Laserfiche WebLink
17'-2" <br />4'-6" <br />9'-8" <br />1.,., <br />5'4" <br />7'-10" <br />4'1" <br />iO <br />T <br />"' <br />SLAB <br />------------------- <br />----� TE-1 ----- <br />------ <br />----- ------ <br />—4-- <br />1 <br />I 3 1 FM-16X18 <br />I 1 FM-16X18 <br />�; <br />I <br />I <br />1 1 I <br />ii 1 <br />4" CONC. <br />i 1 <br /><q <br />oa SLAB <br />mlii <br />w <br />� <br />I <br />w1 <br />1 <br />1.1 m i� <br />I <br />I <br />I <br />I 4" PVC <br />CHASE <br />3'-1" 9'-2" 3'-l" I !i <br />I -31/2" i <br />I <br />LLL16. <br />I <br />�__ J (( <br />I <br />13,_B„ <br />-------—------— —— <br />—— <br />FM-16X16 <br />L—TE-2 <br />1 it <br />1.1 EXTEND <br />I <br />SLAB 1 112" 1 <br />1 <br />ii <br />I <br />a 1 <br />I hL <br />ii <br />I <br />-3 1/2 <br />f f <br />I <br />J <br />2' 5" i 10 9" <br />I <br />F TE-2 <br />ro1 <br />I <br />1 72 <br />i� <br />li <br />�I <br />1 <br />1 <br />4 <br />ii i <br />I <br />0'-0" FIN. ELEV. <br />FIN. CQNC. SLABCON. SLAB <br />I <br />1" PVC CHASE (( (� <br />�•1 <br />I <br />FORD <br />ELEC a <br />I <br />ISLAN <br />1 <br />ii i <br />I <br />i <br />I 1 <br />,., <br />it it <br />34'-10" i 1 13'-2" <br />I <br />I X <br />1! <br />Y <br />I <br />• <br />I <br />„ <br />I <br />191-6" ti <br />2'-8" <br />I <br />5'-6" <br />--- <br />----J <br />1 <br />1 <br />--------------TE1--- <br />r ----- <br />1/2" <br />*:3 <br />EXTEND <br />I <br />SLAB 1 1/2" N <br />1 <br />I <br />I <br />Q <br />I <br />I <br />I <br />I <br />• I <br />20'-4" 1 <br />24,A„ <br />TA„ I <br />I <br />I <br />� <br />I <br />2 I <br />� <br />I <br />EXTEND <br />„ <br />SLAB 1 1/2" FM-16X18 <br />o <br />I <br />1 1/2" I„ ,2, <br />LL I <br />I 24"x24"02"GONG. <br />I 5" 5'-5" 6" (X <br />I <br />• I FTG. <br />I REBARS EA. WAY <br />1.1 1 I-i: z m : CS <br />I ON CHAIRS MIN. 3" <br />`O y ILL <br />1 COVER _ <br />1 a 24"x24"x12" CONC. <br />rn I FTG. W/ (3) #5 REBARS <br />4 <br />4 <br />I 1 <br />+ I EA. WAY ON CHAIRS <br />5 1/2" <br />FM_16 18--1.1 <br />I <br />L --- FM-16 ------ <br />I MIN. 3" COVER <br />J---------- <br />- <br />FM-i6X18 -- <br />F <br />E-1 <br />8„ 5'-0" ro 8„ 4 <br />4 <br />3'-2" <br />T-10" <br />6'-4" <br />1'_0„ 4,_4„ 1,_p„ ,_4.. ,.1 16,_0„ <br />,.i <br />,_4„ <br />4„ 8,_0„ <br />,_4„ <br />6'-4" <br />181_81. <br />48'-0" <br />,,,,-4" CONC. <br />SLAB <br />FOUNDATION NOTES <br />1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR <br />COMPACTING REQUIREMENTS. <br />2. TOP OF FINISHED SLAB SHALL BE +4-0". <br />3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED <br />OTHERWSE. <br />4. REFERENCE ELEVATION + 0'-0", SEE SURVEY PLOT FOR NAVD. <br />5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER <br />SERVICES. <br />6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: <br />PROVIDE 1/2" FELT PAPER AT THE JOINT. <br />7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL <br />DRAWINGS. <br />8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING. <br />9. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE <br />WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS <br />AND WITH THE MANUFACTURES SPECIFICATIONS. <br />10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. <br />11.EIINDICATES #5 BAR, EIINDICATES #6 BAR,RINDICATES #7 BAR VERTICAL <br />REINFORCING BAR IN CELLS FILLED WITH GROUT, ENDS OF REINF. BARS SHALL BE <br />HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 90° <br />HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. <br />12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = <br />30", #6 =36'), AND REINFORCING SHALL BE CONTINUOUS, <br />13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL <br />REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE <br />SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS <br />BEEN DELETED UNLESS NOTED OTHERWISE. <br />14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS <br />OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: <br />A)IN ALL WALL INTERSECTIONS B)CHANGES IN ELEVATION <br />C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS <br />15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH TMS 402/602-16, BUILDING CODE <br />REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. CONSTRUCTION <br />SHALL BE IN ACCORDANCE WITH TMS 402/602-16, USING: F'm = 2,000 PSI, TYPE "M" OR"S" <br />MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN RUNNING BOND. <br />16. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER i OF SLAB SUPPORTED <br />T-0" O/C MAX. SEE PLAN FOR WWM SIZE. <br />INSPECTOR NOTE: <br />1. STRUCTURE WAS DESIGNED BASED ON THE 2020 FLORIDA RESIDENTIAL BUILDING <br />CODE, RESIDENTIAL, 7lh EDITION <br />SLAB SCHEDULE <br />SLAB <br />THICKNESS <br />I REINF. <br />REMARKS <br />6x6 W1.4xWIA OVER <br />GENERAL <br />3 1/2' <br />6 MIL VAPOR <br />COMPACTED FILL <br />BARRIER <br />FOOTING SCHEDULE <br />PROVIDE CORNER BARS SAME SIZE QUANTITY AS BARS IN FOUNDATION WITH 30' LEG EACH WAY. <br />MARK <br />WIDTH <br />LENGTH <br />THICKNESS <br />BOTTOM REINF. <br />TOP REINF. <br />T.O.F. <br />SHORT <br />LONG <br />FMA&18 <br />16, <br />CONTINUOUS <br />16' <br />- <br />(2)#5's <br />FMC-16xl8 <br />16" <br />CONTINUOUS <br />18" <br />- <br />(2)#5's <br />#5 IN CURB <br />VARIES <br />F-2424 <br />24" <br />24' <br />12, <br />(2)#5's <br />(2)W. <br />TE-1 <br />8" <br />SEE PLAN <br />8" <br />- <br />(1)#5's <br />TE72 <br />B" <br />SEE PLAN <br />8" <br />FOUNDATION PLAN <br />SCALE: 1/4" = V-0" <br />A R C N IT E C T• <br />6 <br />�Sgn <br />Group. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 8134H6-2628 <br />kIII FAX: 813-886-2802 <br />SU13MV. de LOT <br />SILVERADO <br />LOT #20 <br />BLK #16 <br />PROJECT <br />03719,001-20161 <br />MODEL <br />23 8— <br />GARAGE STI/ING: <br />PAGE: <br />FOUNDATION <br />PLAN <br />IL 15Y4VH E <br />