My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6549 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6549 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 4:04:30 AM
Creation date
2/24/2025 9:55:22 AM
Metadata
Fields
Template:
Building Plans
Street #
6549
Location
Wagon Trail St
Contractor
D R Horton Inc
Building Plans - Permit #
19586
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LEGEND <br />SYMBOL <br />DEFINITION <br />NOTES <br />I25V OUTLET <br />20 AMP 6NOLE CLE <br />IIOV OUTLET <br />HOV OUTLET <br />V7ro OwwP 01*4 0"ED <br />e <br />GPI <br />IIOV CUTLET <br />SOUPED "W v PALL <br />1ITERO:TER ]TAMPER <br />RE616TANT TTPE) <br />220V OUTLET <br />W INRE CON:CTCW <br />IS21PP <br />EXT. WATERPNDOP <br />91K)Ild7 PAULT <br />ffl <br />OUTLET <br />NTERBIPIER <br />$uTCH <br />OUATCH <br />3-WAY OPER <br />H/4 <br />6WT04 <br />4-U)AT OPER <br />L. <br />� <br />WALL MONM <br />f <br />Lg <br />CEILING LIGHT <br />VP <br />,AFORPROOP <br />\�\ <br />/O\ <br />CAN <br />�- <br />WALL SCONCE <br />PR:-WRED <br />YEW. PAN <br />I ON PER a& PT. <br />VENT. PAN <br />uo-uGMNr <br />I c0M PER ea PT. <br />ITT/T1I�T <br />V <br />PINTIMa! <br />reP[cN��TQQmp dY <br />FLU04REaCENT <br />tT <br />:.maim u6WP <br />AROUND <br />J <br />2, muoR caw <br />A' a0oRE6ClNT <br />4' TRACK LI <br />0 <br />PANEL <br />mian <br />METER <br />(D S.D. <br />W412 DETECTOR <br />WALL I ou'ImD <br />EAT. edcK-1P <br />aD. <br />SMOKE DETECTOR <br />YY.IiAB�IYBC <br />® S/CO <br />CARBON IICNCXCVI RICO DNTSCTCR <br />Ocmw <br />uTM. - <br />OUTER-COISECTED <br />MALL BE A DWTANCE <br />OP NOT LESS THIN 4• <br />PlNDAM LIGHT <br />��..11�� <br />TI/ <br />OUTLET <br />. <br />MM%4MM JACK <br />� <br />WATER 4EATER <br />TO m[ [L[VdT[D <br />DIOCCTIECT <br />AM CODRICN <br />DISCONSCT <br />N❑. <br />tEL[VNKN JACK <br />EOK RE <br />O <br />TO w SUPPORTED N <br />ACCOImANcE W wx <br />J-m <br />A6 6UCN POR <br />Wl <br />CEILNG PANA15Hf <br />TO IRS mMPP'owmv, N <br />4CC01®dNCE NIP <br />,ON <br />A6 BUCN POR <br />ROOD LIGM <br />OPT. SECLRITT <br />KeYPAD <br />PA <br />PUSH-mUTTOJ <br />POR C rm6 <br />��» <br />Dem PORT <br />LOCATION OF TV JACKS 4 PHONE OUTLETS <br />FANS TO BE VERIFIED 6 HOMEOWNER <br />PRE -CONSTRUCTION MEETING, <br />ALL RECEPTACLES M ALL HABITABLE <br />ROOMS TO BE ARC FAULT PROTECTED PER <br />ELECTRICAL PROVISIONS OF FBCR 5TH <br />EDITION <br />20 AMP DEDICATED LAUNDRY CIRCUIT. <br />GFI • ISLAND (NOT ON KITCHEN CIRCUIT) <br />DIQLe 1 SHER DISCONNECT TO BE LOCKOUT <br />IN PANEL <br />BATHROOM EXHAUST FAN TO HAVE Mlx <br />CAPACITY OF 50 CFM INTERMITTENT PER <br />ELECTRICAL PROVISIONS OF SECTION <br />MII FBCR 5TH EDITION (209). <br />LAUNDRY ROOM RECEPTACLE SHALL BE <br />GROUND FAULT CIRCUIT -INTERRUPTER <br />PROTECTION FOR PERSONNEL ON FEEDERS <br />WIRING METHOD SHALL BE NON METALLIC <br />CABLE PER ELECTRICAL PROVISIONS OF <br />FBCR 5TH ED'2014). <br />ALL WORK TO COMPLY WITH ELECTRICAL <br />PROVISIONS OF THE FBCR 5TH ED (2014). <br />ALL LAMPS SHALL BE SELECTED BY <br />E411LDER AND 15% OF LIGHTING MUST BE <br />ENERGY EFFICIENT TYPE PER FB.C. ENERGY <br />CONSERVATION (RESiDENTIAI ENERGY <br />EFFICIENCY) 2014. Sth EDITION R404.1 <br />CEILING <br />LIVING ROOM MTD. LIGHT <br />TO BE <br />INSTALLED, <br />OWNER'S PRE -WIRED WP I PROVIDE I <br />SUIT CLG FAN GFI 1 J-BOX FORI <br />T,/ OPT, FAN I <br />CLG FAN <br />\\ DINING <br />\ ROOM <br />I i I <br />1 / / <br />I ' <br />/ <br />_ _ - - -66-U ET SWITCH IN <br />FOR DW CABINET <br />------- ---- ------ <br />I � 0 i- <br />jBATH \\ GFI GFI <br />W.I.C. \\ r ---- _ �or�T: <br />---__--J \ DW ® IREF I <br />_ - SINK \ TKI KIT, <br />VP ------ r H UUN <br />DI GFI \i� PAN. <br />GFIRAWSE <br />CFI/ <br />BDRM. #4/� _v i <br />DEN -- /- <br />m I <br />/ = HOOD WIRE W/ <br />OUTLET FOR <br />\ I FUTURE MICRO <br />F'fiE-WIRED S <br />CLG PAN S/ O 3� 3 BDRM #3 <br />I- fi� I / 3C <br />IRA i PRE -WIRED <br />�� 1I / CLG FAN <br />WH 44' PB. FOR I (� <br />AFF. F / GARAGE <br />DOOR II <br />---- / - <br />COND. BOLLARD <br />O AS RBLDG.PER WALL MOUNTED�-- <br />LIGHT W/SWITCH IN <br />ATTIC I ®I BATH 20 <br />// I s/Coll <br />ll / <br />METER <br />W CLG. (I n - \\ 5 <br />VERIFYFIELOUTLET -KEYLESS \ \ <br />LOG a FIXTURE \ <br />IRRIGATION F \\ BDRM.#2 <br />OUTLET m \ <br />48' AFF. <br />GF1 GARA E ENTRY = / / CLG <br />PRE CWI�RED <br />— —------------------ III*IIRI / <br />;OACH <br />LIGHT <br />ELECTRICAL PLAN <br />150 AMP ELECTRICAL R15ER <br />NOT TO SCALE. <br />GENERAL NOTES: <br />A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL <br />COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR 5TH <br />EDITION (2014). LOCAL CODES, AND ALL LOCAL POWER <br />COMPANY REQUIREMENTS. <br />8. ALL CONDUCTORS SHALL BE TYPE THHN/THU1N UNLESS <br />NOTED OTHERWISE. <br />POWER COMPANY <br />TRANSFORMER <br />GRADE <br />PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY <br />ELECTRICAL SERVICE. PROVIDE 3 61 COPPER (CU) IN <br />1-1/2" DIA SCHEDULE 8O PVC CONDUIT OR PROVIDE 3 <br />02/0 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 PVC <br />CONDUIT UNLESS SERVICE IS PROVIDED BY THE <br />ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC <br />COMPANY PRIOR TO BID, <br />LOAD CALCULATIONS ONE FAMILY <br />DWELLING WITH HEAT PUMP <br />(NEC CODE 9D21 <br />HOUSE PLAN: MODEL <br />LOAD INFORMATION <br />VA <br />1628 94 FT GENERAL LWTT21H0 X 9 VA PER BQ R <br />5A64 <br />2 20 AYP "FLL NCE CIRCUIT' AT 1500 VA G <br />5OSO <br />1 LAUNDRY CNRCUR <br />I000 <br />I RANGE AT NA1 PLATR RATING OR COO2T'oP/OVNDN <br />12000 <br />1 wATER HEATAR <br />450E <br />1 DT6s."uER <br />1200 <br />I c1.oTN>s DRYER <br />5000 <br />1 IRCROwAVR <br />1500 <br />1 REPRIOmRATOR <br />12W <br />2UETOTAL Or 031NERAL LOAD <br />3"" <br />FIRST 10 XVA O1 OEN®UL LOAD AT 100% <br />WOOD,ENAMDRR <br />Or RG@ERAL LOAD AT 40N 25684 VA z .4 <br />10354 <br />TOTAL NET GENERAL LOAD <br />20554 <br />0.5 TON MAT PUMP IS/ 6" EMERGENCY HEAT STRIP) <br />21 Al- i 240 VA- <br />R5 TON COOLING 8YST01 40 AI@ z 240 V <br />• - <br />N17 OIDDCML LOAD <br />20954 <br />llS'T ]O'TAL NVAC <br />9600 <br />TOTAL LOAD <br />25254 <br />CALCULATED LOAD FOR SERVICE <br />2R2L4 VA/240 v- a2e Alm <br />150 AMP SERVICE <br />•woRer CASE SCENARN) - HRUGHT W.. LOAD <br />USED FOR CALCULATTOw• <br />NEUTRAL CALCULATION: <br />LIGHTING, APPLIANCE, LAUNDRY LOADS: <br />M,283 VA <br />30" vA m 100%, REMAINDER ® 35% <br />NET LOAD: <br />6,S45 VA <br />RANGE: 12000 m 10% <br />8,400 VA <br />DRYER: 5,000 m 10% <br />3500 VA <br />TOTAL <br />18,849 VA <br />NEUTRAL AAPACITY: 18,489 / 240 i 18 A <br />42 AL MINIMUM NEUTRAL CONDUCTOR. <br />PROVIDE 3-2/0 CU, THWN . 1% CU IN 2' CONDUIT OR 3 <br />04/0 AL, THU.N • 106 CU IN 2' CONDUIT. <br />(CONDUIT TO TERMINATE ABOVE SOFFIT m OVERHANG.) <br />e <br />COMBINATION SERVICE 150 AMP <br />DISCONNECT SWITCH AND 120/240 VOLT <br />ELECTRIC METER IN I PHASE <br />NEMA 3R ENCLOSURE MLO <br />PANEL <br />150A/2P <br />MCB <br />TELEPHONE SERVICE CABLE TELEVISION <br />ENTRANCE SERVICE ENTRANCE <br />EQUIPMENT EQUIPMENT <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW <br />VOLTAGE CONNECTIONS <br />1 64 CU SERVICE GROUND CONNECTED TO <br />CONCRETE ENCASED FOOTER STEEL PER <br />ELECTRICAL PROVISIONS OF THE FBCR 5TH <br />EDITION (2014). <br />5/8" DIA X 8 FT LONG COPPER CLAD GROUND ROD <br />A It C H I T E C T 3 <br />6 <br />N i; n <br />Grou Inc. <br />1441 N. RONALD REAGAN BLVD. <br />LONG WOOD, FL 32760 <br />PH:407-774.6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA 4: 0003325 <br />V <br />Oi <br />0 <br />O <br />F <br />0 <br />siJaDIV. At MAT. <br />SILVERADO <br />LOT 25 <br />BLK 6 <br />PROJMT* <br />04128.000-02561 <br />Moas� <br />4EBB <br />"1828-CALI" <br />GARAGRI OWING: <br />LEFT <br />PAGZ: <br />ELECTRICAL <br />PLAN <br />150 MPH EXP. B <br />AA0fMCTT <br />STATE OF RQflpA ' <br />P \I <br />R r <br />ROLAro AL ABOUCHACRA <br />AR NO 93723 <br />pjtnmD♦ 11/09/17 <br />OCALM 1/4"=V-0" <br />eNOW <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.