Laserfiche WebLink
THE PORTION OF THE EXISTING REAR CMU WALL THAT <br />SEPARATES THE FIRE RISER ROOM FROM THE INTERIOR <br />OF THE SPACE HAS A 2 HR FIRE RATING. ALL WORK <br />RELATED TO THIS PORTION OF THE REAR WALL SHALL <br />BE PERFORMED SO AS TO MAINTAIN THE WALL'S EXISTING <br />FIRE RATING. —\ <br />EXISTING <br />FIRE RISER <br />ROOM <br />EXISTING 36" REAR — <br />DOOR (33' CLEAR <br />WHEN DOOR IS OPEN) <br />EGRESS CAPACITY <br />=165 PEOPLE <br />EXISTING <br />DOWNSPOUT <br />TO REMAIN AS IS <br />EXISTING — ----- <br />TELEPHONE <br />CONDUIT STUB IN <br />TO REMAIN AS IS <br />NEW ELEC. <br />PANEL. RE: E101 <br />EXISTING 3' X T HM <br />DOOR (TYPE B) TO <br />REMAIN AS IS <br />EXISTING REAR — <br />CONCR. SIDEWALK <br />TO REMAIN AS IS <br />TENANT DEMISING WALL EMERGENCY LIGHT EXIT LIGHT <br />MIN 1 HR FIRE RATING <br />RE: UL DETAILS, U419 <br />o.0.00,�b <br />idO <br />a <br />/ice <br />� /ice <br />o <br />0 <br />o <br />I /ice <br />i .o <br />PATH OF EGRESS <br />MAX EXIT DISTANCE = 35' — � <br />o� <br />.� <br />' aoso r <br />EXIT LIGHT Woo <br />0000 <br />FIRE EXTINGUISHER EMERGENCY LIGHT TENANT DEMISING WALL <br />MIN 1 HR FIRE RATING <br />RE: UL DETAILS, U419 <br />1200 SF MERCANTILE SPACE I I I <br />n <br />OCCUPANT LOAD = 40 PEOPLE <br />�I <br />i <br />� V- <br />I B-H + B-G\+ I B-D 4 B-C i <br />N Life Safety Plan <br />SCALE: 1/8" =1'-0" <br />60'-0" LEASABLE <br />OUTSIDE FACE OF WALL TO OUTSIDE FACE OF WALL <br />58'-9%" INTERIOR CLEAR <br />INSIDE FACE OF FRONT WALL FINISH TO INSIDE FACE OF REAR CMU <br />(OUTSIDE OF RESTRWM) <br />EXISTING TX 7' <br />NEW RESTROOM <br />NEW 6" DEMISING <br />HM DOOR <br />REFER TO GENERAL <br />WALL. RE: GENERAL <br />(TYPE B) TO <br />NOTE # 3 & 4 <br />NOTE 1 <br />REMAIN AS IS <br />B <br />I <br />A C <br />I <br />D l HOLLOW CORE DOOR. <br />(TYPE C) RE: GENERAL <br />NOTE 5 & Al02 <br />I <br />I <br />EDGE OF EXISTING <br />M I SLAB LEAVE OUT <br />I <br />FILL IN EXISTING SLAB LEAVE <br />OUT IN REAR OF SPACE <br />I <br />NO FINISHES ADDED TO THE EXISTING <br />REAR WALL OUTSIDE OF THE RESTROOM <br />AREA OF EXISTING SLAB <br />LEAVE OUT TO REMAIN <br />! <br />! <br />! <br />+B-Hi <br />N 2 Floor Plan <br />SCALE: 1/8" =1'-0" <br />EXISTING RAIN <br />HOODS OVER REAR <br />DOORS TO REMAIN <br />AS THEYARE <br />C <br />NEW EXIT LIGHT <br />FIXTURE. RE: E101 <br />EXISTING SCONCE <br />LIGHT FIXTURE <br />TO REMAIN AS IS <br />NEW EXHAUST EXISTING 4 TON RTU ABOVE - <br />FAN. RE: M101 TO BE WIRED AND DUCTED. <br />RE: MECH & ELEC PLANS <br />NEW 2' X 4' ACOUSTICAL TILE <br />CEILINGS MOUNTED AT 10'-0" <br />ABOVE FLOORS IN RESTROOM <br />AND IN MAIN ROOM <br />I <br />I <br />I <br />II <br />+ B-H i <br />N 3 Reflected Ceiling Plan <br />SCALE: 1/8 =1-0 <br />I <br />I <br />I <br />I <br />+ B-G + <br />NEW SUPPLYAIR <br />DIFFUSER. RE: M101 <br />Code Information <br />JURISDICTION AUTHORITY <br />CITY OF ZEPHYRHILLS 3 SIGNED & SEALED SETS FOR PERMIT <br />5335 8TH STREET (813) 780-0020 - PHONE <br />ZEPHYRHILLS, FL 33542 (813) 780-0021- FAX <br />iADOPTED CODES: <br />1 '1 ALL PENETRATIONS IN FIRE RATED BUILDING: FLORIDA BUILDING CODE, BUILDING 2007 (W/ 2009 AMENDMENTS) <br />ud ik k 11 WALL H S SHALL BE SEALED SO AS FIRE: FLORIDA FIRE PREVENTION CODE - 2007 (W/ 2009 AMENDMENTS) <br />TO MAINTAIN THE MIN. REQUIRED (CHAPTER 36 - NFPA 1 & NFPA 101 W/ STATE FIRE MARSHAL AMENDMENTS) <br />FIRE RATING. RE: UL DETAILS PLUMBING: FLORIDA BUILDING CODE, PLUMBING - 2007 (W/ 2009 AMENDMENTS) <br />MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL - 2007 / 2009AMENDMENTS) <br />IIIIIIIII...... 11, <br />- B �� ELECTRICAL: FLORIDA BUILDING CODE BUILDING - 2007 / 2009 AMENDMENTS <br />. <br />(CHAPTER 27 - NFPA 70, NATIONAL ELECTRIC CODE) ) <br />THE EXISTING DOOR HARDWARE <br />FUEUGAS: FLORIDA BUILDING CODE F UGAS 2007 W/ 2009 AMENDMENTS) <br />) <br />ON THE EXISTING FRONT AND REAR <br />ACCESSIBILITY: FLORIDA BUILDINGDE BUILDING - 2 7 CO 00 / 2009 AMENDMENTS <br />DOORS MEETS ADA REQUIREMENTS (CHAPTER 11 - FLORIDAACCESSIBILITY CODE FOR BUILDING CONSTRUCTION). <br />ENERGY: FLORIDA BUILDING CODE, BUILDING - 2007 (WI 2009 AMENDMENTS) <br />(CHAPTER 13 - FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION). <br />EXISTING 36" FRONT DOOR <br />(33" CLEAR WHEN DOOR IS OPEN) <br />EGRESS CAPACITY =165 PEOPLE BUILDING AND CONSTRUCTION DATA <br />OCCUPANCY CLASSIFICATION (FBC 309) GROUP M - MERCANTILE <br />CONSTRUCTION TYPE (FBC TABLE 601) TYPE II-B, FULLY SPRINKLERED <br />EXISTING FRONT FRAMED WALL <br />HAS A 1 HOUR FIRE RATING. ALL <br />!! i,li;! WORK RELATED TO THE FRONT MAXIMUM HEIGHT AND AREA (FBC TABLE 503 <br />I!i!i!IIIi; (sill.; WALL SHALL BE PERFORMED SO ( ) <br />— - - - - B-12 i AS TO MAINTAIN THE WALLS <br />HEIGHT 55'-0" FOUR STORIES <br />(Iiillll;'!,p ,�NIiIIII�!ul; ` EXISTING FIRE RATING. ACTUAL HEIGHT 38'-6" -ONE STORY <br />�I'I'iri <br />,'I! ! MAXIMUM AREA 50,000 SF' <br />ACTUALAREAS 15,137 SF <br />��Iplyli� '4� <br />THE MAXIMUM AREAALLOWED BY TABLE 503 HAS BEEN INCREASED <br />'iPh!I FROM 12,500 SF TO 50,000 SF AS ALLOWED BY FBC 506.1 & 506.3 <br />FLOOR PLAN GENERAL NOTES: <br />1. NEW 6" DEMISING WALLS SHALL HAVE 5/8" SHEATHING BOTH SIDES <br />AND R19 BATT INSULATION. FRAMING, SHEATHING, AND INSULATION <br />SHALL EXTEND TO THE UNDERSIDE OF THE ROOF DECKABOVE. NEW <br />6" DEMISING WALLS SHALL PROVIDE A MIN. 1 HOUR FIRE RATING. <br />SHEATHING SHALL BE PAINT READY. <br />2. EXISTING STRUCTURAL COMPONENTS OF REAR CMU WALL TO REMAIN <br />AS IS. ON THE INTERIOR SIDE OF THE WALL, INSIDE THE RESTROOM <br />ONLY, 1/2" MOISTURE RESISTANT GYP BOARD SHALL BE ADDED OVER <br />1.5" FURRING STRIPS @ 24" OC AND 1.5" RIGID INSULATION. FURRING, <br />GYP BOARD, AND INSULATION SHALL TERMINATE 10'4" AFF. THE GYP <br />BOARD SHALL RECEIVE ENAMEL PAINT. THE REST OF THE REAR CMU <br />WALL SHALL REMAIN UNPAINTED WITH NO FINISH ADDED. <br />3. NEW RESTROOM WALLS SHALL BE EITHER 6' OR 3-5/8" FRAMING AS <br />SHOWN. 6" WALLS SHALL RECEIVE R19 BATT INSULATION. 3-518" <br />WALLS SHALL RECEIVE R11 BATT INSULATION. ALL WALLS SHALL <br />HAVE 1/2" PAINT READY GYP BOARD ON THE OUTSIDE. ALL WALLS <br />SHALL HAVE 1/2" MOISTURE RESISTANT GYP BOARD WITH ENAMEL <br />PAINT ON THE INSIDE. ALL FRAMING, SHEATHING, AND INSULATION <br />SHALLTERMINATE 10'-6"AFF. THE RESTROOM SHALL HAVE VCT <br />FLOORING AND A 6" VINYL BASE ON THE INSIDE OF ALL WALLS. <br />4. BATHROOM ACCESSORIES SHALL INCLUDE TOILET PAPER DISPENSER, <br />PAPER TOWEL DISPENSER, SOAP DISPENSER, MIRROR, AND GRAB <br />BARS AS REQUIRED BY CODE. ALL ACCESSORIES SHALL BE ADA <br />COMPLIANTAND SHALL BE STAINLESS STEEL. <br />5. BATHROOM DOOR SHALL BE A 1-3/4" X 36" X 80" PRE -HUNG HOLLOW <br />CORE DOOR. THE EXTERIOR SHALL BE PAINT READY THE INTERIOR <br />SHALL RECEIVE ENAMEL PAINT. THE HARDWARE SET SHALL INCLUDE 3 <br />HINGES, 3 SILENCERS,1 WALL STOP,1 CLOSER, AND 1 "PRIVACY LOCK" <br />LOCKSET THE DOOR SHALLALSO RECEIVE ADAACCESSIBLE SIGNAGE <br />AS REQUIRED BY CODE. <br />6. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. <br />7. COLORS FOR ALL PAINT, ACT, VCT & VINYL BASE SHALL BE SELECTED <br />BY THE OWNER FROM SAMPLES PROVIDED BY THE CONTRACTOR. <br />CEILING PLAN GENERAL NOTES: <br />1. ALL NEW CEILINGS SHALL BE 2' X 4' ACT MOUNTED <br />AT 10'-0" AFF WITH NO INSULATION. <br />2. ON THE FRONT OF THE BUILDING, THE EXISTING <br />DECORATIVE SCONCE FIXTURES SHALL REMAIN WIRED <br />AS IS TO THE EXISTING HOUSE PANEL. <br />3. EXISTING REAR WALL MOUNTED LIGHT SHALL BE WIRED <br />TO THE NEW TENANT PANEL VIAA NEW LIGHT SWITCH. <br />4. ALL NEW EXIT LIGHTS, EMERGENCY LIGHTS, AND 2 X 4 <br />FLUORESCENT LIGHTS SHALL BE WIRED TO THE NEW <br />TENANT PANEL. <br />5. THE 4 TON RTU IS EXISTING AND SHALL REMAIN. ALL NEW <br />SUPPLY DIFFUSERS, RETURN GRILLES, AND EXHAUST FANS <br />SHALL BE TIED INTO THE EXISTING RTU VIA NEW DUCTWORK. <br />6. THE EXISTING RTU AND THE NEW EXHAUST FAN SHALL <br />BE WIRED TO THE NEW TENANT PANEL. <br />7. THE LOCATIONS OF THE FIRE SPRINKLER HEADS SHALL BE <br />DETERMINED BY THE FIRE SPRINKLER SUBCONTRACTOR'S <br />SPECIALTY ENGINEER DURING THE DESIGN OF HIS / HER <br />SHOP DRAWINGS. THE CONTRACTOR SHALL COORDINATE <br />THE HEAD LOCATIONS WITH ALL OTHER DISCIPLINES TO <br />AVOID ANY CONFLICTS. <br />SECTION <br />EXISTING MASONRY <br />WALL TO REMAIN AS <br />EXISTING COREFILL <br />FOAM INSULATION T, <br />REMAIN AS IS <br />EXISTING EXTERI( <br />FINISHES TO REM, <br />AS THEYARE <br />EXISTING EXTERI( <br />SIDEWALKS AND <br />ADJACENT LANDS <br />AREAS TO REMAII <br />AS THEYARE <br />PLAN VIEW <br />SECTION <br />FIRE RATING REQUIREMENTS <br />FBC TABLES 601 & 602 - FIRE RATING REQUIREMENTS FOR CONSTRUCTION TYPE II-B <br />ELEMENT <br />REQUIRED FIRE RATING <br />STRUCTURALFRAME <br />0HR <br />LOAD BEARING EXTERIOR WALLS <br />2 HR <br />(F.S.D. < 6) <br />LOAD BEARING EXTERIOR WALLS <br />1 HR <br />PROVIDED AS <br />(F.S.D. BETWEEN 5' & 10-) <br />PART OF SHELL <br />LOAD BEARING EXTERIOR WALLS <br />0 HR <br />(F.S.D. > 10') <br />ROOF CONSTRUCTION <br />0 HR <br />FLOOR CONSTRUCTION <br />0 HR <br />NON BEARING INTERIOR WALLS <br />0 HR <br />F.S.D. IS FIRE SEPARATION DISTANCE <br />FBC 708 - OTHER FIRE RATING REQUIREMENTS <br />TENANTS SHALL BE SEPARATED BY MIN 1 HR FIRE BARRIER <br />FBC 803 - CLASSIFICATION OF INTERIOR FINISHES <br />FBC 803.1 - FLAMESPREAD <br />A-FLAMESPREAD 0-25, SMOKE DEV. 0-450 <br />CLASSIFICATIONS <br />B-FLAMESPREAD 26-75, SMOKE DEV. 0-450 <br />C-FLAMESPREAD 76-200, SMOKE DEV. 0-450 <br />TABLE 803.5 - REQUIRED <br />EXIT PASSAGEWAYS - CLASS B <br />FLAMESPREAD FOR MERCANTILE <br />EXIT ACCESS CORRIDORS - CLASS C <br />OCCUPANCY (SPRINKLERED) <br />ROOMS & OTHER SPACES - CLASS C <br />FIRE PROTECTION SYSTEMS, FBC 900 <br />FBC 903 - SPRINKLERS <br />DESIGN STANDARD NFPA 13 AS <br />MODIFIED BY NFPA 231 & NFPA 231 C <br />FBC 903.2.6 - GROUP M REQUIREMENTS <br />FIRE SPRINKLERS REQUIRED IN GROUP <br />M WHEN GROSS AREA > 12,000 SF <br />(REQUIRED, PROVIDED) <br />FBC 906 - PORTABLE FIRE EXTINGUISHERS <br />EACH TENANT SPACE IS PROVIDED WITH <br />A PORTABLE FIRE EXTINGUISHER <br />FBC 907.2.7 - FIRE ALARMS <br />FIRE ALARMS REQUIRED IN GROUP M <br />WHEN OCCUPANT LOAD > 500 <br />(REQUIRED, PROVIDED) <br />Existing Masonry Wall <br />EXISTING MASO Y WALL WITH FRAM G AND <br />SHEATHING ADDED TO THE INTERIOR SIDE. <br />TO BE USED ALONG THE REAR WALL INSIDE OF THE RESTROOM <br />SCALE: 1 1/2" =1'-0" <br />1/2" GYP BOARD BOTH <br />SIDES OF FRAMING. <br />FRAMING, SHEATI <br />& INSULATION TO <br />TERMINATE 6"ABI <br />CEILING. <br />PLAN VIEW <br />New 6" Metal Stud Wall <br />NO FIRE RATING <br />TO BE USED FOR RESTROOM WET WALL. <br />SCALE: 1 1/2" = 1'-0" <br />1 1/2' RIGID <br />INSULATION <br />FURRING, SHEATHING, <br />& INSULATION TO RUN <br />FROM FLOOR SLAB <br />TO 6" ABOVE CEILING <br />SUSPENDED CEILING <br />RE: CEILING PLAN <br />1/2" GYP BOARD OVER <br />1 1/2" Z-FURRING <br />CHANNELS @ 24" OC <br />MAX SPACING <br />6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY <br />NEW CONCRETE <br />FLOOR SLAB IN <br />AREA OF EXISTING <br />SLAB LEAVE OUT <br />CONTINUOUS STUD AT <br />TOP OF WALL <br />MTL STUD FRAMING <br />600S125-43 @ 24' OC <br />LAY -IN CEILING, RE: RCP <br />R-19 SOUND BATTS <br />CONTINUOUS STUD TRACK <br />60OT125-43 <br />6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY <br />EXISTING CONCRETE <br />FLOOR SLAB TO <br />REMAIN AS IS <br />SECTION <br />THIS BUILDING HAS A FULL FIRE SPRINKLER SYSTEM. THE CONTRACTOR SHALL <br />PREPARE SHOP DRAWINGS FOR REVISIONS TO THE SYSTEM AS NEEDED FOR THE <br />BUILDOUT OF THE SPACE. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED <br />SHOP DRAWINGS TO THE LOCAL JURISDICTION AS REQUIRED FOR PERMITTING. <br />THIS BUILDING HAS A FULL FIRE ALARM SYSTEM. THE CONTRACTOR SHALL <br />PREPARE SHOP DRAWINGS FOR REVISIONS TO THE SYSTEM AS NEEDED FOR THE <br />BUILDOUT OF THE SPACE. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED <br />SHOP DRAWINGS TO THE LOCAL JURISDICTION AS REQUIRED FOR PERMITTING. <br />MEANS OF EGRESS, FBC 1000 <br />OCCUPANCY CLASSIFICATION MERCANTILE (SPRINKLERED) <br />FLOOR AREAS AT GRADE <br />FBC 1004.1.1 - OCCUPANT LOAD 1 PERSON / 30 SF (GROSS) <br />FBC 1005.1-EGRESS WIDTH /PERSON .2 0 / PERSON <br />FBC 1008.1.1-MIN. CLEAR DOOR OPENING 2 MIN <br />0 G 3 <br />FBC 1016.1 - MAX. TRAVEL DISTANCE 250' MAX <br />FBC 1019.1 - MIN. NUMBER OF EXITS 2 WHEN OCCUPANT LOAD 1-500 <br />EGRESS WIDTH # OF EXITS <br />TENANT GROUP SIZE (SF) OCCUR LOAD (REQ'D / PROV'D) (REQ'D / PROV'D) <br />B8 M 1,200 1/30 40 8.0" / 66" 2/2 <br />FBC PLUMBING 403 - MINIMUM FACILITIES <br />OCCUPANCY - MERCANTILE (1 PERSON PER 30 SF GROSS) <br />PFBC TABLE 403.1 - # OF FIXTURES REQUIRED PER PERSON <br />MEN'S WATER CLOSETS 1 / 500 BATHTUB / SHOWER NOT REQUIRED <br />WOMEN'S WATER CLOSETS 1 / 500 DRINKING FOUNTAINS 1 / 1,000 <br />LAVATORIES 1 / 750 SERVICE SINK NOT REQUIRED <br />PFBC 403.2.4 - SEPARATE FACILITIES NOT REQUIRED IN GROUP M WHEN <br />FLOOR AREA < 3000 SQ. FT. <br />SPACE SIZE (SF) LOAD FIXTURES (REQUIRED I PROVIDED) <br />WC LAV DF <br />B8 1,200 40 1/ 1 1/ 1 1/2 <br />I <br />5/8" GYP BOARD BOTH <br />SIDES OF FRAMING. <br />FRAMING, SHEATHING, <br />& INSULATION TO <br />TERMINATE AT UNDERSIDE <br />OF ROOF STRUCTURE ABOVE. T� <br />WALL CONSTRUCTION SHALL <br />BE CONSISTENT WITH UL <br />DETAILS U419, HW-S-0001, & <br />W-L-1001 TO PROVIDE A MIN. <br />1 HOUR FIRE RATING. <br />lull-_. <br />PLAN VIEW <br />New 6" Metal Stud Wall <br />1 HOUR FIRE RATING <br />TO BE USED FOR BOTH TENANT DEMISING WALLS <br />SCALE: 1 1/2" = 1'-0' <br />SECTION <br />1/2" GYP BOARD BOTH <br />SIDES OF FRAMING. <br />FRAMING, SHEATh""" <br />& INSULATION TO <br />TERMINATE 6"AB( <br />CEILING. <br />PLAN VIEW <br />New 3 5/8" Metal Stud Wall <br />NO FIRE RATING <br />TO BE USED FOR THE RESTROOM NON -WET WALLS <br />SCALE: 1 1/2" =1'-0" <br />EXISTING ROOF DECK <br />CONTINUOUS STUD AT <br />TOP OF WALL <br />MTL STUD FRAMING <br />600S125-43 @ 24" OC <br />R-19 SOUND BATTS <br />CONTINUOUS STUD <br />TRACK 60OT12543 <br />6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY <br />EXISTING CONCRETE <br />FLOOR SLAB TO <br />REMAIN AS IS <br />CONTINUOUS STUD AT <br />TOP OF WALL <br />MTL STUD FRAMING <br />362S125-43 @ 24" OC <br />LAY -IN CEILING, RE: RCP <br />R-11 SOUND BATTS <br />CONTINUOUS STUD TRACK <br />362T125-43 <br />6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY <br />EXISTING CONCRETE <br />FLOOR SLAB TO <br />REMAIN AS IS <br />N <br />o � <br />O <br />V1 <br />� <br />M O <br />^11 <br />U <br />� <br />a <br />w <br />�rn <br />3 <br />U <br />U <br />0 <br />0 <br />AIL <br />`/ W <br />MZ00 <br />J <br />W�L�L <br />"E�a <br />L <br />w oa <br />J <br />U <br />0 <br />E <br />E <br />0 <br />U <br />L <br />C_ <br />Nm <br />CU Q <br />_j <br />m <br />M0 <br />W <br />�Q <br />45 Ui <br />♦♦/^ <br />Cn <br />Lu <br />= J = <br />Q <br />ICU >- <br />0 <br />U <br />N d <br />�tiN <br />0 <br />a <br />Cn <br />_C <br />C !} <br />I� A <br />w 0 <br />ICU <br />F- Q <br />w /1 r <br />w VJ = <br />x <br />co <br />co <br />z <br />j o <br />J <br />m ., <br />Z Q;_ <br />� U- <br />W V- <br />w <br />CD <br />w <br />a <br />VV <br />0 <br />w <br />o <br />Q <br />o <br />W <br />N <br />J <br />w <br />Q <br />Zrnl <br />o <br />M <br />O <br />L <br />� <br />w <br />Z <br />m _ <br />N <br />w <br />N <br />U <br />LU <br />a <br />o <br />v <br />A101 <br />