Laserfiche WebLink
List Of Abbreviations <br />A <br />A/C <br />AIR CONDITION <br />E <br />EL <br />ELEVATION <br />L <br />LAV <br />LAVATORY <br />S <br />SC <br />SOLID CORE <br />AB <br />ANCHOR BOLT <br />ELEC <br />ELECTRICAL <br />LBL <br />LABEL <br />SCHED <br />SCHEDULE <br />ACT <br />ACOUSTICAL CEILING TILE <br />ELEV <br />ELEVATOR <br />LBS <br />POUNDS <br />SCP <br />SCUPPER <br />AD <br />ADJUSTABLE, ADJACENT <br />EMER <br />EMERGENCY <br />LF <br />LINEAR FEET <br />SD <br />SOAP DISPENSER <br />AFF <br />ABOVE REF FINISHED <br />EQ <br />EQUAL <br />LT WT <br />LIGHT WEIGHT <br />SEAL <br />SEALANT <br />FLOOR (SLAB) <br />EQUIP <br />EQUIPMENT <br />SECT <br />SECTION <br />AHU <br />AIR HANDLER UNIT <br />ESC <br />ESCALATOR <br />M <br />MAS <br />MASONRY <br />SF <br />SQUARE FEET <br />ALT <br />ALTERNATE <br />EWC <br />ELECTRIC <br />MAX <br />MAXIMUM <br />SHT <br />SHEET <br />ALUM <br />ALUMINUM <br />WATER COOLER <br />MECH <br />MECHANICAL <br />SIM <br />SIMILAR <br />ANOD <br />ANODIZED <br />EXIST <br />EXISTING <br />MFR <br />MANUFACTURER <br />SPEC <br />SPECIFICATION <br />APPROX APPROXIMATE <br />EXP <br />EXPANSION <br />MH <br />MANHOLE <br />SS <br />STAINLESS STEEL, <br />ARCH <br />ARCHITECT <br />EXT <br />EXTERIOR <br />MIN <br />MINIMUM <br />SERVICE SINK <br />AUTO <br />AUTOMATIC <br />MIN <br />MINIMUM, MINUTE <br />STD <br />STANDARD <br />F <br />FACP <br />FIRE ALARM <br />MISC <br />MISCELLANEOUS <br />STL <br />STEEL <br />B <br />B 0 <br />BOTTOM OF <br />CONTROL PANEL <br />MLDG <br />MOLDING <br />STOR <br />STORAGE <br />BD <br />BOARD <br />FD <br />FLOOR DRAIN <br />MO <br />MASONRY OPENING <br />STRUC <br />STRUCTURAL <br />BLDG <br />BUILDING <br />FDN <br />FOUNDATION <br />MR <br />MOISTURE RESISTANT <br />SUSP <br />SUSPENDED <br />BM <br />BEAM <br />FIN <br />FINISHED <br />MTD <br />MOUNTED <br />SY <br />SQUARE YARD <br />BRG <br />BEARING <br />FLR <br />FLOOR <br />MTL <br />METAL <br />BTM <br />BOTTOM <br />FR <br />FIRE RESISTANT <br />MUL <br />MULLION <br />T <br />T <br />TREAD <br />BUR <br />BUILT UP ROOF <br />FR-S <br />FIRE -RETARDANT <br />T&G <br />TONGUE & GROOVE <br />WOOD TREATMENT <br />N <br />NIC <br />NOT IN CONTRACT <br />TBL <br />TABLE <br />C <br />CB <br />CATCH BASIN <br />FT <br />FEET, FOOT <br />NOM <br />NOMINAL <br />TELE <br />TELEPHONE <br />CG <br />CORNER GUARD <br />FTG <br />FOOTING <br />NTS <br />NOT TO SCALE <br />TEMP <br />TEMPERED <br />Cl <br />CAST IRON <br />FURR <br />FURRING <br />THK <br />THICK <br />CJ <br />CONTROL JOINT <br />FLIT <br />FUTURE <br />0 <br />OC <br />ON CENTER <br />TLT <br />TOILET <br />CL <br />CENTER LINE <br />OD <br />OUTSIDE DIAMETER <br />TO <br />TOP OF <br />CLG <br />CEILING <br />G <br />GA <br />GAUGE <br />OPP <br />OPPOSITE <br />TPD <br />TOILET PAPER <br />CLO <br />CLOSET <br />GAL <br />GALLON <br />OVFL <br />OVERFLOW <br />DISPENSER <br />CLR <br />CLEAR <br />GALV <br />GALVANIZED <br />TS <br />TUBE STEEL <br />CMU <br />CONCRETE <br />GB <br />GRAB BAR <br />P <br />PL <br />PLATE <br />TV <br />TELEVISION <br />MASONRY UNIT <br />GC <br />GENERAL CONTRACTOR <br />PLAM <br />PLASTIC LAMINATE <br />TYP <br />TYPICAL <br />CO <br />CLEAN OUT <br />GYP <br />GYPSUM <br />PLAS <br />PLASTER <br />COL <br />COLUMN <br />PLBG <br />PLUMBING <br />U <br />LION <br />UNLESS OTHER- <br />CONC <br />CONCRETE <br />H <br />HB <br />HOSE BIBB <br />PLWD <br />PLYWOOD <br />WISE NOTED <br />CONST <br />CONSTRUCTION <br />HC <br />HOLLOW CORE <br />PNL <br />PANEL <br />UTIL <br />UTILITY <br />CONT <br />CONTINUOUS <br />HDW <br />HARDWARE <br />PR <br />PAIR <br />CONTR <br />CONTRACTOR <br />HM <br />HOLLOW METAL <br />PREFAB <br />PREFABRICATED <br />V <br />VB <br />VINYL BASE <br />CORR <br />CORRIDOR <br />HORIZ <br />HORIZONTAL <br />PT <br />POINT <br />VCT <br />VINYL COMPOSITE TILE <br />CT <br />CERAMIC TILE <br />HR <br />HOUR <br />PT <br />PRESSURE TREATED <br />VERT <br />VERTICAL <br />CTR <br />CENTER <br />HT <br />HEIGHT <br />PTD <br />PAPER TOWEL DISPENSER <br />VEST <br />VESTIBULE <br />CU <br />CONDENSING UNIT <br />HTG <br />HEATING <br />PVC <br />POLY VINYL CLORIDE <br />VIF <br />VERIFY IN FIELD <br />CW <br />COLD WATER <br />HVAC <br />HEATING, VENTILATING <br />VTR <br />VENT THRU ROOF <br />& AIR CONDITIONING <br />Q <br />QT <br />QUARRY TILE <br />VWC <br />VINYL WALL COVERING <br />D <br />DBL <br />DOUBLE <br />HW <br />HOT WATER <br />DEPT <br />DEPARTMENT <br />R <br />R <br />RADIUS, RISER, <br />W <br />W <br />WIDTH <br />DET <br />DETAIL <br />I <br />ID <br />INSIDE DIAMETER <br />THERMAL RESISTANCE <br />W/ <br />WITH <br />DF <br />DRINKING FOUNTAIN <br />IN <br />INCH <br />RD <br />ROOF DRAIN <br />W/O <br />WITHOUT <br />DIA <br />DIAMETER <br />INCL <br />INCLUDING <br />RECP <br />RECEPTACLE <br />WC <br />WATER CLOSET <br />DIM <br />DIMENSION <br />INSUL <br />INSULATION <br />REF <br />REFERENCE <br />WD <br />WOOD <br />DISP <br />DISPENSER <br />INT <br />INTERIOR <br />REFR <br />REFRIGERATOR <br />WH <br />WATER HEATER <br />DN <br />DOWN <br />INV <br />INVERT <br />REG <br />REGLET <br />WP <br />WATERPROOF <br />DS <br />DOWNSPOUT <br />REINF <br />REINFORCEMENT <br />WT <br />WEIGHT <br />DWG <br />DRAWING <br />J <br />JAN <br />JANITOR <br />REQ <br />REQUIRED <br />WWF <br />WELDED WIRE FABRIC <br />E <br />JB <br />JUNCTION BOX <br />REV <br />REVISION <br />WWM <br />WELDED WIRE METAL <br />EA <br />EACH <br />JT <br />JOINT <br />RM <br />ROOM <br />EB <br />EXPANSION BOLT <br />RND <br />ROUND <br />Y <br />YD <br />YARD <br />EIFS <br />EXTERIOR INSULATING <br />L <br />L <br />LENGTH <br />RO <br />ROUGH OPENING <br />FINISH SYSTEM <br />LAM <br />LAMINATE <br />RTU <br />ROOF TOP UNIT <br />EJ <br />EXPANSION JOINT <br />Legend <br />&__ GRID DESIGNATION <br />F10-21 ROOM NUMBER <br />102A DOOR NUMBER <br />® WINDOW TYPE <br />2O STOREFRONT TYPE <br />❑3 -- WALL TYPE <br />KEY NOTE <br />© REVISION NUMBER <br />-OCI SOMETHING ELEVATIONS TAGS <br />SPOT ELEVATION TAG <br />• <br />NORTH ARROW NE7W <br />s� Z� BUILDING SECTION <br />A301-2 A301-2 <br />SHEET NUMBER SECTION NUMBER <br />0 WALL SECTION <br />A30�2� <br />SHEET NUMBER SECTION NUMBER <br />A501-6 SECTION DETAIL <br />SHEET NUMBER DETAIL NUMBER <br />A888-88 DETAIL REFERENCE <br />SHEET NUMBER DETAIL NUMBER <br />'? EXTERIOR ELEVATION <br />A201-2 CD MARKERS <br />SHEET NUMBER ELEVATION NUMBER <br />1 <br />4 A401 2 INTERIOR ELEVATION <br />MARKERS <br />SHEET NUMBER 3 ELEVATION NUMBER <br />BRICK <br />. ° , . ° I CONCRETE <br />°• °' <br />PLYWOOD <br />GYPSUM <br />BOARD <br />NO <br />o0 <br />DRAINAGE <br />FILL <br />MASONRY <br />����/� COMPACTEDZ�; <br />EARTH <br />STEEL <br />RIGID <br />INSULATION <br />::::::::::: <br />:: <br />MR <br />BOARD <br />General Notes <br />1. ALL WORK WILL COMPLY WITH LOCAL, STATE, AND NATIONAL CODES <br />RELATED TO THIS PROJECT. <br />2. THE WRITTEN DIMENSIONS PREVAIL ON THE CONSTRUCTION DOCUMENTS, <br />DO NOT SCALE THESE DRAWINGS. CONTRACTOR TO FIELD VERIFYALL <br />DIMENSIONS AND CONDITIONS. IF ANY DISCREPANCY OCCURS, THE <br />CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING BEFORE <br />PROCEEDING WITH ANY WORK AFFECTED BY THE DISCREPANCY. <br />3. CONTRACTORS TO SECURE ALL PERMITS AND REQUIRED INSPECTIONS <br />NECESSARY TO OBTAIN A CERIFICATE OF OCCUPANCY. <br />4. CONTRACTORS ARE TO PROVIDE ALL TEMPORARY UTILITIES AND <br />INFRASTRUCTURE REQUIRED TO PERFORM THE WORK, INCLUDING <br />FIRE PROTECTION AS REQUIRED DURING CONSTRUCTION. <br />5. EACH CONTRACTOR AND SUBCONTRACTOR IS EXPECTED TO REVIEW ALL <br />CONTRACT DOCUMENTS AND SITE CONDITIONS PRIOR TO ISSUED BID. <br />CHANGE ORDERS WILL NOT BE APPROVED FOR FAILURE TO DO S0, <br />6. PRODUCTS SPECIFIED OR OTHERWISE INDICATED IN THE CONTRACT <br />DOCUMENTS SHALL NOT BE SUBSTITUED WITHOUT PRIOR WRITTEN <br />APPROVAL FROM THE ARCHITECT AND OWNER. <br />7. THE CONTRACTOR SHALL HAVE INSTALLATION INSTRUCTIONS FOR <br />ALL EQUIPMENT AND APPLIANCES ON SITE AT TIME OF INSPECTION. <br />8. THIS CONTRACTOR SHALL COORDINATE ALL TRADES REQUIRED TO <br />COMPLETE THIS PROJECT AS REQUIRED TO ACTIVATE THE USE OF <br />THE FACILITY AS PLANNED. <br />9. THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED AND HAS A <br />FULL FIRE ALARM SYSTEM. THESE SYSTEMS SHALL BE MODIFIED <br />AS NEEDED TO PROVIDE FIRE PROTECTION FOR THE SPECIFIED <br />TENANT SPACES. THE CONTRACTOR SHALL SUBMIT SIGNED AND <br />SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE <br />LOCAL JURISDICTION FOR PERMITTING. NO WORK ON THE FIRE <br />PROTECTION SYSTEMS SHALL TAKE PLACE UNTIL THE REQUIRED <br />PERMITS ARE OBTAINED BY THE FIRE PROTECTION SUB <br />CONTRACTOR. <br />10. ALL BUILDING MATERIALS SHALL COMPLY WITH THE REQUIRMENTS <br />OF TYPE II-B CONSTRUCTION. ALL PLYWOOD SHEATHING AND <br />WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED (FRT) <br />11. SEE ENERGY CALCULATION ATTACHED TO THIS SUBMISSION <br />12. ALL WORK ON THE EXISTING BUILDING SHALL BE PERFORMED IN <br />ACCORDANCE WITH ALL EXISTING WARRANTIES. THE <br />CONTRACTOR SHALL CONTACT THE OWNER DIRECTLY TO OBTAIN <br />ALL EXISTING WARRANTY INFORMATION. THE CONTRACTOR SHALL <br />PROVIDE THE OWNER WITH DOCUMENTATION VERIFYING THAT ALL <br />EXISTING WARRANTIES HAVE BEEN MAINTAINED. <br />Legal Description <br />A TRACT OF LAND LYING IN THE NORTHEAST 1/4 OF SECTION 34 AND IN THE NORTHWEST 1/4 OF SECTION 35, TOWNSHIP 25 <br />SOUTH, RANGE 21 EAST, PASCO COUNTY, FLORIDA. THE SAME BEING A PORTION OF THE ZEPHYRHILLS COLONY COMPANT <br />LANDS SUBDIVISION OF SAID SECTION 34 AND 35 AS SHOWN ON THE PLAT OR MAP THEREOF RECORDED IN PLAT BOOK 1, PAGE <br />55 OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br />LESS AND EXCEPT THAT PORTION OF SAID TRACTS 58 AND 59 CONVEYED IN OFFICIAL RECORDS BOOK 1902, PAGE 690, PUBLIC <br />RECORDS OF PASCO COUNTY, FLORIDA. <br />SAID LAND CONTAINING 60.76 ACRES MORE OR LESS. <br />Vicinity Map 'N? <br />NTS <br />Tenant Buildout fior Space B8 con Nr E <br />N 8 <br />M <br />BuildingB at Zephyr Commons�o o <br />7928 Gall Blvd, Zephyrhills, FL o z , <br />_ 06 <br />�--1 ui <br />LL <br />o <br />Ct w <br />a� � a, <br />r-- Cot <br />CID . o ti <br />LO� <br />rB-12) (B- 13) w <br />" j ION <br />MEMO <br />--i <br />1 'MOM <br />_ <br />►�I 101 101 I�I I I I II AM <br />I�I�I�1�1�1 I�I�Irlrl�l I�Irlrl�l�l I�Irl�l��l . I�I�I�lil�l I�I�I`Ir�l��l <br />Scope of Work <br />1. THE SCOPE IS LIMITED TO TENANT SPACE B8 IN BLDG B. <br />2. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO THE PARKING LOT, LANDSCAPING, SITE UTILITIES, <br />SITE DRAINAGE, SITE LIGHTING, OR ANY OTHER SITE FEATURES.. <br />3. THE SCOPE DOES NOT INCLUDE ANY WORK ON ANY OF THE BUILDINGS IN THE SHOPPING CENTER OTHER <br />THAN BLDG B. <br />4. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE SIDEWALKS, HARDSCAPE AREAS, OR LANDSCAPE AEAS <br />IMMEDIATELY ADJACENT TO ANY OF THE BUILDINGS. <br />5. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE FINISHES, AWNINGS, STONE WORK, OR DECORATIVE <br />TRIM ON THE EXTERIOR ELEVATIONS OF ANY OF THE BUILDINGS. <br />6. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE STOREFRONT SYSTEMS, DECORATIVE WINDOWS, <br />FRONT STOREFRONT DOORS, OR REAR HOLLOW METAL DOORS ON ANY OF THE BUILDINGS, <br />7. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE EXISTING ROOF SYSTEM OTHER THAN WHAT IS <br />REQUIRED TO ADD AN EXHAUST FAN AND A VENT FOR THE NEW RESTROOM. THE SCOPE DOES NOT <br />7928 GALL BLVD, ZEPHYRHILLS, FLORIDA INCLUDE ANY WORK ON THE SHINGLE ROOFS OR ON THE ROOF DRAINAGE SYSTEMS. <br />8. THE SCOPE ON THE FRONT FRAMED WALL SHALL BE LIMITED TO WHAT IS NEEDED TO CONSTRUCT THE <br />NEW TENANT DEMISING WALLS. THE EXISTING 1 HOUR FIRE RATING SHALL BE MAINTAINED. <br />9. THE SCOPE INCLUDES TWO NEW TENANT DEMISING WALLS. <br />10. THE SCOPE INCLUDES ADDING SHEATHING OVER METAL FURRING AND RIGID INSULATION ON THE INSIDE <br />Code Information OF THE REAR MASONRY WALL INSIDE THE RESTROOM ONLY. <br />11. THE SCOPE INCLUDES INSTALLING A NEW RESTROOM PER ADA REQUIRMENTS. <br />JURISDICTION AUTHORITY 12. THE SCOPE INCLUDES INSTALLING NEW 2' x 4' ACT CEILINGS IN THE RESTROOM AND THE MAIN ROOM OF <br />REvi `w THE TENANT SPACE. <br />CITY OF ZEPHYRHILLS 3 SIGNED & SEALED SETS FOR PERMIT �iATe , t <br />5335 8TH STREET (813) 780-0020 -PHONE CI'1`Y pF ZEpI�Yi�t�ll�t..���_e. 13 DECK, OR TRUSSES THE SCOPE DOES NOT INCLUDE ANY WORK ON TTHE SCOPE DOES NOT INCLUDE ANY WORK ON THE FOUNDATIONS, � BEAMS, JOISTS, E STRUCTRAL OM ON ROOF <br />OF <br />ZEPHYRHILLS, FL 33542 (813) 780-0021 -FAX CLANS EXAMINER THE MASONRY WALL. THE SCOPE DOES NOT INCLUDE ANY STRUCTURAL WORK TO THE EXISTING LIGHT <br />GAUGE FRAMING. <br />ADOPTED CODES: 14, THE SCOPE INCLUDES SAW -CUTTING THE EXISTING FLOOR SLAB AS NEEDED TO PROVIDE THE NEW <br />BUILDING: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) RESTROOM. <br />FIRE: FLORIDA FIRE PREVENTION CODE - 2007 (WI 2009 AMENDMENTS) 15. THE SCOPE INCLUDES RE -POURING ANY PORTION OF THE EXISTING SLAB THAT IS SAW -CUT. IT ALSO <br />(CHAPTER 36 - NFPA 1 & NFPA 101 W/ STATE FIRE MARSHAL AMENDMENTS) ALL W`C-I L COMPLY <br />PLUMBING: FLORIDA BUILDING CODE, PLUMBING - 2007 (W/ 2009 AMENDMENTS) i' �AIL1l QDE TIIALL INCLUDES POURING A NEW SLAB IN THE AREA OF THE EXISTING SLAB LEAVEOUT AT THE REAR OF TENANT <br />MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL - 2007 (WI 2009 AMENDMENTS) CODE, ��ATIO NAT P 'r LORIDA EUILDI� G SPACE 68. <br />ELECTRICAL: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) (;TY`OF, E�r>.r „r ' CTR1C COLEAI T` <br />(CHAPTER 27 -NFPA 70, NATIONAL ELECTRIC CODE) Y`-� Ls C�I?L4?�L� 16. THE EXISTING BUILDING HAS A FIRE SPRINKLER SYSTEM WITH THE HEADS TURNED UP. THE SCOPE <br />FUEUGAS: FLORIDAC BUILDING CODE, FUEL/GAS - 2007 (W12009 AMENDMENTS) INCLUDES TURNING DOWN THE SPRINKLER HEADS AND MOVING THEM AS NEEDED TO FIT THE CEILING <br />ACCESSIBILITY: FLORIDA BUILDING CODE, BUILDING - 2007 (WI 2009 AMENDMENTS) LAYOUT. THE SCOPE INCLUDES DESIGN AND PERMITTING BY THE FIRE SPRINKLER SUBCONTRACTOR'S <br />(CHAPTER 11 - FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION). SPECIALTY ENGINEER THROUGH HIS SHOP DRAWINGS. <br />ENERGY: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) 17. THE SCOPE INCLUDES PROVIDING NEW SANITARY SERVICE, NEW VENT SYSTEM, AND NEW POTABLE <br />(CHAPTER 13 - FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION). WATER SERVICE FOR THE RESTROOM. <br />BUILDING AND CONSTRUCTION DATA 18. THE SCOPE DOES NOT INCLUDE ANY WORK TO ANY UNDERGROUND SANITARY LINES OTHER THAN WHAT <br />IS REQUIRED FOR CONNECTION OF THE NEW SANITARY LINES. THE SCOPE DOES NOT INCLUDE ANY <br />OCCUPANCY CLASSIFICATION (FBC 309) GROUP M -MERCANTILE "w i t= t ° ' I , �g f ACE E WORK TO ANY OF THE EXISTING CLEAN OUTS. <br />CONSTRUCTION TYPE (FBC TABLE 601) TYPE II-B, FULLY SPRINKLERED R - V ..' � �� <br />Pin I <br />MAXIMUM HEIGHT AND AREA (FBC TABLE 503) <br />MAXIMUM HEIGHT 55'-0" - FOUR STORIES .7') Q4 V , <br />ACTUAL HEIGHT 38'-6" - ONE STORY <br />MAXIMUM AREA 50,000 SF* 5! R c 1 CLP <br />� �j�tSi� � <br />ACTUAL AREAS 15,137 SF <br />* -THE MAXIMUM AREA ALLOWED BY TABLE 503 HAS BEEN INCREASED Please be advised 1€ r �' �, submi#ted is a <br />FROM 12,500 SF TO 50;000 SF AS ALLOWED BY FBC 506.1 & 506.3 cum" review to assisst .?. itai, crjmpliarce <br />applicable fire safety codes ;;" revievr is r2ot . Aef <br />t be f I I .k . ++- ' <br />NOTE: <br />WIND ZONE =110 MPH. IMPORTANCE FACTOR =1.00 <br />BLDG CATEGORY = II, ENCLOSED. WIND EXPOSURE = B <br />THE SCOPE OF WORK FOR THIS INTERIOR BUILD OUT DOES NOT INCLUDE ANY <br />MODIFICATIONS TO ANY EXTERIOR DOORS OR WINDOWS. ALL MODIFICATIONS <br />TO THE EXISTING ROOF SYSTEM SHALL BE PERFORMED IN ACCORDANCE WITH <br />THE MIAMI DADE NOTICE OF ACCEPTANCE (NOA). <br />Contact Information <br />o a ina approva o..� �a 5UV1 i 1_1"!U plo(Is. It rr, , <br />contractor's sole responsibility tRc-2nssure that the plat in <br />complete compliance with all applicable NFPA codas ,:. d SHEET NO. <br />lc,_ ordinances. In the event ihat further examis satib } or <br />.tioo reveals areas of non-compliance, it shall be <br />ti ' ,,i i tor's sole responsibility, at their sole expense to ARCHITECTURAL <br />a;= naj <br />those areas in compliance. The City assumes no <br />responsibility nor the failure to be in compliance <br />Wir' ,=s and local ordinances. <br />CLIENT: <br />PRIMERICA GROUP ONE, INC. <br />STRUCTURAL <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />3629 MADACA LANE <br />ENGINEER: <br />1925 PROSPECT AVE <br />TAMPA, FL. 33618 <br />ORLANDO, FL 32814 <br />(813) 933-0629 PHONE <br />(407) 661-9100 PHONE <br />(813) 935-3420 FAX <br />(407) 661-9101 FAX <br />CONTACT: LARRY GARREN <br />CONTACT: BRETT RYLANDS <br />ARCHITECT: <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />MECHANICAL <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />1925 PROSPECT AVE <br />ENGINEER: <br />1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />(407) 661-9101 FAX <br />CONTACT: GABRIEL ROBERTSON <br />CONTACT: JOE KEENE <br />CIVIL <br />AVID GROUP <br />ELECTRICAL <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />ENGINEER: <br />8659 BAYPINE ROAD, STE 304 <br />ENGINEER: <br />1925 PROSPECT AVE <br />JACKSONVILLE, FLORIDA 32256 <br />ORLANDO, FL 32814 <br />(904) 737-4001 PHONE <br />(407) 661-9100 PHONE <br />(904) 252-7030 FAX <br />(407) 661-9101 FAX <br />CONTACT: BOB PIERRO <br />CONTACT: TIM NASH <br />A000 <br />Al00 <br />A101 <br />Al02 <br />A103 <br />A001 <br />A002 <br />A003 <br />A004 <br />= oil <br />1__' <br />AREA OF INTERIOR 1 39'-4" TO INSIDE FACE OF CMU WALL <br />WORK FOR B8 £° APPROX. DISTANCE. VERIFY INFIELD <br />19. THE SCOPE INCLUDES REMOVAL OF ANY UNUSED PORTION OF -THE EXISTING ABOVE GROUND STUBS IN <br />FOR SPACE B8. <br />20. THE SCOPE DOES NOT INCLUDE ANY FLOOR DRAINS OR ANY STUB OUTS FOR FUTURE CONNECTION TO <br />THE SANITARY OR VENT SYSTEMS. <br />21. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE WATER METER, THE 2" COLD WATER MAIN, OR ANY OF <br />THE VALVES. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE 1" COLD WATER BRANCH LINE OTHER <br />THAN WHAT IS REQUIRED FOR CONNECTION OF THE NEW COLD WATER PIPING. <br />22. THE SCOPE DOES NOT INCLUDE ANY PROVISIONS FOR HOT WATER OR ANY STUB OUTS OR VALVES FOR <br />FUTURE CONNECTION TO THE COLD WATER SYSTEM. <br />23. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO GAS OR GREASE. <br />24. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE EXISTING 4 TON RTU ABOVE SPACE B8 OTHER THAN <br />WHAT IS REQUIRED TO CONNECT NEW HVAC DUCTING. THE SCOPE DOES NOT INCLUDE ANY WORK FOR <br />ANY OTHER RTUS OR ANY OF THE EXISTING CONDENSATE LINES. <br />25. THE SCOPE INCLUDES PROVIDING A FULL HVAC SYSTEM. <br />26. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE BUILDING TRANSFORMER, SECONDARY CONDUIT, <br />SECONDARY WIRE, MAIN DISCONNECT, WIREWAY, TENANT METER OR TENANT DISCONNECT. <br />27. THE SCOPE INCLUDES PROVIDING A NEW 200 AMP TENANT PANEL CONNECTED TO THE EXISTING <br />DISCONNECT VIA NEW WIRE PULLED THROUGH THE EXISTING EMPTY CONDUIT. <br />28. THE SCOPE INCLUDES PROVIDING NEW POWER RECEPTACLES WIRED TO THE TENANT PANEL. <br />29. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING SIGN JUNCTION BOX ON THE FRONT OF <br />THE BUILDING OTHER THAN WIRING IT TO THE TENANT PANEL. <br />30. THE SCOPE INCLUDES WIRING THE EXISTING RTU AND ALL OTHER COMPONENTS OF THE HVAC SYSTEM <br />TO THE TENANT PANEL. <br />31. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE SCONCE FIXTURES ON THE FRONT OF THE <br />BUILDING OR THEIR WIRING. <br />32. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING WALL MOUNTED LIGHT FIXTURE ON THE <br />REAR OF THE BUILDING OTHER THAN WIRING IT TO THE TENANT PANEL VIA A LIGHT SWITCH. <br />33. THE SCOPE INCLUDES PROVIDING NEW EXIT AND EMERGENCY LIGHTS. THESE LIGHTS SHALL BE WIRED <br />TO THE NEW TENANT PANEL. <br />34. THE SCOPE INCLUDES PROVIDING NEW 2' x 4' FLUORESCENT LIGHT FIXTURES WIRED TO THE TENANT <br />PANEL. <br />35. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING TELEPHONE SYSTEM. <br />36. THE EXISTING BUILDING HAS A FIRE ALARM SYSTEM. THE SCOPE INCLUDES MODIFYING THE SYSTEM AS <br />NEEDED FOR THE TENANT BUILD OUT. THE SCOPE INCLUDES DESIGN AND PERMITTING OF THE FIRE <br />ALARM SYSTEM BY THE CONTRACTOR THROUGH SHOP DRAWINGS. <br />Drawing Index <br />TITLE ON SHEET PERMIT SET <br />2010_01-25 <br />----------- <br />z <br />p� <br />M <br />J <br />mM <br />Q� <br />w <br />w �` <br />m <br />00 <br />U O <br />03 <br />0 <br />O � <br />cis <br />� MM <br />rMwol <br />FIRE PROTECTION <br />FIRE PROTECTION NOTE - THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED. THE SPRINKLER SYSTEM SHALL BE MODIFIED AS NEEDED FOR SPACE B8. ALL MODIFICATIONS TO THE SPRINKLER SYSTEM SHALL BE <br />DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />PLUMBING I <br />P101 PLUMBING GENERAL INFORMATION FLOOR PLAN & RISERS X <br />MECHANICAL <br />M101 MECHANICAL GENERAL INFORMATION & FLOOR PLAN X /►�1 <br />ELECTRICAL <br />E101 <br />E501 <br />COVER SHEET <br />X <br />PROJECT SITE PLAN <br />X <br />SPACE B8 PLANS <br />X <br />SPACE B8 DETAILS <br />X <br />SPACE B8 DETAILS <br />X <br />B8 SPECIFICATIONS <br />X <br />B8 SPECIFICATIONS <br />X <br />B8 SPECIFICATIONS <br />X <br />B8 SPECIFICATIONS <br />X <br />X <br />X v <br />FIRE ALARM NOTE - THE EXISTING SHELL BUILDING HAS A FULL FIRE ALARM SYSTEM. THE FIRE ALARM SYSTEM SHALL BE MODIFIED AS NEEDED FOR SPACE B8. ALL MODIFICATIONS TO THE FIRE ALARM <br />SYSTEM SHALL BE DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />