My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35956 Morse Willow Ct
Zephyrhills
>
Building Department
>
Building Plans
>
35956 Morse Willow Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 7:19:19 PM
Creation date
2/24/2025 9:58:03 AM
Metadata
Fields
Template:
Building Plans
Street #
35956
Location
Morse Willow Ct
Contractor
D R Horton
Building Plans - Permit #
2713
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NOWCONDITIONED ALAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC ITH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />B. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL. BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC NTH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC TTH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC NTH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S ALL FIRE RATED CEfLINGB AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MM RECOMMENDATIONS AND FBC TTN <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTEC 4 DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />m <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE. RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OSD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN s LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />19 <br />PASS-THRU AIR GRILL <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />>F001 <br />0EILING <br />EXTERIOR WALL <br />SECURE STRAP TO CONC. <br />CONDENSER <br />PLENUM <br />T <br />y <br />AIR RETURN <br />W/ (2)-3/I6'X2' TAPCONS <br />UNIT <br />SIMPSON WB ROLL STRAP <br />OR EQUAL <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />AIR HANDLER <br />y <br />SECURE STRAP TO UNIT W/ (2) <br />4' CONCRETE SLAB 08XI I/4' SHT. MTL. SCREWS <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />CONDENSER UNIT <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />CONNECTION TO PAD <br />T <br />REFRIGERANT LINES TO <br />PLATFOR-I <br />RETURN <br />CONDENSING UNIT <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />TRAP DRAIN LINE AND TERMINATE <br />OVER HEAD • 12' FROM STRUCTURE <br />IN AN APROVED DRAIN, AS PER <br />FSCR'ITH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL COUNTERSUNK <br />FIN. FLOOR C.O. PLUG <br />BRONZE FL. PL. OR WALL 6' <br />--SEE SPEC, <br />1'-81X8' CONC. <br />BRASS PLUG <br />FIN. GRADE <br />OR PAVING <br />FITTING OR EXTENSION TO <br />BOIL OR WASTE AS FITTING OR <br />REQUIRED EXTENSION TO SOIL <br />OR WASTE AS <br />WADE 8240-K JOSAM 56MO REQUIRED <br />NSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (TY�P.) OEXT. GROUND CLEAN -OUT (T <br />e <br />MECHANICAL PLAN <br />SCALE= 1/4' " I'-0' <br />A R C N I T E C T• <br />6 <br />Grou.0.n <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32750 <br />PH: 407-774 6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA N: 0003325 <br />D7 <br />M <br />R <br />SUBDIV. & LOT: <br />14 <br />SILVERADO <br />LOT #18 <br />BLK #16 <br />PROJECT# <br />03719.001-18161 <br />MODEL: <br />"2045-UNTANA" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />5 PH A. v <br />JL'L <br />A <br />PR1'N-r 7/9/21 <br />DATE: <br />SCALE: 1/4"=1'-0" <br />SHEET <br />M1 <br />