DocuSign Envelope ID: 8667BF40-1EF6-46CB-B392-335A2B4525A6 <br />TRUSS TO TOP PLATE, MOISTURE BARRIER/ <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/H8ORH10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2. <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1 <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 12" IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1 <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />I <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />I I <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />BOTTOM PDT ANCHOR g PROVIDE DOWELS TO MATCH <br />THREADED ROD ANCHOR W/MIN 4" _ <br />EMBED W/ NUT & WASHER IN SIMPSON M I I VERTICAL WALL <br />ACRYLIC -TIE OR EQUIVALENT z REINFORCING W/ MIN 30" LAP <br />ADHESIVE @ MAX 48" O.C. (IF DOWEL IS OMITTED OR <br />OR I I IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />'/z' WEDGE BOLT W/ MIN 4'/2" EMBED W/ EQUAL SIZE W/ MIN. 6" <br />WASHER @ MAX 48" O.C. I I EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />4 4 j //\� \\\/\\ ° d \° <br />BOTTOM PLATE ANCHOR NOTES d <br />• EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />• INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />TYI <br />ROOF -TO' <br />CONNEC <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN 1V32" EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 k2" <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF ( RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />FOR MISLOCATIO <br />FASTEN 2x6 NO. 2 <br />TO TRUSS W/ MIN ( <br />FOR MISLOCATIOI <br />INSTALL NEW MAS <br />STRAP TO INSIDE <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />f CORNERS <br />CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />POURED CELL w #5 BAR CONT <br />FROM BEAM TO FOOTING <br />STEP DOWN TIE -BEAM <br />DIST. FROM DOORJAMB <br />/ WINDOW TO BLOCK <br />MIN. SCREW <br />LENGTH <br />DIST. FROM DOORJAMB <br />/ WINDOW TO BLOCK <br />MIN. SCREW <br />LENGTH <br />OR 11/4' <br />PER MANUF. <br />3" <br />5" <br />11/2 <br />3%-- <br />37 <br />5„ <br />11,16 <br />3 3/4" <br />3 3/4 <br />6„ <br />2 %4, <br />33/4" <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS '/:' DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS 3/6' DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED 11/:") <br />1x_ PT NAILER <br />BUILT UP 2X_ATTACHED TO MASONRY, (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOOR/VVINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />I- <br />ti <br />O <br />U) <br />U) <br />W <br />Z <br />U) <br />m <br />W <br />W <br />z <br />0 <br />W <br />0 <br />U_ <br />_O <br />H <br />O <br />a. <br />0 <br />U <br />0 <br />FE <br />O <br />J <br />LL <br />Q <br />U <br />Z <br />0 <br />O <br />J <br />O <br />z <br />U <br />W <br />H <br />W <br />a. <br />Q <br />m <br />O <br />LLI <br />O <br />U <br />U_ <br />Q <br />W <br />0 <br />J <br />O <br />z <br />2 <br />U <br />W <br />x <br />W <br />a. <br />Q <br />O <br />U <br />>O <br />APEXO <br />U <br />O <br />tds <br />true design studios N <br />9000 REGENCY SQUARE BLVD. N <br />SUITE 100, JACKSONVILLE, FL 32211 <br />904.821.5200 p <br />=n <br />This item has been electronically <br />signed and sealed by Justin M Lanier, <br />PE on the date and/or time stamp <br />shown using a digital signature. <br />Printed copies of this document are <br />not considered signed and sealed <br />■and the signature must be verified <br />■by a 3rd Party Certificate Authority <br />n any electronic copy <br />W <br />v <br />W <br />0. <br />Z <br />W <br />O <br />cn <br />J <C <br />p <br />W <br />Q <br />J <br />W <br />ti <br />x <br />0 <br />0 <br />W <br />H <br />Z <br />Abbott Park Of <br />a- <br />- LL <br />LOT 027-03-1 B W <br />Q <br />U <br />co <br />13 <br />W <br />PROJECT NO: F- <br />2021.012596 z <br />- 0 <br />DRAWN: U) <br />CD W <br />CHKD: <br />MJP 0 <br />0 <br />0 <br />LO <br />,,*ttt,tt,fui►�� U) <br />�. JSj iN LAN��.,� <br />♦ • • �i <br />�•'��� E NsF•R a <br />' U <br />No 85166 W <br />w <br />Doc*Signed by: Ur <br />:�O•'. • <br />Z <br />STATE OF .3:�i <br />�, /E ��S'I,O N A ,` C,. <br />. 0 <br />11-01-2021 O <br />z <br />REVISIONS: <br />No. Description Date <br />-- - W <br />LU <br />W <br />_ J <br />Q <br />U <br />H <br />O <br />ST=5 Z <br />O <br />CMUIMETAL CONNECTOR ENGINEERING <br />