Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE, <br />X <br />I. BOTTOM. 2. SIDES, 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />Ij <br />TOOLED SO AS TO DEFLECT <br />r <br />WATER AWAY FROM JOINTS. <br />X.^ <br />E-Z BEAD ALL AROUND <br />i.,.{:_ <br />i yX <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />�r. <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES.V CAULKING a JOINT <br />I <br />ALL AROUND <br />PER SECTION R703.7 <br />Exterior lathing and plastering <br />BACKER ROD <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />X; <br />1 X: <br />Installation of exterior lathing and framing <br />X <br />shall comply with ASTM C 1063-19a, <br />/ <br />or ASTM 1787. <br />WRB LAYER -1, <br />STUCCO WRAP <br />- <br />HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WaB LAYER °2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />( FRAME) <br />WOOD SHEATHING <br />LAYER 9, <br />STUCCO WRAP <br />LAYER "FORTIFIBER <br />BUILDING PAPER <br />WOOD <br />coNeTucnaN <br />—METAL LATH <br />a' C: U VINYL CASING BEAD <br />6' RAISED BAND <br />V TON MID -WALL <br />ogee w-men <br />6' WDE STRIP SELF <br />ADHESIVE FLASHING, CLEW <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />WISTONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER e2 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 7/Iro' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.I / ASTM C-841-14a, MIN. 2.5 LBS. <br />PER SO. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />W SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT i <br />TOP 4 SIDES <br />GB DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL1 <br />V SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANIF. SPECS.) <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METEf <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER "I, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />Y5' TO Ye' MID -WALL <br />WEEP SCREED <br />LW SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />- , R:::� <br />WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER 01, <br />STUCCO WRAP <br />WOOD SHEATHING <br />ELEC. METER FIELD APPROVED <br />VERIFY LOCATION 4MSBNBZA'P <br />BELOW <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />CUT SUCH THAT <br />NO MEMBRANE <br />PRIOR TO INSTALLING ELEC. <br />ENTERS BOX, <br />METER <br />APPLY TO FACE <br />EDGE <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYf3LEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />14— APPLY A SILICON <br />BASE SEALANT AT POINT <br />IT 17 THAT ELEC. WIRE PENETRATES <br />!00 <br />�~ <br />WOOD SHEATHING <br />WIB LAYER "I, <br />STUCCO WRAP <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STgJCTURAL <br />MEMBER • 1' O.C. MAX <br />K' TO K' MID -WALL <br />Wa' °'ritP airitn�F�6� <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />V_ _ FINISH • MASONRY <br />7B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />S' <br />WRB LAYER °I, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB <br />LAYER '1 <br />STEP #1 STEP *2 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />APPLY E-Z BEAD <br />• <br />(SEE TYPICAL WALL <br />SECTION)° <br />OVER 60 MIN <br />; <br />° <br />GRADE 'D' <br />METAL LATH <br />FELT -PROVIDE <br />PROVIDE STUCCO SCRATCH <br />SEALANT AT ALL <br />o, <br />COAT LARGER THAN THE ELEC. <br />JOINTS AND <br />METER CAN OR METER CAN <br />INTERSECTIONS <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />STEP 05 STEP #(o <br />nELECTRICAL RECEPTACLE <br />I" <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdmigngroup.com <br />AA #: 0003325 J <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813886-2628 <br />FAX: 813-886-2802 <br />SUHDIV. & LOT: <br />SILVERADO <br />LOT #20 <br />BLK #16 <br />PROJECT <br />03719.00T-20161 <br />MODEL: <br />GARAGE SWING: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />15 H B <br />JUL <br />D,W7/09/21 <br />DATE• <br />SCALE: <br />SHEET <br />WAS <br />