My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38384 Springhead Ln
Zephyrhills
>
Building Department
>
Building Plans
>
38384 Springhead Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:27:42 PM
Creation date
2/24/2025 10:13:43 AM
Metadata
Fields
Template:
Building Plans
Street #
38384
Location
Springhead Ln
Contractor
D R Horton
Building Plans - Permit #
3335
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DoCuSign Envelope ID: 21E7372B-7C76-459C-AFD9-9AE48FD18COA <br />EXISTING EXTERIOR CMU - <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO - <br />MIN. 6" BELOW GRADE. WWF TO - - - <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/s' DIA. TAPCONS d <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />I EXISTING FOUNDATION. <br />D � <br />pI D <br />D \ <br />d <br />_n <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />' TO BOTTOM OF WINDOW SILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO ___ -._ <br />t. <br />EXISTING FOUNDATION FACE w/ p o - -- p P - -- a o -- <br />- D <br />(2) ROWS OF 3/s' DIA. TAPCONS / d <br />OR CUT NAILS @ 24" O.C. COVER D d <br />FLUSH w/ 3000psi CONCRETE. i <br />D - EXISTING FOUNDATION <br />r I <br />pl D D <br />I, <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />4 DEEP) <br />/ a d --T4„ <br />4' EXTENSION <br />UNDER BRICK VENEER <br />L"2NDER 1 STORY WALL VAPOR BARRIER <br />NDER 2 STORY WALL <br />(6: BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB h BLOCK W/ (1) #4 OR #5 CONT. <br />------- LU <br />Q a o <br />VAPOR BARRIER \\\/Uj <br />#4 OR #5 VERT REINFORCING <br />�// / <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. %/�/ /\/ Z/ , <br />\\// <br />FOOTING TO BEAR ON FIRM //� / ADDITIONAL #4 OR#5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. 14 <br />(BEYOND) <br />FLOATING CONCRETE w <br />SLAB W/ 64 W1.4xW1.4 <br />WWF OR FIBERMESH > -I <br />TT <br />• s D J <br />U-BLOCK W/ <br />J <br />(1)#4OR#5 <br />U) <br />CONT <br />w w <br />U) <br />o <br />FINISH <br />_ O <br />GRADE <br />\� ,U \\ \\\ \\\ <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. Q o Q <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL OR <br />#5 IN BRICK LEDGE <br />E <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />- o <br />\ O <br />VAPOR BARRIER \V <br />SEE NOTES (MAX 16") U <br />C. <br />STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" a, <br />0 <br />N <br />r7,. -, 4 "Im <br />ALL OTHER EXTERIOR WALL <br />CLADDING - MIN 8", U.N.O. ON ARCH <br />O <br />O <br />� <br />- - <br />p <br />APES0 <br />12" M I N \co <br />o <br />O <br />FOOTING TO BEAR ON 6" OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBEDSOIL LOCATIONS ON FND PLAN <br />N <br />CO <br />12" UNDER 1 STORY WALL w/ <br />NO. 5 <br />:2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR <br />J <br />BAR IN BRICK LEDGE <br />U_ <br />16" UNDER 2 STORY WALL w/ <br />:2) #5 OR (3) #4 CONTINUOUS <br />Jtds <br />N <br />z <br />true design studios <br />> <br />MONOLITHIC FOOTING SECTION <br />1 CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />O <br />FOLLOWING OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />Y <br />U <br />9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211 <br />vi <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY <br />0 <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. <br />O <br />SLAB w/ 6x6 <br />#4 OR #5 CONTINUOUS W1.4 x W1.4 WWFW ORCY <br />O <br />coCONCRETE <br />� <br />(2) (2) <br />♦- <br />_ <br />FIBERMESH <br />041HOMON' <br />d ° m <br />LLI <br />16" VAPOR BARRIER Q <br />L7 <br />3 BEARING WALL FOOTING SECTION Z <br />W <br />O <br />W <br />CONCRETE SLAB W/ 6x6 Of <br />W1.4 x W1.4 WWF OR This item has been electronically <br />FIBERMESH C) signed and sealed by Justin M Lanier, <br />0'-0" A.F.F. p PE on the date and/or time stamp <br />_ shown using a digital signature. <br />SEE ARCH Printed copies of this document are <br />8 - \ - d ti <br />° DETAILS �, not considered signed and sealed <br />d <br />° nd the signature must be verified <br />4- - - -d - ti by a 3rd Party Certificate Authority <br />8" MIN n any electronic copy <br />o Cn <br />\r Z LLJ <br />8"x8" THICKENED 8" U) Q <br />FTG AT � <br />BARRIER <br />STEP-DOWN, SEE VAPOR BAW <br />PLAN z W <br />4 CURB STEP SECTION m LLJ O <br />LU Q <br />W Q O <br />8" UNDER MASONRY WALL Z_ <br />6" UNDER WOOD WALL z Q <br />CONCRETE SLAB W/ W Q <br />W <br />6x6 W1.4 x W1.4 WWF LU <br />OR FIBERMESH VARIES = d 0 J <br />SEE ARCH Q (MAX 16") W W � ti <br />d O X <br />\\ \ LL L <br />�/\ d �,/ 12" MIN./\/\/\/\/\/ Z <br />Z <br />VAPOR BARRIERLLI <br />6 OPT. EXTENSION IN BRICK O �- <br />LOCATIONS ON FND PLAN a Z <br />12" UNDER 1 STORY WALL w/ <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR NO. 5 U <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ W <br />(2) #5 OR (3) #4 CONTINUOUS Abbott Park -' <br />O <br />U <br />GARAGE EXT WALL CURB SECTION <br />J <br />5 CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />Q <br />LOT 023-03-1 B <br />w <br />FOLLOWING OCCUR: <br />- <br />I-_ <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />U <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY <br />Z <br />Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY <br />0 <br />PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. <br />W <br />O <br />PROJECT NO: <br />LUU <br />CONCRETE SLAB W/ 6x6 <br />J <br />2021.012592 <br />LL <br />W1.4 x W1.4 WWF OR <br />O <br />0 <br />FIBERMESH <br />Z <br />DRAWN: <br />0'-0" A.F.F. SEE ARCH <br />2 <br />CD <br />-- U o <br />d - - -- - - - - (MAX 20" W - � <br />CMU STEMWALL MONO LITHIC SLAB Q d _ - _ DEEP) CHKO: <br />3'/z' CONCRETE SLAB W/ 6x6 ,\ ACT\\ 4 d MJP <br />-.. - (1) #4 OR #5 CONT. W1.4 x W1.4 WWF OR FIBERMESH r, // // ° ° 4 X - <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. \�\\\\\//�\ \ a 0,6 Q Q <br />INTO MONOLITHIC THICKENED EDGE _ <br />\ // i4 4" EXTENSION X U <br />MIN 24" LAP d ° a <br />36" MAX VARIES PER -- a - - - - - - - UNDER BRICK VENEER < ��`t�IN 1 11 111 CA <br />4" CONCRETE SLAB W/ ARCH PLANS ° d A \ \ , ,� J .•••••.••N/�. <br />//\//\/�\//\\/\\ 5 i <br />C� <br />6x6 W1A x W1.4 WWF _--•T /\/� �' 12" UNDER 1 STORY WALL } �� �(', E IDS'• 9 i� Z <br />OR FIBER MESH\/T/\\ w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m � • �, �••.• <br />-d- 12" MIN VAPOR BARRIER 16" UNDER 2 STORY WALL LLI * NO 85166 <br />w Z s < s \\ \\ \ \ d d \ FOOTING TO BEAR ON FIRM Z ooc Signed by: <br />Q <br />w O ° d • • #4 OR #5 %/ /// /// / // d' • / UNDISTURBED SOIL w/ (3) #4 OR (2) #5 CONT r <br />e . °d REINFORCING PER \\�\\.\/.\� O : i�Fa3�,�' �. <br />U Z ° I d ° • MONOLITHIC FOOTING BEARING CURB STEP SECTION <br />v� SECTION b _. •(� •. • <br />n < 6" OPT. EXTENSION W � 0 •• T �� <br />O R O,. �. <br />° d IN BRICK LOCATIONS �� � ' ' <br />• D < • d FOOTING TO BEAR ON FIRM ON FND PLAN ¢ �� sS' • • �� �� Z <br />°4. UNDISTURBED ._ � a ° _ UNDISTURBED SOIL #4 OR UNDER <br />#5 CONTSTORY WALL W% (2) _ ��N A� E %�%` <br />\ \ ° \ \ ADDITIONAL N0.4 OR NO. 5 ( ) <br />° d ° MIN12" //\//\//\//\//\//\//\ BAR IN BRICK LEDGE TYPICAL REINFORCING <br />`• 16" UNDER 2 STORY WALL W/ (3) BARSFOOTATTHICKENEDSEE O 11-01-2021 p <br />• a4 /\/\�/� #4 OR (2) #5 CONT F- W <br />a •-- - a -• - •--\\�\\�\\%/\\%//\ �� I MIN 24LONG #4 OR #5 I- CO <br />" <br />U REVISIONS: W <br />BAR SET AT MID -DEPTH - 2 <br />//\//\//\//\//\//\//\// //\//\//\// • STEMWALL FOOTING TO EXTEND MIN OF SLAB, TYP ALL < Q p No. Description Date ~ <br />12" BELOW MONOLITHIC FOOTING "NOTE'': IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "'I" � � RE-ENTRANT CORNERS - W <br />- <br />•ADDITIONAL #4 OR #5 VERTICAL TO BE FTG DETAIL SPECIFIED ON THE FDN PLAN @ANY LOCATIONS THAT THE FTG .J <br />� _ - _ - - _ - � Q <br />LOCATED WITHIN TRANSITION ZONE DEPTH EXCEEDS 28". - <br />LOCATE AND TIE INTO STEMWALL FOOTING U) <br />REINFORCEMENT IN LAST REINFORCEMENT IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE L -_ -_ - -_ -- - - - - - - --- _ <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />STEMWALL CELL - - - - - - - - - � ~ <br />TWO CHOICES: -- O <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION HOUSE SLAB Z Z <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL OF SOIL. <br />2. USE STEMWALL FOOTING = O <br />RE-ENTRANT CORNER DETAIL U <br />fn <br />(RECOMMENDED) 17- <br />PLAN VIEW, DETAIL TYPICAL @ ALL W T=2mD <br />RE-ENTRANT CORNERS IZ <br />CMUIMETAL CONNECTOR ENGINEERINGa <br />11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.