Laserfiche WebLink
EXISTING 1 HOUR RATED EMERGENCY LIGHT EXIT LIGHT <br />TENANT DEMISING WALL <br />1. --- - ---- <br />do <br />do I <br />OD <br />l � <br />/ PATH OF EGRESS <br />MAX EXIT DISTANCE = 35' owl <br />EXISTING 36" REAR <br />DOOR (33" CLEAR <br />WHEN DOOR IS OPEN) <br />EGRESS CAPACITY ( -- EXIT LIGHT <br />= 165 PEOPLE �Q i <br />i <br />EXISTING REAR <br />CONCR. SIDEWALK <br />TO REMAIN AS IS <br />EXISTING <br />TELEPHONE <br />CONDUIT STUB IN <br />TO REMAIN AS IS <br />NEW ELEC. <br />PANEL. RE: E101 <br />EXISTING TX T HM <br />DOOR (TYPE B) TO <br />REMAIN AS IS <br />EXISTING <br />DOWNSPOUT <br />TO REMAIN AS IS <br />_ I � <br />L- FIRE EXTINGUISHER ENCY LIGHT <br />EMERGENCY <br />1200 SF MERCANTILE SPACE <br />OCCUPANT LOAD = 40 PEOPLE <br />N Life Safety Plan <br />SCALE: 1/8" = 1'-0" <br />TENANT DEMISING WALL <br />MIN 1 HR FIRE RATING <br />RE: UL DETAILS, U419 <br />60'-0" LEASABLE <br />OUTSIDE FACE OF WALL TO OUTSIDE FACE OF WALL <br />56-94" INTERIOR CLEAR <br />INSIDE FACE OF FRONT WALL FINISH TO INSIDE FACE OF REAR CMU <br />(OUTSIDE OF RESTROOM) <br />NEW RESTROOM EXISTING FRAMED <br />/ RE: A102-1 DEMISING WALL <br />B I <br />I- EDGE OF EXISTING <br />A C SLAB LEAVE OUT <br />D <br />HOLLOW CORE DOOR. <br />(TYPE C) RE: A102 <br />FILL IN EXISTING SLAB LEAVE <br />OUT IN REAR OF SPACE <br />1 <br />NO FINISHES ADDED TO THE EXISTING <br />REAR WALL OUTSIDE OF THE RESTROOM <br />� I <br />V <br />AREA OF EXISTING SLAB EXISTING STEEL <br />LEAVE OUT TO REMAIN COLUMN TO BE <br />HIDDEN IN NEW WALL <br />N 2 Floor Plan <br />SCALE: 1/8" = 1'-0" <br />w <br />J <br />m <br />a <br />w <br />J <br />0 <br />0 <br />N <br />Code Information <br />JURISDICTION AUTHORITY <br />CITY OF ZEPHYRHILLS 3 SIGNED & SEALED SETS FOR PERMIT <br />5335 8TH STREET (813) 780-0020 - PHONE <br />ZEPHYRHILLS, FL 33542 (813) 780-0021 - FAX <br />ADOPTED CODES: <br />ALL PENETRATIONS IN FIRE RATED <br />BUILDING: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />WAI. L.S SHAI I BF SFALFD SO AS <br />FIRE: FLORIDA FIRE PREVENTION CODE - 2007 (W/ 2009 AMENDMENTS) <br />TO MAINTAIN THE MIN. REQUIRED <br />(CHAPTER 36 - NFPA 1 & NFPA 101 W/ STATE FIRE MARSHAL AMENDMENTS) <br />FIRE RATING. RE: UL DETAILS <br />PLUMBING: FLORIDA BUILDING CODE, PLUMBING - 2007 (W/ 2009 AMENDMENTS) <br />MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL - 2007 (W/ 2009AMENDMENTS) <br />ELECTRICAL: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />THE EXISTING DOOR HARDWARE <br />(CHAPTER 27 - NFPA 70, NATIONAL ELECTRIC CODE) <br />ON THE EXISTING FRONT AND REAR <br />FUEL/GAS: FLORIDA BUILDING CODE, FUEL/GAS - 2007 (W/ 2009 AMENDMENTS) <br />DOORS MEETS ADA REQUIREMENTS <br />ACCESSIBILITY: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />(CHAPTER 11 - FLORIDAACCESSIBILITY CODE FOR BUILDING CONSTRUCTION). <br />ENERGY: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />(CHAPTER 13 - FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION). <br />- EXISTING 36" FRONT DOOR <br />(33" CLEAR WHEN DOOR IS OPEN) <br />EGRESS CAPACITY = 165 PEOPLE <br />BUILDING AND CONSTRUCTION DATA <br />OCCUPANCY CLASSIFICATION (FBC 309) GROUP M - MERCANTILE <br />�� -- - EXISTING FRONT FRAMED WALL <br />CONSTRUCTION TYPE (FBC TABLE 601) TYPE II-B, FULLY SPRINKLERED <br />HAS A 1 HOUR FIRE RATING. ALL <br />WORK RELATED TO THE FRONT <br />MAXIMUM HEIGHT AND AREA (FBC TABLE 503) <br />WALL SHALL BE PERFORMED SO <br />MAXIMUM HEIGHT 55'-0" - FOUR STORIES <br />AS TO MAINTAIN THE WALL'S <br />ACTUAL HEIGHT 38'-6" - ONE STORY <br />EXISTING FIRE RATING. <br />EX <br />MAXIMUMAREA 50,000 SF" <br />- <br />ACTUALAREAS 15,137 SF <br />THE MAXIMUM AREAALLOWED BY TABLE 503 HAS BEEN INCREASED <br />FROM 12,500 SF TO 50,000 SF AS ALLOWED BY FBC 506.1 & 506.3 <br />w <br />---�- <br />- <br />EXISTING FRONT FRAMED <br />WALL TO REMAIN AS IS <br />z <br />� I <br />o <br />w <br />EXISTING 9' HIGH <br />U <br />- <br />STOREFRONT SYSTEM <br />ijs <br />- -� <br />W/ 3' X T DOOR (TYPE A) <br />TO REMAIN AS IS <br />U <br />---� <br />CONCRETE SIDEWALK <br />o <br />TO REMAIN AS IS <br />w <br />w H <br />LANDSCAPEAREA <br />TO REMAIN AS IS <br />NEW 6" DEMISING WALL <br />RE: WALL TYPE B <br />NEW EXHAUST EXISTING 4 TON RTU ABOVE NEW RETURN AIR NEW EMERGENCY LIGHT EXISTING SCONCE <br />FAN. RE: M101 TO BE WIRED AND DUCTED. j GRILLE. RE: M101 FIXTURE. RE: E101 LIGHT FIXTURE <br />RE: MECH & ELEC PLANS - TO REMAIN AS IS <br />v <br />I <br />EXISTING AWNING <br />- - ABOVE STOREFRONT <br />TO REMAIN AS IS <br />Vop <br />NEW EXIT LIGHT <br />FIXTURE. RE: E101 <br />EXISTING RAIN <br />HOOD OVER REAR <br />DOOR TO REMAIN x <br />AS IS / r EXISTING SCONCE <br />LIGHT FIXTURE <br />O4� / TO REMAIN AS IS <br />NEW EXIT LIGHT <br />FIXTURE. RE. E101 <br />EXISTING SCONCE NEW 2' X 4' ACOUSTICAL TILE NEW SUPPLY AIR <br />LIGHT FIXTURE CEILINGS MOUNTED AT 10'-0" DIFFUSER. RE: M101 <br />TO REMAIN AS IS ABOVE FLOORS IN RESTROOM II <br />AND IN MAIN ROOM II <br />.r I <br />I I <br />B/ DI <br />v C <br />FLOOR PLAN GENERAL NOTES: <br />1. NEW DEMISING WALL SHALL HAVE PROVIDE A MINIMUM FIRE <br />RATING OF 1 HOUR. REFER TO WALL TYPES AND UL DETAILS. <br />2. ON THE INSIDE OF RESTROOMS, WALLS SHALL RECEIVE ENAMEL <br />PAINT OVER MOISTURE RESISTANT GYPSUM BOARD. IN ALL <br />OTHER LOCATIONS, WALLS SHALL RECEIVE REGULAR GYPSUM <br />BOARD AND SHALL BE LEFT PAINT READY. <br />3. THE PORTION OF THE EXISTING REAR MASONRY WALL THAT IS <br />OUTSIDE OF THE RESTROOM SHALL BE LEFT EXPOSED WITH <br />NO FINISH OR PAINT ADDED. <br />4. THE RESTROOM SHALL HAVE VCT FLOORING AND A 6" VINYL BASE <br />ON THE INSIDE OF ALL WALLS. THE FLOORS IN OTHER AREAS SHALL <br />BE EXPOSED CONCRETE. NO OTHER WALLS SHALL RECEIVE BASES. <br />5. REFERTOA102 FOR COMPLETE BATHROOM INFORMATION. <br />6. REFER TO A102 FOR COMPLETE DOOR & HARDWARE INFORMATION. <br />7. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. <br />8. GC MAY SUBMIT ALTERNATE DESIGN FOR STUD GAUGE & SPACING. <br />IF AN ALTERNATE DESIGN IS PROPOSED, THE GC MUST SUBMIT <br />INFORMATION TO THE OWNER FOR APPROVAL PRIOR TO ORDERING <br />ANY MATERIALS. THE SUBMITTAL MUST INCLUDE STRUCTURAL <br />INFORMATION VERIFYING THAT THE DESIGN IS ADEQUATE FOR THE <br />WALL'S REQUIRED HEIGHT, LOADING, AND DEFLECTION. IT MUST <br />ALSO INCLUDE PRICE COMPARISON INFORMATION. <br />RE: WALL TYPE DETAILS ON THIS SHEET. <br />CEILING PLAN GENERAL NOTES: <br />1. ALL NEW CEILINGS SHALL BE 2' X 4' ACT MOUNTED <br />AT 10'-0"AFF WITH NO INSULATION. <br />2. ALL EXISTING EXTERIOR LIGHTS SHALL REMAIN. NO <br />NEW EXTERIOR LIGHTS ARE BEING ADDED. <br />3. REFER TO E101 FOR COMPLETE WIRING INFORMATION <br />FOR ALL LIGHT FIXTURES. <br />4. REFER TO M101 FOR COMPLETE INFORMATION <br />FOR THE HVAC SYSTEM. <br />5. THE LOCATIONS OF THE FIRE SPRINKLER HEADS SHALL BE <br />DETERMINED BY THE FIRE SPRINKLER SUBCONTRACTOR'S <br />SPECIALTY ENGINEER DURING THE DESIGN OF HIS / HER <br />SHOP DRAWINGS. THE CONTRACTOR SHALL COORDINATE <br />THE HEAD LOCATIONS WITH ALL OTHER DISCIPLINES TO <br />AVOID ANY CONFLICTS. <br />SECTION <br />EXISTING MASONRY - <br />WALL TO REMAIN AS IS <br />EXISTING COREFILL <br />FOAM INSULATION TO <br />REMAIN AS IS <br />EXISTING EXTERI( <br />FINISHES TO REM <br />AS THEY ARE <br />EXISTING EXTERI( <br />SIDEWALKS AND <br />ADJACENT LANDS <br />AREAS TO REMAII <br />AS THEY ARE <br />PLAN VIEW <br />SECTION <br />FIRE RATING REQUIREMENTS <br />FBC TABLES 601 & 602 FIRE RATING REQUIREMENTS <br />FOR CONSTRUCTION TYPE II-B <br />ELEMENT <br />REQUIRED FIRE RATING <br />STRUCTURALFRAME <br />0HR <br />LOAD BEARING EXTERIOR WALLS <br />2 HR <br />(F.S.D. < 5') <br />LOAD BEARING EXTERIOR WALLS <br />1 HR <br />PROVIDED AS <br />(F.S.D. BETWEEN S & 10') <br />PART OF SHELL <br />LOAD BEARING EXTERIOR WALLS <br />U HR <br />(F.S.D. > 10') <br />ROOF CONSTRUCTION <br />0 HR <br />FLOOR CONSTRUCTION <br />0 HR <br />NON BEARING INTERIOR WALLS <br />0 HR <br />F.S.D. IS FIRE SEPARATION DISTANCE <br />FBC 708 - OTHER FIRE RATING REQUIREMENTS <br />TENANTS SHALL BE SEPARATED BYA MIN 1 HR FIRE BARRIER <br />FBC 803 - CLASSIFICATION OF INTERIOR FINISHES <br />FBC 803.1 - FLAMESPREAD <br />A-FLAMESPREAD 0-25, SMOKE DEV. 0-450 <br />CLASSIFICATIONS <br />B-FLAMESPREAD 26-75, SMOKE DEV. 0-450 <br />C-FLAMESPREAD 76-200, SMOKE DEV. 0-450 <br />TABLE 803.5 - REQUIRED <br />EXIT PASSAGEWAYS - CLASS B <br />FLAMESPREAD FOR MERCANTILE <br />EXIT ACCESS CORRIDORS CLASS C <br />OCCUPANCY (SPRINKLERED) <br />ROOMS & OTHER SPACES CLASS C <br />FIRE PROTECTION SYSTEMS, FBC 900 <br />FBC 903 - SPRINKLERS <br />DESIGN STANDARD NFPA 13 AS <br />MODIFIED BY NFPA231 & NFPA 231C <br />FBC 903.2.6 - GROUP M REQUIREMENTS <br />FIRE SPRINKLERS REQUIRED IN GROUP <br />M WHEN GROSS AREA > 12,000 SF <br />(REQUIRED, PROVIDED) <br />FBC 906 - PORTABLE FIRE EXTINGUISHERS <br />EACH TENANT SPACE IS PROVIDED WITH <br />A PORTABLE FIRE EXTINGUISHER <br />FBC 907.2.7 FIRE ALARMS <br />FIRE ALARMS REQUIRED IN GROUP M <br />WHEN OCCUPANT LOAD > 500 <br />(REQUIRED, PROVIDED) <br />E^ING ti n q YM aso L WITH n�rG AND Wall <br />EXiSTSHEATHING ADDED TO THE INTERIOR SIDE. <br />TO BE USED ALONG THE REAR WALL INSIDE OF THE RESTROOM <br />SCALE: 1 1/2" = V-0" <br />112" GYP BOARD BOTI . <br />SIDES OF FRAMING. <br />FRAMING, SHEATF""" <br />& INSULATION TO <br />TERMINATE 6"AB( <br />CEILING. <br />�^1 <br />New 6" Metal Stud Wall <br />NO FIRE RATING <br />TO BE USED FOR RESTROOM WET WALL. <br />SCALE: 1 1/2" = 1' C' <br />1 1/2" RIGID <br />INSULATION <br />FURRING, SHEATHING, <br />& INSULATION TO RUN <br />FROM FLOOR SLAB <br />TO 6" ABOVE CEILING <br />SUSPENDED CEILING <br />RE: CEILING PLAN <br />1/2" GYP BOARD OVER <br />1 1/2" Z-FURRING <br />CHANNELS @ 24" OC <br />MAX SPACING <br />6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY <br />NEW CONCRETE <br />FLOOR SLAB IN <br />AREA OF EXISTING <br />SLAB LEAVE OUT <br />CONTINUOUS STUD AT <br />TOP OF WALL <br />MTL STUD FRAMING <br />600S125-43 @ 24' OC <br />LAY -IN CEILING, RE: RCP <br />R-19 SOUND BATTS <br />CONTINUOUS STUD TRACK <br />60OT125-43 <br />6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY <br />CONCRETE <br />FLOOR SLAB <br />SECTION <br />THIS BUILDING HAS A FULL FIRE SPRINKLER SYSTEM, THE CONTRACTOR SHALL <br />PREPARE SHOP DRAWINGS FOR REVISIONS TO THE SYSTEM AS NEEDED FOR THE <br />BUILDOU T OF THE SPACE. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED <br />SHOP DRAWINGS TO THE LOCAL JURISDICTION AS REQUIRED FOR PERMITTING. <br />THIS BUILDING HAS A FULL FIRE ALARM SYSTEM. THE CONTRACTOR SHALL <br />PREPARE SHOP DRAWINGS FOR REVISIONS TO THE SYSTEM AS NEEDED FOR THE <br />BUILDOUT OF THE SPACE. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED <br />SHOP DRAWINGS TO THE LOCAL JURISDICTION AS REQUIRED FOR PERMITTING. <br />MEANS OF EGRESS, FBC 1000 <br />OCCUPANCY CLASSIFICATION MERCANTILE (SPRINKLERED) <br />FLOOR AREAS AT GRADE <br />FBC 1004.1.1 - OCCUPANT LOAD 1 PERSON / 30 SF (GROSS) <br />FBC 1005.1 - EGRESS WIDTH / PERSON 0.2" / PERSON <br />FBC 1008.1.1 - MIN. CLEAR DOOR OPENING 32" MIN <br />FBC 1016.1 - MAX. TRAVEL DISTANCE 250' MAX <br />FBC 1019.1 - MIN. NUMBER OF EXITS 2 WHEN OCCUPANT LOAD 1-500 <br />EGRESS WIDTH # OF EXITS <br />TENANT GROUP SIZE (SF) OCCUR LOAD (REQ'D / PROV'D) (REQ'D / PROV'D) <br />B7 M 1,200 1 / 30 40 8.0" / 66" 2 / 2 <br />FBC PLUMBING 403 - MINIMUM FACILITIES <br />OCCUPANCY - MERCANTILE (1 PERSON PER 30 SF GROSS) <br />PFBC TABLE 403.1 - # OF FIXTURES REQUIRED PER PERSON <br />MEN'S WATER CLOSETS 1 / 500 BATHTUB / SHOWER NOT REQUIRED <br />WOMEN'S WATER CLOSETS 1 / 500 DRINKING FOUNTAINS 1 / 1,000 <br />LAVATORIES 1 / 750 SERVICE SINK NOT REQUIRED <br />PFBC 403.2.4 - SEPARATE FACILITIES NOT REQUIRED IN GROUP M WHEN <br />FLOOR AREA <3000 SQ. FT. <br />SPACE SIZE (SF) LOAD FIXTURES (REQUIRED / PROVIDED) <br />WC LAV DF <br />B7 1,200 40 1/ 1 1/ 1 112 <br />5/8" GYP BOARD BOTH <br />SIDES OF FRAMING. <br />FRAMING, SHEATHING, <br />& INSULATION TO <br />TERMINATE AT UNDERSIDE <br />OF ROOF STRUCTURE ABOVE <br />WALL CONSTRUCTION SHALL <br />BE CONSISTENT WITH UL <br />DETAILS U419, HW-S-0001, & <br />W-L-1001 TO PROVIDE A MIN. <br />1 HOUR FIRE RATING. <br />PLAN VIEW <br />New 6" Metal Stud Wall <br />1 HOUR FIRE RATING <br />TO BE USED FOR TENANT DEMISING WALLS <br />SCALE: 1 1/2" = V-0" <br />SECTION <br />112" GYP BOARD B0 <br />SIDES OF FRAMING. <br />FRAMING, SHEATHING, <br />& INSULATION TO <br />TERMINATE 6"ABOVE <br />CEILING. <br />PLAN VIEW <br />EXISTING ROOF DECK <br />-CONTINUOUS STUD AT <br />TOP OF WALL <br />MTL STUD FRAMING <br />60OS125-43 @ 24" OC <br />R-19 SOUND BATTS <br />CONTINUOUS STUD <br />TRACK 60OT125 43 <br />6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY <br />CONCRETE <br />FLOOR SLAB <br />- CONTINUOUS STUD AT <br />TOP OF WALL <br />MTL STUD FRAMING <br />362S12543 @ 24" OC <br />\� LAY -IN CEILING, RE: RCP <br />R-11 SOUND BATTS <br />CONTINUOUS STUD TRACK <br />362T125A3 <br />New 3 /8" Metal Stud Wall <br />NO FIRE RATING <br />TO BE USED FOR THE RESTROOM NON -WET WALI-S <br />SCALE: 1 '112" = V-0" <br />— 6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY <br />CONCRETE <br />FLOOR SLAB <br />0 <br />o <br />o <br />0 <br />U <br />0 <br />0 <br />o <br />rr^^ <br />�1 <br />2 <br />N <br />M � <br />U <br />b� <br />as <br />b <br />r r-0 <br />O <br />Q C <br />G3, <br />� o, <br />U <br />�sZ <br />�o <br />N <br />Ln� 3 <br />r--� <br />a 3 <br />0 <br />E <br />E <br />0 <br />U <br />C <br />N -- <br />m <br />MM� J <br />I..Ld m <br />a) <br />V¢_j <br />C6 p LE <br />0-5 Uj <br />v/ m J <br />z <br />CUCD>_ <br />v <br />2 <br />�CVLLI <br />0 <br />��N <br />a_ <br />m <br />Z <br />_ <br />Uj C:)W O) <br />co <br />Q Q <br />Z <br />♦ Uj <br />>) <br />w LI <br />w <br />m <br />Of <br />w <br />w <br />p <br />w <br />� <br />Q <br />w <br />o <br />N <br />w <br />v <br />Q <br />N <br />co <br />Z mI <br />U a <br />W <br />_ <br />u m <br />W CN o <br />lLi N <br />J <br />C7 <br />C.) (� <br />Of <br />z <br />0 <br />0___.__._ I <br />j N-1 <br />Reflected ,,edin Plan <br />SCALE: 1/8" = 1'-0" <br />p <br />