Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHNG OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FL.484INS, TO BE, <br />L BOTTOM, 2. SIDES, 3. TOP <br />VENT CAP 18 TO BE SET N BED <br />OF SEALANT AT TOP AND <br />BIDES ONLY. SEALANT 18 TO BE <br />' <br />TOOLED 80 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT-APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />1 <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDEB,4 CAING ULK• JOINT <br />I <br />I <br />ALL AROUND <br />I I <br />PER SECTION R708.7 <br />ExMlor lathing WnW p�s[aklG <br />BACKER ROD <br />I <br />Exterior use of pordand cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />X. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />_,._ <br />or ASTM 1787. <br />WRB LAYER 9, <br />.. �. <br />n X. <br />STUCCO WRAP <br />'- - <br />HOODED VENT <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />WOOD SHEATHING <br />LAYER M, <br />STUCCO WRAP <br />LAYER 4, FORTIFIBER <br />15UILDNG PAPER <br />ulooD <br />CONBTUCTION <br />�t <br />{ <br />b' WDE STRIP KELP <br />ADNE3IVE PLABHNM CLEAN <br />MASONRY BEFORE APPLYING <br />Z PLAS14M <br />STOW <br />Y04 M <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCKZ <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER "2 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16° ZIP WALL <br />5HEATHING <br />SELF-ADHESIVE FLASHING — — — — NOTE - <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-84-1-14a, MIN. 2B LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUR DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />9 DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE TMODUGH <br />U1f1LL <br />I <br />6' SELF ADHESIVE— <br />FLASHINCs (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METEf <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />G -('REAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER N, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />J' THICK 3 COAT CEMENT <br />PLASTER <br />Rj7 <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOU.ISEWRAP <br />FOR BOX INSTALLATION <br />WR5 LAYER e1, <br />STUCCO WRAP <br />WOOD SHEATHING <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D'R FELT-POVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEATHING <br />WINS LAYER q, <br />STUCCO WRAP <br />BJRB LAYER -2. FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRUCTURAL <br />FEMBEER • T' OG MAX <br />V TO fi' MID-UWLL <br />DEEP B[XiEED <br />�G <br />W WOE STRIP SELFHNG, ADHESIVE FLA8CLEAN <br />MASONRY DEFORE APPLYING <br />V FNMN • MA5CNRT <br />(�oHORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />S' <br />WIRE, LAYER 01, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF-ADHERNG <br />—may MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WLAYER M RB <br />STEP #1 STEP #2 <br />STEP *3 <br />B WRLAYER M, <br />STUCCO WRAP <br />9 APPLY 60 MIN SELF-ADHERNG <br />GRADE 'D' FELT 0MEMBRANE F-A514H4G <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />UIRB LAYER 92, FORTIFIBER <br />BUILDING PAPER <br />STEW *4 <br />&METAL <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ CV. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />LATH <br />STEP 05 STEP Oro(9) ELECTRICAL RECEPTACLE <br />Groin <br />41 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngrouP can <br />AA A: 0003325 <br />IF DRAFRNG BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 8134IM2628 <br />FAX: 813418E-2802 <br />BUDDIV. ae LOT: <br />SILVERADO <br />LOT# 1 <br />BLK# 16 <br />PROJECT#I <br />03719.000-01161 <br />MODEL <br />2795—CAMDEN <br />GARAGE SwfWG: <br />RIGHT <br />Pwcs WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH E . B <br />N <br />F'DARIM03/24/21: 1/4"=1'-0"A2 <br />