Laserfiche WebLink
-III . _i—.1,-L. ;� .: . �4 W111111ri11 1JJ�ulu a: lIIJl l 4, I� I : , — <br />E & <br />- <br />e <br />—11 r <br />SITE UTILITY NOTE <br />PLUMBING CONTRACTOR SHALL COORDINATE THE <br />LOCATION AND INVERTS OF ALL PIPING FOR <br />CONNECTION TO THE APPROPRIATE UTILITY AS <br />SHOWN ON UTILITY PLAN. THIS COORDINATION <br />SHOULD TAKE PLACE PRIOR TO GRADING AND <br />INSTALLATION OF PIPES. THIS CONTRACTOR <br />SHALL MAKE FINAL CONNECTIONS TO THE <br />RECEIVING UTILITY. <br />0 <br />GAS METER (7-WC) <br />1276 CFH TOTAL <br />LOAD AT 89 EQUIV. <br />LENGTH. <br />2"GAS <br />r-I <br />. I r:e --- <br />x <br />J ✓r' "L� � � I r <br />1 RTU-A <br />�CFH <br />1 "GAS <br />M <br />r.7" <br />[ <br />PA <br />4_e <br />rd <br />320 <br />a <br />NOTE: <br />GAS PIPING SIZED PER <br />/4"GAS ' y TABLE 402.4(2) OF THE <br />1-1 <br />1-1 20061FGC. <br />-- WH-A <br />250 CFH j. <br />.., i:. <br />f x, _ <br />1-1/2" EXPOSIcB 6ft9Id, --} <br />WITH CLAMPING DEVI� - T <br />AND AUTO SHUT-O <br />CONNECTION TO F <br />PROTECTION SY I <br />CONTRACTOR OORDINATE <br />EXACT GAS IN A LATION- - <br />WITH FIVE GUYS UCTION <br />REPRESENTATIVE PRI <br />' INSTALLAT <br />ION. <br />G] I, , <br />x ' <br />1 "GAS <br />1 "GAS <br />90 CFH <br />216 CFH <br />I I <br />RTU-A <br />125CFH L----J <br />I � <br />�f <br />1 FLOOR PLAN - GAS <br />P-2 SCALE: yr = r-0" <br />SPECIAL EQUIPMENT NOTE: <br />CONTRACTOR TO REFER TO RESTAURANT <br />EQUIPMENT CUT SHEETS AND SCHEDULES FOR <br />COORDINATION WITH ALL INSTALLATIONS WITH <br />EQUIPMENT SUPPLIERS, KITCHEN DESIGNER, <br />AND FIVE GUYS, INC. <br />DRAIN LINE <br />2 x "D" <br />(MIN. 1" CLEARANCE) <br />NOTE: <br />USE AIR GAP DETAIL FOR ALL EQUIPMENT DRAINING TO <br />HUB DRAINS & FLOOR SINKS ON THE FRESH AIR SYSTEM. <br />6 AIR GAP DETAIL <br />P-2 J SCALE: NONE <br />NOTES: <br />1. PIPE BATTEN REQUIRED WHEN THIS DETAIL IS USED ON MECHANICALLY <br />ANCHORED SYSTEMS. <br />2. REMOVE ALL EXISTING FLASHINGS, LEADS ETC. PIPE SURFACE MUST BE FREE <br />OF ALL RUST, GREASE, ETC. <br />3. PIPE MUST BE ANCHORED TO BOTTOM SIDE OF DECK TO ASSURE STABILITY. <br />4. INSTALL PER ROOFING MANUFACTURER'S RECOMMENDATIONS. <br />2 VENT THR-U ROOF DETAIL <br />P-2 SCALE: NONE <br />GAS SUPPLY � I �— <br />GAS COCK G <br />y` UNION <br />DIRT LEG <br />FULL SIZE PRESSUF <br />TEMP RELIEF VALVE <br />DRAIN VALVE WITH HO <br />PLUMBING LEGEND <br />SYMBOLS & ABBREV <br />LEGEND <br />SOIL /WASTE PIPING BELOW FLOOR <br />- - - - - - - - <br />VENT PIPING <br />G <br />GAS PIPING <br />C.W. - <br />COLD WATER SUPPLY <br />H.W. - - <br />HOT WATER SUPPLY <br />--0 --o <br />PIPE RISING - PIPE TURNING DOWN <br />B.V. 101BALL <br />VALVE <br />PRV rS <br />PRESSURE REDUCING VALVE <br />---+IE---- <br />UNION <br />N.F.W.H. -}- <br />NON -FREEZE WALL HYDRANT <br />CO In <br />FLOOR CLEANOUT <br />F.D. 30 <br />FLOOR DRAIN <br />B.F. <br />BELOW FLOOR <br />A.C. <br />ABOVE CEILING <br />VTR <br />VENT THRU ROOF <br />AFF <br />ABOVE FINISHED FLOOR <br />INV <br />INVERT <br />BFP <br />BACK FLOW PREVENTER <br />ATION <br />E <br />END CONNECTION il"' t_BVV `—DRAIN VALVE WITH HOSE <br />BV END CONNECTION <br />WH-A NORITZ MODEL N-0931M-DV-ASME OR EQUAL. <br />NOTE: CONTRACTOR TO PROVIDE BELL & GOSSETT MODEL #NBF-22U RECIRCULATING <br />PUMP WITH MINIMUM FLOW OF 2 GPM, AQUASTAT TEMPERATURE SENSOR, AND TIMER. <br />ROOFTOP <br />UNIT <br />GAS TANKLESS WATER HEATER <br />SCALE: NONE <br />GAS PIPING CONNECTION DETAIL <br />SCALE NONE <br />PLUMBING NOTES. <br />1 THE INSTALLATION SHALL INCLUDE ALL NECESSARY APPARATUS, <br />EXCAVATING, CONTROLS, VALVES, AND FITTINGS AS NECESSARY TO <br />MAKE THE PLUMBING INSTALLATION COMPLETE. <br />2 CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, <br />CONNECTION AND INSPECTION FEES REQUIRED FOR THE CONPLETE <br />INSTALLATION OF THIS WORK. HE SHALL DELIVER TO THE ARCHITECT <br />ALL CERTIFICATES OR SAID INSPECTION ISSUED BY THE AUTHORITES <br />HAVING JURISDICTION. <br />3 THE PLUMBING SYSTEM SHALL BE TESTED AS REQUIRED BY THE <br />2006 UPC. <br />4 PLUMBING FIXTURES: PROVIDE PLUMBING FIXTURES COMPLETE WITH <br />TRIM. ALL FIXTURES, TRIMMINGS AND STOPS SHALL BE GRADE "A" <br />AND SHALL BE OF ONE MANUFACTURER. PLUMBING FIXTURES FOR USE <br />BY HANDICAPPED PERSONS SHALL BE IN ACCORDANCE WITH <br />ACCESSIBILITY REQUIREMENTS. FIXTURES AS SCHEDULED ON DRAWINGS <br />OR APPROVED EQUALS. GROUT BETWEEN PLUMBING FIXTURES AND <br />WALLS AND/OR FLOORS. FOR CONNECTION OF FLOOR -OUTLET WATER <br />CLOSETS, BRASS FLOOR FLANGES SHALL BE USED. THE JOINTS <br />BETWEEN CLOSETS TRAP AND FLANGE SHALL BE MADE TIGHT WITH <br />GASKETS. CONNECTION OF FIXTURE TRAPS FROM LAVATORIES, <br />DRINKING FOUNTAINS, SERVICE SINKS, ETC. TO CAST IRON SHALL BE <br />MAKE WITH D.W.V. TYPE COPPER. CONTRACTOR SHALL SEAL, USING <br />SEALANT MEETING REQUIREMENTS OF FEDERAL SPECIFICATION <br />TT-S-230, JOINT BETWEEN URINAL AND WALL AND AT WATER CLOSET <br />AND FLOOR. <br />5 FLOOR DRAINS SHALL BE SET WITH TOP FLUSH WITH FINISH FLOOR. <br />6 WATER PIPING SHALL BE TYPE "L" COPPER WITH COPPER FITTING <br />AND HANGERS. CONTRACTOR MAY SUBSTITUTE PVC IF APPROVED <br />BY LOCAL CODE OFFICIALS. IT IS THE CONTRACTORS RESPONSIBILITY <br />TO GET APPROVAL FOR THE USE OF PVC. <br />7 SOIL WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT CAST <br />IRON WITH LEAD AND OAKUM OR MECHANICAL JOINTS AS APPROVED <br />BY THE LOCAL CODE OFFICIALS: USE PVC (SCHEDULE 40) WHERE <br />APPROVED BY CODE. <br />6 INSULATE ALL WATER LINES WITH 1" OWENS CORNING SSLA 1. ALL <br />FITTINGS SHALL BE INSULATED AND COVERED WITH PVC COVERS. <br />9 INSULATED HANDICAPPED LAVATORIES WATER & DRAINS LINES <br />W/TUBRO HANDI-LAV-GUARD KITS. <br />10 PROVIDE ESCUTHEON PLATES WHERE PIPES PENETRATE WALLS <br />THAT ARE EXPOSED. CAULK AND SEAL ALL PIPE SELEVES. <br />11 CLEANOUTS SHALL BE PROVIDED WHERE REQUIRED BY THE APPLICABLE <br />PLUMBING CODE. CLEANOUTS IN CAST IRON SOIL PIPELINES SHALL CONSIST OF <br />CAST IRON FERRULE AND HEAVY BRASS CLEANOUT PLUG WITH SQUARE HEAD. <br />WHERE PIPING IS CONCEALED IN FLOORS OR WALLS, CLEANOUTS SHALL BE <br />INSTALLED IN AND NEAR SURFACE OF FLOORS OR WALLS AND SHALL HAVE <br />COUNTER SUNK PLUGS AND COVERS. <br />12 CLEANOUTS FOR FLOORS SHALL BE JOSAM MANUFACTURING COMPANY'S <br />SERIES 58000 WITH INSIDE CAULK OUTLET COATED CAST IRON INTERNAL <br />CLEANOUT WITH LEAD SEAL, BRASS RIM AND INKALOY SCORIATED COVER PLATE <br />FOR LIGHT TRAFFIC SECURED TO PLUG BY COUNTERSUNK SCREW FOR <br />INSTALLATION FLUSH WITH FINISHED FLOOR COMPLETE WITH CARPET MAKER IN <br />CARPETED AREAS. <br />13 CLEANOUTS IN WALLS, JOSAM MANUFACTURING COMPANY'S SERIES 58710 WITH <br />STAINLESS STEEL COVERS. EQUAL CLEANOUTS MANUFACTURED BY ZURN OR J.R. <br />SMITH ARE ACCEPTABLE. <br />14 GENERAL: MAKE CONNECTIONS TO ALL FIXTURES, TRAPS AND SIMLAR ITEMS. <br />CONTRACTOR SHALL PLACE INTO OPERATION ALL EQUIPMENT. ARCHITECTURAL <br />DRAWINGS SHALL BE REFERRED TO FOR EXACT LOCATION ALL FIXTURES AND <br />DRAINS. ROUGHING DIMENSIONS SHALL BE DETERMINED FROM THE <br />MANUFACTURER OF THE EQUIPMENT FURNISHED ON THE JOB. <br />15 SUBMIT 7 SETS OF SUBMITTAL ON ALL FIXTURES INSULATION & EQUIPMENT FOR <br />APPROVAL BEFORE PLACING ORDER FOR EQUIPMENT. <br />INSTALL ALL EQUIPMENT AND FIXTURES ACCORDING TO MANUFACTURERS <br />RECOMMENDATIONS. WARRANTY SHALL BE 1 YEAR ON ALL EQUIPMENT AND <br />WORKMANSHIP, EXCEPT 3 YEARS ON WATER HEATER TANK. <br />16. ALL SANITARY PIPING LOCATED IN FIRE RATED WALL SHALL BE CAST IRON OR <br />COPPER. COORDINATE LOCATIONS WITH ARCHITECT. <br />17. ALL SANITARY AND VENT PIPING LOCATED IN RETURN AIR PLENUM SHALL BE <br />CAST IRON. COORDINATE LOCATIONS WITH MECHANICAL DRAWINGS. <br />18. POTABLE WATER SYSTEMS SHALL BE DISINFECTED PRIOR TO USE. THE METHOD <br />TO BE FOLLWED SHALL BE THAT PRESCRIBED BY THE LOCAL HEALTH DEPT. <br />TRACY M. WOODALL, P.E. <br />181 Sedgefield Overlook <br />Dallas, Georgia 30157 <br />T: (678) 642-7282 Florida PE <br />F: (770) 406-2381 #56620 <br />ERIC J. SAFFRAN <br />ARCHITECT <br />Preston Ridge Commons <br />3155 North Point Parkway <br />Building E - Suite 200 <br />Alpharetta, Georgia 30005 <br />Tel 770 619 5916 <br />Fax 770 619 5919 <br />M W06 <br />No <br />If <br />"'till to <br />oC <br />F VIP <br />w <br />Z <br />w <br />UQ� <br />� M <br />(L <br />CL <br />O cC <br />En OO <br />OQ <br />04 <br />Lh <br />Ona <br />N <br />a <br />N <br />WL; W <br />REVISIONS <br />NO. <br />DATE <br />REVISION <br />EMNIFICATION CLAUSE <br />NER SHALL RELEASE, HOLD <br />SS, AND INDEMNIFY THE <br />rASPECTOF <br />CT WITH RESPECT TO: ANY <br />S MADE TO THE CONSTRUCTION <br />ENTS BY ANYONE OTHER THA <br />CHITECT, OR CHANGES IN ANY <br />OF THE WORK, OR FAILURE BY <br />NTRACTOR TO BUILD IN <br />ANCE WITH THESE <br />UCTION DOCUMENTS <br />OPYRIGHT 2010 <br />J. SAFFRAN, ARCHITECT <br />AWING IS THE PROPERTY OF <br />FFRAN, ARCHITECT <br />FANDJiSNOT <br />OT TO BE REPRODUCED OR <br />IN WHOLE OR IN PART. <br />ORIZED USE OF ANY KIND, <br />NG USE ON ANY OTHER <br />IS PROHIBITED. IT IS TO BE <br />D UPON REQUEST. <br />ESHEETAN, NOTES <br />ETAILS <br />SECT <br />SHEET NO. <br />O <br />1030 <br />DRAWN <br />BY <br />TMW <br />P�2 <br />DATE <br />1 1-23-10 <br />2 OF 3 <br />