Laserfiche WebLink
w <br />Ab <br />FASCIA WOOD <br />BOARD BY OTHERS <br />© TRIM NAIL <br />INSTALLED THROUGH <br />70 STAPLES INSTALLED <br />FASCIA @ 16" O.C. MAX <br />THRU SOFFIT AND <br />J-CHANNEL AT NAIL <br />7O STAPLES INSTALLED <br />SOFFIT 1D HEM AND IN VALLEYS <br />THRU SOFFIT AT NAIL <br />HEM AND IN VALLEYS <br />STAPLES INSTALLED @ <br />12" O.C. MAX (INTO <br />® FASCIA <br />J-CHANNEL® (2)WOOD) IN J-CHANNEL <br />SLOT <br />" MAX. <br />DETAIL A <br />FASCIA <br />70 STAPLES INSTALLED @ <br />12" O.C. MAX (INTO <br />WOOD) IN J-CHANNEL <br />SLOT OR T-NAIL @ 12" <br />O.C. MAX. (INTO <br />CONCRETE/MASONRY) <br />}" MAX. <br />DETAIL D <br />J-CHANNEL <br />FASCIA <br />2X2 WOOD BATTEN 10 <br />TAPLESINSTALLED 70 <br />THRU SOFFIT AND <br />J-CHANNEL AT NAIL HEM <br />AND IN VALLEYS <br />#8XV' WOOD SCREW OR <br />TAPPING SCREW, <br />BATTEN ATTACHMENT <br />FASTENER SPACED 24" <br />MAX. O.C. <br />T"—SOFFIT 10 <br />J-CHANNEL 30 <br />70 STAPLESINSTALLED <br />THRU SOFFIT AND <br />J-CHANNEL AT NAIL <br />HEM AND IN VALLEYS <br />O SOFFIT <br />@ J-CHANNEL <br />k" MAX. <br />DETAIL E <br />J-CHANNEL <br />TRUSS/FRAMING OVERHANG EAVE CONSTRUCTION <br />—SPAN 'U—q._ I' —SPAN 'L=--_--%_ <br />SEE DETAIL'A' SEE DETAIL'E'_ �- <br />EAVE CROSS-SECTION <br />SINGLE SPAN W/J-CHANNEL <br />J-CHANNEL @ WALL, FASCIA @ FASCIA END <br />EAVE WIDTH <br />(ROOF <br />OVERHANG) <br />CONCRETE; <br />CMU OR WOOD <br />(NOTE:1) <br />SEE DETAIL'D'-" SEE DETAIL'E'--" — <br />EAVE CROSS-SECTION <br />SINGLE SPAN W/J-CHANNEL <br />J-CHANNEL @ WALL AND FASCIA END <br />BATTEN STRIP ANCHOR 12 <br />10d NAIL AT EACH <br />TRUSS/JOIST/ RAFTER <br />LOCATION NOT TO <br />EXCEED 24" O.C. INTO <br />FRAMING rTRUSS/JOI <br />/ BY OTHER <br />2-1/4" <br />EMB. <br />X2 WOOD BATTEN <br />L <br />�J-CHANNEL ® v DETAIL B <br />J-CHANNEL <br />FASCIA <br />12 BATTEN STRIP ANCHOR <br />10d NAIL AT EACH <br />TRUSS/JOIST/ RAFTER <br />LOCATION NOT TO <br />EXCEED 24" O.C. INTO <br />7O STAPLESINSTALLED- <br />THRU SOFFIT AND <br />J-CHANNEL AT NAIL <br />HEM AND IN VALLEYS <br />11 1X2 WOOD BATTEN <br />WOOD BATTEN @ <br />O SOFFIT <br />INSTALLATION SCREW, J-CHANNEL- <br />BATTEN ATTCHMENT ® i„ <br />FASTENER SPACED 24" 9O <br />MAX O.C. <br />/RAFTER <br />BY OTHER <br />2-1/4' NSTALLATION SCREW, <br />EMB. BATTEN ATTCHMENT <br />FASTENER SPACED 24" Og <br />MAX O.C. <br />,..,-STAPLES INSTALLED @ <br />12" O.C. MAX (INTO <br />70 WOOD) IN J-CHANNEL <br />O SLOT OR T-NAIL @ 12" <br />O.C. MAX. (INTO <br />CONCRETE/MASONRY) <br />,,,,-STAPLESINSTALLED @ <br />DETAIL C <br />12"O.C. MAX (INTO <br />7O WOOD) IN J-CHANNEL <br />J-CHANNEL CONCRETE/CMU OR <br />O SLOT OR T-NAIL @ 12" <br />WOOD (NOTE 1) <br />O.C. MAX. (INTO <br />CONCRETE/MASONRY) <br />CONCRETE/CMU OR <br />WOOD (NOTE 1) <br />NOTE 1: MINIMUM SPRUCE -PINE -FIR <br />FRAMING OR CONCRETE/MASONRY. <br />BUILING CODE REQUIREMENTS FOR <br />SUBSTRATE MATERIAL MUST BE MET. <br />ri{iiiiii is f' 13.519 <br />t iiii:•.• <br />EAVE WIDTH ii '•:' 375 ,375 <br />(ROOF i:3=' .49 3.625 3.625 3.6 <br />OVERHANG) <br />5 <br />\ .08 .03 <br />12- <br />"-CONCRETE, A <br />CMU OR WOOD —�— <br />(NOTEA) DETAILA <br />12" TRIPLE 4 FULL-0-VENT SOFFIT ECO <br />VINYL -NO. 639 <br />A 1 6 N I T 9 C T 6 <br />GrDesign r. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7748078 <br />FAX: 407-774.4078 <br />www.abdesigngmup.wm <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813-886-2628 <br />FAX: 813S86.2802 <br />SUSDIV. & Lo <br />SILVERADO <br />LOT #9 <br />BLK #16 <br />PRO.TECT# <br />03719.001-09161 <br />MODEL <br />2795-F <br />GARAGE SWING: <br />RIGHT <br />"tOFFIT <br />DETAILS <br />150 MPH A B <br />D. T? 06/09/21 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />SDI <br />