Search
38430 Springhead Ln
Zephyrhills
>
Building Department
>
Building Plans
>
38430 Springhead Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 3:09:09 PM
Creation date
2/24/2025 10:14:34 AM
Metadata
Fields
Template:
Building Plans
Street #
38430
Location
Springhead Ln
Contractor
D R Horton
Building Plans - Permit #
3336
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 1D6EEA65-119E-4AD4-8042-DDF19178294D <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />p <br />/ p <br />D ° <br />f D <br />I D EXISTING FOUNDATION. <br />D p <br />p) D <br />ID ` <br />\ p <br />• <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOW SILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />• I <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/s' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />(ISTING FOUNDATION <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0' _0" A.F.F. SEE ARCH <br />- (MAX 20" <br />° 4 a ° a-- DEEP)' <br />/\/\4n <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL �- VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />�4 <br />-4 <br />d <br />16" VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />TOP OF FOOTING <br />v <br />N <br />I <br />L---- <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL, <br />CMU STEMWALL MONO LITHIC SLAB <br />�- <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />MIN 24" LAP <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />- OR FIBER MESH <br />U) 0 8 ° ^° ° #4OR#5 <br />O ° , ° REINFORCING PER <br />4 ° MONOLITHIC FOOTING <br />v� 4 SECTION <br />FOOTING TO BEAR ON FIRM <br />44 UNDISTURBED SOIL <br />a <br />4 °° 1 4° MIN 112" <br />\//'//' ' " <br />\\/\\/\\/\\/\\/\\\\� /��/�\>\� <br />\- • STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />•ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />LOCATE <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT IN LAST <br />REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />TOP OF SLA0 <br />VAPOR BARRIER <br />w <br />w <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />\ 0 1 a <br />U) <br />W <br />U) <br />O <br />U <br />8" CMU CHAIR <br />BLOCK W/ (1) #4 OR #5 CONT. <br />FOOTING TO BEAR ON FIRM - //�\\j \' \\ \ #6 NI ONAL BIRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F <br />(BEYOND) <br />FLOATING CONCRETE w <br />SLAB W/ 6x6 W1.4xW1.4 <br />WWF OR FIBERMESH > <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />I <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL -ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />T,STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />FINISH <br />GRADE <br />(1) #4 OR #5 CONT. <br />MINIMUM 24" <br />3VARIES PER <br />6" MAX a <br />ARCH PLANS <br />3'/z' CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />(1) #4 OR #5 90° BEND @ 48" O.C. <br />°- - <br />VAPOR BARRIER <br />12" MINTING TO BEAR ° <br />ON FIRM <br />UNDISTURBED SOIL <br />6" OPT. EXTENSION b <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />12" UNDER 1 STORY WALL W/ (2) <br />ADDITIONAL NO.4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ (3) <br />#4 OR (2) #5 CONT <br />� nl MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />*NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS 1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />- o- - - --- - - - '- <br />VAPOR BARRIER <br />o ° <br />M) <br />SEE NOTES (MAX 16") U <br />6 <br />STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" Q, <br />0 <br />N <br />E <br />MA\ O <br />U <br />ALL OTHER EXTERIOR WALL O <br />CLADDING - MIN 8", U.N.O. ON ARCH O p <br />C%j U? ° <br />X XAPES r_ <br />12"MIN \\/\\/\\/\\/\�/\� C N <br />'c <br />\ �• <br />0) <br />FOOTING TO BEAR ON 6" OPT. EXTENSION IN BRICK <br />FIRM UNDISTU SBOED LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ M <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR NO. 5 J <br />BAR IN BRICK LEDGE LL <br />16" UNDER 2 STORY WALL w/ Ld <br />(2) #5 OR (3) #4 CONTINUOUS J tds .i <br />true design studios <br />1 MONOLITHIC FOOTING SECTION z CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />FOLLOWING OCCUR: Y <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211Cn <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY 0 <br />PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />O 4- <br />r`nKlr'pGTF CI AR w/ Rvr, Cn <br />WCY <br />H Cn <br />041HOMON' <br />W Zz <br />Q.� <br />L7 <br />3 BEARING WALL FOOTING SECTION Z <br />W <br />0 <br />W <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR O This item has been electronically <br />FIBERMESH O signed and sealed by Justin M Lanier, <br />O PE on the date and/or time stamp <br />0'-0" A.F.F. shown using a digital signature. <br />SEE ARCH Printed copies of this document are <br />ot considered signed and sealed <br />DETAILS <br />° 4 °>=lby <br />nd the signature must be verified <br />4 -- a a 3rd Party Certificate Authority <br />8" MIN O n any electronic copy V,' + <br />Uj <br />8"x8" THICKENED 8" W co <br />FTG AT <br />STEP-DOWN, SEE VAPOR BARRIER z <br />PLAN <br />4 CURB STEP SECTION m LJJ O U) <br />W' <br />W Q <br />W Q O <br />8" UNDER MASONRY WALL Z <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL Z ' '�I Q Q <br />6x6 W1.4 x W1.4 WWF W 0 <br />OR FIBERMESH 1ARIESY [ 4- Q LLI <br />SEE ARCH 0 Q <br />VAPOR BARRIER <br />(MAX 16") w W <br />O x <br />x/ �\//\//\/\/� LL <br />/- Z a z <br />_ F_ <br />Lij <br />6" OPT. EXTENSION IN BRICK 0 <br />LOCATIONS ON FND PLAN CL Z <br />O a <br />ADDITIONAL NO.4 OR NO. 5 0 W <br />BAR IN BRICK LEDGE Q - <br />0 W <br />Abbott Park Q <br />5 GARAGE EXT WALL CURB SECTION _ - - <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 028-03-1 B w <br />FOLLOWING OCCUR: _ - - F- <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U Z <br />. GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY <br />PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. (n <br />PROJECT NO: LLI <br />O CI <br />CONCRETE SLAB W/ 6x6 1 2021.012597 <br />W1.4 x W1.4 WWF OR O 0 <br />FIBERMESH Z _ 0 <br />0' -0" A F.F. SEE ARCH 1:DRAWN: CD c <br />- ° <br />- - - - - (MAX 20" U - - O <br />° a ° ° -�.. _.� DEEP) Lij <br />CHKD: - 11) <br />\,\\ �\ j\\ a„ a <br />° ° <br />4" EXTENSION <br />UNDER BRICK VENEER �►►►�N' �q ���,�� <br />�C N <br />12" UNDER 1 STORY WALL Z <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m ` •°�,� s�` •.• ��� _ <br />No 85166 <br />16" UNDER 2 STORY WALL W * = < <br />w/ (3) #4 OR (2) #5 CONT Z = Docuuftned by: <br />- 13 <br />6 BEARING CURB STEP SECTION W T DAQ&43s jj, W <br />•� FS ., O R Z <br />1 TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />rHOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />it <br />O_ 11-01-2021 p <br />H W <br />U_ REVISIONS: _ <br />U_ <br />Q No. Description Date W <br />U) J <br />} - U <br />(n <br />O I-- <br />Z - - -- Z <br />0 0 <br />W <br />il- <br />x <br />W ST=2mD <br />CMU/METAL CONNECTOR ENGINEERING¢ <br />