My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6540 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6540 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 3:17:54 AM
Creation date
2/24/2025 9:57:55 AM
Metadata
Fields
Template:
Building Plans
Street #
6540
Location
Wagon Trail St
Contractor
D R Horton
Building Plans - Permit #
19923
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTE, <br />APPROVED BUILDING WRAP <br />SHALL BE LAPPED A MINIMUM OF 4'x4' SELF -ADHERING MEMBRANE <br />W • VERTICAL LAP" (ROLL FLASHING (COMPATIBLE W/ HOUSE <br />ENDS) , 6' • HORIZONTAL LAPS. WRAP MATERIAL) OVER 4' <br />ALL SEAMS NEED TO BE TAPED LATH VERTICAL LAP TO BE P APPROVED HOUSE WRAP. <br />WITH FORTIBER SHEATHING TAPE FLASHING TO EXTEND ONTO PIPE <br />/ I' OR LESS PIPE <br />PREFORMED CONTROL JOINT i -- �' THICK, 3 COAT CEMENT PENETRATION <br />FLANGE OF CONTROL JOINTS T \ PLASTER <br />BE WIRED TIED TO LATH • S' WRB LAYER 2, FORTIFIBER <br />OL. MAX (VERTJ. NOTE, DO BUILDING PAPER / . METAL LATH \ <br />NOT FASTEN C40NTROL JOINT TO r <br />WALL EVEN IF STUD EXISTS <br />BEYOND EXCEPT STAPLES W/ APPROVED METAL LATH <br />' LEG MAY BE USED TO TEMP. FASTENED •1' (VERTJ O.C. MAX X X. I <br />SECURE CONTROL JOINT AT SUPPORTS X X X _ _ <br />DURING INSTALLATION <br />URB LAYER'I. #5UILDIW, <br />SELF--ADHEEmw.rA MEMBRANE <br />FASTENERS TO BE SPACED BtUGCO WRAP METAL LA1HFLAauttx' S EP 7T' OL. MAX VERTICALLYWOOD SHEATHING TWRB LAYER M, ] ?NICK, 3 COAi CEMENtSTUCCO WRAP PLASTER <br />METAL LATH <br />WRB LAYER 2, FORTIFIBER <br />IFIBER PAPER �, BUILDING PAPER <br />UPS \ / LAYER STUCCO WRAP <br />INSTALL FASTENERS (CLIPS, <br />ATH SHALL NOi Gar rnN. <br />CONTINUOUS WOOD SHEATHING STRAPS, STAPLES) AS - <br />.ro a• c• ro e,II REQUIRED TO SECURE <br />H COM'ROL . * nw. '-- / N I PIPE/ WIRE TO FRAMING <br />MTS BUT SHALL \ <br />IE STOPPED AND <br />IED AT EACH SIDE. <br />PROVIDE BLOCKING <br />R ASTM CI063 <br />PLACED FLATLAT MAX. TO S' <br />�44 <br />\ <br />/ FROM CONTROL JOINTWHEN <br />CONTROL JOINT FALLS ON <br />FASTENERS FOR LATH TO BE NAILS O\R <br />i STRUCTURAL STUD <br />TAPLES IN COMPLIANCE W/ ASTM CW63 <br />. WIRE TIES TO BE (NO. 10) 0.0415' WIRE <br />I. BLOCKING SHOWN MAY BE IN ADDITIa/ \ <br />O WALL STUDS REQUIRED PER PLAN / <br />2!!�j L2t<—j <br />21 <br />O"W TYPE CONTROL <br />JOINT <br />O4 roLD eWARD • M. A O L FOLD MAARD • R. A <br />® 3. C1� . PT. D <br />I9LD <br />• A4 <br />OL FOLD NWAIPD • O t roLD Ml1AIFD . PT. A <br />R. A <br />z. CRFaa• • trt. D <br />1. CII@AG@ • n. D <br />". Cw@a9E . I'C. c <br />3. cTrfAeE • n. c <br />4. FOLD PT. C OYtR PT. <br />D TILL fR. C TOUCHES <br />eoTrda FLANGE <br />• TI PL T <br />FLANGE WIAT@R TIGM <br />SEAL FOLD, Qp <br />b �. <br />///�--�' THICK, 3 COAT CEMENT <br />PLASTER fFRAF!), vY 2 COAT <br />� PLA° (OMIT/ <br />2 PER LAP <br />SCALE, I V2'.I'-0• <br />® KICKOUT <br />DETAIL <br />BUILDIW. PAPER (FRAMtE GNLT) <br />WR S LAYER -1, <br />STUCCO IU RAP (N&ME pLy) <br />LAP LATER%CF DIIILDWG WRAP <br />avER NAILNG FLANGE, GTOP <br />OR CMJ <br />aY <br />EXTER <br />EXrf?RfOR <br />\ <br />� <br />• exe WALL FLAeHRIG <br />] b -OUT FLAMING feEE <br />ce <br />spa <br />\ 6 <br />P@LT UJD@RLAIT@M <br />�1 <br />O <br />MIFGL@ ROOFNG <br />S � <br />F�NG AµT DOTtI OMOF IBOOP 1 <br />IYYLL NTEReELT1ANe <br />DRIP EDGE. OVERLAP 9' <br />@X1END V[' DELOIU <br />M Tllw 4- , r_CNANIOALLT <br />FOL MAX. <br />A6TLN 1. <br />FA,GIA WRAP <br />WATER TIGHT DEAL (FEND OR <br />SOLDER DO NOT arts <br />VERTICAL LATH <br />& PAPER DETAIL <br />SIDE LAPS OF METAL <br />PLASTER BASES SHALL <br />BE SECURED TO <br />FRAMING MEMBERS. <br />THEY SHALL BE TIED <br />BETWEEN SUPPORTS <br />WITH 0,0415-IN. (t21-MM) <br />WIRE AT INTERVALS NOT <br />MORE THAN S' (228-MM). <br />AS PER ASTM CI063 <br />19.1. <br />FOR REPAIR OF TEARS <br />IN WRB LAYERS, TEARS <br />MAY BE PATCHED <br />W/NOUSE WRAP TAPE <br />PER MANUF. SPEC. OR <br />PEEL , STICK <br />r3-Taii <br />WOOD &TUC <br />SHEATHING <br />PAPER <br />STUCCO <br />HORIZONTAL LATH <br />& PAPER DETAIL <br />WOOD SHEATHING OR CMU <br />WR5 LAYER °I, <br />STUCCO WRAP (FRAME ONLY) <br />9' THICK, 3 COAT CEMENT <br />PLASTER (FRAME), 1/2' 2 COAT <br />CEMENT PLASTER (CMU) <br />METAL LATH (FRAME ONLY) <br />LAP WR' t TAPE OVER <br />ROOF/WALL SCREED <br />5'X5' 'L' TYPE CONTINUOUS <br />GALV, METAL FLASHING <br />(NAIL TO ROOF DECK, NOT <br />WALL SHEATHING) <br />CAP SHINGLE - DO NOT NAIL, <br />INSTALL WITH ROOF CEMENT <br />ROOF PER ELEVATIONS <br />"L" FLASHING <br />N.T.S. <br />SELF -ADHERING MEMBRANE <br />R-ASFIMG OVER APPROVED <br />HOUSE WRAP. <br />FLASHING TO EXTEND ONTO PIPE <br />—CUT AND OVERLAP ONE SIDE OF <br />���p <br />SEL—ADHERING. MEMBRANE <br />STEP 02 FLASHING <br />WRB LAYER -1, <br />STUCCO 4RAP <br />-- WRB LAYER 2, FORTIFIBER <br />BUILDING PAPER <br />— METAL LATH <br />6'xb' SELF -ADHERING MEMBRANE <br />FLASHING OVER 4'x4' <br />SELF -ADHERING MEMBRANE <br />FLASHING OVER APPROVED <br />HOUSE WRAP. <br />FLASHING TO EXTEND ONTO PIPE <br />4'x4' SELF -ADHERING MEMBRANE <br />—, FLASHING OVER APPROVED <br />HOUSE WRAP. <br />FLASHING TO EXTEND ONTO PIPE <br />�.%' CONT. BEAD OF SEALANT <br />INSTALL APPROVED HOUSEWRAP AIR <br />INFILTRATION BARRIER OVER <br />SHEATHNG <br />----ELASTOI`TERIC COATING OVER STUCCO/ <br />C.V. FINISH (SEE TYP WALL SECTION) <br />SECTION PER FBC R703.6.1 <br />90t Whlrw erd deebrin0 <br />.hWI or use of port. a cxnertl plesbr <br />,hell eo t wI0r the ep W6.1n <br />Nulrementa of ASTM C 926�12A. <br />—P Intelof exterior la endfwmirg <br />_ ,hell comply wIN ASTM C C I08312A. <br />PIPE PENET <br />3AN.T.S. <br />DRAINAGE PLANE (UJRB <br />LATER #1, STUCCO WRAP) <br />WRB LAYER *12 (FORTIFIBER ...... <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO --7 <br />WOOD SHEATHING <br />5ELF-ADHE&IVE FLASHING — — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER FBC <br />R-03.ro-1 / ASTM C-04-1-0c3, MIN, 2.5 L55. <br />PER SQ, YARD (UTILITI' OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />A R C H IT E C T S <br />GDes�n <br />rou NTro. <br />♦.wi n. rtunn,.0 rtcnunn D�vu. <br />LONGWOOD, FL 32760 <br />PH: 407-7748078 <br />FAX: 407.774-4078 <br />www.abdealgngroup'.com <br />AA S: 0003328 <br />V <br />0 <br />a <br />V <br />W <br />O <br />F <br />O <br />2IJ <br />j <br />SInSDIV. as TAT. <br />SILVERADO <br />LOT #14 <br />BLK. 6 <br />PROJWT# <br />04128.000-01461 <br />HOD�Is <br />4ENB <br />"1751—NEUVILLE" <br />GARAGE SWING: <br />RIGHT <br />PAGIC: <br />WALL <br />ASSEMBLY <br />DETAILS <br />50_MPH EXP. B <br />DP 1 17 <br />80ALM: 1 /4"=1' — 0" <br />BlEmw <br />�/UAl <br />