My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35875 Morse Willow Ct
Zephyrhills
>
Building Department
>
Building Plans
>
35875 Morse Willow Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 5:34:49 PM
Creation date
2/24/2025 9:30:57 AM
Metadata
Fields
Template:
Building Plans
Street #
35875
Location
Morse Willow Ct
Contractor
D R Horton
Building Plans - Permit #
2432
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING, ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC ZTH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT dE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER POO ITH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO PBC ITH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED N ACCORDANCE WITH PBC ITH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS 614ALL HAVE AN APPROVED FIRE OR FfRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MPG. RECOMMENDATIONS AND PBC 1TH <br />EDITION (2020)MECHANICAL CODE SECTION W. <br />W. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPER& <br />IL DRYER BOOSTER TO BE A PANTEOH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />m <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE. RETURN TRUNK <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />MECHANICAL PLAN <br />SCALE. 1/4 . P-0' <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. r OR WALL <br />BRASS PLUG <br />�—FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 560M <br />INSIDE / SERIES NICKEL BRASS TOP <br />CAULK / P.VG OPTIMPEC <br />OFLOOR SLAB CLEAN -OUT (TYPµ) <br />COUNTERSUNK <br />CA. PLUG <br />FIN. GRADE <br />OR PAVING <br />WE SPEC. <br />I'-B'XB' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />rq-�EXT. GROUND CLEAN -OUT TYPN) <br />SECURE STRAP TO CONC <br />W/ (2)-,SA6'X2' TAPCONS CONDENSER <br />SIMPSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />06XI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN C0ND. DRAIN 3/4' PIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />ALTE <br />L NVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING O O EXTERIOR WALL <br />PLENUM T y AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY y REFRIGERANT LINES <br />y <br />AIR HANDLER____EXTERIOR WALL <br />y 3/4' PVC CONDENSATE DRAIN LINE <br />EVAR TRAY y PVC SLEEVE TO LINES BELOW SLAB <br />T REFRIGERANT LINES TO <br />PLATFORM RETURN CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR ITN EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 301.2.4 <br />HVAC DRAINS <br />A E C N I T E C T 8 <br />rou Gse <br />1vn M. nu w MMLIAn nuvu. <br />LONGWOOD, FL32750 <br />PH: 407-7746078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />L AA *: 0003325 <br />0111111 <br />,amm, <br />avHDM & LOT <br />SILVERADO <br />LOT #2 <br />BLK #16 <br />PROJECT# <br />03719.001-02161 <br />MODEL: <br />"2558-HAWTHORNS" <br />GARAGE OWING: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />160 BRH EA B <br />
The URL can be used to link to this page
Your browser does not support the video tag.