Search
6525 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6525 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:36:16 AM
Creation date
2/24/2025 9:56:45 AM
Metadata
Fields
Template:
Building Plans
Street #
6525
Location
Wagon Trail St
Contractor
D R Horton Inc
Building Plans - Permit #
19974
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL <br />LEGEND <br />SYMBOL <br />DEFINITION <br />NOTES <br />nSV OUTLET <br />tat N S—E POLE <br />RGT' WTLET <br />IY'N OUTLET <br />O QRLET WRED <br />r0 81111TCN <br />GFI <br />IIvv CUTLET <br />EOIIPED WC.NO FtW <br />MEIRIRER lTAHPER <br />REBIATANT TYPE( <br />a@ <br />22— OUTLET <br />W WRE Lw -T— <br />W UP <br />-i�OR <br />EXT <br />QTL"TER9GO'F <br />METili1RERT <br />UNTO. <br />6WITO41 <br />3-UTAT OF'ER <br />.Ve <br />9WIT. <br />4-WAT OPER <br />OEILMG LIGHT <br />— \O� VP <br />LXbiT Pam. <br />'o <br />RELE88FD LdN <br />MALL 6LONLE <br />PRE-WRED <br />VENT. FAN <br />I CR1 PER ffi R. <br />VENT. FAN <br />IwLXwr <br />CR'1 FER 9G. R. <br />1 <br />V Fl%T S <br />rePEcs Tev er <br />-14L w <br />OU <br />RUD RxENT <br />T � <br />FO, <br />OR <br />.�g. <br />4• rRAuc Lt3NT <br />0 <br />PANEL <br />METER <br />l • 1 SD. <br />BMLIQ DE.- <br />os/co EYIDTE DETECTOR MTER-CONBGTCD <br />Cpm 6uni CE A DISTANC <br />GF NOT LS88 TtFN 4' <br />FRon utuL <br />PENDCNT —T <br />- Ifl o�iTnT�r G�'s <br />► TELEFz108a JACK <br />� YNTER„•TER <br />Dlsca+gcr <br />_ en- AIR roNDmcTa� n <br />I 0 I u-Sox I occolmaNce uu` a Vx' <br />FLOOD LKa11T <br />OUR. -TT <br />Pa NSN-GNTTW FOR LNREB <br />•--�s�• use PGRr <br />AOTE5: <br />LOCATION OF TV JACKS 4 PHONE OUTLETS t <br />FANS TO BE VERIFIED • HOMEOWNER <br />PRE-CON5TRUCTION MEETING. <br />ALL RECEPTACLES IN ALL HABITABLE <br />ROOMS TO BE ARC FAULT PROTECTED PER <br />ELECTRICAL PROVISIONS OF F13CR 5TH <br />EDITION (2014). <br />20 AMP DEDICATED LAUNDRY CIRCUIT. <br />GFI s ISLAND (NOT ON KITCHEN CIRCUIT) <br />DISHWASHER DISCONNECT TO BE LOCKOUT <br />IN PANEL <br />BATHROOM EXHAUST FAN TO HAVE MIN. <br />CAPACITY OF 50 CFM INTERMITTENT PER <br />ELECTRICAL PROVISIONS OF SECTION <br />MI50T3 FBCR T. <br />EDITION (2014). <br />LAUNDRY ROOM RECEPTACLE SHALL BE <br />GROUND FAULT CIRCUIT -INTERRUPTER <br />PROTECTION FOR PERSONNEL ON FEEDERS <br />WIRING METHOD SHALL BE NON METALLIC <br />CABLE PER ELECTRICAL P'ROVISION5 OF <br />FBCR 5TH PER <br />(2014). <br />ALL WORK TO COMPLY WITH ELECTRICAL <br />PROVISIONS OF THE FBCR 5TH ED (2014). <br />ALL LAMP5 SHALL BE SELECTED BY <br />BUILDER AND 15% OF LIGHTING MUST BE <br />I <br />I O I <br />DINING <br />j LIVING <br />_ ROOM <br />a <br />C <br />PRE -WIRED <br />/ <br />CLG FAN <br />/ <br />/ <br />I <br />GFI <br />/ \ <br />I <br />/ \ <br />SWITCH IN / <br />I <br />CABINET / �- <br />OUTLET / <br />TO 2ND F L. <br />FOR DW / <br />/ 5TCH <br />W <br />I <br />/ <br />-- <br />1 I I <br />EN <br />T <br />\ `GFI I <br />- 1 <br />`\ <br />1 <br />\1® \ <br />1 <br />5/COS <br />REF i <br />L - - J <br />-GFI <br />I <br />I \ <br />1 <br />� <br />1 <br />I <br />PRE -WIRED // <br />� <br />CLG FAN <br />II <br />y( <br />(1 �1/� <br />FLEX <br />/ FOYER <br />j 1 <br />I GFI y{I u Ps. � <br />I CHUM 5 <br />I PORCH/� <br />I <br />/ GARAGE <br />/ DOOR <br />I <br />I <br />I <br />1 <br />KEYLESS <br />FIXTURE <br />GFI <br />GARAGE <br />DOOR <br />PREWIRE <br />GARAGE <br />/BOLLARD <br />AS REQ. <br />CONE. <br />• <br />PER BLDG. <br />CODE <br />FIELD <br />w <br />VERIFY <br />IL <br />LOC. <br />IRRIGATION <br />OUTLET - <br />48' AFF. <br />COACH <br />LIGHT <br />FIRST FLOOR ELECTRICAL PLAN <br />150 AMP ELECTRICAL RISER <br />NOT TO SCALE. <br />GENERAL NOTES: <br />A ELECTRICAL MATERIALS AND INSTALLATIONS SHALL <br />COMPLY WITH ELECTRICAL F-ROV15ION5 OF THE FBCR 5TH <br />EDITION 12014). LOCAL CODES, AND ALL LOCAL POWER <br />COMPANY REQUIREMENTS. <br />S. ALL CONDUCTORS SHALL BE TYPE TPLIN/THWN UNLESS <br />NOTED OTHERWISE. <br />POWER COMPANY <br />TRANSFORMER <br />GRADE <br />PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY - <br />ELECTRICAL SERVICE. PROVIDE 3 h COPPER (CU) IN <br />1-1/2" DIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 <br />210 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 PVC <br />CONDUIT UNLESS SERVICE 15 PROVIDED BY THE <br />ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC <br />COMPANY PRIOR TO BID. <br />1 UNIT - NEW CHART <br />LOAD CALCULATIONS ONE FAMILY <br />DWELLING WITH HEAT PUMP <br />rtgL LODE —1 <br />HOUSE PLAN: 4EHB HAYDEN MODEL <br />LOAD INFORMATION <br />VA <br />E803 SQ R GENEML IeGHTING X 9 VA Pot SY R <br />lam <br />IItCUIT AT 16 <br />TAUNDRY CIRCUIT <br />W00 <br />RANOR Ai NAPE PLATC RATING OR COOKTOP/OVEN <br />12000 <br />T NATca xuraa <br />i D�HRASNER <br />1Y00 <br />CLOTH® DRYER <br />S000 <br />I DOPOBAL <br />5m <br />t YICRORAYE <br />1800 <br />t REFRIGRRATOR <br />IE00 <br />SUBTOTAL OF GENERAL LOAD <br />3BYle <br />PBis'T IO RYA OF GENERAL (GAD AT — <br />-1. V <br />TOTAL NET GEN — Ioan83 <br />TON t[EAT PUYP (W/ 3XN EYERGENCT —T3.3 <br />k—. <br />TON COO—G SWTEYENERAL <br />TOTAL <br />TOTAL LOAD <br />30SS8 <br />CALCULATED LOAD FOR SERVICE <br />DDeae Yw/z.o r- TZR <br />150 AMP SERVICE <br />•RORST CASE SCENARIO - HTGFR4C HYAC LOAD <br />VBED POR CALCUWTIDNS.• <br />NEUTRAL CALCULATION: <br />LIGHTING, APLLIANCE, LAUNDRY LOADS: 14,283 <br />3000 vA - 1009, REMAINDER • 359. <br />NET LOAD: 6,949 <br />RANGE: 12000 * 10% 5,400 <br />DRYER: 5p00 • 10% 3500 <br />TOTAL I5)545 <br />NEUTRAL AMPACITY: 18,489 / 240 • 18 A <br />2 AL MINIMUM NEUTRAL CONDUCTOR <br />PROVIDE 32/0 CIL, THWN + Ib CU IN 2' CONDUIT OR 3 <br />•4/0 AL, THILN • 106 CU IN 2' CONDUIT. <br />(CONDUIT TO TERMINATE ABOVE SOFFIT a OVERHANG.) <br />COMBINATION SERVICE 150 AMP <br />DISCONNECT SWITCH AND 120/240 VOLT <br />M ELECTRIC METER IN I PHASE <br />NEMA 3R ENCLOSURE MLO <br />PANEL <br />150ARP <br />MCB <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdmIgngmup.com <br />AA #: 0003325 <br />F <br />Up <br />y <br />2 <br />F <br />a <br />0 <br />F <br />a <br />J <br />aulgmv. as LOT <br />SILVERADO <br />LOT #22 <br />BLK #6 <br />PROJMTA/ <br />04128.000-02261 <br />movzu <br />4EHB <br />"2605—HAYDEN" <br />GARAGE awIMG: <br />RIGHT <br />PAGE: <br />FIRST <br />FLOOR <br />ELECTRICAL <br />PLAN <br />150 MPH EXP. B <br />ARCHTECT: <br />STATE OF FLORIDA <br />J TELEPHONE SERVICE I CABLE TELEVISIOIF <br />ENTRANCE SERVICE ENTRANC <br />^ <br />EQUIPMENT EQUIPMENT <br />!UI <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW <br />VOLTAGE CONNECTIONS <br />`, // <br />OLAW A.A�CHACRA <br />AR NO 93723 <br />1 •4 CU SERVICE GROUND CONNECTED TO <br />DAR 11�8�17 <br />CONCRETE ENCASED FOOTER STEEL PER <br />mcmAr. 1/4"=1'-O" <br />ELECTRICAL PROVISIONS OF THE FBCR 5TH <br />EDITION (2014). <br />aRELRP <br />5/8" DIA X 8 FT LONG COPPER CLAD GROUND ROD <br />