Laserfiche WebLink
PREFORMED CONTROL JOINT� <br />FLMVE OF CONTROL JOINTS Td <br />BE IUIRED TIED TO LATH • 9' <br />Oa MAX (VERTJ. NOTE, DO <br />NOT FASTEN CONTROL JOINT TO <br />WALL EVEN IF STUD EX16TS <br />BEYOND EXCEPT 6TAPLE6 W( <br />6ETEMP <br />1IRO G1 CON R01OIN. <br />DURING INSTALLATION —� <br />FASTENERS TO ISE SPACED <br />• 1' O.G. MAX VERTICALLY <br />J' THICK 3 COAT CEMENT <br />PLASTER <br />WRB LAYER 9, FORTIFIGER <br />BUILDING PAPER <br />APPROVED METAL LATH <br />FASTENED 01' [VERTJ Or— MAX <br />AT SUPPORTS <br />WRB LAYER 9, <br />STUCCO WRAP <br />WOOD SHEATHING <br />WAMIM <br />LATH SHALL <br />15E CONTIWJOUB <br />THROUGH CON <br />JOINTS BUT <br />BE STOPPED A _ <br />TIED AT EACH SIDE. PROVIDE 2X4 BLOOCMG <br />PER ASTM C1063 PLACED PLAT MAX. 6' TO 8' <br />FROMCONTROL JOINT UIFIEN <br />CONTROL JOINT FALLS ON <br />L FASTENERS FOR LATH TO BE NAILS OR\ i / STRUCTURAL STUD <br />STAPLES M COMPLIANCE uV ASTM CIE63 <br />2. MINE TES TO BE (NO. 16) 00418' WRE / <br />3. 5LOCKW. SHOWN MAY OE IN ADDITION \ <br />TO WALL STUDS REQUIRED PER PLAN <br />@1 "Mrr TYPE CONTROL JOINT <br />OLPaLD WIAIaD. M,♦ <br />OMA Wwc. <br />I. A <br />L CREAM . M. O <br />a CRAM • M.O <br />O,TOLD WURo. M.♦ <br />X CREAM • M.0 <br />FOLD <br />• 4Y <br />® L POLO WIMP • M. A <br />1 CRWE•M.a <br />a CREAM • M. C <br />d POLO M. CP M. <br />O HILL M. c Tar(" <br />OOTTOI PLANaE <br />NIR <br />-.—T— <br />MAL POW 1212 <br />"a CUR. <br />J' THICK 3 COAT CEMENT <br />PLASTER (PR"A VP 2 COAT <br />CO -ENT PLASTER (aw <br />MW LAYER 9, PORTFIIBER <br />BUILDING PAPER nwAME ONLY) <br />WRB LAYER L <br />STUCCO WRA awm OLT) <br />LAP LAYEI! M EUILDNE EEu1• <br />OAR NAILNa PLANW STOP <br />`FRAME OR cm <br />PLAaaNa rEM <br />bk2ML WTALL <br />R.ASHN6 AT 00170M OF FWW a <br />"LL NTERECTIAM <br />NOTE. <br />APPROVED BUILDING WRAP <br />SMALL ISE LAPPED A MINIMUM OF <br />6' R VERTICAL LAPS (ROLL <br />ENDS) A 6' • HORIZONTAL LAPS. <br />ALL SEAMS NEED TO ISE TAPED <br />WTH FORTIBER SHEATHM TAPE <br />/ I' MN LAP • FETAL LATH \ <br />LATH VERTICAL LAP TO BE I' <br />^ .—r METAL LATH <br />I <br />WRB LAYER M, I <br />STUCCO WRAP <br />' MN R LAP ONLY / I WRD LAYER 9, FORI RISER/ <br />BUILDING PAPER I <br />2 SCALE, I IQ'd'-0' <br />J' THICK 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />URB LAYER R. FORTIFISER <br />BUILDING PAPER <br />WOOD SHEATHING <br />, — <br />LAP, 4' PIER <br />ALL LAP <br />VERTICAL LATH <br />& PAPER DETAIL <br />wooD eruD6 <br />NOTE, <br />SHEATHING <br />SIDE LAPS OF METAL <br />PLASTER BASES SHALL <br />BE SEGUED TO <br />BUILDING <br />PRAMING MIMBERS. <br />PAPER <br />THEY SHALL BE TIED <br />BETU.EBN SUPPORTS <br />WTH 00418-M. (131-MM) <br />STUCCO <br />X' <br />WR= AT INTERVALS NOT <br />MORE THAN 9' (229-MHz <br />AS PER ASTM C1063. <br />® KI C KO U T <br />P REPAIR OF TEARS, <br />M ",RIB LAYERS, TEA"' <br />DETAIL <br />MAY BE PATCHED <br />WRNOU6E WRAP TAPE <br />PER MANU°. SPEC, OR <br />PEEL 4 STICK <br />m <br />:[•7�V�L•ww�F1T:��lrrv�i.i <br />REQUIRED TO SECURE <br />PIPE/ WRE TO FRAMMG <br />WRB LAYER 1 <br />STUCCO EIIRAP <br />WRB LAYER -2. FORTFIBER <br />WILDING PAPER <br />METAL LATH <br />6'x6' &W-ADNERINfi ME'1BRANE <br />PLA6FIMG OVER 4'x4' <br />SELF -ADHERING MEMBRANE <br />FILAS14MO OVER APPROVED <br />HOUSE WRAP. <br />4'x4' SELF -ADHERING MEMBRANE <br />FLASHING OVER APPROVED <br />HOUSE WRAP. <br />PLASHING TO EXTEND ONTO PIPE <br />W CONT. BEAD OF SEALANT <br />INSTALL APPROVED HOU64WRAP AIR <br />INFILTRATION BARRIER OVER <br />SHEATHING <br />ELASTO IRRC COATING OVER 6TUCC0/ <br />C.V. PMIBM [SEE TYP WALL SECTION) <br />SECTION <br />ElaerbT SUM an U W Extanor use of p m dealer <br />ahaq comply ro0* sd acam•pplication <br />regolremPMt of f ASTC 928-18. <br />Ubblladon o(axtono, Iathina and framing <br />shell comply Oth ASTM C 1083-19a, <br />or ASTM 1787. <br />4'x4' SELF-ADHERNG MEMBRANE <br />FLASHING (COMPATIBLE W( HOUSE <br />OVER <br />WRAP MATERIALdDHOUSE OVER <br />APPROVED MOUSE WRAP. <br />I' OR LEGG P41-E <br />CUT AND OVERLAP ONE SIDE OF — <br />SELF -ADHERING MEMBRANE <br />PLA8HMG <br />STEP 01 <br />WOOD SHEATHING <br />OR CMU <br />WR5 LAYER 01, <br />STUCCO WRAP (FRAME ONLY) <br />J' THICK, 3 COAT CEMENT <br />PLASTER (FRAME), 1/2' 2 COAT <br />CEMENT PLASTER (CMU) <br />METAL LATH (FRAME ONLY) <br />LAP WIRE, 4 TAPE OVER <br />ROOF/WALL SCREED <br />5'X5' 'L' TYPE CONTINUOUS <br />L Z —GALV. METAL FLASHING <br />MAIL TO ROOF DECK, NOT <br />WALL SHEATHING) <br />CAP SHINGLE - DO NOT NAIL, <br />INSTALL WITH ROOF CEMENT <br />ROOF PER ELEVATIONS <br />O"L" FLASHING <br />N.T.S. <br />W.� <br />11"0 2t7AITTI <br />LEGEND <br />WRAP MATERIAL) OVER 4'x4' <br />SELF -ADHERING MEMBRANE <br />FLASHING OVER APPROVED <br />NOUN WRAP. <br />FLASHING TO EXTEND OMO PIPE <br />CUT AND ovERLAP ONE SIDE OF <br />SELF-ADMBRUYs MIBMIBIRANE <br />FLASHING <br />1 <br />DRAINAGE PLANE (WRB <br />LAYER *11, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO L. <br />WOOD OR 1/16" ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — — <br />NOTE - <br />METAL LATH- LATH TO BE PER SECTION <br />R'103.1.1 / ASTM C-841-14a, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL 32750 <br />PH: 407-774.6078 <br />FAX 407-7744078 <br />www.abdosigngroup.com <br />AA 0: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813N388.2828 <br />FAX: 813$86.2802 <br />