INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE, <br />1. BOTTOM, 2. SIDES, 3. TOP <br />X, VENT GAP 15 TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 15 TO BE <br />TOOLED 50 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />X E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />' <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, V CAULKING • JOINT <br />ALL AROUND <br />I I <br />PER FBC R703.6.1 <br />Exterior lathing and plastering <br />BACKER ROD <br />Exterior use of portland cement plaster <br />shall comply with the application <br />jrequirements <br />of ASTM C 926-12A. <br />x <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER P, <br />'I <br />STUCCO WRAP <br />,X HOODED VENT <br />THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER'4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />6 A DRYER <br />VENT (FRAME) <br />WOOD SHEATHING <br />LAYER M, <br />STUCCO WRAP <br />Y. WRB LAYER 4, FORTIF15ER <br />BUILDING PAPER <br />WOOD <br />CONSTUCTION t `,; <br />. —METAL LATH <br />9' CMU ,iv VINYL CASING BEAD <br />1^ 6' RAISED BAND <br />d X' TO )S' MID -WALL <br />WEEP SCREED <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />7C HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER "I, 5TUGG0 WRAP) <br />WRB LAYER #2 (FORTIP15ER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />5ELF-ADHE5IVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER FBC <br />R103.6.1 / ASTM C-847-09, MIN, 2.5 L55. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />W SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUR DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT m <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUR SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />�AVE/NT PENETRATION <br />SCALE: N.T.5. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />�ELEG, METER FIELD <br />VERIFY LOCATION <br />I <br />I <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CONSTRUCTION <br />WOOD SHEATHING <br />WR15 LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />PLASTER <br />Ya' TO la' MID -WALL <br />WEEP SCREED <br />1 �6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />ONTAL HORIZWEEP SCREED <br />(FRAME TO FRAME) <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />I50CYANOTE-POLY5LEND FOAM <br />')R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />:�O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />D15CONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER 01, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVEDR HOUSEWAP <br />BELOW <br />CUT SUCH THA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAX <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD SHG EATHIN <br />WRB LAYER •I, <br />STUCCO WRAP <br />WRB LAYER •2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />1/9, TEXTURED <br />FINISH WOOD <br />-FASTEN TO WOOD STRUCTURAL <br />MEMBER • Y O.C. MAX <br />K' TO1' MID -WALL <br />WEEP 5CR9ED <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />V FINISH a MASONRY <br />7B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />WRB LAYER "I, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHINGD APPLY SELF-AHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />'9 <br />STEP *'I <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />STEP #3 <br />8' <br />STEP #2 <br />WIRE, LAYER fl, <br />STUCCO WRAP <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />WRB LAYER 02, F-ORTIF15ER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />N) SECTIO <br />METAL LATH <br />STEP #5 STEP #� <br />OELECTRICAL RECEPTACLE <br />A R C N I T E C T i <br />Design <br />Grou trra. <br />T LONGWOD�D Fl.327Ei0-�� <br />PH: 404.6078 <br />FAX 401.4078 <br />www.abdesigngroup.com <br />AA N:3326 <br />w <br />rq <br />w <br />a <br />w <br />A <br />Y <br />4 <br />c, <br />v <br />I� <br />evsDiv ae LOT: <br />SILVERADO <br />LOT 24 <br />BLK 6 <br />IROJECT# <br />04128.000-02461 <br />MODEL: <br />4EHB <br />"2605—HAYDEN <br />GARAGE OWING. <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />DP 11/09/17 <br />scALE: 1/4"=1'-0" <br />giveT <br />dd T <br />A2 <br />