My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38405 Springhead Ln
Zephyrhills
>
Building Department
>
Building Plans
>
38405 Springhead Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:15:48 PM
Creation date
2/24/2025 10:14:08 AM
Metadata
Fields
Template:
Building Plans
Street #
38405
Location
Springhead Ln
Contractor
D R Horton
Building Plans - Permit #
3329
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 422E4585-AB15-48C1-AF50-1025F7A8ADD7 <br />0 <br />0 <br />04 r <br />u7 E <br />O <br />� U <br />4 cy <br />O O <br />APEX0 <br />r- U <br />N <br />M <br />J <br />LL � <br />W <br />J <br />J_ <br />� Q <br />z r <br />Otds <br />0 true design studios j <br />O <br />O <br />9000 REGENCY SQUARE BLVD.Lij <br />N <br />SUITE 100, JACKSONVILLE, FL 32211 <br />cn <br />O_ <br />U <br />1 J U <br />Lij <br />041HOOON D <br />ELECTRIC METER < <br />/ \ ELECTRIC METER 1 FIELD VERIFY LOCATION t I rz <br />/ FIELD VERIFY I <3 <br />LOCATION APPLY STUCCO SCRATCH COAT AND ONE (1) <br />JOINT W/ STRIP LATH <br />PRE FORMED CONTROL 5/8" CEMENT PLASTER LAYER OF PAINT PRIOR TO INSTALLING ELECTRIC % <br />/ — <br />12" WIDE SELF-ADHESIVE METER Z <br />FLASHING CENTERED UNDER • I W -c <br />--' T <br />TROL JOINT (CLEAN U' I CAVITY TO BE FILLED <br />+� M.'�`•• ' : � CON-p <br />MASONRY BEFORE APPLYING) WITH RIGID POLYMERIC W <br />° ISOCYANOTE-POLYBLEN of O <br />/ FOAM ("GREAT STUFF" OR 00 <br />-- SIMILAR) 0 <br />0 <br />/IV APPLY A SILICON BASE <br />STUCCO FINISH SEALANT AT POINT THAT <br />LO <br />'T ` __ __ ELEC WIRE PENETRATES <br />5/8" CEMENT PLASTER / <br />/ 6" SELF ADHESIVE <br />_ 12" WIDE SELF-ADHESIVE L OVER TOP & SIDES Z <br />FLASHING CENTERED UNDER / _ <br />CONTROL JOINT (CLEAN \ SELF FLASHING • W <br />MASONRY BEFORE APPLYING) /LO <br />' UNIT > W <br />-- PROVIDE STUCCO Z <br />PRE -FORMED CONTROL - . - - SCRATCH COAT LARGER (n <br />JOINT W/ STRIP LATH <br />• THAN THE ELECTRIC w <br />/ PREMANUF. METER CAN OR METER m <br />\ DRYER VENT CAP - CAN COMBO OR METER <br />` _ / (SET IN CONT. AREA TO RECEIVE CAN AND DISCONNECT W <br />8" CMU }�,. SEALANT) STUCCO SCRATCH COAT W W <br />SEALANT at & 1 COAT <br />TOP & SIDES BACK ROLL PRIOR OF PAINT / (� <br />ELECTRIC METER Z <br />INSTALLATION w C <br />Of <br />O <br />CONTROL JOINT - HORIZ - CMU CONTROL JOINT - VERTICAL - CMU DRYER VENT (BLOCK) ELECTRICAL CONDUIT PENETRATION ° 0 <br />SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. zw <br />0 <br />I.LI Q <br />F- fl� 0 <br />w <br />O �-1- <br />r2 <br />WOOD CONST BEYOND Iv <br />IBERCEMENT -OR- VINYL LAP <br />WOOD SHEATHING IDING OVER APPROVED O X <br />6" SELF -ADHERING WEATHER RESISTIVE ; • OUSEWRAP INSTALLED PER U T_ <br />FLASHING BARRIER #1 FINISH COATING OVER PRIMED FR WRITTEN SPECIFICATIONS Q <br />` THREE COAT STUCCO FINISH XTEND HOUSEWRAP Z <br />WEATHER RESISTIVE WEATHER RESISTIVE (718' NOM) OVER GALV MTL LATH <br />WD SHEATHING VER NAILING FLANGE 0 O <br />BARRIER #1 BARRIER #2 OVER 15# FELT OVER APPROVED �VINYL ANGLED Q \ \ (RE: STRUCT) : HOUSEWRAP WD SHEATHING LJL WCASING BEAD WEATHER RESISTIVE\ (RE: STRUCT)Q Z <br />(AM66-ANGLED-1250) BARRIER #2 \ 5/16" X 7 1/4" LAPSIDING W/ 6 REVEAL_ FASTEN TO WD STRUCTURAL MEMBER at 7" O.C. MAX TL DRIP FLASHING W/ <br />STARTER STRIP 7, " TO MID -WALL <br />EMMED EDGE SET IN CONT U 112 1/2" a- / 8 EAD OF SEALANT Z LL. <br />/ EP SC 8" CMU CORNERBEAD DO NOT CAULK OR RIM (RE: ELEVATION) � <br />_ WE <br />(FASTENER & 6" SELF -ADHERING _ SEAL OPENING (� J <br />z o - -- - SPACING at 7"O.C.) FLASHING / " N g _j EXTEND 12" SELF -ADHERING 0 Q <br />a �y �T�,• . - MEMBRANE FLASHING OVER J __ () <br />°° a GALV D METAL GALV'D METAL 7' WINDOW FLANGE SET IN CONT O <br />U) c4 "Z" FLASHING FLASHING 6" WIDE STRIP SELF ADHESIVE BEAD OF SEALANT Z <br />LlJ w w �' y FLASHING, CLEAN MASONRY 2 0 <br />> _ _- - DO NOT CAULK OR W <br />--- <br />SEAL OPENING 1 1/4" X 6" SIMULATED - �,. BEFORE APPLYING -- - VINYL FLANGE CASING BEAD U PROJECT NO: Q <br />j WOOD TRIM MEMBER c __ . INSTALLED PER MFR LLI <br />/ e 1/2" (MIN) STUCCO FINISH WRITTEN SPECS (TYP) z <br />/ STUCCO ?" TEXTURED PER COMMUNITY X (� <br />CMU 1 1/4" X 6" SIMULATED : ' 1/2" (MIN) STUCCO FINISH W -" <br />CASING BEAD SPECIFCATIONS DRAWN: <br />-- VINYL CASING WOOD TRIM MEMBER .. ,• TEXTURED PER COMMUNITY a MJp w <br />BEAD (AM66-1250) 1/2" (MIN) STUCCO FINISH _ ' '~. SPECIFCATIONS Q <br />1/2" (MIN) TEXTURED TEXTURED PER COMMUNITY SEAL GAP W/ CAULKING - X CHKD: LL <br />FINISH at MASONRY SPECIFCATIONS Q <br />OR APPROVED SEALANT /, -, TSD O <br />STUCCO CASING BEAD !� STUCCO SIDING m O <br />LO <br />RAISED BAND at BLOCK CORNER BEAD at BLOCK SIDING TO STUCCO HORIZONTAL MATERIAL TRANSITION (FRAME TO BLOCK) LIj <br />Z <br />SCALE: N.T.S. SCALE: N.T.S. FRAME TO BLOCK SCALE: N.T.S. 0 Q <br />SCALE: N.T.S. W <br />z <br />z <br />o Q <br />1/2" (MIN) STUCCO 1 CMU WALL W/ SELF ADHESIVE -OR- FLUID CMU WALL W/ H <br />APPLIED PAN FLASHING (CLEAN <br />FINISH TEXTURED §8' STUCCO FINISH CMU LINTEL 1/2" (MIN) STUCCO FINISH U ' <br />MASONRY BEFORE APPLYING) <br />PER COMMUNITY (RE: STRUCTURAL) (RE: STRUCTURAL) (RE: STRUCTURAL) ILL <br />SPECIFCATIONS "GYP BIRD OVER '• "GYP BIRD OVER EXTEND UP AT JAMBS (4" MIN) 1�" GYP BRD OVER" GYP BIRD OVER (� <br />PRE -SHAPED STUCCO BAND 'h <br />1x2 TREATED W/ SLP TOP INSTALLED PER 1x2 TREATED PRE -SHAPED STUCCO BAND <br />1x2 TREATED 1x2 TREATED � Z <br />W/ INSTALLED PER MFR FURRING STRIPS FURRING STRIPS <br />FURRING STRIPS MFR WRITTEN SPECS (RE: FURRING STRIPS WRITTEN SPECS (RE: ELEV) <br />FLANGE CASING at CMU WALL (TYP) ELEV) at CMU WALL (TYP) PRECAST CONCRETE SILL at CMU WALL (TYP) OFSEALANTSEALANT NTINUOUS BEAD at CMU WALL (TYP) OF O SEALANT NTINUOUS BEAD } REVISIONS: <br />BEAD SELF ADHESIVE -OR- FLUID SELF ADHESIVE -OR- FLUID PT 1 x4 0 - <br />APPLIED FLASHING (CLEAN WOOD BLOCKIN APPLIED FLASHING (CLEAN fie" BACKER ROD W/SEALANT PT 1x4 SELF ADHESIVE -OR- SELF ADHESIVE -OR- 0 0 <br />J No. Description Date <br />MASONRY BEFORE APPLYING) MASONRY BEFORE APPLYING) VINYL FLANGE CASING BEAD FLUID APPLIED PT 2x4 FRAME FLUID APPLIED - - W <br />GYP BIRD OVER INSTALLED PER MFR PT 2x4 FRAME ANCHOR ANCHOR 0 <br />PT 1x WOOD BUCK VINYL FLANGE CASING BEAD PT 1x WOOD BUCK VINYL FLANGE CASING BEAD FLASHING (CLEAN FLASHING (CLEAN Z (� <br />1x2 TREATED WRITTEN SPECS (TYP) SHIM AS NEEDED MASONRY BEFORE MASONRY BEFORE - _ - --- LLI <br />SHIM AS NEEDED INSTALLED PER MFR SHIM AS NEEDED INSTALLED PER MFR FURRING STRIPS q�p�YING, SHIM AS NEEDED METALI DOOR FRAME U - i- <br />WRITTEN SPECS (TYP) WRITTEN SPECS (TYP) CMU STEMWALL W/ METAL DOOR FRAME <br />at CMU WALL (TYP) §8" STUCCO FINISH W <br />48" BACKER ROD W/ SEALANT 48' BACKER ROD W/ SEALANT (RE: STRUCTURAL) INTERIOR EXTERIOR INTERIOR EXTERIOR J <br />INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR W - U <br />CASING BEAD at WN WINDOW HEAD at CMU WINDOW JAMB at CMU WINDOW SILL at CMU DOOR HEAD at CMU DOOR JAMB at CMU Q <br />0 <br />SCALE: N.T.S. SCALE: 1 ti2" = 1'-0" SCALE: 1 ti2" = 1'-0" SCALE: 1 i2" = 1'-0" SCALE: 1 ti2" = 1'-0" SCALE: 1 1/2" = 1'-0"AOU 1 z <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.