35963 Morse Willow Ct
Zephyrhills
>
Building Department
>
Building Plans
>
35963 Morse Willow Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:51:18 AM
Creation date
2/24/2025 9:43:49 AM
Metadata
Fields
Template:
Building Plans
Street #
35963
Location
Morse Willow Ct
Contractor
D R Horton
Building Plans - Permit #
2439
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LEGEND <br />SYM. <br />DESCRIPTION <br />-eft <br />TANDARD SWITCH <br />-WAY SWITCH <br />-44 <br />-WAY SWITCH <br />4 <br />IMMIER SWITCH <br />Im <br />SH BUTTON <br />)DISCONNECT <br />i <br />HERMOSTAT <br />INGLE RECEPTACLE (125v/20-AMP <br />INGLE POLE) <br />110V DUPLEX RECEPTACLE <br />10V DUPLEX RECEPTACLE (EQUIPPED <br />ITH GROUND FAULT <br />NTERUPTER/TAMPER RESISTANT TYPE) <br />10V DUPLEX OUTLET (HALF OF OUTLET <br />(RED TO SWITCH) <br />EXTERIOR WATERPROOF/GFI <br />RECEPTACLE (GROUND FAULT <br />NTERUPTER) <br />IOV QUADPLEX RECEPTACLE <br />® <br />10V D'UP Ex RECEPTACLE (FLOOR <br />20V RECEPTACLE (4 WIRE <br />ECTOR) <br />-0 <br />DEDICATED RECEPTACLE <br />1-O <br />VALL MOUNTED LIGHT <br />(LING MOUNTED LIGHT <br />-ENDANT LIGHT <br />LOOP LIGHT <br />ALL SCONCE PRE -WIRE <br />VENT FAN WITH LIGHT (I CFM PER SO. FT.) <br />P� <br />BULB LIGHT FIXTURE <br />9 <br />BULB LIGHT FIXTURE <br />Aaaana <br />BULB LIGHT FIXTURE <br />'T LIGHTING <br />TTIC LIGHT WITH PULL CHAIN <br />-( <br />ND CABINET LIGHT <br />® <br />'x4' FLUORESCENT LIGHT (RECESSED) <br />m <br />'x4' FLUORESCENT LIGHT (SURFACE <br />'11OUNT) <br />LIGHT (REGE98ED) <br />O <br />HT <br />GHT (VAPOR PROOF) <br />CRESCENT <br />UNTED LIGHT WITH J-BOX <br />AN <br />L PANEL (FIELD VERIFY <br />METER (FIELD V15RIFT_ <br />FQ <br />LL MOUNTED) <br />Q <br />-BOX (CEILING MOUNTED) <br />FILING MOUNTED FAN <br />B <br />VENT FAN (I am PER EQ. FT.) <br />PHONEJACK <br />b <br />ISMOKE DETECTOR (WALL MOUNTED) <br />OQ11OKE <br />DETECTOR (CEILING MOUNTED) <br />® <br />/C MONOXIDE— DE (TOR <br />II MOUNTED) <br />MIMES <br />® <br />I M D OUTLET FOR GARAGE <br />N R <br />TV <br />V JACK <br />'-mac <br />SB PORT <br />• LOG TON OF TV JACKS / PHONE OUTLETS 1 FAN5 <br />TO BE VERIFIED a HOMEOWNER <br />PRE -CONSTRUCTION MEETING. <br />• ALL 15 4 20 AMP BRANCH CIRCUITS TO BE ARC <br />FAULT PROTECTED PER ELECTRICAL PROVISIONS <br />OF FBCR '!eh EDITION M020) 1 NEC 210.12 201T <br />EDITION. <br />• 20 AMP DEDICATED LAUNDRY CIRCUIT. <br />• GFI • ISLAND (NOT ON KITCHEN CIRCUIT) <br />• DISHWASHER DISCONNECT TO BE LOCKOUT IN <br />PANEL <br />• BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY <br />OF 5o CFM INTERMITTENT PER ELECTRICAL <br />PROVISIONS OF SECTION M15013 FBCR 1th <br />EDITION (2020J <br />• LAUNDRY ROOM RECEPTACLE 5HALL BE GROUND <br />FAULT CIRCUIT -INTERRUPTER PROTECTION FOR <br />PERSONNEL ON FEEDERS <br />• WIRING METHOD SHALL BE NON METALLIC CABLE <br />PER ELECTRICAL PROVISIONS OF FBCR Tth ED <br />(2020). <br />• ALL WORK TO COMPLY WITH ELECTRICAL <br />PROVISIONS OF THE FBCR ITH ED (2020). <br />• ALL LAMPS SHALL BE SELECTED BY BUILDER <br />AND 15% OF LIGHTING MUST BE ENEMY EFFICIENT <br />TYPE PER FBG. ENERGY CONSERVATION <br />(RESIDENTIAL ENERGY EFFICIENCY) 2020. T1h <br />EDITION R404.1 <br />FM7 <br />---------------------------- <br />COVERED LANAI <br />PRE -WIRED <br />BEDROOM 1 j <br />CLG FAN <br />CAFE <br />I <br />I <br />L <br />Q <br />OPT. <br />1\ TXTURE <br />1 <br />I <br />I <br />I <br />/ <br />!` <br />50-S' <br />L <br />GPI <br />CLG FAN I <br />-----------------1- <br />�� �_--' Ok/ SD/COI <br />1 4'-0' 4'-4' <br />I SD. ---------------- <br />I Q <br />I <br />I\� GFI <br />GREAT ROOM <br />CL <br />1 I I <br />/ <br />/ I <br />-- <br />\ <br />I v <br />II <br />_ <br />I <br />4 <br />O <br />I W \1 <br />1 <br />I <br />DEWWIICCATE <br />cn <br />I I <br />BATH 1 <br />II <br />�( <br />OII7� IET <br />1 <br />PRE -WIRED <br />CLG FAN 1 <br />- - <br />�, <br />_ <br />wRR MIG 16 <br />------ v <br />LyTTrG� \\ <br />I 1\GF <br />I <br />/ <br />I <br />\ <br />�\ KITCHEN <br />I'--------------- <br />- I_-_____] <br />- <br />_� <br />I <br />I MULTI—GEN I <br />BEDROOM <br />______ ______ <br />-------------- <br />/ GPI <br />\ <br />I I <br />DINING <br />I ROOM/ <br />6 <br />I <br />1—JIL.T. <br />LAUNDRY <br />I I CLG FAN <br />CLG FAN <br />L-----------J II <br />{ <br />BEDROOM 3 <br />/ I <br />d <br />PRE -WIRED <br />CLG FAN <br />CLG FAN <br />BEDROOM <br />2 <br />ENTRY <br />ELECTRICAL PLAN <br />SCALE: 1/4' • 1'-0' <br />I io I' <br />I I <br />LED LIGHTING LED LIGHTING <br />C DOUBLE LAV. C SINGLE LAV. <br />BEDROOM 2 AND 3 BATH LAUNDRY ROOM BATH <br />r-----------------7 <br />--f ®��� MULTI—GEN <br />ISD/co\\ LIVING I <br />I \ ROOM I <br />I I <br />I CLG FAND I I I <br />L----------------- J <br />A i — — — — — — <br />JGFI 44' ! / <br />AFF. l 1 <br />GPI s 44' <br />A.F.F. <br />BOLLARD <br />ASREQ. / I <br />L---- J <br />PER BLDG. / I <br />/ <br />WALL MOUNTED <br />CODE i <br />/ I <br />LIGHT W/SWITCH IN <br />/ I <br />ATTIC <br />j I <br />3—CAR <br />/ I <br />GARAGE <br />I <br />I <br />\\ CLG. 'I OUTLETI <br />CLG. GFI OUTLET <br />\ FOR OPT. I <br />FOR OPT. <br />\GARAGE DOOR( <br />GARAGE DOOR <br />\ \ OPENER 1 <br />OPENER <br />P.B. FOR \ 1 <br />GFI <br />CHIMES \\ I <br />IRRIGATION <br />\ I <br />OUTLET <br />\, 1 <br />--------rt- <br />LED LIGHTING <br />LED LIGHTING <br />C SINGLE LAV. <br />Cap DOUBLE LAV. <br />MULTI-GEN BEDROOM BATH <br />BATH I <br />PROVIDE 3 2/0 CU. I % CU GNO 2" CONDUIT OR <br />PROVIDE 3 4/0 AL, 1 -4 AL GOD N 2" CONDUIT. <br />(C)NDUIT TO TEWINATE ABOVE SOFFIT OVERLWG.) <br />200 AMP ELECTRICAL RISER <br />NOT TO SCALE, <br />GENERAL NOTES, <br />COMBINATION 200 AMP <br />SERVICE G0/240 VOLT <br />A ELECTRICAL MATERIALS AND INSTALLATIONS <br />DISCONNECT I PHASE <br />SMALL COMPLY WITH ELECTRICAL PROVISIONS OF <br />M <br />SWITCH AND MLO <br />THE FBOR TTN EDITION (2020). LOCAL (.ODES, AND <br />ELECTRIC PANEL <br />ALL LOCAL POWER Ca'rANY REQ UREMENT& <br />METER N NEMA <br />B. ALL CONDUCTORS SMALL BE TYPE T"AI-MW <br />34R ENCLOSURE <br />2m <br />METER <br />UNLESS NOTED OTHERWISE. <br />cp <br />FIELD <br />VERIFY <br />TELEPENTRA11oNE LADLE <br />SERVICE <br />LOG. <br />POIER COMPANY <br />TRANSFORFIER <br />RQUIPYRNT INTTRANCE <br />INTERSYSTEM BONDING TERMINAL AT <br />GRADE <br />LOW VOLTAGE CONNECTIONS <br />PROVIDE 200 AMP, 120/240 VOLT. I PHASE — <br />1 -4 CU SERVICE CbROIND <br />SECONDARY ELECTRICAL SERVICE, PROVIDE 3 <br />CONNECTED TO CONCRETE <br />Oro COPPER (GU) IN Y' DIA SCHEDULE W PVC <br />ENCASED FOOTER STEEL PER <br />CONDUIT OR PROVIDE 3 -4/0 ALUMINUM (AL) IN <br />ELECTRICAL PROVISIONS OF <br />2" DIA SCHEDULE SO PVC CONDUIT UNLESS <br />FESCIR 'ITH EDITION (2020) <br />SERVICE IS PROVIDED BY THE ELECTRIC <br />�5CIA x S PT LONG COPPER <br />COMIPANY. COORDINATE WITH THE ELECTRIC <br />CLAD GROUND ROD <br />NY <br />COMPAPRIOR TO BID. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7748078 <br />FAX: 407-774�078 <br />www.abGealgngroup.com <br />A, N: 0003325 <br />DRAFTING BY: MOON <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813,886.262E <br />FAX: 813$66-2802 <br />3vBDIV. as LOT <br />SILVERADO <br />LOT #9 <br />BLK #16 <br />PROJECT# <br />03719.001-09161 <br />]MODEL: <br />2795-F <br />GARAGE SWUNG: <br />RIGHT <br />PAGE: <br />ELECTRICAL <br />PLAN <br />150 MPJiE <br />WTSF 06/09/21 <br />SCALE: 1/4"=1'—O" <br />3HEET <br />E1 <br />