My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38416 Springhead Ln
Zephyrhills
>
Building Department
>
Building Plans
>
38416 Springhead Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:41:52 PM
Creation date
2/24/2025 10:14:21 AM
Metadata
Fields
Template:
Building Plans
Street #
38416
Location
Springhead Ln
Contractor
D R Horton
Building Plans - Permit #
3332
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t •y-. <br />DocuSign Envelope ID: 8667BF40-1EF6-46CB-B392-335A2B4525A6 <br />TRADITIONAL HARD-COXF- <br />STUCCO INSTALLED IN <br />ACCORDANCE WITH THE <br />MANUFACTURER'S OR THE <br />PORTLAND CEMENT ASSC. <br />(PCA) RECOMMENDATIONS <br />WITH THE MOST <br />RESTRICTIVE <br />CONTROLLLING. <br />VERTICAL AND HORIZ <br />CONTROL JOINTS AS REQ'D <br />FASTEN ZIP SYSTEM ID <br />SHEATHING AS REQUIRED BY <br />ENGINEER -OF -RECORD AND/OR <br />LOCAL BUILDING CODE <br />TOP EDGE OF WEEP SCREED TAPED TO <br />WALL SHEATHING WITH ZIP SYSTEM® <br />TAPE OR ADHESIVE BACKED FLASHING <br />(MUST MEET AC148) <br />CODE -APPROVED VINYL WEEP <br />SCREED TO LAP CMU WALL MIN 2" <br />CMU MASONRY WALL <br />*ZIP SYSTEM® SHEATHING IS APPROVED TO <br />REPLACE THE FIRST LAYER OF A TWO -LAYER <br />UNDERLAYMENT SYSTEM. <br />METAL LATH <br />ONE LAYER OF WATER -RESISTIVE <br />VAPOR -PERMEABLE BARRIER WITH A <br />PERFORMANCE AT LEAST EQUIVALENT <br />TO GRADE D BUILDING PAPER. <br />ZIP SYSTEM ® TAPE <br />(INSTALLED OVER ALL JOINTS <br />IN ZIP SYSTEM SHEATHING.) <br />WALL ASSEMBLY <br />VINYL/WOOD/FIBER CEMENT <br />SIDING (INSTALLED IN <br />ACCORDANCE WITH <br />CLADDING MANUF'S <br />INSTALLATION <br />RECOMMENDATIONS) ZIP <br />SYSTEMS 0 SHEATHING <br />WOOD OR LT. GA. METAL <br />STUDS. <br />OVERLAP TAPE A MIN <br />1" AT ALL T-JOINTS <br />1/8" GAP RECOMMENDED AT 1/8" GAP RECOMMENI <br />PANELEDGES PANELEDGES <br />ZIP SYSTEMS ® SHEATHING WITH <br />HARD COAT STUCCO AT 2ND LEVEL <br />Bese LOCK TO FRAME TRANSITION) <br />construction details are provided to assist in the installation of Zip System ® product(s) <br />and may not apply to every situation. Manufacturer accepts no responsibility or liability for the use <br />of these or other construction details. <br />ZIP SYSTEM ® TAPE <br />(INSTALLED OVER AL <br />JOINTS IN ZIP SYSTEI <br />SHEATHING.) <br />OVERLAP TAPE A MIN <br />OF 1" AT ALL T-JOINT! <br />1/8" GAP RECOMMEN <br />FASTEN ZIP SYSTEM <br />REQUIRED BY ENGIN <br />AND/OR LOCAL BUILE <br />CMU M <br />"LIV 5Y5 1 tM (D 6t1tzA I HINU 15 At' KUVtU I U <br />REPLACE THE FIRST LAYER OF A TWO -LAYER <br />UNDERLAYMENT SYSTEM. <br />ZIP SYSTEMS ® SHEATHING WITH <br />LAP SIDING AT 2ND LEVEL <br />(BLOCK TO FRAME TRANSITION) <br />These construction details are provided to assist in the installation of Zip System®product(s) <br />and may not apply to every situation. Manufacturer accepts no responsibility or liability for the <br />use of these or other construction details. <br />WALL ASSEMBLY <br />VINYL/WOOD/FIBER CEMENT <br />SIDING (INSTALLED IN <br />ACCORDANCE WITH <br />CLADDING MANUF'S <br />INSTALLATION <br />RECOMMENDATIONS) ZIP <br />SYSTEMS ® SHEATHING <br />WOOD OR LT. GA. METAL <br />STUDS. <br />1/8" GAP RECOMMENDED AT <br />PANELEDGES <br />ZIP SYSTEM ® TAPE (INSTALL <br />OVER ALL JOINTS IN ZIP SYST <br />SHEATHING.) <br />OVERLAP TAPE A MINIMUM OF <br />1" AT ALL T-JOINTS <br />1/8" GAP RECOMMENDED AT F <br />FASTEN ZIP SYSTEM ® SHEA' <br />ENGINEER -OF -RECORD ANDK <br />*ZIP SYSTEM® SHEATHING IS APPROVED TO <br />REPLACE THE FIRST LAYER OF A TWO -LAYER <br />UNDERLAYMENT SYSTEM. <br />ZIP SYSTEMS ® SHEATHING WITH <br />LAP SIDING AT SL <br />AB ON GRADE <br />These construction details are provided to assist in the installation of Zip System ®product(s) <br />and may not a Iyy to every situation. Manufacturer accepts no responsibility or liability for the <br />use of these or other construction details. <br />TRADITIONAL HARD -COAT - <br />STUCCO INSTALLED IN <br />ACCORDANCE WITH THE <br />MANUFACTURER'S OR THE <br />PORTLAND CEMENT ASSC. <br />(PCA) RECOMMENDATIONS <br />WITH THE MOST <br />RESTRICTIVE <br />CONTROLLLING. <br />FOUNDATION —� <br />VERTICAL AND HORIZONTAL <br />CONTROL JOINTS AS NEEDED. <br />DESIGNER -OF -RECORD TO SPECIFY <br />TYPE AND LOCATION. <br />CODE -APPROVED WEEP <br />SCREED AT BASE OF WALL <br />METAL LATH <br />MORTAR SETTING BED <br />ONE LAYER OF WATER -RESISTIVE <br />TOP OF MORTAR SCRATCH <br />VAPOR -PERMEABLE BARRIER WITH A <br />COAT IN ACCORDANCE <br />PERFORMANCE AT LEAST EQUIVALENT <br />WITH MANUFACTURER'S <br />TO GRADE D BUILDING PAPER. <br />INSTALLATION <br />ZIP SYSTEM® SHEATHING* <br />RECOMMENDATIONS <br />*ZIP SYSTEM® SHEATHING IS APPROVED TO <br />REPLACE THE FIRST LAYER OF A TWO -LAYER <br />UNDERLAYMENT SYSTEM. <br />.4. <br />WOOD OR LT. GA. METAL STUDS <br />TOP EDGE OF WEEP SCREED <br />TAPED TO WALL SHEATHING WITH <br />ZIP SYSTEM® TAPE OR ADHESIVE <br />BACKED FLASHING. (MUST MEET <br />AC148) <br />ZIP SYSTEMS ® HARD COAT <br />STUCCO AT SLAB ON GRADE <br />These construction details are provided to assist in the installation of Zip System ® product(s) and may not apply to <br />every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details. <br />NATURAL OR MANUF — <br />STONE VENEER. <br />INSTALL IN <br />ACCORDANCE <br />WITH MANUFACTURER'S <br />RECOMMENDATIONS <br />FOUNDATION <br />DRIP EDGE FLASHING OR WEEP SCREED <br />IN ACCORDANCE WITH <br />MANUFACTURER'S <br />RECOMMENDATIONS AT BASE OF ZIP <br />SYSTEM WALL SHEATHING <br />ZIP SYSTEM® SHEATHING.* <br />LATH <br />*ZIP SYSTEM® SHEATHING IS APPROVED TO <br />REPLACE THE FIRST LAYER OF A TWO -LAYER <br />UNDERLAYMENT SYSTEM. <br />WOOD OR LT. GA. METAL STUDS <br />ONE LAYER OF WATER -RESISTIVE <br />VAPOR -PERMEABLE BARRIER WITH A <br />PERFORMANCE AT LEAST <br />EQUIVALENT TO GRADE D BUILDING <br />PAPER <br />TOP EDGE OF DRIP EDGE FLASHING <br />TAPED TO ZIP SYSTEM SHEATHING <br />SURFACE W/ ZIP SYSTEM TAPE OF <br />ADHESIVE <br />BACKED FLASHING. (MUST MEET AC148) <br />ZIP SYSTEMS ® SHEATHING w/ <br />ADHERED STONE AT SLAB ON GRADE <br />These construction details are provided to assist in the installation of Zip System ® product(s) and may not apply to <br />every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details. <br />ti p <br />U <br />° <br />cy <br />O <br />w <br />APEX -C <br />U) <br />0 <br />W <br />m <br />w <br />w <br />z <br />z <br />W <br />Q true design studios N <br />O <br />1 9000 REGENCY SQUARE BLVD. N <br />LL SUITE 100, JACKSONVILLE, FL 32211 <br />904.821.5200 <br />H =3 <br />Of c <br />O mmlwmmmmmmm <br />tL DaRsHOMON' <br />(1) <br />U � <br />R <br />O <br />1 <br />LL <br />Q <br />U <br />z 0 <br />} <br />C•� <br />O <br />J <br />O <br />z <br />2 <br />U <br />W <br />I- <br />X JW <br />a W U)Q w <br />00 z w <br />z O U) <br />O <br />Q _ <br />w = Q O <br />z w <br />o <br />o w <br />I- W W Q <br />00 W o <br />LL <br />r <br />a <br />U) <br />X <br />O ZO <br />O p <br />z w <br />_ I-_ <br />U z <br />� Abbott Park a <br />w U- <br />a LOT 027-03-1 B w <br />Q <br />_ Q <br />U <br />W <br />PROJECT NO: <br />2021.012596 z <br />DRAWN: <br />CD w <br />0 <br />CHKD: LL <br />JAC O <br />0 <br />O <br />UA <br />co <br />W <br />J <br />U <br />U) <br />U) <br />0 <br />z <br />Q <br />r <br />11-01-2021 O <br />>z <br />REVISIONS: <br />No. Description Date o <br />W <br />— LU <br />2 <br />W <br />_J <br />Q <br />U <br />U) <br />0 <br />A405 z <br />O <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.