My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
33984 Morse Willow Ct
Zephyrhills
>
Building Department
>
Building Plans
>
33984 Morse Willow Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 5:19:36 PM
Creation date
2/24/2025 9:41:30 AM
Metadata
Fields
Template:
Building Plans
Street #
33984
Location
Morse Willow Ct
Contractor
D R Horton
Building Plans - Permit #
2585
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC IN EDITION (2020) MECHANICAL SLOG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />0. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />COINTERSUN K <br />C.O. PLUG <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3AWX2' TAPCONS� UNIT �SIMPSON WB ROLL STRAP <br />OR EQUAL FIN. GRADE <br />OR PAVING <br />4' CONCRETE SLAB —SECURE STRAP TO UNIT W/ (2) <br />@SXI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />19 <br />PASS-THRJ AIR GRILL <br />SEE SPEC. <br />1'-S'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN -OUT (TYPN) <br />ALL H AVAC TO HAVE PROPER <br />ENTRY <br />PANS W/ DRAINS <br />ENTRY <br />ATTIC <br />CEILING <br />SCORIATED NICKEL <br />FIN. FLOOR <br />O <br />O <br />EXTERIOR WALL <br />BRONZE FL. PL. <br />OR WALL <br />PLENUMIRETURN <br />AIR RETURN <br />• o 00 <br />O <br />SUCTION AND LIQUID <br />0 <br />AIR SUPPLY <br />REFRIGERANT LINES <br />BRASS PLUG <br />AIR HANDLEREXTERIOR <br />WALL <br />FITTING OR EXTENSION TO <br />C] Loil <br />3/4'PVC CONDENSATE DRAIN LINE <br />SOIL OR WASTE AS <br />REQUIRED <br />EVAP.TRAY <br />PVC SLEEVE TO LINES BELOW SLAB <br />WADE 8240-K JOSAM 56000 <br />REFRIGERANT LINES TO <br />INSIDE <br />SERIES NICKEL BRASS TOP <br />PLATFORM <br />CONDENSING UNIT <br />CAULK <br />P.V.0 OPTI/SPEC <br />TRAP DRAIN LINE AND TERMINATE <br />FIRST FLOOR <br />DRAIN, AS PER <br />IN AN ITH EDITION <br />FBCR 1TH EDITION (2020) <br />INV. SEE <br />MECHANICAL P LA N <br />MECHANICAL BLDG. CODE <br />SITE PLAN <br />SECTION 301.2A <br />SCALE. 1/4'•I'-0' <br />HVAC <br />DRAINS <br />(I)FLOOR SLAB <br />CLEAN -OUT (TYP.T) <br />A R C N I T I C T <br />6 <br />GrouOLn. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407.774.6078 <br />FAX: 407-774-4078 <br />ww Zbd—group.com <br />AAol#:.003325 <br />IF DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813E86.2626 <br />FAX: $13-886-2802 <br />Iiiiiiiiii'l <br />IIIIIN119 <br />aVHDIV. & L.OT <br />SILVERADO <br />LOT #15 <br />BLK #16 <br />PROJECT# <br />03719.001-15161 <br />MODELc <br />3278—JORDYN II <br />GARAGE SWING: <br />RIGHT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />LAN <br />15 H E C <br />