My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35844 Morse Willow Ct
Zephyrhills
>
Building Department
>
Building Plans
>
35844 Morse Willow Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 5:27:00 PM
Creation date
2/24/2025 9:46:34 AM
Metadata
Fields
Template:
Building Plans
Street #
35844
Location
Morse Willow Ct
Contractor
D R Horton
Building Plans - Permit #
1652
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS 614ALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING, ALL SEAMS SHALL BE SEALED WITH GLASS FAB A MASTIC. AND <br />INSTALLED AS PER FDC 1TH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, Syam BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FOC 1TH EDITION <br />(2020) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOVERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL. HAVE AN APPROVED FIRE OR FIRE/8MOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR ODD <br />Q <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />m <br />THERMOSTAT <br />IM <br />PASS-THR.1 AIR GRILL <br />SCORIATED NICKEL /-FIN. FLOOR <br />BRONZE FL. PL. / OR WALL <br />BRASS PLUG <br />-'�-FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />INSIDE SERIES NICKEL RASS T BOP <br />CAULK P.V.0 OPTI/SPEC <br />vFL00R SLAB CLEAN -OUT (TYPN) <br />COWTERSUN< <br />CA. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-8'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />vEXT. GROUND CLEAN -OUT (TYPN) <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/16'X2' TAF'CONS UNIT SIMF'80N U16 ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />#SXI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />ATTIC <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />i <br />I '^' <br />O <br />EXTERIOR WALL <br />- - -w <br />EllPLENUM <br />AIR RETURN <br />Ell <br />�e <br />SUCTION AND LIQUID <br />-- <br />�iY <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />6XI0 '�� <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />mI <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />BEDROOM 4 <br />� <br />I <br />BEDROOM 3 <br />EVAP. TRAY <br />yx� <br />PVC SLEEVE TO LINES BELOW SLAB <br />1 <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDEN8ING WIT <br />PpN. <br />TRAP INLINE AND TERMINATE <br />IN AN AFROVED DRAIN, AS PER <br />EDITION l2020) <br />—01 <br />MECHANICAL DLDG. CODE <br />LilSECTION <br />301Z.4 <br />HVAC <br />DRAINS <br />MECHANICAL PLAN <br />SCALE, 1/4' " I'-0' <br />aysDIV. & LOT <br />SILVERADO <br />LOT #23 <br />BLK #13 <br />PROJECT <br />03719.00t-23131 <br />MOaEIa <br />"2558-HAVTHORNE" <br />GARAGE 8WDgG: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />