My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35869 Morse Willow Ct
Zephyrhills
>
Building Department
>
Building Plans
>
35869 Morse Willow Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 5:31:08 PM
Creation date
2/24/2025 9:45:43 AM
Metadata
Fields
Template:
Building Plans
Street #
35869
Location
Morse Willow Ct
Contractor
D R Horton
Building Plans - Permit #
1928
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
m <br />MECHANICAL PLAN <br />SCALE: 1/4 . 1'-0' <br />HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER. CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHA,L.15E GONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 4 MASTIC. AND <br />INSTALLED AS PER FSC 1TH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SWA i NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CH8'INEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, $yALL. SE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBC 1W EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED M ACCORDANCE TO FBC IT14 EDITION <br />(2020) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND. SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED M ACCORDANCE WITH FSC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />% ALL FIRE RATED CEILINGS AND WALLS 814ALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG, RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A FANTECN DBF BOOSTER FAN OR EQUAL. <br />PANTEC44 DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />ATTIC <br />CEILING <br />PLENUM <br />AIR SUPPLY <br />AIR HANDLER <br />EVAR TRAY <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />I�c:_T U2 <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS UY DRAMS <br />EXTERIOR WALL <br />AIR RETURN <br />SUCTION AND LICIUID <br />REFRIGERANT LINES <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRIAYK <br />— <br />BROKEN LIFE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />RCEILING <br />EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO E <br />CONC. <br />W/ (2)-3/*W' TAPCONS CON�ITTNSER 591POON WB ROLL STRAP <br />OR EQUAL <br />SECURE STRAP TO UNIT W/ (2) <br />4' CONCRETE SLAB <br />EXTERIOR WALL 43XI 114' SHT. MIL. SCREWS <br />y 3/4' PVC CONDENSATE DRAM LINE <br />y PVC SLEEVE TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />RETURN CONDENSING UNIT <br />TRAP DRAM LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />POOR 1TH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION _M 1JA <br />HVAC DRAINS <br />FIN. FLOOR <br />OR WALL <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAN COND, DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COINTER5UhI K <br />CO. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />1'-8'X8' CCNC. <br />—�FITTMG OR EXTENSION TO FITTING OR <br />SOIL OR WASTE AS <br />REQUIRED EXTENSION TO SOIL <br />OR WASTE AS <br />WADE 8240-K UOSAM 56000 REQUIRED <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/BPEC <br />ob INV.E INv. SEE <br />817E PL SITE TE PLAN <br />vFLOOR SLAB CLEAN -OUT (TY nEXT. GROUND CLEAN -OUT (TYPN ) <br />A R C N I T R G T 8 <br />6 <br />Groin <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigigroup.com <br />AA#:0003325 J <br />IDESIGN <br />NG BY: <br />LTAMPA, <br />GROUP <br />NG INC. <br />54T CENTER BLVD. <br />1004 <br />RIDA 33634 <br />8&2628 <br />886.2.2 <br />�BIIIIIIIIIJ <br />STJHDIV. & LOT: <br />SILVERADO <br />LOT# 1 <br />BLK# 16 <br />PROJECTIp <br />03719.000-01161 <br />MODEL: <br />2795-CAMDEN <br />GARAGE SKIING: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH IV. B 01 <br />�I <br />J <br />Dw 03/24/21 <br />SCALE: 1/4"=1'—O" <br />SHEET <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.