Laserfiche WebLink
A-(i) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(9) 10d x 1 k' NAILS TO TRUSS <br />B-(2) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(12) 16d x 1 �' NAILS TO TRUSS <br />DEL STRAP, 1 EACH SIDE WRAPS UP AND <br />OVER TRUSS (NOT SHOWN) <br />C{1 SIMPSON LGT2 GIRDER TIEDOWN WITH <br />(16) 10d x 3 �' NAILS TO GIRDER AND <br />(2) SIMPSON HETA16 TRUSS ANCHORS <br />WITH (12) 16d x 3 k' NAILS TO GIRDER <br />lx2, 2x WOOD FASCIA <br />SEE ARCHITECTURAL <br />2x SECURED W/ (3) 16d <br />GALV. COMMON NAILS. <br />tx2 SECURED W/ 1Od <br />GALV. COMMON NAILS <br />12"O/C <br />MASONRY BOND BEAM <br />SEE SCHEDULE <br />PLYWOOD SHEATHING, SEE <br />"ROOFNJALUFLOOR <br />SHEATHING <br />FASTENER SCHEDULE" <br />NOTE: APTSYP#22"x4", <br />6", 8" x 4-0" MAY BE ADDED <br />W/ 10d NAILS, 2 ROWS, 3" <br />Or- TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE TRUSS <br />ANCHOR REQUIREMENTS. <br />ENGINEERED WOOD <br />TRUSSES 0 24" O/C, <br />SUBMIT SHOP DRAWINGS <br />FOR REVIEW <br />AND APPROVAL <br />A ALLOWABLE UPLIFT = U:1810 LBS, L:770 LBS (1 PLY) <br />B ALLOWABLE UPLIFT = U:2365 LBS, L:1430 LBS (2 OR 3 PLY) <br />C ALLOWABLE UPLIFT = U:2705 LBS (2 PLY) <br />STYPICAL TRUSS/ <br />1 B1" GIRDER CONNECTOR(S) SCALE:3/4"="' <br />3/4" T & G SUBFLOOR GLUED AND <br />SCREWED AS PER SCHEDULE <br />PRE-ENG FLOOR TRUSS <br />5/8" GYPSUM BOARD OR 1/2" HIGH <br />STRENGTH CLG, BOARD <br />SECURE TRUSS TO TOP PLATE W/ (2) <br />16d TOENAILS <br />DOUBLE TOP PLATE <br />ENGINEERED WOOD TRU <br />0 24" O/C, SUBMIT SHOP <br />DRAWINGS FOR REVIEW <br />AND APPROVAL <br />(1)SIMPSON HETA16 <br />TRUSS ANCHOR WITH <br />(9) 1 Od x 1 �' NAILS TO <br />GIRDER. PROVIDE 5" <br />MINIMUM CONCRETE <br />EMBEDMENT. USED IN <br />CONJUNCTION WITH <br />HEAVY UPLIFT <br />CONNECTOR <br />PLYWOOD SHEATHING, SEE <br />"ROOFNJALL/FLOOR <br />SHEATHING <br />FASTENER SCHEDULE" <br />NOTE: A PT SYP #2 Tx 4", <br />6", 8" x 4'-0" MAY BE ADDED <br />W/ 10d NAILS, 2 ROWS, 3' <br />O/C TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE GIRDER <br />TIEDOWN REQUIREMENTS. <br />GIRDER TIEDOWN <br />LGEN <br />TWIT <br />HE) TO <br />WITH (4) �" x 5" TITEN HD TO CMU AND (12) BIDS <br />(4) t' x " <br />�' x 2 }" TO GIRDER <br />B41) SIMPSON FGTR GIRDER TIEDOWN WITH <br />(2) �' x 5" TITEN HD TO CMU AND (18) SDS J" x <br />lx2, 2x WOOD FASCIA <br />3" TO GIRDER <br />SEE ARCHITECTURAL <br />2x SECURED W/ (3) 16d <br />C-(2) SIMPSON FGTR GIRDER TIEDOWNS WITH <br />GALV. COMMON NAILS. <br />(2) }'x 57ITEN HD TO CMU AND (18) BIDS �' x 3" <br />1x2 SECURED W/ 10d MASONRY BOND <br />SCREWS TO GIRDER (EACH TIEDOWN) <br />GALV. COMMON NAILS BEAM <br />ENSURE THAT CELLS ARE GROUTED <br />12" O/C SEE SCHEDULE <br />SOLID, 6' EACH WAY OF BOLTS <br />A ALLOWABLE UPLIFT = 3285 LBS (2 OR 3 PLY) <br />B ALLOWABLE UPLIFT = 4725 LBS (2 PLY MIN.) <br />C ALLOWABLE UPLIFT = 8885 LBS (2 PLY MIN.) <br />` TYPICAL ROOF <br />A�29B: It �92r. <br />GIRDER CONNECTOR(S) SCALE 34"=1'-0" <br />LSTA12 20 GAUGE <br />W/ 10dxl/2 HOG NAILS <br />EACH END. TOTAL OF 10 <br />FLOOR <br />GIRDER <br />M4 W/ 5/8" A.B. WITH <br />AIN, 7" EMBEDMENT <br />To SLAB & (18) 16d x <br />200R 216 WOOD BEARING <br />2-Il' NAILS TO POST., <br />WALL W/ SYP No 2 STUDS SEE <br />POST TO SIT DIRECTLY <br />PLANS FOR SPACING. SINGLE <br />ON SLAB <br />BTM. PLATE TO BE PT. <br />PROVIDE DBL. TOP PLATE <br />PROVIDE BLOCKING <br />. a < <br />1n" GYP. WL. BD. <br />a <br />`` <br />r.1GIRDER/WOOD POST CONNECTIONS <br />�_'�FLOOR TRUSS CONNECTION @ L.B.W. <br />-* SCALE:3/4"=V-0" (NO UPLIFT) <br />OUTER 1/3 OF <br />SPAN ONLY <br />BTM.— <br />PLATE <br />DEPTH 1/4°D <br />—HOLE EDGE >5/8" <br />-HOLE DIAMETER <br />2/5'0 SGL STUD <br />It HOLE EDGE 15/8" <br />HOLE DIAMETER <br />< 3/5•D DBL. STUD <br />STUD NOTCHING <br />(—.-,,AND BORING LIMITS <br />V SCALE: 1 to"=1'-0" <br />NOTE: <br />A- WHEN TRUSS BEAR ON TOP OF LEDGER USE SIMPSON HTS20 FROM <br />A - SIMPSON HUS28 G < 1200 LBS, U < 1260 LBS W/ (1) 3/4"° SIMPSON TITEN BOLT/J-BOLT, 5" MIN. <br />EMBED (22) 16d GALV. COMMON NAILS AND (8) 16d GALV. COMMON NAILS. <br />B - SIMPSON HUS28 G <2400 LBS, U < 1425 LBS W/ (2) 3/4"° SIMPSON TITEN BOLT/J-BOLT, 5" MIN. <br />EMBED (22) 16d GALV, COMMON NAILS AND (10) 16d GALV. COMMON NAILS. <br />C - SIMPSON HGUS28-2 G <2400 LBS, U < 1810 LBS W/ (2) 3/4"' SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS. <br />D - SIMPSON HGUS28-2 G < 4800 LBS, U < 1810 LBS W/ (4) 3/4"° SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS. <br />E - SIMPSON HGUS28-3 G < 4800 LBS, U < 1810 LBS W/ (4) 3/4"1 SIMPSON TITEN BOLT/J-BOLT, S' <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS. <br />WOOD LEDGER <br />9 ATTACHMENT DETAIL <br />SCALE: 3/4"=1'-0" <br /># 1100 UPLIFT SIMPSON — <br />HTSM20 W/10 10d TO <br />TRUSS AND (4) 114" x 2 114" <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br /># 1900 UPLIFT (2) SIMPSON <br />HTSM20 INSTALLED ON <br />OPPOSITE FACES OF <br />BLOCK WALL W/101Od TO <br />TRUSS AND (4)1/4" x 2 114" <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br />PRE-ENG TRUSS <br />CONTINUOUS BOND BEAM <br />TITEN 2 ANCHORS MIN. <br />7' COVER & 7' APART <br />REPAIR OF MULTIPLE <br />MISPLACED EMBEDDED TRUSS ANCHOR <br />3 SCALE: 3/4"=1' 0" <br />6'-0" MAX (W/1X4) <br />OR 10'-0" MAX (W/2X4) <br />(2) 2X4 No.2 SYP DIAG, <br />2x4 BLOCKING BETWEEN <br />BRACE W/ (3) 12d a EA. <br />TRUSSES WHERE <br />TRUSS (DIAG. BRACE TO <br />X-BRACING IS PRESENT AT <br />COVER 5 TRUSSES) <br />4'-0" O.C. (AT SHEATHING <br />0'-0" TO 30'-0" (1) W' BRACE <br />SEAMS) <br />30'-l" TO 60'-0 (3) "X" BRACE <br />SECURE 2x8 PT. PLATE <br />(1) "X" BRACE @CENTER <br />TO ELK W/ 1/2" DIA. <br />(2) 'X" BRACE DIVIDED EQUALLY <br />ANCHOR BOLT W/ 7' <br />FROM CENTER TO END. <br />WASHER SET IN HIGH <br />2x WOOD FASCIA, <br />STRENGTH EPDXY 6" <br />SEE ARCHITECTURAL <br />MIN. EMBED. AT 32" OC <br />MAX. <br />lx4 DIAGONAL <br />PRE-ENG GABLE TRUSS <br />SECURE GABLE TO 2x8 <br />BTM. CHORD <br />P.T. PLATE W/ 12d's 8" <br />BRACING, SEE <br />STIFFBACK (AS PER <br />O.C. MAX <br />PLAN FOR LOCATION <br />MAY NOT BE <br />TRUSS ENG) <br />CONT. 2x4 SECURED W/ <br />REQUIRED <br />(2) 10d's @ EACH TRUSS <br />TO BE INSTALLED <br />10'-0" O.C. MAX. <br />BTM. CHORD OF <br />WOOD ROOF TRUSSES <br />SEE SCHEDULE FOR <br />BOND BEAM REQ. ,. <br />lx4 BTM. CHORD BRACING 6'-O" O/C —/ —END WALL OR OTHER <br />MAX., OR 2x4 BTM. CHORD BRACING END TYPE CONDITION, IF <br />1V-0" O/C MAXSECURED W/ (2) 10d DEPICTED SEE PLAN <br />COMMON NAILS AT EACH CHORD <br />INTERSECTION TYP. �-� BTM. CHORD BRACING <br />6 <br />SCALE', 3W=T-0' <br />SEDGE <br />CENTRAL <br />SPACING <br />SPACING <br />SEE <br />SEE. <br />CHEDUL <br />SCHEDULE SEE FRAMING PLAN <br />SEE SCHEDULE FOR BOLT SIZE <br />SEE LEDGER SCHEDULE d <br />51/2" MIN. EMBED. (TYP) <br />1. ENSURE THAT EXP. BOLTS/J-BOLTS ARE <br />PLACED INTO GROUTED CELLS, 8" ALL AROUND <br />BOLT. <br />Z <br />2. END OF FRONT AND REAR LEDGER SHOULD <br />LAP A MIN OF 4'-0", <br />3. ALL BOLTS TO HAVE WASHERS <br />Z <br />4. EXP. BOLTS/J-BOLTS SHOULD NOT BE ANY <br />CLOSER THAN 6" O/C. <br />5, IN LIEU OF HILTI PAPS SIMPSON TITEN 14' <br />(2) PT <br />DIA. x W MASONRY SCREWS MAY BE USED, <br />RAM <br />LEDGER SCHEDULE <br />MARK <br />SIZE <br />BOLT SIZE <br />SEDGESPACING <br />CENTRALSPACING <br />A <br />DOUBLE 2x8 <br />1/2" <br />8" O/C <br />16" O/C <br />B <br />DOUBLE 2x8 <br />3/4" <br />8" O/C <br />24" O/C <br />C <br />DOUBLE 2x10 <br />1/2" <br />8" O/C <br />16" O/C <br />D <br />DOUBLE 2x10 <br />3/4" <br />8" O/C <br />24" O/C <br />E <br />DOUBLE 2x10 <br />3/4" <br />6' O/C <br />16" O/C <br />F <br />DOUBLE 2112 <br />3/4" <br />6' O/C <br />12" O/C <br />10 WOOD LEDGER DETAIL <br />SCALE: 3W*=l'-0" <br />BLOCK WALL W/ GABLE END <br />PRE-ENG'D TRUSS SCALE 3/4"=1'-0' <br />THE USE OF ALTERNATE MATERIALS MAY BE <br />USED SO LONG AS THEY CONFORM TO THE <br />FOLLOWING <br />1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS <br />A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS <br />EQUIVALENT OR GREATER UPLIFT AND LATERAL (F1 AND F2) LOAD CAPACITIES <br />AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND <br />ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE <br />THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO <br />A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, F1, AND F2 <br />FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE <br />SUBJECT TO F1 AND F2 FORCES. <br />11 ALTERNATE MATERIALS <br />SCALE: 3/4"=1'-0" <br />A R C N I T I C T E <br />6 <br />Gro sO <br />14i N. RONALD REAGAN BLV <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH:8134iM 628 <br />Iltit FAX: 81343.E 22 SO <br />stmDIv. & L,OT <br />SILVERADO <br />LOT #13 <br />BLK #16 <br />PROJECTtf# <br />03719.001-13161 <br />MODEX. <br />2795-D <br />GARAGE 8WING: <br />RIGHT <br />PAGE: <br />DETAILS <br />0 H EA j <br />JUL <br />rasE: <br />DATE: 07/09/21 <br />SCALM: 1/4"=1'—O' <br />BFIEET <br />S3.1A <br />