Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEC IENCE OF FLASHING TO BE: <br />':,X: <br />I. BOTTOM, 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />�.' <br />. <br />TOOLED SO AS TO DEFLECT <br />I <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />i_..�. <br />VENT -APPLY SEALANT ALL <br />i <br />I Y <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, Yi CAULKING • JOINT <br />I <br />ALL AROUND <br />PER SECTION R703.7 <br />E:dertor lathing and p18GOBding <br />Exterior use of Portland cement plaster <br />BACKER ROD <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />j 1 <br />Installation of exterior lathing and framing <br />1 <br />I , <br />shall comply with ASTM C 1063-19a, <br />or ASTM 1787. <br />WRB LAYER "I, <br />.X•, <br />STUCCO WRAP <br />HOODED VENT <br />i' THICK 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />WOOD 814EATHWO <br />LAYER M, <br />STUCCO WRAP <br />LAYER -2, FORTIFIBER <br />OIJILDING PAPER <br />wcoD <br />cDNaTucrlaN <br />METAL LATH <br />V cm VINYL CAGING BEAD <br />6' RAISED BAND <br />)J' TOY! HID -WALL <br />ICCP P!„CrC!'l <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFOM APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK( <br />LEGEND <br />DRAINAGE PLANE (WR5 <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFI5ER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16" ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO 5E PER SECTION <br />R103.1.1 / ASTM C-841-14a, MIN. 2.5 L55. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />GB DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />l <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANIF. SPECS.) <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER "I, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />Ya' TO Y6' MID -WALL <br />WEEP SCREED <br />�W SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO 5E FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />I- A -- ')R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />:0 SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER 01, <br />STUCCO WRAP <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEATHING <br />00 LAYER -1, <br />STUCCO WRAP <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />1/8' TEXTURED <br />FINISH • WOOD <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • T' O.C. MAX <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />FINISH • MASONRY <br />® HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />STEP #3 <br />S' <br />WRB LAYER *I, <br />STUCCO WRAP <br />WRB LAYER 01, <br />STUCCO WRAP <br />9 APPLY 60 MIN SELF -ADHERING <br />GRADE 'D' FELT MEMBRANE FLASHING <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />Al HOUSEWRAP <br />WRB LAYER "'2, FORTIRBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />_ METAL LATH <br />STEP #r:;, STEP #ro <br />ELECTRICAL RECEPTACLE <br />P"A R C R I T R C T! l <br />6 <br />GrDe I to <br />jT LO ZOD, FL 32750 �• V <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdosigngroup.com <br />L AA B: 0003325 <br />A <br />L4 <br />a <br />euHDIV. Ae LOT <br />SILVERADO <br />LOT# 3 <br />BLK 16 <br />PROJECT# <br />03719.001-03161 <br />MODEL: <br />"2558-HAWTHORNE" <br />GARAGE BVU40: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />15 H EA B <br />