CONSISTS OF CUT -TO -LENGTH RUNNER FOR <br />SOLID BRIDGING AND STEEL STRAPS ON BOTH SIDES OF STUD. <br />SOLID BRIDGING 15 PLACED AT EA END OF WALL, ADJACENT TO <br />WALL OFENINGS AND 8'-0" OC MAX, MEASURED VERTICALLY. <br />RUNNER HAS WEB FLANGE BENT AT EACH END AND IS SECURED TO <br />EACH STUD FLANGE WITH ONE 5/8" TYPE 5-12 LOW PROFILE SCREW. <br />STRAP BRIDGING OF 1 1/2" WIDE BY 20ga STEEL IS FASTENED TO <br />EACH STUD FLANGE WITH ONE 5/8" TYPE 5-12 SCREW AND TO EACH <br />RUNNER FLANGE WITH FOUR SCREWS. <br />HORIZONTAL BRIDGING - OPTION #2 <br />v <br />1 1/2" COLD ROLLED CHANNELS MAY BE USED IN LIEU OF ABOVE <br />DETAIL TO BRACE STUDS LATERALLY. CHANNELS ARE INSERTED <br />THROUGH STUD WEB HOLES AND SECURED WITH SCREW -ATTACHED <br />1 1/2 "x2 "x16ga CLIP ANGLES CUT TO LENGTH 1/4" LESS THAN STUD WIDTH. <br />HORIZONTAL BRIDGING - OPTION #3 <br />LMFB METAL STUD INSTALLATION: <br />METAL STUDS SHALL EXTEND INTO ALL TRACKS UNTIL IT IS WITHIN 1/2" <br />OF THE TRACK WEB. <br />NO METAL STUD TRACK SHALL EXTEND PAST THE EDGE OF THE <br />SUPPORT MORE THAN ONE THIRD OF ITS WIDTH ( s.g. A 6" TRACK MAY <br />EXTEND BEYOND THE EDGE OF SUPPORT A MAX OF 6/3 =2 "). <br />• �=Evd•► <br />AAC <br />AUTOCLAVED AERATED <br />lb, * <br />POUND(S) <br />CONCRETE <br />LG <br />LONG <br />AB <br />ANCHOR BOLT <br />LL <br />LIVE LOAD <br />ABV <br />ABOVE <br />LLBB <br />LONG LEG BACK-TO-BACK <br />A.C.I. <br />AMERICAN CONCRETE INSTITUTE <br />LLH <br />LONG LEG HORIZONTAL <br />ADDL <br />ADDITIONAL <br />LLV <br />LONG LEG VERTICAL <br />AFF <br />ABOVE FINISH FLOOR <br />LNTL <br />LINTEL <br />AGGR <br />AGGREGATE <br />LSL <br />LONG SLOTTED <br />A.I.S.C. <br />AMERICAN INSTITUTE OF STEEL <br />LOG <br />LOCATION <br />CONSTRUCTION <br />LONG <br />LONGITUDINAL <br />A.-5-I. <br />AMERICAN IRON AND STEEL <br />LP <br />LOW POINT <br />INSTITUTE <br />LW <br />LONG WAY <br />AL <br />ALUMINUM <br />ALT <br />ALTERNATE <br />MAS <br />MASONRY <br />AR <br />ANCHOR ROD <br />MAX <br />MAXIMUM <br />ARCH <br />ARCHITECT(URAL) <br />MB <br />MACHINE BOLT <br />ASTM <br />AMERICAN SOCIETY OF TESTING <br />MBM <br />METAL BUILDING MFR <br />MATERIALS <br />MC <br />MOMENT CONNECTION <br />A.W.S. <br />AMERICAN WELDING SOCIETY <br />MCJ <br />MASONRY CONTROL JT <br />ME <br />MONOLITHIC EDGE <br />B/ <br />BOTTOM OF <br />MECH <br />MECHANICAL <br />BB <br />BOND BEAM <br />MEZZ <br />MEZZANINE <br />BLDG <br />BUILDING <br />MF <br />MONOLITHIC FOOTING <br />BLW <br />BELOW <br />MFR <br />MANUFACTURE(ER) <br />BM <br />BEAM <br />MIN <br />MINIMUM <br />BOT <br />BOTTOM <br />MIS( <br />MISCELLANEOUS <br />BP <br />BASE PLATE <br />MO <br />MASONRY OPENING <br />BRDG <br />BRIDGING <br />MS <br />METAL STUD <br />BRG <br />BEARING <br />MTL <br />METAL <br />BRK <br />BRICK <br />MWF <br />MONOLITHIC WALL FOOTING <br />BS <br />BOTH SIDES <br />BTJ <br />BOLTED TIE JOIST <br />NIC <br />NOT IN CONTRACT <br />BTWN <br />BETWEEN <br />NS <br />NEAR SIDE <br />NTS <br />NOT TO SCALE <br />C/C <br />CENTER TO CENTER <br />CANT <br />CANTILEVER <br />CA <br />OVERALL <br />CB <br />CONCRETE BEAM <br />OC <br />ON CENTER <br />CC <br />CONCRETE COLUMN <br />OD <br />OUTSIDE DIAMETER <br />CFS <br />COLD -FORMED STEEL <br />OF <br />OUTSIDE FACE <br />CIF <br />CAST- IN -PLACE <br />OH <br />OPPOSITE HAND / OVERHEAD <br />CJ <br />CONSTRUCTION JOINT (OR <br />OFNG <br />OPENING <br />CONTROL JOINT) <br />OFF <br />OPPOSITE <br />4-:, CL <br />CENTERL INE <br />CLR <br />CLEARANCE) <br />FAF <br />POWDER -ACTUATED <br />CM <br />CONSTRUCTION MANAGER <br />FASTENERS) <br />CMU <br />CONCRETE MASONRY UNIT <br />PB <br />Pf AST BEAM <br />COL <br />COLUMN <br />FEMB <br />PRE-ENGINEERED METAL <br />CON( <br />CONCRETE <br />BUILDING <br />CONN <br />CONNECTION <br />PERF <br />PERPENDICULAR <br />CONT <br />CONTINUOUS <br />PC <br />PRECAST <br />CONTR <br />CONTRACTOR <br />iF_, PL <br />PLATE <br />COORD <br />COORDINATE <br />PLS <br />PLACES <br />CSK <br />COUNTER SfNK <br />PLF <br />POUNDS PER LINEAR FOOT <br />CTR <br />CENTER <br />PLYWD <br />PLYWOOD <br />CTRD <br />CENTERED <br />PNL <br />PANEL <br />CY <br />CUBIC YARD <br />PSF <br />POUNDS PER SQUARE FOOT <br />PSI <br />POUNDS PER SQUARE INCH <br />DBA <br />DEFORMED BAR ANCHOR <br />PTN <br />PARTITION <br />D IA <br />DIAMETER <br />D IAG <br />DIAGONAL <br />R <br />RADIUS <br />DL <br />DEAD LOAD <br />RC <br />REINFORCED CONCRETE <br />DN <br />DOWN <br />REF <br />REFERENCE <br />DTL <br />DETAIL <br />REINF <br />REINFORCED) (ING) <br />DWG <br />DRAWING <br />REQ <br />REQUIRE <br />DWL <br />DOWEL <br />REQ'D <br />REQUIRED <br />RF <br />ROOF <br />EA <br />EACH <br />RM <br />ROOM <br />EE <br />EACH END <br />RP <br />RADIUS POINT <br />EF <br />EACH FACE <br />RTN <br />RETURN <br />EJ <br />EXPANSION JOINT <br />RW <br />RETAINING WALL <br />ENG <br />ENGINEER <br />EOS <br />EDGE OF SLAB <br />SCH <br />SCHEDULE <br />EL <br />ELEVATION <br />SDI <br />STEEL DECK INSTITUTE <br />EQ <br />EQUAL <br />SECT <br />SECTION <br />Ea SF <br />EQUAL SFACE(S) (ING) <br />SF <br />STEPPED FOOTING <br />ES <br />EACH SIDE <br />SHT <br />SHEET <br />EW <br />EACH WAY <br />51M <br />SIMILAR <br />EXF <br />EXPANSION <br />SJ <br />SAWCUT JOINT <br />EXT <br />EXTERIOR <br />SJI <br />STEEL JOIST INSTITUTE <br />SL <br />SLOPE <br />F/ <br />FACE OF <br />5LB8 <br />SHORT LEG BACK-TO-BACK <br />FBC <br />FLORIDA BUILDING CODE <br />SOG <br />SLAB ON GRADE <br />FD <br />FLOOR DRAIN <br />SP <br />SPACE(S) <br />FDN <br />FOUNDATION <br />SPECS <br />SFECfFICATIONB <br />FF <br />FINISHED FLOOR <br />SQ <br />SQUARE <br />FIN <br />FL <br />F <br />SS <br />STAINLESS STEEL <br />FLG <br />FLOOR <br />FLANGE <br />SSL <br />SHORT SLOTTED <br />FMG <br />FRAMING <br />STD <br />STANDARD <br />FS <br />FAR SIDE <br />STfFFR <br />STIFFENER <br />FT <br />FOOT <br />FTG <br />FOOTING <br />STL <br />STEEL <br />ga <br />GAUGE <br />STR <br />STRENGTH <br />GALV <br />GALVANIZED) <br />STRL <br />STRUCTURAL <br />GB <br />GRADE BEAM <br />SW <br />SHORT WAY / SHEAR WALL <br />GC <br />GENERAL CONTRACTOR <br />SYMM <br />SYMMETRICAL <br />GFC <br />GROUT FILLED CELL(5) / COURSE <br />SYP <br />SOUTHERN YELLOW PINE <br />GLB <br />GLU-LAM BEAM <br />GR <br />GRADE <br />T45 <br />TOP AND BOTTOM <br />TB <br />TIE BEAM <br />HC <br />HOLLOW -CORE <br />TC <br />TIE COLUMN <br />HK <br />HOOK <br />TEMP <br />TEMPERATURE <br />HORIZ <br />HORIZONTAL <br />THK <br />THICK <br />HP <br />HIGH POINT <br />TOFG <br />TOPPING <br />HS <br />HEADED STUD <br />TRANS <br />TRANSVERSE <br />HSS <br />HOLLOW STRUCTURAL SECTION <br />TYP <br />TYPICAL <br />T/ <br />TOP OF <br />ID <br />INSIDE DIAMETER <br />UNO <br />UNLESS NOTED OTHERWISE <br />IF <br />INSIDE FACE <br />INT <br />INTERIOR <br />VIF <br />VERIFY IN FIELD <br />VERT <br />VERTICAL <br />JST <br />JOIST <br />JT <br />JOINT <br />WD <br />WOOD <br />WF <br />WALL FOOTING <br />K <br />KIP <br />WO <br />WINDOW OPENING (MASONRY) <br />KO <br />KNOCK -OUT <br />WP <br />WORKING-: POINT <br />WS <br />WATERSTOP <br />WWF <br />WELDED WIRE FABRIC <br />W/ <br />WITH <br />B-B- <br />E <br />0 <br />m <br />c <br />0 <br />m <br />STRUCTURAL ENGINEERS - <br />Orlando Boca Raton G <br />P:407.645.3423 <br />F:407.645.3790 0 <br />1912 Boothe Circe Suite 100 ii <br />0 <br />Longwood, FL 32750 0 <br />bbmstructural,com <br />EB5343 <br />Bora Erbilen P.E. #55996 <br />ENGINEER HEREBY EXPRESSLY RESERVES HIS <br />COMMON LAW COPYRIGHT AND OTHER PROPERTY <br />RIGHTS IN THESE PLANS. THIS DESIGN AND <br />DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED, <br />OR COPIED IN ANY FORM OR MANNER WHATSOEVER <br />WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN <br />PERMISSION AND CONSENT OF "BURTON BRASWELL <br />MIDDLEBROOKS ASSOCIATES', NOR ARE THEY TO BE <br />ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING <br />SAID WRITTEN PERMISSION AND CONSENT. <br />a3 8 <br />0 <br />(3 <br />C <br />0 <br />Q <br />0 <br />L_ <br />CD <br />(0 CD: 00 <br />U_ J Y) <br />. L U cM C <br />J.O <br />VJ LL <br />E2 caLL <br />:E <br />z <br />i 0') 0- a) <br />W <br />� LrM- -I'_J co W <br />0 <br />0 <br />E <br />E <br />0 <br />V <br />>>o <br />i co <br />J <br />NFL <br />m::)`�o <br />LU <br />°6:EU <br />z <br />(�.- >, 0 <br />�cn0-U) <br />LU <br />0 <br />WYN <br />Z <br />wM <br />J M <br />�LO <br />"' 4t <br /><w <br />0ic <br />m <br />0 <br />N <br />0 <br />.cn <br />E <br />- <br />LU <br />v, <br />W <br />J <br />w <br />0 <br />Z <br />O <br />00 <br />O <br />P <br />LU <br />LU <br />N <br />o <br />Z <br />U_ <br />v <br />M <br />w <br />v <br />d <br />0 <br />0 <br />File=F: \2007\07146\07146_TECH\07146_SDWGS\07146-Sdwgs\RETAIL D\07146_S003.dwg Tab=S003 Date/Time= Apr 07, 2008 - 1: 30pm Plot by feid <br />