FOR ASPHALT SHINGLE ROOF, USE MIN 7/16' STRUCTURAL
<br />SHEATHING EXP 1(24/16) or 1507STRUCTURAL SHEATHING EXP 1
<br />(32/16), FOR CEMENTITIOUS TILE AND METAL ROOFING, USE 15/32'
<br />STRUCTURAL SHEATHING EXP 1(32/16) .(SEE TABLE FOR FIELD AND
<br />EDGE SPACING) SEE DETAIL
<br />ROOF SHEATHING TO GABLE END FRAME USE SO RING SHANK GUN
<br />NAILS G 4" O.C. EDGEWISE 2A BLOCKING ALL PANEL JOINTS W/ IN 4'
<br />OF GABLE END.
<br />SHEATHING
<br />FASTENER SCHEDULE
<br />NAIL REQUIREMENTS
<br />SIZE
<br />HEAD
<br />LENGTH
<br />DIA
<br />TENSILE STR.
<br />SHANK
<br />ASTM
<br />Sd
<br />RING SHANK
<br />230
<br />0.113
<br />170,000
<br />RING
<br />(16-20 RINGS
<br />F1667
<br />RSRS-01
<br />SCREW SHANK
<br />PER INCH)
<br />8d
<br />RING SHANK
<br />PNEUMATIC
<br />23/8"
<br />0.113
<br />F1667
<br />SCREW -NAILS
<br />RSRS-01
<br />EXTERIOR SHEATHING
<br />USE 12' CDX OR 7/16" O.S.B. PLY WITH 8d RING SHANK GUN NAILS AT
<br />4" O.C. AT PANEL SIDES AND 8d RING SHANK GUN NAILS V O.C. TOP &
<br />BOTTOM PANEL AND 8d RING SHANK GUN NAILS AT 6' O.C. AT
<br />INTERMEDIATE SUPPORTS OR 7/16" ZIP SHEATHING SYSTEM
<br />(INSTALLED PER MANUF. SPECS.) SEE DETAIL
<br />ZONE 1: Sd NAILS G 4" O.C. ON EDGE AND 6' O.C. IN FIELD
<br />ZONE 2e, 2A, 2r Sd NAILS 4" O.C. ON EDGE AND 4" O.C. IN FIELD
<br />ZONE 3,3e, 3T 8d NAILS G 4" O-C. ON EDGE AND 4" O.C. IN FIELD
<br />NOTE: ROOF SHEATHING THICKNESS WAS CALCULATED
<br />AND ADHERES TO ASCE 7-16
<br />Sd RING SHANK GUN NAILS G 4" O.C.
<br />TOP & BOTTOM EDGES
<br />V .
<br />TYP. EXT. SHEATHING ATTACHMENT
<br />a
<br />Z,
<br />W
<br />zo
<br />oW
<br />Y®
<br />iU
<br />N Q
<br />z�
<br />RAFTER OR TRUSS—�
<br />ROOF SHEATHING —�
<br />Emmmm
<br />mmmmmm011
<br />��� 11
<br />Emm
<br />BUILDING LENGTH
<br />ROOF SHEATHING LAYOUT
<br />AND ENDWALL BRACING
<br />FOR GABLE END FRAMING
<br />NOTE: GABLES -DROP GABLE END & (1) ADD'L DROPPED
<br />TRUSS 2X4 #2 SYP OUTLOOKER RAFTER W/ BLOCKING a
<br />16'O.C. IF NO DROPPED GABLE END, ATTACH 2K4 #2 SYP
<br />BLOCKING G 16" O.C. FIRST 4 BAYS W/ (2)12d NAILS EA
<br />END. ATTACH ROOF SHEATHING TO RAFTERS 2/
<br />BLOCKING PER NAILING SCHEDULE
<br />8d RING SHANK GUN NAILS
<br />SEE "ROOF SHEATHING ATTACHMENT'
<br />TABLE FOR FIELD SPACING \
<br />C#S 2' DECK SCREWS ® 6'-8" O.C. MAX
<br />EDGES & 12" O.C. MAX IN FIELD. UNTHREADED
<br />SHANK TO EXTEND BEYOND THICKNESS OF
<br />SUB -FLOOR SHEATHING
<br />TYP. 3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS
<br />HIP ROOF a, A >�
<br />FASTENER SCHEDULE
<br />1MNDOW AND
<br />DOOR BUCK
<br />FASTENERS
<br />FASTENER
<br />APPlIG110N
<br />812E
<br />TYPE
<br />eEMMxe
<br />APRIDRII(x1
<br />elg
<br />ePPGNp
<br />REMPRI(8
<br />: PTFumaND rD
<br />MAsceavlwNe.
<br />cieE HxxDEra:onaL
<br />NwL11rrLaexi.
<br />roc
<br />oanAOE DOOR slat
<br />TO MAswmeoND
<br />ur IXA
<br />No wA4lae
<br />rAPwN 4A80NRY
<br />FAs1ENHt
<br />°"�
<br />11rr E4eEd, a•onlxsr.,
<br />1121nc as
<br />9DD, AL. FxT.wCiiB
<br />CiBE FMADEI�OdI
<br />I
<br />WINDDw'4)DOfMFPeTENED
<br />DARADE DDgi BtIG(
<br />�•��
<br />1CaC (°/CdA)
<br />rEM°ED.1"ENDgBT.,
<br />NAR11?IANG.
<br />T
<br />STAOOF1iED
<br />I--
<br />To-
<br />M1WA91�Ht
<br />IXPANSIDNBDLT
<br />b'OICIf?DWI
<br />SEDDE dBT.
<br />CASE N.HOErmcaL
<br />sac
<br />N1N]DV°DOOP/FABTQlED
<br />4Eru siRAnro
<br />CONTACT THIS ENGINEER FOR SPACING
<br />Ix PT.9EESEEIEe
<br />NAIL1tn LORD.
<br />srAC�JERFD
<br />INro 4A�MrIJJNC
<br />MABOIJE'f 1Cd1C.
<br />REQUIREMENTS
<br />EM. SrA40 wd2
<br />BUaf 9, Pr, BEE NOlE6
<br />13)YtedA
<br />ND WASHER
<br />TAPODN'
<br />FABTNER
<br />18"�
<br />tt?E4BE4rgU
<br />g8T..11/Y EDGE DRi.
<br />NDNBFNaNG WOOD
<br />WALLro CONIC SA9
<br />1? ExPAN90N �•� rEMBFD.rEfO
<br />WI WABHEM BOLT q8T.. 3•®GE dBT.
<br />Pi TOT WINDOW MIG( 0.13°'PPFx3llB• p'QC A'END. a8T.,111Y
<br />8TFEL Wl,Sff ,µWI cNER BTAGOBtED EDOE018T.
<br />NOTES
<br />NOTES
<br />1. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS
<br />2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURERS SPECS AND / OR NON
<br />3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED
<br />4. PAF SHALL BE HILTI X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN
<br />5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE
<br />e. WINDOW AND DOOR BUCKS SHALL BE AS NUDE OR W DER AS THE DOOR OR WINDOW FRAME EXCEPT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. Ix MEMBERS ARE NAILED AND
<br />2x MEMBERS ARE SECURED W TAPCONS OR PAF TO THE SUBSTRATE.
<br />GENERAL NOTES:
<br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTMC33HC33M MAXIMUM AGGREGATE SIZE SHALLBE 3M.
<br />STRUCTURAL DRAWINGS SWILL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND
<br />�-
<br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT
<br />PROVIDE 6%NRENTRANED CONCRETE EXPOSED TO EARTH OR WEATHER
<br />NON -BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF.
<br />ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN
<br />ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS: FBC-R 2020, 7A EDITION
<br />ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAAFERED 3W.
<br />ALL VOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING,
<br />ACI 31B-14, BUILDING CODE REQUIREMENTS
<br />CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO. 2 OR BETTER. Fb = 11DO PSI AND A MODULUS OF
<br />'=
<br />FOR STRUCTURAL CONCRETE, TMS 402802-16 AISI SPECIFICATION FOR THE DESIGN OF
<br />PROVIDE -MIL CONTINUOUS POLYETHYLENE VAPOR BAFRER MEMBRAHJE MJM ALL SLPBSON6ROUND WHERE INDICATED ON
<br />POVIDEDRAWINGS.SEAMS
<br />ELASTICITY 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE
<br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2016, ASCE 7-16 AND AISC SPECIFICATIONSPRESSURE
<br />LAPPED 61NCFES AND SEALED WITH ADHESNETAPE
<br />TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NONSTRUCTURAL USES
<br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND
<br />FORM -WORK:
<br />SHALL BE RATED TO RETENTION LEVELS OF 0.25 PCF OF A BORATE PRESERVATIVE TREATMENT: DISODIUM
<br />CORROBORATE TETRAHEDRAL (DOT). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY
<br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT,
<br />FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS,
<br />REASON SHALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED
<br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN.
<br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH AG 347 LATEST
<br />W DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT
<br />EDTION,"RECOMMENDED PRACTICE FOR CONCRETE FORM -WORK
<br />CONTAINS MORE THAN %" OF HEARTWOOD.
<br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE
<br />DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT
<br />EXCLUSIONS FROM THESE PLANS:
<br />MINIMUM NAILING PER FBCR 2020, 71h EDITION. SEE NAILING SCHEDULE ON PLANS.
<br />TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART
<br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS
<br />OF THE WORK.
<br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURALDEPENDING PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER
<br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS.
<br />SYP #a.
<br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING
<br />IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND
<br />BEDUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS
<br />DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,
<br />TEMPORARY BRACING, GUYS OR TIE -DOWNS
<br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION
<br />REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS.
<br />DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR
<br />TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
<br />DESIGN LOADS:
<br />ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 psf
<br />20 psf TOP CHORD noecmwrreret
<br />10 psf BTM CHORD+wecoewrrwd
<br />WELDED WIRE MESH:
<br />WELDED HARE MESH, SHALL BE ASTM AlM*A7054M, GRADE 65 AND BE PLACED IN ACCORDANCE WTH THE
<br />AG TYPICAL DETAILS, MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL
<br />BE SUPPORTED WITH Y CHAIRS SPACED T-W OC, EACH WAY.
<br />REINFORCING STEEL
<br />REBAR SHALL BE ASTM A81 SA615M GRADE 40 IN CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM A615
<br />GRADE 601N MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN ACCORDANCE
<br />W/ THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS.
<br />CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL
<br />AND VERTICAL BARS SHALL LAP 6 x BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEER'S
<br />REVIEW.
<br />TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25" #6 BAR - 36'
<br />#5 BAR - 30" #7 BAR - 47'
<br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED
<br />AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES.
<br />WOOD TRUSSES:
<br />TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATIONS FOR
<br />STRESS -GRADE LUMBER AND ITS FASTENINGS" BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND
<br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS.
<br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036" AND BE MANUFACTURED FROM STEEL
<br />MEETING THE REQUIREMENTS OF ASTM A446/A446M, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED.
<br />DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14, "DESIGN NATIONAL
<br />STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION%AND "BCSI LATEST EDITION"
<br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED
<br />WOOD TRUSSES.
<br />PROVIDE 36" K 35" CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS
<br />TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF
<br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR
<br />DEAD LOAD
<br />DEAD LOAD
<br />FOR ADDITIONAL INFORMATION.
<br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSVASCE 7 88: 1990.
<br />15 psf TOP CHORD
<br />20 psf TOP CHORD
<br />(7 pef w/ ASPHALT SHINGLES)
<br />psf w/ No GYPCRETE)
<br />ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING,
<br />HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS.
<br />10 BTM CHORD
<br />PST
<br />5 p
<br />5 BTM CHORD
<br />psf
<br />THICKENED SLAB BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH
<br />DEAD LOAD TO RESIST NAND UPLIFT: tOpsf
<br />MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE
<br />CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT
<br />BALCONY LIVE LOAD 60 Psf
<br />STAIRS UVE LOAD 40 psf
<br />Wes'
<br />TRUSSESIGIRDERS TO COLUMNS AND WALLS FOR APPROVAL.
<br />WIND: DEAD LOAD SPEED =150 MPH 3- SECOND GUST
<br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL
<br />ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING
<br />(ASCE 7-16 (FBC R2020) EXPOSURE B, RISK CATEGORY 11)
<br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE.
<br />DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL
<br />LIVE LOADS: UNINHABITABLE ATTIC WITHOUT STORAGE: 10pcf, UNINHABITABLE ATTIC WITH LIMITED
<br />LAYOUT, SPANS 8 ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT
<br />STORAGE: 20psf, HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS: 30psf, BALCOMES (EXTERIOR)
<br />00 HOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS
<br />AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE
<br />AND DECKS: 40psf,, GUARDS AND HANDRAILS: 200psf, GUARD IN -FILL COMPONENTS: 50psf, PASSENGER
<br />AND
<br />WITHOUT THE APPROVAL OF THE ENGINEER.
<br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL
<br />VEHICLE GARAGES: 50psf, OTHER THAN SLEEPING ROOM: 40psf, SLEEPING ROOMS: 30ps1, STAIRS:
<br />PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS ANDA FULLY DIMENSIONED ERECTION
<br />4OPW
<br />MASONRY:
<br />PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA
<br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WTH ALL REQUIREMENTS OF THE
<br />LICENSED PROFESSIONAL ENGINEER.
<br />SHOP DRAWING REVIEW:
<br />"SPECIFICATION MASONRY STRUCTURES" (TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY
<br />SHOP DRAW NGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT
<br />STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS PUBLISHED BY
<br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE
<br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS
<br />OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
<br />THE MASONRY STANDARDS JOINT COMMITTEE.
<br />PROVIDED BY THE TRUSS ENGINEER.
<br />COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC.
<br />ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK
<br />THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE
<br />ALLSHOP DRAW NGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT.
<br />MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE Pm = 2000 PSI. BLOCK SHALL BE PLACED USING
<br />OF THE DELEGATED TRUSS ENGINEER. WIND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-16 COMPONENT
<br />AND CLADDING W ND LOAD PRESSURES, THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR
<br />DRAWINGS SUBMITTED WTHOUT REVEW WILL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM
<br />RUNNING BOND UNLESS OTHERW SE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE
<br />ALL TRUSS TO TRUSS CONNECTIONS.
<br />OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CONTRACT DOCUMENTS) ARE PROHIBITED
<br />PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH
<br />WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER- IN ALL INSTANCES, THE CONTRACT
<br />ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 30M PSI AT 28 DAYS, UNLESS
<br />DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED, UNLESS OTHERWSE SPECIFIED IN
<br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8"
<br />WRITING BY THE ARCHITECT,
<br />COURSE AGGREGATE, AND SHALL BE PLACED W A SLUMP OF 8" TO 10". USE ONLY MECHANICAL MBRATION
<br />TO CONSOLIDATE GROUT.
<br />FOUNDATION/ SITE PREPARATION:
<br />FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 pd. FOOTING
<br />TYPE "M" OR "$" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE
<br />PROPORTIONED AND MIXED AS OUFUNED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS
<br />EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95% OF THE
<br />SHALL BE 31W THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO
<br />MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WTH ASTM D-1557. TREAT ALL
<br />CELLS TO BE FILLED.
<br />SOIL FOR TERMITE PROTECTION.
<br />FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS ANDOR VERTICAL
<br />THE OWNER SHALL RETAIN THE SERMCES OF AN INDEPENDENT CEO -TECHNICAL ENGINEER TO VERIFY
<br />REINFORCING.
<br />SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE
<br />GEO-TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE
<br />LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O.
<br />CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE
<br />MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL
<br />BE MADE BY THE GEO-TECH. ENGINEER.
<br />STRUCTURAL STEEL:
<br />CONCRETE:
<br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS:
<br />2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB-ONGRADE
<br />3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SLAB.
<br />CONTRACTOR SHALL L SUBMIT PROPOSED MIX DESIGNS, MATH HISTORKAL STRENGTH DATA FOR EACH SEPARATE MX PRIOR TO
<br />CONCRETE R ACBIENT. CONCRETE BULB SHALL NDT EXCEED 5' * PRIOR TO THE AMMON OF PLASTICIZER
<br />CONCRETE SMALL COMPLY MTN ALL THE REQUIREMENTS OF ACI 318AND ASTM C940 MOR AEASURNG, AWING. TRANSPORTING,
<br />ETC. CONCRETE TICKETS SMALL BE 71ME-STAMPED WIEN CONCRETE IS BATCHED. THE MAXIMUM THE ALLOWED FROM MIEN
<br />WATER IS ADDED TO THE MIX UNTIL R IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. F FOR ANY REASON
<br />THERE IS A DELAY IN SUCH TEAT A BATCH IS WELD FOR LONGER THAN 90 MNUTES, TIE CONCRETE SHALL NOT BE PLACED. R SHALL
<br />BE THE RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY TIE OWNERS REPRESENTATIVE AND THE CONTRACTOR OF ANY
<br />NON COMPLIANCE WITH THE ABOVE.
<br />A 3• FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS):
<br />B. FOR CONCRETE EXPOSED TO EARTH ANDOR WEATHER
<br />1-171" FOR 05AN) SMALLER
<br />T FOR 06 AND LARGER
<br />C. FOR CONCRETE NOT EXPOSED TO WEATHER
<br />3M FOR SLABS. WALLSAfD JOISTS
<br />14rr FOR BEAM AND COLUA#N P14MARY RBNFOWEME/T, TIES STIRRUPS
<br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WTH THE
<br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS,
<br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM
<br />ASS/A36M, Fy = 36 ksi FOR ANGLES, PLATES, AND WSHAPES. STRUCTURAL TUBING SHALL BE ASTM
<br />A500/A500M, GRADE B, Fy = 46 ksi. STRUCTURAL PIPE SHALL BE ASTM A53/A53M, GRADE B, TYPE E OR S. Fy =
<br />35 ksi. TUBE AND PIPE COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP.
<br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WTH DOUBLE -NUT LEVELING. ALL
<br />OTHER BOLTS SHALL BE ASTM F3125/F3125M BOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS
<br />SHALL BE TIGHTENED IN ACCORDANCE WTH THE TURN -OFF -THE -NUT METHOD.
<br />ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. J43OLTS ARE TO BE STEEL
<br />A N C N I T 1 C T t
<br />6
<br />Gro�u�
<br />1441 N. RONALD REAGAN BLVD.
<br />LONGWOOD, FL 32750
<br />PH: 407-774-6079
<br />FAX: 407-774-4078
<br />wwINAbdesig poupcom
<br />AA R: 0003325 J
<br />DRAFTING BY:
<br />A.B. DESIGN GROUP
<br />DRAFTING INC.
<br />5439 BEAUMONT CENTER BLVD.
<br />SUITE 1004
<br />TAMPA, FLORIDA 33634
<br />PH: 8138862628
<br />FAX: 813888-2802
<br />BUDDIV. ae LOT:
<br />SILVERADO
<br />LOT# 1
<br />BLK# 16
<br />PILOJECT#
<br />03719.000-01161
<br />MODEL.•
<br />2795—CAMDEN
<br />GARAGE 811IMO:
<br />RIGHT
<br />PACE:
<br />DETAILS
<br />150 MPH A B
<br />
|