Laserfiche WebLink
INSTALL 6' SELF-ADHERNG <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANCsEB OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />BEOUENCE OF FLASHING TO BE: <br />L BOTTOM. 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />, <br />SIDES ONLY. SEALANT IS TO BE <br />I' <br />TOOLED SO AS TO DEFLECT <br />1 <br />WATER AWAY FROM JOINTS. <br />X.' E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />i <br />JOINTS AND INTERSECTIONS <br />R <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, Yi CAULKING • JOINT <br />ALL AROUND <br />I I <br />PER SECTION R703.7 <br />Exterior lathing andWasterina <br />Exterior use of Portland cement plaster <br />BACKER ROD <br />shall comply with the application <br />�1. <br />requirements of ASTM C 926-18b. <br />X <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />1 <br />or ASTM 1787. <br />WRB LAYER °I, <br />STUCCO WRAP <br />I <br />HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRS LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT ( FRAME) <br />WOOD SHEATHING <br />LAYER M, <br />STUCCO WRAP <br />LAYER 7, FORTIFIBER <br />BUILDING PAPER <br />= <br />coNe7ucr� <br />—METAL LATH <br />a' Cm VINYL CASING BEAD <br />W RAISED BAND <br />ti <br />76' TO K' MID -WALL <br />IICCP MRk <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIF15ER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16" ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R-1031.1 / ASTM C-84-1-14a, MIN. 2.5 LBS. <br />PER $0. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP a SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />7 — — — <br />PIPE THROUGH / <br />WALL <br />1 <br />b' SELF ADHESIVE <br />FLASHING (INSTALL <br />PER MANUF. SPECS) <br />BUILDING PAPER <br />/ <br />UNDER 'QUICK FLASH' <br />�A VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />—ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRI5 LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />Ya' TO Ya' MID -WALL <br />WEEP SCREED <br />�6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />""" " I—— R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />:0 SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COM50 OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER "I, <br />STUCCO WRAP <br />WOOD SHEATHING <br />WOOD SHEATHING <br />WRB LAYER M, <br />STUCCO WRAP <br />WRS LAYER 4, FORTIF15ER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • I'Or— MAX <br />)k TO)6' Min -WA L <br />WEEP SCREED <br />6' WIDE STRIP SELF <br />AD14EOIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />V FINISH • MASONRY <br />�B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />S' <br />WRB LAYER "I, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING 1- e+ <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB <br />LAYER M <br />STEP *1 STEP *2 <br />HOUSEWRAP <br />WRB LAYER •I, <br />BELOW <br />STUCCO WRAP <br />CUT SUCH THAT <br />9 <br />APPLY 60 MIN <br />SELF -ADHERING <br />NO MEMBRANE <br />GRADE 'D' FELT <br />MEMBRANE FLASHING <br />ENTERS BOX, <br />_ <br />OVER <br />APPLY TO FACE <br />SELF -ADHERING <br />EDGE <br />NG <br />FLASHIOVER <br />APROVED <br />HOUSEWFU <br />WRB LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />STEP 03 <br />STEP #4 <br />ELASTOMIERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />APPLY E-Z BEAD <br />IEEE TYPICAL WALL <br />SECTION) <br />OVER 60 MIN <br />•o e• <br />GRADED' <br />°' ;, <br />METAL LATH <br />FELT -PROVIDE <br />SEALANT AT ALL <br />° <br />o° <br />JOINTS AND <br />INTERSECTIONS <br />STEP 05 STEP #(o <br />OELECTRICAL RECEPTACLE <br />I R C N I T E C T N <br />GrMoNsP <br />1941 Iv. RVIYXLU f<LNVXIv °Lv <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA 8: 0003325 V. <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813886-2628 <br />FAX: 813-886-2802 <br />INnI� <br />anmum <br />SUSDIV. & LOT, <br />SILVERADO <br />LOT #19 <br />BLK #16 <br />PROJECT# <br />03719.001-19161 <br />MODEL. <br />3278—JORDYN II <br />GARAGE OWING: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />15hMPH a C <br />