Laserfiche WebLink
A R 6 N I T R 6 T i <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SECUENCE OF FLASHING TO BE, <br />X: <br />I. BOTTOM, 2. SIDES, 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />f: <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />i <br />WATER AWAY FROM JOINTS. <br />X± <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />4 <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, 4 CAULKING - JOINT <br />ALL AROUND <br />I I <br />I I <br />_ <br />PER SECTION R703.7 <br />I I <br />Exlerlor la ling and Dke ng <br />I I <br />Exterior use of pordand cement plaster <br />BACKER ROD <br />shall comply With the application <br />requirements of ASTM C 926-18b. <br />X. <br />.X: <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />' <br />orASTM 1787. <br />WRB LAYER -1, <br />STUCCO WRAP <br />HOODED VENT <br />THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />WOOD SHEATHING <br />LAYER M, <br />STUCCO WF2AP <br />LAYER'!, FORTIF15ER <br />BUfLDING PAPER <br />WOOp <br />CONSIUCTION <br />-METAL LATH <br />a' cm VINYL CASING DEAD <br />W RAISED BAND <br />V TO J9 MID -WALL <br />_ DEEP SCREED <br />61 WIDE STRIP SELF <br />ADHESIVE BASHING, CLEAN <br />MASONRY BEFORE AF'PI.YING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCKI <br />LEGEND <br />DRAINAGE PLANE (WR5 <br />LAYER 01, STUCCO WRAP) <br />WR5 LAYER 02 (FORTIF15ER — - — - — - — — <br />BUILDING PAPER) <br />METAL LATH X—X—X—X <br />STUCCO <br />WOOD OR 1/16" ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R'103.1.1 / ASTM C-841-14a, MIN. 2B L55. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />b' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUR DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT* <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER • <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />I <br />6' SELF ADHESIVE <br />FLASHING (INSTALL <br />PER MANUR SPECS.) <br />BUILDING PAPER <br />/ <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.TS. <br />ELEC. METEF <br />VERIFY LO <br />HICCK IV 1CCliCIVG <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />-ELEC. METER FIELD <br />�\ VERIFY LOCATION <br />WOOD CONSTRUCTION <br />WOOD SHEATHINGS <br />WR5 LAYER 01, <br />STUCCO WRAP <br />WR5 LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />j' THICK, 3 COAT CEMENT <br />PLASTER <br />V TO *V MID -WALL <br />WEEP SCREED <br />SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (U LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />�R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />:O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER ry, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT. <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEATHING <br />LAYER h, <br />STUCCO WRAP <br />LAYER 02, POWIP15ER <br />BUILDING PAPER <br />METAL LATH <br />WOOD 1/8' TEXTURED <br />CONSTRICTION . �— FINISH - WOOD <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER - l' O.C. MAX <br />a• GMI <br />A• TO )p MID -WALL <br />WEEP SCREED <br />5 <br />i <br />6' WIDE STRIP SELF <br />ADHESIVE FLAS14IN3, CLF_AN <br />CMASONRY BEPORE APPLYING <br />V FINISH - MASONRY <br />�B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />STEP #3 <br />8' <br />WRM LAYER el, <br />STUCCO WRAP <br />WRB LAYER M, <br />STUCCO UIRAP <br />APPLY 60 MIN <br />GRADE 'D' FELT <br />MEMBRAMBRAFLA NE SHING <br />FLA <br />® M—SELF-ADHERING <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />U1R5 LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />STEP #4 <br />AN ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />W!�j <br />STEP #5 STEP #ro <br />ELECTRICAL RECEPTACLE <br />Group <br />LONGWOOD, FL 32,jPH: 407-774-6078FAX:407-774-4078 <br />W W W.abdesigngroupx <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813886-2628 <br />FAX: 813886.2602 <br />�innuu <br />SUHDIV. & LOT <br />SILVERADO <br />LOT #9 <br />BLK 16 <br />PROJECT* <br />03719.001-09161 <br />MODEIA <br />2795-F <br />GARAGE SWING: <br />RIGHT <br />"'WALL <br />ALL <br />ASSEMBLY <br />DETAILS <br />150 EA B <br />