Laserfiche WebLink
I I I I I I_L I <br />F <br />L_ <br />ALL STAIR STRINGERS <br />AND TREADS TO BE <br />#2 SYP (MIN.) <br />THREADS, RISERS, AND <br />3/4" PLYWOOD NOT <br />SHOWN IN DETAIL FOR <br />CLARITY <br />ALL WOOD TO WOOD <br />CONNECTIONS TO BE <br />GLUED (PL 200) AND <br />NAILED (MIN. (2)16d). <br />1 3/4 x 11_ <br />✓gVL <br />2x4 UNDER STRINGER - <br />GLUED AND NAILED TO <br />LANDING <br />2x4 UNDER STRINGER GLUED AND <br />NAILED TO LANDING BLOCKING <br />D <br />2x4 PT NOTCH <br />INTO STRINGER <br />Eu <br />H D <br />1-2x8 BLOCKING FOR STRAP <br />L1x4 blocking <br />20" FLAT STRAP NAILED TO RISER AND E <br />THEN WRAPPED AROUND STUD (USP <br />MTW 12) <br />PLAN VIEW <br />SCALE: " = V-0" <br />NOTE: <br />THESE DETAILS ARE NOT PLAN <br />SPECIFIC. THEY ARE PROVIDED TO <br />YOU AS A STANDARD TO CONSTRUCT <br />STAIRS. REFER TO PLAN DETAILS <br />FOR RISE AND RUN INFORMATION. <br />3/4" RISER CUT TO FIT <br />MAINTAIN BETWEEN +" <br />AND �' GAP TOP AND <br />BOTTOM, GLUED AND <br />NAILED TO STRINGER <br />2x12 TREAD <br />GLUED AND <br />NAILED <br />2x4 SPF NOSING GLUED AND <br />NAILED MATCH NOSING ON <br />OTHER TREADS <br />2x4 syp <br />blocking <br />strap (U1' <br />MT <br />OWDR FT ST P <br />2x4 PT NOTCHED INTO <br />STRINGER AND TAPCONED x8 SYP DRYWALL STOP MUST <br />INTO FLOOR WITH GLUE NOT TOUCH STRINGERS <br />STRINGER CONTACT 2x4 BLOCK IN KNEEWALL FOR 2x12 NAILING <br />POINTS x4 GLUED AND NAILED TO STRINGER <br />E FOR DRYWALL SPACING <br />H SECTION VIEW <br />SCALE: Z" = 1'-0" <br />FLOOR <br />JOIST <br />MINIM <br />SYP <br />2x8 SYP <br />2x8 <br />SYP <br />STRINGER MUST MP <br />CONTACT WITH LAN <br />2x4 CUT C. <br />DOES NOT BEAR IN <br />WALL GLUED TO <br />2x8 <br />F SECTI <br />STRINGER MUST MAKE <br />FULL CONTACT WITH LANDING <br />ALIGN <br />THIS STUD WITH <br />FACE <br />OF 2ND RISER 3/4" RISER CUT TO FIT <br />MAINTAIN BETWEEN" <br />AND 2" GAP TOP AND <br />BOTTOM, GLUED AND <br />NAILED TO STRINGER <br />2x4 BEHIND RISER <br />BLOCKING FOR <br />1x4 GLUED AND NAILED TO STRINGER STRAP GLUED TO <br />2x4 DRAFT RISER AND TREAD <br />STOP <br />x8 SYP DRYWALL STOP MUST <br />000 NOT TOUCH STRINGERS <br />i3 <br />L-2x4 SYP BLOCKING <br />PT NOTCHED INTO STRINGER FOR STRAP <br />D NAILED TO FLOOR WITH GLUE (USP MTW12) BEHIND <br />STRINGER CONTACT POINTS RISER <br />ON VIEW "A" <br />2x SYP CUT TO FIT <br />BEARS IN WALL <br />2x12 SYP BEAR <br />IN WALL <br />2x6 SYP <br />SCALE: 1" - 1'-0" <br />E <br />2x4 PT NOTCHED II\ <br />AND NAILED TO FL( <br />2x4 CUT ON BEVEL AT STRINGER CON - <br />DOES NOT BE\V <br />IN <br />WALL <br />SECTION VIEW "D" <br />SCALE: 1" = 1'-0" <br />FILLER STRIPS ADDEDrBxEARPS <br />" PLYWOOD <br />GLUED & SCREWED TO <br />PLYWOOD DECKING <br />UT TO FIT <br />N WALL <br />x12 SYP <br />BEARS IN WALL <br />BULLNOSE DETAIL <br />SCALE: 1" = T-0" <br />6TRINGER <br />2x4 GLUED <br />AND NAILED <br />SECTION D-D <br />SCALE: 1" = 1'-0" <br />3/4 PLYWOOD <br />ON DECK <br />`2x8 SYP GLUED <br />AND NAILED <br />TO <br />FRAMING <br />2x4 DRAFT <br />2x12 <br />STOP <br />TREAD <br />GLUED <br />AND <br />NAILED <br />2x4 PT NOTCHED INTO <br />STRINGER AND TAPCONED <br />INTO FLOOR WITH GLUE-Pml� <br />STRINGER CONTACT <br />POINTS <br />SECTION VIEW "B" <br />SECTION VIEW "Ell <br />x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />GLUED AND NAILED TO STRINGER <br />OR DRYWALL SPACING <br />E SECTION VIEW <br />SCALE: 2" = 1'-0" <br />3/4 PLY\A <br />ON DECK <br />'-�x8 SYF <br />AND N/ <br />FRAMII� <br />2x4 DRAF- <br />STOP <br />2x4 BLOCK <br />C <br />SCALE: 1" = 1'-0" <br />SCALE: 1" = T-0" <br />i <br />BLOCKING FOR 2x12 <br />PT UNDER 2x12 <br />-ATTACH ALL COMPONENTS <br />OF STAIR TO CONC. W/ +" X <br />2 +" TAPCONS @ MAX. 32" O.C. <br />3LUED AND NAILED TO STRINGER <br />RAFT <br />3YP DRYWALL STOP <br />T NOT TOUCH ^ <br />NGERS <br />BLOCKING FOR 2x12 <br />PT UNDER 2x12 <br />C00-� <br />2x12 SYP rSCAB 2x4 GLUED AND NAILED (EACH <br />STRINGER_ 1 SIDE) TO BOTTOM EDGE OF 2x12 <br />STRINGER <br />-"000, J�ROVIDE MOISTURE <br />PROTECTION <br />ATTACH ALL COMPONENTS <br />OF STAIR TO CONC. W/" X <br />2+" TAPCONS @ MAX. 32" O.C. <br />—1x4 GLUED AND <br />NAILED TO STRINGER <br />SECTION VIEW "C" <br />SCALE: 1" = 1'-0" <br />TOP OF <br />STRINGER <br />CONN. TO BOTT( <br />OF NEWEL POST <br />PER CONTRACT( <br />FLOOR GIRDER PROVIDE SOLID BLOCKING <br />2X4 CUT ON OR 1 J x 16" VL BELOW ALL NEWEL POST <br />BEVEL GLUED FROM JOIST TO JOIST. USE <br />AND NAILED TO 2 X 12 BLOCKS, GLUED AND <br />LVL NAILED TO JOIST. <br />NEWEL POST <br />SECTION VIEW "G <br />lv bL <br />SCALE: 1" = 1'-0" <br />OCKING <br />SCALE: 1" = 1'-0" <br />0 1 /AIM UUNO I NUU I IUIV Ur. I /AI LJ <br />(IF 11X17 REDUCE SCALE .5) SCALE: AS NOTED <br />ALL JOINT <br />✓ALL TO <br />T JOISTS) <br />FUD NAILED AND <br />) TO TOP PLATE <br />JT INTO RIM BAND, <br />) AND NAILED TO <br />NG WALL BELOW <br />ALL JOINT <br />✓ALL TO <br />R JOISTS) <br />2X <br />USP <br />u <br />_ POST LET INTO <br />-OCK <br />DE <br />JNG <br />?X8 BLOCKING <br />-OR NEWEL POST <br />1-0 ANCHOR TO. <br />GLUED AND NAILED) <br />LOOR <br />TRUSSES <br />SECTION VIEW "H" <br />SCALE: 1" = 1'-0" <br />C)CD <br />r` c <br />�d5 <br />NCO0 U <br />CO 0.) m <br />r� <br />-ico00 <br />73 <br />V1 <br />o r <br />C:, <br />ti O X t� <br />m cll <br />U) <br />a <br />V <br />a <br />a <br />f <br />F <br />3 <br />z <br />z w o E W <br />OZ <br />N�7d'�i z z <br />oaw3 <br />Zo0,S2a- <br />Q W W Vim] N Q' <br />w.- <br />`9�go � c � <br />�� 0y oxp ❑ <br />u <br />mLU <br />W 2O o� a <''N <br />w��g LLrz Cj <br />LU <br />�' <br />LU <br />v� -o�-� R11'1111i'Q <br />i \` <br />Fo7, <br />toS, LL= c3W r' QLU <br />^j <br />W'� F- X O W U 4i. <br />w U El <br />iE <br />N i%0D JN:ISG rA1 AXA\ <br />2 <br />CD <br />I..L— <br />< <br />L J <br />CO MM� <br />^ <br />I..L <br />W <br />N <br />Z3: <br />C) <br />Z <br />Z <br />z <br />O <br />W <br />Q <br />Q <br />J <br />CO <br />neo <br />W <br />I <br />U) <br />1 title: <br />0 <br />Z project no. 2017447 <br />w checked: AB/MC <br />0 <br />a <br />drawn: <br />to date: 07-27-17 <br />N scale: <br />ST <br />I <br />} <br />0 <br />0 <br />The structural design of this building is in accordance with the FLORIDA BUILDING CODE 5TH EDITION (2014) RESIDENTIAL and is certified as such. r <br />