My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35908 Morse Willow Ct
Zephyrhills
>
Building Department
>
Building Plans
>
35908 Morse Willow Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 5:44:55 PM
Creation date
2/24/2025 9:59:38 AM
Metadata
Fields
Template:
Building Plans
Street #
35908
Location
Morse Willlow Ct
Contractor
D R Horton
Building Plans - Permit #
2756
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LEGEND <br />DESCRIPTION <br />DARD SWITCH <br />Y SWITCH <br />Y SWITCH <br />ER SWITCH <br />BUTTON <br />J <br />ON4ECT <br />MOSTAT <br />LE RECEPTACLE (125V/20-AMP <br />EPOLE) <br />DUPLEX RECEPTACLE <br />DUPLEX RECEPTACLE (EQUIPPED <br />GROUND FAULT <br />NTERUPTER/TAMPER RESISTANT TYPE) <br />10V DUPLEX OUTLET (HALF OF OUTLET <br />(RED TO SWITCH) <br />40: <br />EXTERIOR WATEM ROOF/GFI <br />RECEPTACLE (GROUND FAULT <br />NTERUPTER) <br />1OV QUADPLEX RECEPTACLE <br />®JOINTED) <br />IOV DUPLEX RECEPTACLE (FLOOR <br />20V RECEPTACLE (4 WIRE <br />:ONNECTOR) <br />OICATED RECEPTACLE <br />L MOUNTED LIGHT <br />(LING MOUNTED LIGHT <br />ANLIGHT <br />L000 LIGHT <br />L SCONCE PRE -WIRE <br />T FAN WITH LIGHT (I CFM PER SQ. FTJ <br />BULD LIGHT FIXTURE <br />�4B <br />BULB LIGHT FIXTURE <br />8B� <br />BULB LIGHT FIXTURE <br />'TRACK LIGHTING <br />TTIC LIGHT WITH PULL CHAIN <br />�� <br />ER CABINET LIGHT <br />® <br />'x4' FLUORESCENT LIGHT (RECESSED) <br />m <br />'x4' FLUORESCENT LIGHT (SURFACE <br />OUNT) <br />'x4' FLUORESCENT LIGHT (RECESSED) <br />xrL <br />O <br />GES6 LIGHT <br />• <br />CESS LIGHT (VAPOR PROOF) <br />ILMG MOUNTED LIGHT WITH J-BOX <br />OPT. FAN <br />LECTRICAL PANEL (FIELD VERIFY <br />&CATION) <br />t0 <br />-BOX (WALL MOUNTED) <br />CEILING MOUNTED) <br />MOUNTED FAN <br />CI CFM PER 8OL FT.) <br />ACKETECTOR <br />(WALL MOUNTED) <br />IF(DZ <br />ETECTOR (CEILING MOUNTED) <br />)T <br />• LOCATION OF TV J t PHONE &U L i t <br />TO DE VERIFIED • HOMEOWNER <br />PRE -CONSTRUCTION MEETING. <br />• ALL 15 4 20 AMP BRANCH CIRCUITS TO BE ARC <br />FAULT PROTECTED PER ELECTRICAL PROVISIONS <br />OF FBCR Nth EDITION (2020) 4 NEC 210.12 2011 <br />• 220MMPITAP DEDICATED LAUNDRY CIRCUIT. <br />• GFI • ISLAND (NOT ON KITCHEN CIRCUIT) <br />• DISHWASHER DISCONNECT TO BE LOCKOUT IN <br />PANEL <br />• BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY <br />OF 50 CFM INTERMITTENT PER ELECTRICAL <br />PROVISIONS OF SECTION MI50T3 POOR Nth <br />EDITION (2020). <br />• LAUNDRY ROOM RECEPTACLE SHALL BE GROUND <br />FAULT CIRCUIT -INTERRUPTER PROTECTION FOR <br />PERSONNEL ON FEEDERS <br />• WIRING METHOD SHALL BE NON METALLIC CABLE <br />PER ELECTRICAL PROVISIONS OF PBCR Nth ED <br />(2020). <br />• ALL WORK TO COMPLY WITH ELECTRICAL <br />PROVISIONS OF THE FBGR ITH ED (2020). <br />• ALL LAMPS SHALL BE SELECTED BY BUILDER <br />AND 15% OF LIGHTRJC MUST BE ENERGY EFFICIENT <br />TYPE PER FDL. ENERGY CONSERVATION <br />(RESIDENTIAL ENERGY EFFICIENCY) mi. Nth <br />EDITION M404J <br />-------------- <br />BEDROOM <br />I 1 <br />I <br />I <br />I <br />I <br />I <br />FOR <br />CLG FAN <br />I <br />I <br />L _ _ — _ <br />.I <br />— — J <br />/BATH 1 t <br />I r�� <br />� \ I <br />I <br />I <br />BEDROOM <br />� I <br />� I <br />I <br />I <br />a I <br />PRE -WIRE \ <br />FOR \ <br />GLG FAN \ <br />I SD <br />HB <br />\ Sio <br />/ <br />_N/ <br />BATH <br />2 <br />\ =g <br />PRE -WIRE <br />FOR <br />CLG FAN <br />r =�\ <br />I / \ I <br />I� D/1 <br />UP, I L--J <br />[al I <br />1�IS <br />PRFIRE <br />OR <br />/ CLG FAN <br />I <br />I I <br />\ I \ <br />GFIGp <br />0 T" 0 <br />i1 <br />DICO <br />I / I <br />I / I <br />I i I <br />I / I <br />I � I <br />I / I <br />I I I <br />� GREAT ROOM <br />JUNCTION. <br />BOX TINDER <br />/ \ COUNTER FOR <br />PRE -WIRE \ I DIU. <br />FOR \ <br />CLG FAN \\ Ot <br />I I \ I <br />I I . <br />\\ CL <br />1 \- Q <br />1 <br />1 _ <br />1 DINING <br />11 ROOM / <br />1 OPT. DINING j <br />1 FIXTURE <br />I — <br />I 1 SD/CO <br />/ m <br />I <br />I u <br />I <br />I FOYER <br />\ <br />r <br />I I <br />WIP 1 \ HoGFI <br />ENTRY,RZ <br />I <br />p <br />/ PRE -WIRE <br />/ FOR <br />/ CLG FAN <br />I <br />1 <br />KITCHEN <br />CFI* CFI• <br />44'AFFr Y-( 44'AFF. <br />�JJ <br />44'AFF. \ <br />a <br />PRE \ <br />LIGHT t <br />PLUMB 1 <br />SWITCH IN <br />L.T. <br />ATTIC <br />1 <br />ACCESS <br />I <br />------------ <br />� <br />1 <br />GFI CLG.8 <br />GFI CLG.6 <br />OUTLET GARAGE <br />OUTLET <br />) <br />OUTLET FOR <br />IRRIGATION <br />TIMER <br />ELEC. FOR <br />HOOD/ <br />MICRO A5V. <br />------- <br />I it I I I <br />I t I I i I t I <br />LED LIGHTING LED LIGHTING LED LIGHTING <br />® DOUBLE LAV. SINGLE LAV. C SINGLE LAV. <br />BATH I BATH 2 BATH 3 <br />PROVIDE 3 2/0 CU. I % CU GND 2" CCNOUTT OR <br />PROVIDE 3 4/0 AL, 1 4 AL GND IN Y' CONDUIT. <br />(CONDUIT TO TERINATE ABOVE SOFFIT • OVERHANG) <br />200 AMP ELECTRICAL RISER <br />NOT TO SCALE. <br />COMBINATION 200 AMP <br />LL GENERAL NOTES, SERVICE I20R40 VOLT <br />W' A ELECTRICAL MATERIALS AND INSTALLATIONS <br />LL SHALL COMPLY WITH ELECTRICAL PROVISIONS OF M SWITCH AND <br />CT I PHASE <br />THE FBCR TTH EDITION ()020). LOCAL CODER, AND ELECTRIC PANEL <br />ALL LOCAL POWER COMPANY REtGUIIlB•RNTB, METER IN NEMA <br />B. ALL CONDUCTORS SHALL BE TYPE THHN/TFEN 200A/! 3R ENCLO&IRE <br />W.ESS NOTED OTMERWSE. <br />PRE -WIRE -- PRE -WIRE PRE -WIRE <br />FOR COACH FOR COACH FOR COACH <br />LIGHT LIGHT LIGHT <br />ELECTRICAL PLAN <br />SCALE: 1/4'.1'-0' <br />POWER COMPANY <br />TRANSFORMER <br />PROVIDE 200 AMP, 120/240 VOLT,.I PHASE --� <br />SECONDARY ELECTRICAL SERVICE. PROVIDE 3 <br />•2/0 COPPER (CU) IN 2" DIA SCHEDULE 80 PVC <br />CONDUIT OR PROVIDE 3 4/0 ALUMINUM! (AL) IN <br />2" CIA SCHEDULE 80 PVC CONDUIT UNLESS <br />SERVICE IS PROVIDED BY THE ELECTRIC <br />COMPANY. COORDINATE WITH THE ELECTRIC <br />P COMPANY ROR TO BID. <br />TELEPIIRIE CABLE <br />SERVIC! CAVILS CN <br />CNTRMICE SERVICE <br />CQIIR'!Nf ENiR4110E <br />E(i/IFMBIT <br />INTERSYSTEM BONDING TERMINAL AT <br />LOW VOLTAGE CONNECTIONS <br />1 4 Cu SERVICE GROUND <br />CONNECTED TO CONCRETE <br />ENCASED ROOTER STEEL PER <br />ELECTRICAL PROVISIONS OF <br />FBCR ITH EDITIQJ l2t720) <br />S/6" CIA X 8 FT LONG COPPER <br />CLAD GRAND ROD <br />A L C N I T L C T L <br />GrouPOL�. <br />441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdoeigngroup.com <br />AA#: 0003325 <br />III DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 81"86.2628 <br />FAX: 813586.2802 <br />sUHDm ac LOT: <br />SILVERADO <br />LOT #21 <br />BLK. #16 <br />PROJECT* <br />03719.001-21161 <br />MODEL: <br />3 8-D <br />GARAGE BTf MG: <br />RIGHT <br />PAGE: <br />ELECTRICAL <br />PLAN <br />150 YPH E . B <br />DwAA E: 7/09/21 <br />SCALE: <br />SHEET <br />E1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.