Laserfiche WebLink
A-(1) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(9) 1Od x 1 }'NAILS TO TRUSS <br />8{2) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(12) 16d x 1 }'NAILS TO TRUSS <br />DBL STRAP, 1 EACH SIDE WRAPS UP AND <br />OVER TRUSS (NOT SHOWN) <br />C41) SIMPSON LGT2 GIRDER TIEDOWN WITH <br />(16) 10d x 3 �' NAILS TO GIRDER AND <br />(2) SIMPSON HETA16 TRUSS ANCHORS <br />WITH (12)16d x 3 }" NAILS TO GIRDER <br />1Y2, 2x WOOD FASCIA <br />SEE ARCHITECTURAL <br />2x SECURED W/ (3)16d <br />GALV. COMMON NAILS. <br />lx2 SECURED W/ 10d <br />GALV. COMMON NAILS <br />12. O/C <br />MASONRY BOND BEAM <br />SEE SCHEDULE <br />PLYWOOD SHEATHING, SEE <br />"ROOFANALUFLOOR <br />SHEATHING <br />FASTENER SCHEDULE" <br />NOTE: A PT SYP #2 Z' x 4", <br />6'. 8" x 4'-0" MAY BE ADDED <br />W/ 10d NAILS, 2 ROWS, 3" <br />O/C TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE TRUSS <br />ANCHOR REQUIREMENTS. <br />ENGINEERED WOOD <br />TRUSSES @ 24" O/C, <br />SUBMIT SHOP DRAWINGS <br />FOR REVIEW <br />AND APPROVAL <br />A ALLOWABLE UPLIFT = U: 1810 LBS, L:770 LBS (1 PLY) <br />B ALLOWABLE UPLIFT = U:2365 LBS, L:1430 LBS (2 OR 3 PLY) <br />C ALLOWABLE UPLIFT = U:2705 LBS (2 PLY) <br />1A 16 1C TYPICAL TRUSS/ <br />GIRDER CONNECTOR(S) <br />3/4" T 8 G SUBFLOOR GLUED AND <br />SCREWED AS PER SCHEDULE <br />\ L PRE-ENG FLOOR TRUSS <br />5/8" GYPSUM BOARD OR 1/2' HIGH <br />STRENGTH CLG. BOARD <br />SECURE TRUSS TO TOP PLATE W/ (2) <br />16d TOENAILS <br />DOUBLE TOP PLATE <br />2x4 OR 2116 WOOD BEARING <br />WALL W/ SYP No 2 STUDS SEE <br />PLANS FOR SPACING. SINGLE <br />BTM. PLATE TO BE PT. <br />PROVIDE DBL. TOP PLATE <br />PROVIDE BLOCKING <br />1/22' GYP. WL. BD. <br />�• f <br />r,--'\FLOOR TRUSS CONNECTION @ L.B.W. <br />`+ scALE:34"=1-a' (NO UPLIFT) <br />PTH 114•0 <br />OLE EDGE >5/e" <br />OLE DIAMETER <br />2!5•D SGL. STUD <br />OUTERplf//w,djk. <br />SPAN <br />—HOLE EDGE >5/8" <br />BTM.— <br />PLATE <br />STUD NOTCHING <br />%1 AND BORING LIMITS <br />0 SCALE: 1 1/2"=1'-0" <br />HOLE DIAMETER <br />< 3/5•D DBL. STUD <br />ENGINEERED WOOD TRU <br />0 24" O/C, SUBMIT SHOP <br />DRAWINGS FOR REVIEW <br />AND APPROVAL <br />(1) SIMPSON HETA16 —� <br />TRUSS ANCHOR WITH <br />(9) 10d x 1 }" NAILS TO <br />GIRDER. PROVIDE 6' <br />MINIMUM CONCRETE <br />EMBEDMENT. USED IN <br />CONJUNCTION WITH <br />HEAVY UPLIFT <br />CONNECTOR <br />2x WOOD FASC <br />SEE ARCHITECTURAL <br />SEE <br />2x SECURED W/ (3) 1 <br />GALV. COMMON NAILS. <br />GG� <br />1x2 SECURED W/ iOd <br />MASONRY BOND <br />GALV. COMMON NAILS <br />BEAM <br />12" O/C <br />SEE SCHEDULE <br />PLYWOOD SHEATHING, SEE <br />"ROOF/WALUFLOOR <br />SHEATHING <br />FASTENER SCHEDULE" <br />NOTE: A PT SYP #2 Z' x 4", <br />6", 6' x 4'-0" MAY BE ADDED <br />W/ 10d NAILS, 2 ROWS, 3" <br />O/C TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE GIRDER <br />TIEDOWN REQUIREMENTS. <br />A41) SIMPSON LGT3-SDS2.5 GIRDER TIEDOWN <br />WITH (4) r x 5" TITEN HD TO CMU AND (12) SDS <br />}" x 2 J•' TO GIRDER <br />13 (1) SIMPSON FGTR GIRDER TIEDOWN WITH <br />(2) j" x 5" TITEN HD TO CMU AND (18) SOS }'x <br />3" TO GIRDER <br />C42) SIMPSON FGTR GIRDER TIEDOWNS WITH <br />(2)}' x 57ITEN HD TO CMU AND (18) SOS }" x a <br />SCREWS TO GIRDER (EACH TIEDOWN) <br />ENSURE THAT CELLS ARE GROUTED <br />SOLID, 8" EACH WAY OF BOLTS <br />A ALLOWABLE UPLIFT = 3285 LBS (2 OR 3 PLY) <br />B ALLOWABLE UPLIFT = 4725 LBS (2 PLY MIN.) <br />C ALLOWABLE UPLIFT = 8885 LBS (2 PLY MIN.) <br />�A 2B 2 TYPICAL ROOF <br />"' "� GIRDER CONNECTORS)' <br />LSTA12 20 GAUGE <br />W/ 10dxl/2 HDG NAILS <br />0 EACH END. TOTAL OF 10 <br />FLOOR <br />GIRDER <br />HTT4 W/ 5/8•' A.B. WITH <br />MIN. 7" EMBEDMENT �-+ <br />TO SLAB 8 (18) 16d x <br />2-11" NAILS TO POST., <br />POST TO SIT DIRECTLY <br />ON SLAB <br />4 <br />r,_'�GIRDER/WOOD POST CONNECTIONS <br />NOTE: <br />A- WHEN TRUSS BEAR ON TOP OF LEDGER USE SIMPSON HTS20 FROM <br />A - SIMPSON HUS28 G < 1200 LBS, U < 1280 LBS W/ (1) 3/4— SIMPSON TITEN BOLT/J-BOLT, 5" MIN. <br />EMBED (22)16d GALV. COMMON NAILS AND (8) 16d GALV. COMMON NAILS. <br />B - SIMPSON HUS28 G < 2400 LBS, U < 1425 LBS W/ (2) 3/4" SIMPSON TITEN BOLT/J-BOLT, 5" MIN. <br />EMBED (22) 16d GALV. COMMON NAILS AND (10) 16d GALV. COMMON NAILS. <br />C - SIMPSON HGUS28-2 G < 2400 LBS, U < 1810 LBS W/ (2) 3/411 SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS. <br />D-SIMPSON HGUS28-2 G < 4800 LBS, U < 1810 LBS W/ (4) 3/4"" SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS. <br />E-SIMPSON HGUS28-3 G <4800 LBS, U < 1810 LBS W/ (4) 3/4"• SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12)16d GALV. COMMON NAILS. <br />WOOD LEDGER <br />9 ATTACHMENT DETAIL <br />SCALE: 3/4"=1'-0" <br /># 1100 UPLIFT SIMPSON <br />HTSM20 W/1010d TO <br />TRUSS AND (4)1/4" x 2 1/4' <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br /># 1900 UPLIFT (2) SIMPSON <br />HTSM20 INSTALLED ON <br />OPPOSITE FACES OF <br />BLOCK WALL W/1010d TO <br />TRUSS AND (4)1/4" x 2 1/4" <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br />PRE-ENG TRUSS <br />CONTINUOUS BOND BEAM <br />TITEN 2 ANCHORS MIN. <br />2' COVER 8 2' APART <br />REPAIR OF MULTIPLE <br />MISPLACED EMBEDDED TRUSS ANCHOR <br />3 SCALE: 3/4"=1'-0" <br />6'-0" MAX (W/1X4) <br />R 10'-0" MAX (W/2X4), <br />10 DIAGONAL <br />BTM.CHORD <br />BRACING, SEE <br />PLAN FOR LOCATION <br />MAY NOT BE <br />REQUIRED <br />BTM. CHORD OF <br />WOOD ROOF TRUSSES <br />10 BTM. CHORD BRACING 6-0" O/C END WALL OR OTHER <br />MAX., OR 2x4 BTM. CHORD BRACING END TYPE CONDITION, IF <br />10'-0" O/C MAXSECURED W/ (2) 10d DEPICTED SEE PLAN <br />COMMON NAILS AT EACH CHORD /� /� /� <br />INTERSECTION TYP. BTM. CHORD BRACING <br />6 SCALE: 3/4"=1'-O' <br />6 EDGE <br />CENTRAL <br />SPACING <br />SPACING <br />SEE <br />SEE BTM <br />CHEDUL <br />G <br />SCHEDULE SEE FRAMING PLAN <br />SEE SCHEDULE FOR BOLT SIZE <br />SEE LEDGER SCHEDULE W <br />5 VZ' MIN. EMBED. (TYP) <br />1. ENSURE THAT EXP. BOLTS/J-BOLTS ARE <br />PLACED INTO GROUTED CELLS, 8" ALL AROUND <br />BOLT. <br />Z. <br />2. END OF FRONT AND REAR LEDGER SHOULD <br />°D <br />LAP A MIN OF 4'-0". <br />3. ALL BOLTS TO HAVE WASHERS <br />4. EXP. BOLTS/J-BOLTS SHOULD NOT BE ANY <br />CLOSER THAN 6" O/C. <br />5, IN LIEU OF HILT] PAPS SIMPSON TITEN 1/4" <br />(2) _ PT <br />DIA. z 3" MASONRY SCREWS MAY BE USED, <br />CDGI`I�.I!_ OCt1111DFE,IDNT <br />LEDGER SCHEDULE <br />MARK <br />SIZE <br />BOLT SIZE <br />B®GESPACING <br />CENBIALSPACIIG <br />A <br />DOUBLE 2x8 <br />1/2' <br />81, O/C <br />16" O/C <br />B <br />DOUBLE 2x8 <br />3/4" <br />8" O/C <br />24" O/C <br />C <br />DOUBLE 2x10 <br />1/2" <br />8" O/C <br />161, O/C <br />D <br />DOUBLE 2x10 <br />3/4" <br />8" O/C <br />24" O/C <br />E <br />DOUBLE 2X10 <br />3/4" <br />6" O/C <br />16" O/C <br />F <br />DOUBLE 2x12 <br />34' <br />6" O/C <br />1 12' O/C <br />10 WOOD LEDGER DETAIL <br />SCALE: 3/4"=T-0' <br />(2) 2X4 No.2 SYP DIAG. <br />2x4 BLOCKING BETWEEN <br />BRACE W/ (3) 12'1 @ EA <br />TRUSSES WHERE <br />TRUSS (DIAG. BRACE TO <br />X-BRACING IS PRESENT AT <br />COVER 5 TRUSSES) <br />4-0" O.C. (AT SHEATHING <br />0'-0" TO 30'-0" (1) "X" BRACE <br />SEAMS) <br />30'-1" TO 60'-0 (3) "X" BRACE <br />SECURE 2x8 PT. PLATE <br />(1) "X" BRACE @ CENTER <br />TO BLK W/ 1/2' DIA. <br />(2)'OC" BRACE DIVIDED EQUALLY <br />ANCHOR BOLT W/ Z' <br />FROM CENTER TO END. <br />WASHER SET IN HIGH <br />2x WOOD FASCIA, <br />STRENGTH EPDXY 6' <br />SEE ARCHITECTURAL <br />MIN. EMBED. AT 32' OC <br />MAX. <br />PRE-ENG GABLE TRUSS <br />SECURE GABLE TO 2x8 <br />P.T. PLATE W/ 12d's 8" <br />STIFFBACK (AS PER <br />O.C. MAX <br />TRUSS ENG) <br />CONT. 2z4 SECURED W/ <br />(2)10d's @ EACH TRUSS <br />TO BE INSTALLED @ <br />10'-0" O.C. MAX. <br />SEE SCHEDULE FOR <br />BOND BEAM REQ. <br />7 BLOCK WALL W/ GABLE END <br />PRE-ENG'D TRUSS SCALE 3/4"=1'-0 <br />THE USE OF ALTERNATE MATERIALS MAY BE <br />USED SO LONG AS THEY CONFORM TO THE <br />FOLLOWING <br />1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS <br />A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS <br />EQUIVALENT OR GREATER UPLIFT AND LATERAL (Ft AND F2) LOAD CAPACITIES <br />AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND <br />ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE <br />THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO <br />A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, F1, AND F2 <br />FORCES ALL AT THE SAME TIME, FLOOR TRUSSES NOT EXPOSED TO WIND ARE <br />SUBJECT TO F1 AND F2 FORCES. <br />11 ALTERNATE MATERIALS <br />SCALE: 3/4"=T-0' <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL 32750 <br />PH: 407-774.6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #: 0003326 J <br />IF DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813$88-2628 <br />FAX: 81"86-2802 <br />OUHDIV. AO LOT <br />SILVERADO <br />LOT #5 <br />BLK #16 <br />PROJECT# <br />3%ODEI. <br />2795-CAMDEN" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />DETAILS <br />150 MPH A B <br />DwR7E 06/10/21 <br />SCALE: 1/4"=1'—O" <br />8*mET <br />S3.IA <br />