My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38299 Springhead Ln
Zephyrhills
>
Building Department
>
Building Plans
>
38299 Springhead Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 12:39:10 PM
Creation date
2/24/2025 10:13:19 AM
Metadata
Fields
Template:
Building Plans
Street #
38299
Location
Springhead Ln
Contractor
D R Horton
Building Plans - Permit #
3555
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 4999B7AA-F962-4606-810A-CEF053D4DE76 <br />TRADITIONAL HARD -COAT - <br />STUCCO INSTALLED IN <br />ACCORDANCE WITH THE <br />MANUFACTURER'S OR THE <br />PORTLAND CEMENT ASSC. <br />(PCA) RECOMMENDATIONS <br />WITH THE MOST <br />RESTRICTIVE <br />CONTROLLLING. <br />VERTICAL AND HORIZ <br />CONTROL JOINTS AS REQ'D <br />FASTEN ZIP SYSTEM <br />SHEATHING AS REQUIRED BY <br />ENGINEER -OF -RECORD AND/OR <br />LOCAL BUILDING CODE <br />TOP EDGE OF WEEP SCREED TAPED TO <br />WALL SHEATHING WITH ZIP SYSTEM® <br />TAPE OR ADHESIVE BACKED FLASHING <br />(MUST MEET AC148) <br />CODE -APPROVED VINYL WEEP <br />SCREED TO LAP CMU WALL MIN 2" <br />CMU MASONRY WALL <br />*ZIP SYSTEM@ SHEATHING IS APPROVED TO <br />REPLACE THE FIRST LAYER OF A TWO -LAYER <br />UNDERLAYMENT SYSTEM. <br />METAL LATH <br />ONE LAYER OF WATER -RESISTIVE <br />VAPOR -PERMEABLE BARRIER WITH A <br />PERFORMANCE AT LEAST EQUIVALENT <br />TO GRADE D BUILDING PAPER. <br />ZIP SYSTEM ® TAPE <br />(INSTALLED OVER ALL JOINTS <br />IN ZIP SYSTEM SHEATHING.) <br />WALL ASSEMBLY <br />VINYL/WOOD/FIBER CEMENT <br />SIDING (INSTALLED IN <br />ACCORDANCE WITH <br />CLADDING MANUF'S <br />INSTALLATION <br />RECOMMENDATIONS) ZIP <br />SYSTEMS ® SHEATHING <br />WOOD OR LT. GA. METAL <br />STUDS. <br />OVERLAP TAPE A MIN <br />1" AT ALL T-JOINTS <br />1/8" GAP RECOMMENDED AT 1/8" GAP RECOMMENI <br />PANEL EDGES PANEL EDGES <br />ZIP SYSTEMS ® SHEATHING WITH <br />HARD COAT STUCCO AT 2ND LEVEL <br />BLOCK TO FRAME TRANSITION) <br />ese construction details are provided to assist in the installation of Zip System ® product(s) <br />and may not apply to every situation. Manufacturer accepts no responsibility or liability for the use <br />of these or other construction details. <br />ZIP SYSTEM ® TAPE <br />(INSTALLED OVER AL <br />JOINTS IN ZIP SYSTEI <br />SHEATHING.) <br />OVERLAP TAPE A MIN <br />OF V AT ALL T-JOINT; <br />1/8" GAP RECOMMEN <br />FASTEN ZIP SYSTEM <br />REQUIRED BY ENGIN <br />AND/OR LOCAL BUILC <br />CMU N <br />"LIP SY51 LMU SHtA I HINU IJ Al't KUVLU I U <br />REPLACE THE FIRST LAYER OF A TWO -LAYER <br />UNDERLAYMENT SYSTEM. <br />ZIP SYSTEMS O SHEATHING WITH <br />LAP SIDING AT 2ND LEVEL <br />BLOCK TO FRAME TRANSITION) <br />hese construction details are provided to assist in the installation of Zip System ® product(s) <br />and may not apply to every situation. Manufacturer accepts no responsibility or liability for the <br />use of these or other construction details. <br />WALL ASSEMBLY <br />VINYLNVOOD/FIBER CEMENT <br />SIDING (INSTALLED IN <br />ACCORDANCE WITH <br />CLADDING MANUF'S <br />INSTALLATION <br />RECOMMENDATIONS) ZIP <br />SYSTEMS ® SHEATHING <br />WOOD OR LT. GA. METAL <br />STUDS. <br />1/8" GAP RECOMMENDED AT <br />PANELEDGES <br />ZIP SYSTEM ® TAPE (INSTALL <br />OVER ALL JOINTS IN ZIP SYST <br />SHEATHING.) <br />OVERLAP TAPE A MINIMUM OF <br />V AT ALL T-JOINTS <br />1/8" GAP RECOMMENDED AT I <br />FASTEN ZIP SYSTEM ® SHEA' <br />ENGINEER -OF -RECORD AND/( <br />*ZIP SYSTEM@ SHEATHING IS APPROVED TO <br />REPLACE THE FIRST LAYER OF A TWO -LAYER <br />UNDERLAYMENT SYSTEM. <br />ZIP SYSTEMS ® SHEATHING WITH <br />LAP SIDING AT SLAB ON GRADE <br />These construction details are provided to assist in the installation of Zip System 0 product(s) <br />and may not apply to every situation. Manufacturer accepts no responsibility or liability for the <br />use of these or other construction details. <br />TRADITIONAL HARD -COAT <br />METAL LATH <br />MORTAR SETTING BED ON <br />STUCCO INSTALLED IN <br />ONE LAYER OF WATER -RESISTIVE <br />TOP OF MORTAR SCRATCH <br />ACCORDANCE WITH THE <br />VAPOR -PERMEABLE BARRIER WITH A <br />COAT IN ACCORDANCE <br />MANUFACTURER'S OR THE <br />PERFORMANCE AT LEAST EQUIVALENT <br />WITH MANUFACTURER'S <br />PORTLAND CEMENT ASSC. <br />TO GRADE D BUILDING PAPER. <br />INSTALLATION <br />(PCA) RECOMMENDATIONS <br />ZIP SYSTEM@ SHEATHING* <br />RECOMMENDATIONS <br />WITH THE MOST <br />RESTRICTIVE <br />CONTROLLLING. <br />WOOD OR LT. GA. METAL STUDS <br />TOP EDGE OF WEEP SCREED <br />NATURAL OR MANUF <br />TAPED TO WALL SHEATHING WITH <br />STONE VENEER. <br />ZIP SYSTEM@ TAPE OR ADHESIVE <br />INSTALL IN <br />FOUNDATION <br />BACKED FLASHING. (MUST MEET <br />ACCORDANCE <br />AC148) <br />WITH MANUFACTURER'S <br />RECOMMENDATIONS <br />VERTICAL AND HORIZONTAL <br />° <br />FOUNDATION <br />CONTROL JOINTS AS NEEDED. <br />DESIGNER -OF -RECORD TO SPECIFY <br />a. ' <br />TYPE AND LOCATION. <br />DRIP EDGE FLASHING OR WEEP SCREED <br />IN ACCORDANCE WITH <br />CODE -APPROVED WEEP <br />a <br />MANUFACTURER'S <br />SCREED AT BASE OF WALL <br />RECOMMENDATIONS AT BASE OF ZIP <br />SYSTEM WALL SHEATHING <br />*ZIP SYSTEM@ SHEATHING IS APPROVED TO <br />REPLACE THE FIRST LAYER OF A TWO -LAYER <br />UNDERLAYMENT SYSTEM. <br />ZIP SYSTEMS ® HARD COAT <br />STUCCO AT SLAB ON GRADE <br />These construction details are provided to assist in the installation of Zip System ® product(s) and may not apply to <br />every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details. <br />ZIP SYSTEM@ SHEATHING.* <br />LATH <br />*ZIP SYSTEM@ SHEATHING IS APPROVED TO <br />REPLACE THE FIRST LAYER OF A TWO -LAYER <br />UNDERLAYMENT SYSTEM. <br />WOOD OR LT. GA. METAL STUDS <br />ONE LAYER OF WATER -RESISTIVE <br />VAPOR -PERMEABLE BARRIER WITH A <br />PERFORMANCE AT LEAST <br />EQUIVALENT TO GRADE D BUILDING <br />PAPER <br />TOP EDGE OF DRIP EDGE FLASHING <br />TAPED TO ZIP SYSTEM SHEATHING <br />SURFACE W/ ZIP SYSTEM TAPE OF <br />ADHESIVE <br />BACKED FLASHING. (MUST MEET AC148) <br />G ° . <br />ZIP SYSTEMS ® SHEATHING w/ <br />ADHERED STONE AT SLAB ON GRADE <br />These construction details are provided to assist in the installation of Zip System ® product(s) and may not apply to <br />everysituation, Manufacturer accepts no responsibility or liability for the use of these or other construction details. <br />L O <br />O <br />W APEX -C <br />U) U <br />W � <br />z_ <br />U <br />Z) C� <br />(If I <br />W <br />z_ <br />0 <br />z t S <br />W <br />Q true design studios (D <br />!Y <br />O <br />1 9000 REGENCY SQUARE BLVD. 4) <br />U- SUITE 100, JACKSONVILLE, FL 32211 <br />z0 904.821.5200 p <br />O Cr <br />a ® W <br />0 041HORION <br />0 ® o <br />E <br />O <br />J <br />IL <br />Q <br />U <br />z N <br />>_ <br />0 <br />O <br />_J <br />O <br />z <br />U <br />w <br />H <br />x <br />W <br />Uj U) <br />w <br />OC °° <br />z w <br />W O w <br />° <br />Q _ <br />w Q O <br />z � o <br />d' w w <br />O w w Q <br />00 <br />o <br />ILL <br />TML. <br />a <br />U) <br />_ x <br />0 <br />o ° <br />z w <br />= w <br />U z <br />Z <br />� Abbott Park a <br />x <br />w— — -- U— <br />M LOT 002-04-1 C w <br />Q -— J <br />U <br />w <br />PROJECT NO: I- <br />2021.014969 z <br />0 <br />DRAWN: <br />CD w <br />CHKD: JAC U— <br />O <br />0 <br />O <br />tr7 <br />w <br />J <br />U <br />U) <br />U) <br />O <br />z_ <br />r <br />12-29-2021 O <br />Z <br />REVISIONS: < <br />No. Description Date <br />Fn <br />- - --- - w <br />2 <br />w <br />J <br />Q <br />- - U <br />0 <br />A405 z <br />O <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.