My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7940 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7940 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:57:23 PM
Creation date
2/19/2025 11:53:25 AM
Metadata
Fields
Template:
Building Plans
Street #
7940
Location
Gall Blvd
Contractor
Faithbilt Builders Contractor
Building Plans - Permit #
9209
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXISTING REAR SIDEWALK IS FLUSH <br />WITH ADJACENT PAVEMENT ALONG <br />THE ENTIRE REAR OF BUILDING B <br />FIRE HYDRANT <br />RE: CIVIL PLANS <br />�r <br />EXISTING BLDG B <br />FIRE RISER ROOM <br />Ii <br />N -- FIRE HYDRANT <br />L.... RE: CIVIL PLANS <br />I <br />-0 <br />FIRE HYDRANT <br />88 " 20' " I <br />FROM OUTSIDE FACE OF CMU TO <br />° CENTER LINE OF DEMISING WALL I I Bldg C Bldg D Bldg E Bldg F <br />VERIFY IN FIELD <br />�' -►- - I B5 I Bldg B EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING ` # <br />+ TO REMAIN AS IS. TO REMAIN AS IS. TO REMAIN AS IS. TO REMAIN AS IS. <br />I � <br />p <br />I�Wr <br />N. <br />o n — <br />-°�- -- Q I -----� G D ---- --- -- <br />--� "" • •ell, EXISTING REFER TO SHEET A101 FOREXISTING <br />HANDICAP RAMP ENLARGED PLANS & LIFE HANDICAP RAMP <br />- 6-- SAFETY INFORMATION � „� � ,,,_ i <br />" - a <br />_s <br />FIRE HYDRANT <br />RE: CIVIL PLANS <br />° <br />�I <br />Parcel 1 = <br />, <br />THIS PARCEL TO BE <br />DESIGNED, PERMITTED, • <br />AND CONSTRUCTED AS <br />A SEPARATE SET <br />OF DRAWINGS . - + • <br />I <br />�I <br />1 <br />FIRE HYDRANT <br />0.- <br />E)D <br />.. RE. CIVIL PLANS <br />—-:4111111111111 I1111 -� I111f - 1 <br />- <br />- <br />Ii <br />j FIRE HYDRANT I I FIRE HYDRANT <br />RE: CIVIL PLANS _ RE: CIVIL PLANS <br />II • - <br />.� <br />L Parcel 2 Parcel 3 Parcel 4 Parcel 5 <br />THIS PARCEL TO BE <br />THIS PARCEL TO BE THIS PARCEL TO BE THIS PARCEL TO BE <br />I' = DESIGNED,PERMITTED DESIGNED PERMITTED <br />i <br />DESIGNED PERMITTED DESIGNED PERMITTED <br />AND CONSTRUCTED AS I AND CONSTRUCTED AS AND CONSTRUCTED AS I I AND CONSTRUCTED AS <br />A SEPARATE SET A SEPARATE SET A SEPARATE SET A SEPARATE SET <br />OF DRAWINGS I OF DRAWINGS OF DRAWINGS j _I i OF DRAWINGS <br />I <br />I <br />LL I I I I I I a I I i� I I I i I iq L___—___—___—___—___—___—1--- ---- --- ---- L--- —--- <br />—___—___—.__—___—.__—___—__.—___J�__�___ <br />f <br />r <br />�. AJAll. <br />Alt <br />s <br />�z <br />Overall Project Site Plan <br />s � <br />N SCALE:1"=40'-0" <br />THIS SET OF DRAWINGS IS LIMITED TO TENANT B5 ONLY. REFER TO THE COVER SHEET FOR A COMPLETE <br />DESCRIPTION OF THE SCOPE OF WORK COVERED IN THIS SET OF DRAWINGS. <br />BUIILDINGS C, D, E, & F ARE EXISTING AND ARE TO REMAIN AS IS. <br />ALL OTHER FUTURE BUILDINGS AND PARCELS SHALL BE DESIGNED, PERMITTED, AND CONSTRUCTED SEPARATELY. <br />FOR COMPLETE SITE WORK INFORMATION, REFER TO THE CIVIL DRAWINGS PREPARED BY AVID. <br />FOR COMPLETE LANDSCAPE AND IRRIGATION INFORMATION, REFER TO THE CIVIL DRAWINGS PREPARED BY AVID. <br />FOR COMPLETE SITE LIGHTING INFORMATION, REFER TO THE BUILDING B SHELL ELECTRICAL DRAWINGS. <br />Elevation & Grading Notes <br />1. ABBREVIATIONS: <br />TOS - TOP OF FLOOR SLAB INSIDE BUILDING <br />TOC - TOP OF CURB AT EDGE OF SIDEWALK <br />TOP - TOP OF PAVING <br />2. EXISTING TOS=113.00'. <br />3. ALL SIDEWALKS ARE EXISTING AND START 1/4" BELOW THE <br />TOS AT ALL DOORS. <br />4. ALL EXTERIOR DOORS ARE EXISTING AND HAVE EXISTING <br />THRESHOLDS THAT DO NOT EXCEED 1/2" IN HEIGHT. <br />5. ALL SIDEWALKS ARE EXISTING AND SLOPE AWAY FROM THE <br />BUILDING AT A RATE BETWEEN 1% MIN AND 2% MAX. <br />6. AT ALL FRONT SIDEWALKS, TOC IS 6" MAX ABOVE ADJACENT TOP. <br />7. AT ALL REAR SIDEWALKS, TOC IS FLUSH WITH ADJACENT TOP. <br />8. ALL HANDICAP RAMPS ARE EXISTING AND HAVE A SLOPE OF 1:14 <br />MAX. THE SURFACES OF ALL CURB RAMPS HAVE RAISED <br />DETECTABLE WARNING FINISHES. <br />9. THE BOTTOMS OF ALL HANDICAP RAMPS ARE FLUSH WITH <br />THE ADJACENT TOP <br />10. REFER TO CIVIL DRAWINGS FOR EXACT ELEVATIONS. <br />11. THE CONTRACTOR SHALL FIELD VERIFY ALL SIDEWALK AND <br />GRADING CONDITIONS PRIOR TO STARTING WORK. THE GC <br />SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF ANY OF THE <br />EXISTING CONDITIONS DO NOT MEET ADA REQUIREMENTS. <br />Fire Marshal's Checklist <br />EGRESS TRAVEL AND EXITS <br />RE: LIFESAFETY PLAN & CODE INFO ON A101 <br />EXIT AND EMERGENCY LIGHTS <br />RE: LIFESAFETY PLAN ON A101 <br />A FIRE ALARM SYSTEM WILL BE DESIGNED AND PERMITTED BY <br />SMOKE DETECTORS <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A101 <br />FIRE EXTINGUISHERS <br />RE: LIFESAFETY PLAN ON A101 FOR LOCATIONS <br />FIRE RATED WALLS <br />RE: LIFESAFETY PLAN ON A101 FOR LOCATIONS & UL DETAILS <br />ALL DOORS SHALL HAVE HARDWARE THAT COMPLIES WITH <br />PANIC HARDWARE <br />REQUIREMENTS FOR EGRESS AND ADA ACCESSIBILITY. <br />RE: LIFESAFETY PLAN ON A101 FOR DOOR LOCATIONS <br />DUCT DETECTORS SHALL BE PROVIDED AS REQUIRED BY SMACK NFPA, <br />DUCT DETECTORS <br />AS WELL AS ANY OTHER APPLICABLE CODE <br />RE: MECHANICAL DRAWINGS FOR HVAC INFORMATION <br />EMERGENCY GENERATOR <br />NONE REQUIRED. NONE PROVIDED. <br />RE: A101 FOR ROOF FINISH INFO & CODE INFORMATION <br />INTERIOR FINISHES <br />FOR FLAME SPREAD RATINGS <br />SITE PLAN SHOWING ADJACENT <br />RE: OVERALL PROJECT SITE PLAN ON A100. FOR COMPLETE SITE <br />ROADWAYS, BUILDINGS, AND <br />WORK AND UTILITY INFORMATION, RE: CIVIL DRAWINGS BY AVID. <br />FIRE HYDRANTS <br />FULL SYSTEM PROVIDED. TO BE DESIGNED AND PERMITTED BY <br />FIRE ALARM <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A101 <br />FULL SYSTEM PROVIDED. TO BE DESIGNED AND PERMITTED BY <br />SPRINKLERS <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A101 <br />GAS USAGE <br />NONE REQUIRED. NONE PROVIDED. <br />O' <br />o <br />0 <br />U <br />eVe�. <br />a <br />-- <br />00 <br />�^�� <br />w <br />M o <br />CD <br />o U <br />2 8 <br />4 <br />U <br />u <br />U <br />C <br />a� <br />O <br />Q <br />0 <br />V LLI <br />MZ��-- <br />V Q co <br />CO <br />0U- <br />Q "E�a <br />w ��Q <br />J <br />U <br />Cn <br />C <br />O <br />E <br />E <br />O <br />U <br />L <br />Nm <br />CU Q <br />LO J <br />W m <br />Ua <br />' J <br />:5 LL <br />�� / <br />vJmJ <br />J = <br />U <br />�Lu <br />NLu <br />(DN <br />0 <br />a <br />Cu <br />0- <br />65 <br />w _(D_ <br />O <br />~ L <br />L <br />w <br />w <br />x <br />Cn <br />Z_ <br />as,W <br />M <br />� <br />m rn <br />Z < <br />1� <br />; J <br />=V■ <br />W LL <br />v) <br />w <br />En <br />F- <br />w <br />a <br />0 <br />0 <br />rn� <br />Qw <br />o <br />uJ <br />N <br />J <br />W <br />w <br />ao <br />Z <br />Q <br />m <br />C) <br />N <br />o <br />CID <br />N <br />i <br />CD <br />N <br />Zof <br />C7 <br />Q <br />w <br />Co <br />0 <br />= <br />a <br />o <br />o <br />U <br />A100 <br />
The URL can be used to link to this page
Your browser does not support the video tag.