UM.. a
<br />List Of Abbreviations
<br />ip
<br />A
<br />A/C
<br />AIR CONDITION
<br />E
<br />EL
<br />ELEVATION
<br />L
<br />LAV
<br />LAVATORY
<br />S
<br />SC
<br />SOLID CORE
<br />AB
<br />ANCHOR BOLT
<br />ELEC
<br />ELECTRICAL
<br />LBL
<br />LABEL
<br />SCHED
<br />SCHEDULE
<br />ACT
<br />ACOUSTICAL CEILING TILE
<br />ELEV
<br />ELEVATOR
<br />LBS
<br />POUNDS
<br />SCP
<br />SCUPPER
<br />AD
<br />ADJUSTABLE, ADJACENT
<br />EMER
<br />EMERGENCY
<br />LF
<br />LINEAR FEET
<br />SD
<br />SOAP DISPENSER
<br />AFF
<br />ABOVE REF FINISHED
<br />EQ
<br />EQUAL
<br />LT WT
<br />LIGHT WEIGHT
<br />SEAL
<br />SEALANT
<br />FLOOR (SLAB)
<br />EQUIP
<br />EQUIPMENT
<br />SECT
<br />SECTION
<br />AHU
<br />AIR HANDLER UNIT
<br />ESC
<br />ESCALATOR
<br />M
<br />MAS
<br />MASONRY
<br />SF
<br />SQUARE FEET
<br />ALT
<br />ALTERNATE
<br />EWC
<br />ELECTRIC
<br />MAX
<br />MAXIMUM
<br />SHT
<br />SHEET
<br />ALUM
<br />ALUMINUM
<br />WATER COOLER
<br />MECH
<br />MECHANICAL
<br />SIM
<br />SIMILAR
<br />ANOD
<br />ANODIZED
<br />EXIST
<br />EXISTING
<br />MFR
<br />MANUFACTURER
<br />SPEC
<br />SPECIFICATION
<br />APPROX APPROXIMATE
<br />EXP
<br />EXPANSION
<br />MH
<br />MANHOLE
<br />SS
<br />STAINLESS STEEL,
<br />ARCH
<br />ARCHITECT
<br />EXT
<br />EXTERIOR
<br />MIN
<br />MINIMUM
<br />SERVICE SINK
<br />AUTO
<br />AUTOMATIC
<br />MIN
<br />MINIMUM, MINUTE
<br />STD
<br />STANDARD
<br />F
<br />FACP
<br />FIRE ALARM
<br />MISC
<br />MISCELLANEOUS
<br />STL
<br />STEEL
<br />B
<br />B 0
<br />BOTTOM OF
<br />CONTROL PANEL
<br />MLDG
<br />MOLDING
<br />STOR
<br />STORAGE
<br />BD
<br />BOARD
<br />FD
<br />FLOOR DRAIN
<br />MO
<br />MASONRY OPENING
<br />STRUC
<br />STRUCTURAL
<br />BLDG
<br />BUILDING
<br />FDN
<br />FOUNDATION
<br />MR
<br />MOISTURE RESISTANT
<br />SUSP
<br />SUSPENDED
<br />BM
<br />BEAM
<br />FIN
<br />FINISHED
<br />MTD
<br />MOUNTED
<br />SY
<br />SQUARE YARD
<br />BRG
<br />BEARING
<br />FLR
<br />FLOOR
<br />MTL
<br />METAL
<br />BTM
<br />BOTTOM
<br />FR
<br />FIRE RESISTANT
<br />MUL
<br />MULLION
<br />T
<br />T
<br />TREAD
<br />BUR
<br />BUILT UP ROOF
<br />FR-S
<br />FIRE -RETARDANT
<br />T&G
<br />TONGUE & GROOVE
<br />WOOD TREATMENT
<br />N
<br />NIC
<br />NOT IN CONTRACT
<br />TBL
<br />TABLE
<br />C
<br />CB
<br />CATCH BASIN
<br />FT
<br />FEET, FOOT
<br />NOM
<br />NOMINAL
<br />TELE
<br />TELEPHONE
<br />CG
<br />CORNER GUARD
<br />FTG
<br />FOOTING
<br />NTS
<br />NOT TO SCALE
<br />TEMP
<br />TEMPERED
<br />Cl
<br />CAST IRON
<br />FURR
<br />FURRING
<br />THK
<br />THICK
<br />CJ
<br />CONTROL JOINT
<br />FUT
<br />FUTURE
<br />0
<br />OC
<br />ON CENTER
<br />TLT
<br />TOILET
<br />CL
<br />CENTER LINE
<br />OD
<br />OUTSIDE DIAMETER
<br />TO
<br />TOP OF
<br />CLG
<br />CEILING
<br />G
<br />GA
<br />GAUGE
<br />OPP
<br />OPPOSITE
<br />TPD
<br />TOILET PAPER
<br />CLO
<br />CLOSET
<br />GAL
<br />GALLON
<br />OVFL
<br />OVERFLOW
<br />DISPENSER
<br />CLR
<br />CLEAR
<br />GALV
<br />GALVANIZED
<br />TS
<br />TUBE STEEL
<br />CMU
<br />CONCRETE
<br />GB
<br />GRAB BAR
<br />P
<br />PL
<br />PLATE
<br />TV
<br />TELEVISION
<br />MASONRY UNIT
<br />GC
<br />GENERAL CONTRACTOR
<br />PIAM
<br />PLASTIC LAMINATE
<br />TYP
<br />TYPICAL
<br />CO
<br />CLEAN OUT
<br />GYP
<br />GYPSUM
<br />PIAS
<br />PLASTER
<br />COL
<br />COLUMN
<br />PLBG
<br />PLUMBING
<br />U
<br />LION
<br />UNLESS OTHER-
<br />CONC
<br />CONCRETE
<br />H
<br />HB
<br />HOSE BIBB
<br />PLWD
<br />PLYWOOD
<br />WISE NOTED
<br />CONST
<br />CONSTRUCTION
<br />HC
<br />HOLLOW CORE
<br />PNL
<br />PANEL
<br />UTIL
<br />UTILITY
<br />CONT
<br />CONTINUOUS
<br />HDW
<br />HARDWARE
<br />PR
<br />PAIR
<br />CONTR
<br />CONTRACTOR
<br />HM
<br />HOLLOW METAL
<br />PREFAB
<br />PREFABRICATED
<br />V
<br />VB
<br />VINYL BASE
<br />CORR
<br />CORRIDOR
<br />HORIZ
<br />HORIZONTAL
<br />PT
<br />POINT
<br />VCT
<br />VINYL COMPOSITE TILE
<br />CT
<br />CERAMIC TILE
<br />HR
<br />HOUR
<br />PT
<br />PRESSURE TREATED
<br />VERT
<br />VERTICAL
<br />CTR
<br />CENTER
<br />HT
<br />HEIGHT
<br />PTD
<br />PAPER TOWEL DISPENSER
<br />VEST
<br />VESTIBULE
<br />CU
<br />CONDENSING UNIT
<br />HTG
<br />HEATING
<br />PVC
<br />POLY VINYL CLORIDE
<br />VIF
<br />VERIFY IN FIELD
<br />CW
<br />COLD WATER
<br />HVAC
<br />HEATING, VENTILATING
<br />VTR
<br />VENT THRU ROOF
<br />& AIR CONDITIONING
<br />Q
<br />QT
<br />QUARRY TILE
<br />VWC
<br />VINYL WALL COVERING
<br />D
<br />DBL
<br />DOUBLE
<br />HW
<br />HOT WATER
<br />DEPT
<br />DEPARTMENT
<br />R
<br />R
<br />RADIUS, RISER,
<br />W
<br />W
<br />WIDTH
<br />DET
<br />DETAIL
<br />I
<br />ID
<br />INSIDE DIAMETER
<br />THERMAL RESISTANCE
<br />W/
<br />WITH
<br />DF
<br />DRINKING FOUNTAIN
<br />IN
<br />INCH
<br />RD
<br />ROOF DRAIN
<br />W/O
<br />WITHOUT
<br />DIA
<br />DIAMETER
<br />INCL
<br />INCLUDING
<br />RECP
<br />RECEPTACLE
<br />WC
<br />WATER CLOSET
<br />DIM
<br />DIMENSION
<br />INSUL
<br />INSULATION
<br />REF
<br />REFERENCE
<br />WD
<br />WOOD
<br />DISP
<br />DISPENSER
<br />INT
<br />INTERIOR
<br />REFR
<br />REFRIGERATOR
<br />WH
<br />WATER HEATER
<br />DN
<br />DOWN
<br />INV
<br />INVERT
<br />REG
<br />REGLET
<br />WP
<br />WATERPROOF
<br />DS
<br />DOWNSPOUT
<br />REINF
<br />REINFORCEMENT
<br />WT
<br />WEIGHT
<br />DWG
<br />DRAWING
<br />J
<br />JAN
<br />JANITOR
<br />REQ
<br />REQUIRED
<br />WWF
<br />WELDED WIRE FABRIC
<br />E
<br />JB
<br />JUNCTION BOX
<br />REV
<br />REVISION
<br />WWM
<br />WELDED WIRE METAL
<br />EA
<br />EACH
<br />JT
<br />JOINT
<br />RM
<br />ROOM
<br />EB
<br />EXPANSION BOLT
<br />RND
<br />ROUND
<br />Y
<br />YD
<br />YARD
<br />EIFS
<br />EXTERIOR INSULATING
<br />L
<br />L
<br />LENGTH
<br />RO
<br />ROUGH OPENING
<br />FINISH SYSTEM
<br />LAM
<br />LAMINATE
<br />RTU
<br />ROOF TOP UNIT
<br />EJ
<br />EXPANSION JOINT
<br />Legend
<br />&__GRID DESIGNATION
<br />F10-21 ROOM NUMBER
<br />102A DOOR NUMBER
<br />® WINDOW TYPE
<br />2O STOREFRONT TYPE
<br />L° f WALL TYPE
<br />0 KEY NOTE
<br />© REVISION NUMBER
<br />TO SOMETHING ELEVATIONS TAGS
<br />XX'-XX"
<br />SPOT ELEVATION TAG
<br />•
<br />N NORTH ARROW
<br />A BUILDING SECTION
<br />A301-2 A301-2
<br />SHEET NUMBER SECTION NUMBER
<br />I WALL SECTION
<br />A30�2�
<br />SHEET NUMBER SECTION NUMBER
<br />A501-6 SECTION DETAIL
<br />SHEET NUMBER DETAIL NUMBER
<br />A888-88 DETAIL REFERENCE
<br />SHEET NUMBER DETAIL NUMBER
<br />EXTERIOR ELEVATION
<br />A201-2 MARKERS
<br />SHEET NUMBER ELEVATION NUMBER
<br />1
<br />4 A401 2 INTERIOR ELEVATION
<br />MARKERS
<br />SHEET NUMBER 3 ELEVATION NUMBER
<br />'BRICK
<br />CONPLYWOOD
<br />GYPSUM
<br />BOARD
<br />: ••�•�;1
<br />DRAINAGE
<br />FILL
<br />MASONRY
<br />COMPACTED
<br />EARTH
<br />STEEL
<br />INSULATION
<br />...... ...
<br />BOARD
<br />General Notes
<br />1. ALL WORK WILL COMPLY WITH LOCAL, STATE, AND NATIONAL CODES
<br />RELATED TO THIS PROJECT.
<br />2. THE WRITTEN DIMENSIONS PREVAIL ON THE CONSTRUCTION DOCUMENTS,
<br />DO NOT SCALE THESE DRAWINGS. CONTRACTOR TO FIELD VERIFY ALL
<br />DIMENSIONS AND CONDITIONS. IF ANY DISCREPANCY OCCURS, THE
<br />CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING BEFORE
<br />PROCEEDING WITH ANY WORK AFFECTED BY THE DISCREPANCY.
<br />3. CONTRACTORS TO SECURE ALL PERMITS AND REQUIRED INSPECTIONS
<br />NECESSARY TO OBTAIN A CERIFICATE OF OCCUPANCY.
<br />4. CONTRACTORS ARE TO PROVIDE ALL TEMPORARY UTILITIES AND
<br />INFRASTRUCTURE REQUIRED TO PERFORM THE WORK, INCLUDING
<br />FIRE PROTECTION AS REQUIRED DURING CONSTRUCTION.
<br />5. EACH CONTRACTOR AND SUBCONTRACTOR IS EXPECTED TO REVIEW ALL
<br />CONTRACT DOCUMENTS AND SITE CONDITIONS PRIOR TO ISSUED BID.
<br />CHANGE ORDERS WILL NOT BE APPROVED FOR FAILURE TO DO SO.
<br />6. PRODUCTS SPECIFIED OR OTHERWISE INDICATED IN THE CONTRACT
<br />DOCUMENTS SHALL NOT BE SUBSTITUED WITHOUT PRIOR WRITTEN
<br />APPROVAL FROM THE ARCHITECT AND OWNER.
<br />7. THE CONTRACTOR SHALL HAVE INSTALLATION INSTRUCTIONS FOR
<br />ALL EQUIPMENT AND APPLIANCES ON SITE AT TIME OF INSPECTION.
<br />L
<br />8. THIS CONTRACTOR SHALL COORDINATE ALL TRADES REQUIRED TO
<br />COMPLETE THIS PROJECT AS REQUIRED TO ACTIVATE THE USE OF
<br />THE FACILITY AS PLANNED.
<br />9. THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED AND HAS A
<br />FULL FIRE ALARM SYSTEM. THESE SYSTEMS SHALL BE MODIFIED
<br />AS NEEDED TO PROVIDE FIRE PROTECTION FOR THE SPECIFIED
<br />TENANT SPACES. THE CONTRACTOR SHALL SUBMIT SIGNED AND
<br />SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE
<br />LOCAL JURISDICTION FOR PERMITTING. NO WORK ON THE FIRE
<br />PROTECTION SYSTEMS SHALL TAKE PLACE UNTIL THE REQUIRED
<br />PERMITS ARE OBTAINED BY THE FIRE PROTECTION SUB
<br />CONTRACTOR.
<br />10. ALL BUILDING MATERIALS SHALL COMPLY WITH THE REQUIRMENTS
<br />OF TYPE II-B CONSTRUCTION. ALL PLYWOOD SHEATHING AND
<br />WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED (FRT)
<br />11. SEE ENERGY CALCULATION ATTACHED TO THIS SUBMISSION
<br />12. ALL WORK ON THE EXISTING BUILDING SHALL BE PERFORMED IN
<br />ACCORDANCE WITH ALL EXISTING WARRANTIES. THE
<br />CONTRACTOR SHALL CONTACT THE OWNER DIRECTLY TO OBTAIN
<br />ALL EXISTING WARRANTY INFORMATION. THE CONTRACTOR SHALL
<br />PROVIDE THE OWNER WITH DOCUMENTATION VERIFYING THAT ALL
<br />EXISTING WARRANTIES HAVE BEEN MAINTAINED.
<br />Legal Description
<br />A TRACT OF LAND LYING IN THE NORTHEAST 1/4 OF SECTION 34 AND IN THE NORTHWEST 1/4 OF SECTION 35, TOWNSHIP 25
<br />SOUTH, RANGE 21 EAST, PASCO COUNTY, FLORIDA. THE SAME BEING A PORTION OF THE ZEPHYRHILLS COLONY COMPANT
<br />LANDS SUBDIVISION OF SAID SECTION 34 AND 35 AS SHOWN ON THE PLAT OR MAP THEREOF RECORDED IN PLAT BOOK 1, PAGE
<br />55 OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
<br />LESS AND EXCEPT THAT PORTION OF SAID TRACTS 58 AND 59 CONVEYED IN OFFICIAL RECORDS BOOK 1902, PAGE 690, PUBLIC
<br />RECORDS OF PASCO COUNTY, FLORIDA.
<br />SAID LAND CONTAINING 60.76 ACRES MORE OR LESS.
<br />Vicinity Map 'ND
<br />NTS
<br />mI
<br />•- -
<br />Ar M
<br />CO ire ohwDr
<br />W-
<br />KOSSIK RD :3
<br />m
<br />- I PROJECT
<br />'I• SITE
<br />I �_
<br />4.4
<br />31
<br />IFNI
<br />N -
<br />i f I
<br />: I
<br />- L
<br />a
<br />y i .
<br />�tv �t t4
<br />r 9INI
<br />.ry
<br />�.
<br />I �
<br />-
<br />AA :
<br />ter.,
<br />54
<br />t f EMNTY ROAD 54 1
<br />Id
<br />Ll
<br />r,
<br />T
<br />Tenant Buildout for Space B7
<br />Building B at Zephyr Commons
<br />7932 Gall Blvd, Zephyrhills, FL
<br />Scope of Work
<br />1. THE SCOPE IS LIMITED TO TENANT SPACE B7 IN BLDG B.
<br />2. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO THE PARKING LOT, LANDSCAPING, SITE UTILITIES,
<br />SITE DRAINAGE, SITE LIGHTING, OR ANY OTHER SITE FEATURES..
<br />3. THE SCOPE DOES NOT INCLUDE ANY WORK ON ANY OF THE BUILDINGS IN THE SHOPPING CENTER OTHER
<br />THAN BLDG B.
<br />4. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE SIDEWALKS, HARDSCAPE AREAS, OR LANDSCAPE AEAS
<br />IMMEDIATELY ADJACENT TO ANY OF THE BUILDINGS.
<br />5. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE FINISHES, AWNINGS, STONE WORK, OR DECORATIVE
<br />TRIM ON THE EXTERIOR ELEVATIONS OF ANY OF THE BUILDINGS.
<br />6. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE STOREFRONT SYSTEMS, DECORATIVE WINDOWS,
<br />FRONT STOREFRONT DOORS, OR REAR HOLLOW METAL DOORS ON ANY OF THE BUILDINGS.
<br />7932 GALL BLVD, ZEPHYRHILLS, FLORIDA
<br />7. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE EXISTING ROOF SYSTEM OTHER THAN WHAT IS
<br />REQUIRED TO ADD AN EXHAUST FAN AND A VENT FOR THE NEW RESTROOM. THE SCOPE DOES NOT
<br />INCLUDE ANY WORK ON THE SHINGLE ROOFS OR ON THE ROOF DRAINAGE SYSTEMS.
<br />8. THE SCOPE ON THE FRONT FRAMED WALL SHALL BE LIMITED TO WHAT IS NEEDED TO CONSTRUCT THE
<br />NEW TENANT DEMISING WALL. THE EXISTING 1 HOUR FIRE RATING SHALL BE MAINTAINED.
<br />Code Information 9. THE SCOPE INCLUDES ONE NEW TENANT DEMISING WALL.
<br />�i 10. THE SCOPE INCLUDES ADDING SHEATHING OVER METAL FURRING AND RIGID INSULATION ON THE INSIDE
<br />JURISDICTION AUTHORITY OF THE REAR MASONRY WALL INSIDE THE RESTROOM ONLY.
<br />CITY OF ZEPHYRHILLS 3 SIGNED & SEALED SETS FOR PERMIT 11. THE SCOPE INCLUDES INSTALLING A NEW RESTROOM PER ADA REQUIRMENTS.
<br />5335 8TH STREET (813) 780-0020 - PHONE 12. THE SCOPE INCLUDES INSTALLING NEW 2' x 4' ACT CEILINGS IN THE RESTROOM AND THE MAIN ROOM OF
<br />ZEPHYRHILLS, FL 33542 (813) 780-0021- FAX
<br />THE TENANT SPACE.
<br />13. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE FOUNDATIONS, COLUMNS, BEAMS, JOISTS, ROOF
<br />ADOPTED CODES: DECK, OR TRUSSES. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE STRUCTURAL COMPONENTS OF
<br />BUILDING: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS)
<br />THE MASONRY WALL. THE SCOPE DOES NOT INCLUDE ANY STRUCTURAL WORK TO THE EXISTING LIGHT
<br />� � � � " FIRE: FLORIDA FIRE PREVENTION CODE - 2007 (W/ 2009 AMENDMENTS) t'p► `'�" c/� (%� GAUGE FRAMING.
<br />(CHAPTER 36 -NFPA 1 &NFPA 101 W/ STATE FIRE MARSHAL AMENDMENTS) q 14. THE SCOPE INCLUDES SAW -CUTTING THE EXISTING FLOOR SLAB AS NEEDED TO PROVIDE THE NEW
<br />PLUMBING: FLORIDA BUILDING CODE, PLUMBING - 2007 (W/ 2009 AMENDMENTS) T h RESTROOM.
<br />MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL - 2007 (W/ 2009 AMENDMENTS)�s�
<br />ELECTRICAL: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) ai j SA ( 6y-) 15. THE SCOPE INCLUDES RE -POURING ANY PORTION OF THE EXISTING SLAB THAT IS SAW -CUT. IT ALSO
<br />(CHAPTER 27 - NFPA 70, NATIONAL ELECTRIC CODE) qD h ' ,�
<br />FUEUGAS: FLORIDA BUILDING CODE, FUEUGAS - 2007 (W/ 2009 AMENDMENTS) 3 SPACE B7.
<br />ACCESSIBILITY: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) r
<br />(CHAPTER 11- FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION). ZeP 16. THE EXISTING BUILDING HAS A FIRE SPRINKLER SYSTEM WITH THE HEADS TURNED UP. THE SCOPE
<br />ENERGY: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) INCLUDES TURNING DOWN THE SPRINKLER HEADS AND MOVING THEM AS NEEDED TO FIT THE CEILING
<br />(CHAPTER 13 - FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION). LAYOUT. THE SCOPE INCLUDES DESIGN AND PERMITTING BY THE FIRE SPRINKLER SUBCONTRACTOR'S
<br />SPECIALTY ENGINEER THROUGH HIS SHOP DRAWINGS.
<br />REVIEW ---
<br />BUILDING AND CONSTRUCTION DATA Cli`Y QF ZF,PHYRH- ILLS 17. THE SCOPE INCLUDES PROVIDING NEW SANITARY SERVICE, NEW VENT SYSTEM, AND NEW POTABLE
<br />OCCUPANCY CLASSIFICATION (FBC 309) GROUP M - MERCANTILE
<br />PLANS EXAMINER__ -�� _-__--- WATER SERVICE FOR THE RESTROOM.
<br />CONSTRUCTION TYPE (FBC TABLE 601) TYPE II-B, FULLY SPRINKLERED 18. THE SCOPE DOES NOT INCLUDE ANY WORK TO ANY UNDERGROUND SANITARY LINES OTHER THAN WHAT
<br />IS REQUIRED FOR CONNECTION OF THE NEW SANITARY LINES. THE SCOPE DOES NOT INCLUDE ANY
<br />WORK TO ANY OF THE EXISTING CLEAN OUTS.
<br />MAXIMUM HEIGHT AND AREA (FBC TABLE 503)
<br />MAXIMUM HEIGHT 55'-0" - FOUR STORIES
<br />ACTUAL HEIGHT 38'-6" - ONE STORY
<br />MAXIMUM AREA 50,000 SF*
<br />ACTUAL AREAS 15,137 SF
<br />* - THE MAXIMUM AREA ALLOWED BY TABLE 503 HAS BEEN INCREASED
<br />FROM 12,500 SF TO 50,000 SF AS ALLOWED BY FBC 506.1 & 506.3
<br />NOTE:
<br />WIND ZONE =110 MPH. IMPORTANCE FACTOR =1.00
<br />BLDG CATEGORY = II, ENCLOSED. WIND EXPOSURE = B
<br />THE SCOPE OF WORK FOR THIS INTERIOR BUILD OUT DOES NOT INCLUDE ANY
<br />MODIFICATIONS TO ANY EXTERIOR DOORS OR WINDOWS. ALL MODIFICATIONS
<br />TO THE EXISTING ROOF SYSTEM SHALL BE PERFORMED IN ACCORDANCE WITH
<br />THE MIAMI DADE NOTICE OF ACCEPTANCE (NOA).
<br />Contact Information
<br />ftm be advised this review of plans subM11W is S
<br />gxsory review to assist the contractor in oorn*M* VA
<br />applicable fire safety codes. This review is not intended
<br />to be a final approval of the submitWd plans• It is the
<br />contractors sole responsibility to ensure that the plans are in
<br />complete compliance with all applicable NFPA odes and
<br />local ordinances. In the event that further examination or
<br />site inspection reveals areas of non-compliance, it shall be
<br />the contractors sole responsibility, at their sole expense 10
<br />bring those areas in compliance. The City assumes no
<br />responsibility for the contractors failure to be in oornpl'wm
<br />wM all appkable NFPA Codes and local ordinances.
<br />CLIENT: PRIMERICA GROUP ONE, INC.
<br />STRUCTURAL
<br />CUHACI & PETERSON, ARCHITECTS, LLC
<br />3629 MADACA LANE
<br />ENGINEER:
<br />1925 PROSPECT AVE 3UBMITfEL PLAN(S)
<br />TAMPA, FL. 33618
<br />ORLANDO, FL 32814
<br />ZEPHYRHILLS
<br />(813) 933-0629 PHONE
<br />(407) 661-9100 PHONE C•
<br />(813) 935-3420 FAX
<br />Da
<br />(407) 661-9101 FAX Date:
<br />CONTACT: LARRY GARREN
<br />CONTACT: BRETT RYLAND,?svia mr: -- -- __
<br />ARCHITECT: CUHACI & PETERSON, ARCHITECTS, LLC
<br />MECHANICAL
<br />CUHACI & PETERSON, ARCHITECTS, LLC
<br />1925 PROSPECT AVE
<br />ENGINEER:
<br />1925 PROSPECT AVE
<br />ORLANDO, FL 32814
<br />ORLANDO, FL 32814
<br />(407) 661-9100 PHONE
<br />(407) 661-9100 PHONE
<br />(407) 661-9101 FAX
<br />(407) 661-9101 FAX
<br />CONTACT: GABRIEL ROBERTSON
<br />CONTACT: JOE KEENE
<br />CIVIL AVID GROUP
<br />ELECTRICAL
<br />CUHACI & PETERSON, ARCHITECTS, LLC
<br />ENGINEER: 8659 BAYPINE ROAD, STE 304
<br />ENGINEER:
<br />1925 PROSPECT AVE
<br />JACKSONVILLE, FLORIDA 32256
<br />ORLANDO, FL 32814
<br />(904) 7374001 PHONE
<br />(407) 661-9100 PHONE
<br />(904) 252-7030 FAX
<br />(407) 661-9101 FAX
<br />CONTACT: BOB PIERRO
<br />CONTACT: GADY DE ALBA
<br />BVEN kF
<br />001
<br />a
<br />SHEET NO.
<br />ARCHITECTURAL
<br />A000
<br />A100
<br />A101
<br />A102
<br />A103
<br />A001
<br />A002
<br />A003
<br />A004
<br />AREA OF INTERIOR
<br />WORK FOR B7
<br />19. THE SCOPE INCLUDES REMOVAL OF ANY UNUSED PORTION OF THE EXISTING ABOVE GROUND STUBS IN
<br />FOR SPACE B7.
<br />20. THE SCOPE DOES NOT INCLUDE ANY FLOOR DRAINS OR ANY STUB OUTS FOR FUTURE CONNECTION TO
<br />THE SANITARY OR VENT SYSTEMS.
<br />21. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE WATER METER, THE COLD WATER MAIN, OR ANY OF
<br />THE VALVES. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE COLD WATER BRANCH LINE OTHER
<br />THAN WHAT IS REQUIRED FOR CONNECTION OF THE NEW COLD WATER, PIPING.
<br />22. THE SCOPE DOES NOT INCLUDE ANY PROVISIONS FOR HOT WATER OR ANY STUB OUTS OR VALVES FOR
<br />FUTURE CONNECTION TO THE COLD WATER SYSTEM.
<br />23. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO GAS OR GREASE.
<br />24. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE EXISTING 4 TON RTU ABOVE SPACE B7 OTHER THAN
<br />WHAT IS REQUIRED TO CONNECT NEW HVAC DUCTING. THE SCOPE DOES NOT INCLUDE ANY WORK FOR
<br />ANY OTHER RTUS OR ANY OF THE EXISTING CONDENSATE LINES.
<br />25. THE SCOPE INCLUDES PROVIDING A FULL HVAC SYSTEM.
<br />26. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE BUILDING TRANSFORMER, SECONDARY CONDUIT,
<br />SECONDARY WIRE, MAIN DISCONNECT, WIREWAY, TENANT METER OR TENANT DISCONNECT.
<br />27. THE SCOPE INCLUDES PROVIDING A NEW 200 AMP TENANT PANEL CONNECTED TO THE EXISTING
<br />DISCONNECT VIA NEW WIRE PULLED THROUGH THE EXISTING EMPTY CONDUIT.
<br />28. THE SCOPE INCLUDES PROVIDING NEW POWER RECEPTACLES WIRED TO THE TENANT PANEL.
<br />29. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING SIGN JUNCTION BOX ON THE FRONT OF
<br />THE BUILDING OTHER THAN WIRING IT TO THE TENANT PANEL.
<br />30. THE SCOPE INCLUDES WIRING THE EXISTING RTU AND ALL OTHER COMPONENTS OF THE HVAC SYSTEM
<br />TO THE TENANT PANEL.
<br />31. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE SCONCE FIXTURES ON THE FRONT OF THE
<br />BUILDING OR THEIR WIRING.
<br />32. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING WALL MOUNTED LIGHT FIXTURE ON THE
<br />REAR OF THE BUILDING OTHER THAN WIRING IT TO THE TENANT PANEL VIA A LIGHT SWITCH.
<br />33. THE SCOPE INCLUDES PROVIDING NEW EXIT AND EMERGENCY LIGHTS. THESE LIGHTS SHALL BE WIRED
<br />TO THE NEW TENANT PANEL.
<br />34. THE SCOPE INCLUDES PROVIDING NEW 2' x 4' FLUORESCENT LIGHT FIXTURES WIRED TO THE TENANT
<br />PANEL VIA SWITCHES LOCATED AT THE REAR DOOR..
<br />35. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING TELEPHONE SYSTEM.
<br />36. THE EXISTING BUILDING HAS A FIRE ALARM SYSTEM. THE SCOPE INCLUDES MODIFYING THE SYSTEM AS
<br />NEEDED FOR THE TENANT BUILD OUT. THE SCOPE INCLUDES DESIGN AND PERMITTING OF THE FIRE
<br />ALARM SYSTEM BY THE CONTRACTOR THROUGH SHOP DRAWINGS.
<br />Drawing Index
<br />TITLE ON SHEET PERMIT SET
<br />2010_08-27 :1 1 i i
<br />COVER SHEET
<br />X
<br />PROJECT SITE PLAN
<br />X
<br />SPACE B7 PLANS
<br />X
<br />SPACE B7 DETAILS
<br />X
<br />SPACE B7 DETAILS
<br />X
<br />B7 SPECIFICATIONS
<br />X
<br />B7 SPECIFICATIONS
<br />X
<br />B7 SPECIFICATIONS
<br />X
<br />B7 SPECIFICATIONS
<br />X
<br />FIRE PROTECTION NOTE - THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED. THE SPRINKLER SYSTEM SHALL BE MODIFIED AS NEEDED FOR SPACE B7. ALL MODIFICATIONS TO THE SPRINKLER SYSTEM SHALL BE
<br />DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE LOCAL JURISDICTION FOR PERMITTING.
<br />,PLUMBING
<br />P101 PLUMBING GENERAL INFORMATION FLOOR PLAN & RISERS X
<br />MECHANICAL
<br />M101 MECHANICAL GENERAL INFORMATION & FLOOR PLAN X
<br />ELECTRICAL
<br />E101 ELECTRICAL LEGEND SCHEDULES POWER & LIGHTING PLANS X _
<br />E501 ELECTRICAL SPECIFICATIONS X
<br />FIRE ALARM NOTE - THE EXISTING SHELL BUILDING HAS A FULL FIRE ALARM SYSTEM. THE FIRE ALARM SYSTEM SHALL BE MODIFIED AS NEEDED FOR SPACE B7. ALL MODIFICATIONS TO THE FIRE ALARM
<br />SYSTEM SHALL BE DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS TO THE LOCAL JURISDICTION FOR PERMITTING.
<br />C
<br />1 Z
<br />5 CD
<br />Co
<br />C4 <c Q
<br />ED z25
<br />wLL
<br />F-
<br />co
<br />Ri
<br />•
<br />
|