HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC, AND <br />INSTALLED AS PER FBCR 5TH EDITION (2014) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 161 CLASS I AIR DUCT AS PER NFPA SOA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT, FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, ,SHALL BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBCR 51H EDITION (2014) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBCR 5TH EDITION <br />(2014) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBCR 5TH EDITION (2014) MECHANICAL CODE <br />SECTION 403, <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -GUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9, ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'5 LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBCR 5TH <br />EDITION (2014) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />R DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />51DE-WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />-- <br />BROKEN LINE. RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN + LIGHT <br />O/A <br />OUTSIDE AIR <br />THEW05TAT <br />m <br />PA55-THRU AIR GRILL <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />00 <br />EXTERIOR WALL <br />PLENUM - <br />T <br />y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />J <br />REFRIGERANT LINES <br />AIR HANDLER <br />EXTERIOR WALL <br />3/4' PVC CONDENSATE DRAIN LINE <br />SECURE STRAP TO CONECONC. <br />W/ (2)-3/16'X2' TAPCONS <br />CONDENSER <br />UNIT <br />5IMP50N WB ROLL STRAP <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />OR EQUAL <br />REFRIGERANT LINES TO <br />PLATFORM - <br />RETURN <br />CONDENSING UNIT <br />!�-- <br />TRAP DRAIN LINE AND TERMINATE <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ C2) <br />"8X1 1/4' SHT. MTL. SCREWS <br />IN AN DRAIN,AS PER <br />RI <br />5TPFEDITION <br />MECHANICAL BLDG. CODE <br />CONDENSER UNIT <br />SECTION 3012.1.1 <br />HVAC <br />DRAINS <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD m 12' FROM STRUCTURE <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />501L OR WASTE AS <br />1 1 REQUIRED <br />— WADE 8240-K JOSAM 56000 <br />INSIDE I I SERIES NICKEL BRASS TOP <br />CAULK ) ( P.v.0 OPTI/SPEC <br />-- - P <br />SEE <br />SITE PLAN <br />(I)FLOOR SLAB CLEAN —OUT (TYPN ) <br />TS <br />COUNTERSUNK <br />G.D. PLUG <br />7`I 8EE SPEC. <br />17 77 <br />—�� <br />—� r-e xa coNc. <br />FIN. GRADE\ <br />OR PAVING — <br />FITTING OR <br />I EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />I I <br />1 i ' <br />IN -. SEE <br />751TE PLAN <br />NEXT. GROUND CLEAN —OUT TYPN <br />FIRST FLOOR MECHANICAL PLAN <br />PROGRESSIVE AIR SYSTEMS 05/20/14 <br />A R C N I T E C T 3 <br />6 <br />Despin <br />Grou <br />41 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32760 <br />PH: 407-774-6078 <br />FAX 407.7744078 <br />www.a bdesigngroup.com <br />AA #: 0003325 <br />L4 <br />U <br />m <br />0 <br />F <br />h <br />O <br />F <br />0 <br />Sumwv. da LOTs <br />SILVERADO <br />LOT #17 <br />BLK #6 <br />PROJECT* <br />04128.000-01761 <br />HoDEL: <br />4EBB <br />1828- CALI" <br />GARAGE OWING - <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />