ELECTRICAL LEGEND <br />SYMBOL <br />DEFINITION <br />NOTES <br />-e <br />*111VF11 <br />a$V OUTLET <br />zo Arm 6N6LE POLE <br />110V OUTLET <br />IIOV OUTLET <br />N OF OUTLET WAED <br />TO suTCN <br />UOV OUTLET <br />amww UTAH@�DFAYRENOT)IBelerwr rrPE)220V <br />OUTLET <br />W ONE CCANECTION <br />DIin.ET <br />NTERIEFIER <br />IN&WTCH <br />1�4 <br />Lim <br />� v <br />�01\ VP <br />�O\ <br />�- <br />6UpTCN <br />3-WAY OPER <br />SWITCH <br />4-WAY OPER <br />Md WALL NMD <br />LIONT <br />�ILRIG LIbNT <br />LIONI PIEDo <br />IIIEcaaeED caJ <br />WALL SCONCE <br />FRe-uRrn <br />VENT. FAN <br />I CIFI PER sa FT. <br />PENT. P.ON <br />Ub1.IONT <br />I CRI FTIR eQ Ft. <br />2-aULD WRAP <br />AROUND <br />]_ _ � <br />2' RUOIEE6CEM <br />� _ _ _ � <br />rlcuoREeceNr <br />4' TRACK LIONT <br />0 <br />PANEL <br />Milian <br />METER <br />• 5D. <br />eMc«E DEreeroR <br />. Barr MWM <br />ALL M01MRD <br />mu FIMX-It <br />eD. <br />N10Im DETECTOR <br />W-6almm <br />NATT 6adc-Ir IW <br />DE*E.*OR <br />CMDO <br />-col v� <br />SHALL A DISTANCE <br />OF NOT LESS TEN A' <br />PENDAM Lq <br />eTT aae <br />OUTT <br />► <br />rELEPHaE JACK <br />WN <br />uaTER NlaTER <br />DISCGNECT <br />TO [fE ELEVAT® <br />I TV. <br />ICI <br />TELEVI6ION JACK <br />CE M box REQU <br />OTO <br />J <br />DE SUPPORTEDACCORDANCE N <br />SOX <br />J-1SOx <br />MANQED AS 6UG1 FOR <br />CELLNo FAN/LWNrt <br />TO C! BUPT•OR1RD N <br />A('COI®ANfE YV spx <br />HOOD LOW <br />a OP1.6EGSV2Y <br />lo>rPAD <br />PH ruw-EUTTON FOR CNSIS <br />•:-• W6a PORT <br />LOCATION OF TV JACKS 4 PHONE OUTLETS <br />FANS TO BE VERIFIED • HOMEOWNER <br />PRE -CONSTRUCTION MEETING. <br />ALL RECEPTACLES IN ALL HABITABLE <br />ROOMS TO BE ARC FAULT PROTECTED PER <br />ELECTRICAL PROVISIONS OF FBCR StI4 <br />EDITION (2014I. <br />20 AMP DEDICATED LAUNDRY CIRCUIT. <br />GFI • ISLAND (NOT ON KITCHEN CIRCUIT) <br />DISHWASHER DISCONNECT TO BE LOCKOUT <br />IN PANEL <br />BATHROOM EXHAUST FAN TO HAVE MIN. <br />CAPACITY OF 50 CFM INTERMITTENT PER <br />ELECTRICAL PROVISIONS OF SECTION <br />MI5019 FF3CR 5TH EDITION (2014). <br />LAUNDRY ROOM RECEPTACLE SHALL BE <br />GROUND FAULT CIRCUIT -INTERRUPTER <br />PROTECTION FOR PERSONNEL ON FEEDERS <br />WIRING METHOD SHALL BE NON METALLIC <br />CABLE PER ELECTRICAL PROVISIONS OF <br />�R 9TN ED 12mt4). <br />ALL WORK TO COMPLY WITH ELECTRICAL <br />PROVISIONS OF THE FBCIR 5TH ED l2014). <br />I�:j[ala::w37il7Clf-Zta�]YlC :6�.FJI1 <br />PATIO <br />--T--- <br />I <br />I � I <br />PRE-WIRED <br />GLG FAN <br />LIVII�IG <br />DROOM <br />ROOM <br />\\\ <br />PRE -WIRED <br />BEDROOM 2 <br />GLG°N <br />\ <br />\\ <br />SWITCH IN <br />CABINET I <br />AT <br />WN <br />BOLLARD <br />COND.\ <br />O <br />AS REQ. <br />PER BLDG. <br />CODE <br />aa <br />3� <br />FIELD <br />W <br />VERIFY <br />LOC. <br />d <br />IRRIGATION <br />OUTLET b <br />48' AFF. <br />GFI <br />I TO 2ND FL FOR DW / <br />5/ O SWITCH \\ 4 <br />LB <br />\ o N <br />\ I � <br />I KITCHEN <br />Tb ET_/1 <br />GFI,/ _- PAN• <br />GA AG 0 / <br />GARAGE 1 / rOPT � <br />DOOR 1 S/CO / GFI REF <br />- <br />I <br />r i <br />PRE -WIRED <br />CLG FAN <br />\\1� <br />KEYLESS I I I <br />FIXTUREFLEX <br />Ll GFI FOYER \ III <br />�lU GARAGE 1 III <br />DOOR <br />PREWIRE <br />GARAGE <br />`-------- <br />---------------- <br />L IGHT <br />W <br />1yCHIMESR II <br />PORCH <br />.--- ------- j <br />FIRST FLOOR ELECTRICAL PLAN <br />150 AMP ELECTRICAL RISER <br />NOT TO SCALE. <br />GENERAL NOTES: <br />A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL <br />COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR 5TH <br />EDITION C2014) LOCAL CODES, AND ALL LOCAL POWER <br />COMPANY REQUIREMENTS. <br />B. ALL CONDUCTORS SHALL BE TYPE THHN/TW1N UNLESS <br />NOTED OTHERWISE. <br />POWER COMPANY <br />TRANSFORMER <br />GRADE <br />PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY - <br />ELECTRICAL SERVICE. PROVIDE 3 M COPPER (CU) IN <br />1-12" CIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 <br />-2/0 ALUMINUM (AL) IN 2" DIA SCHEDULE SO PVC <br />CONDUIT UNLESS SERVICE 15 PROVIDED BY THE <br />ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC <br />COMPANY PRIOR TO BID. <br />I UNIT - NEL CHART <br />LOAD CALCULATIONS ONE FAMILY <br />DWELLING WITH HEAT PUMP <br />(NEC CODE b2) <br />HOUSE PLAN: 4EHB HAYDEN MODEL <br />LOAD INFORMATION <br />VA <br />2E06 S0 FT ORNZ2 LMHTDIG Y a VA PM Op R <br />rela <br />2 20 Al APPUARCR CIXCUTT AT — VA RA <br />0000 <br />1 LAUNDRY CIRCUIT <br />low <br />1 RANGE AT NANR PLATE RAMO OR C00%'MP/OVEN <br />12000 <br />1 wAMR HEATER <br />4500 <br />1 DIRN%AR <br />]200 <br />1 CLOTFIGT DRVRR <br />sow <br />1 Da1PORAL <br />e0O <br />1 WCRORAVR <br />loss <br />1 RRFRIORRATOR <br />1200 <br />RU OTAL OF ORNERAL WAD <br />O8215 <br />FUM 10 INA OP DEMERAL WAD AT 100% <br />lows, <br />RENAR2DRR OF GENERAL WAD AT 40% 2e215 VA 1.4 <br />m" <br />TOTAL NET GENERAL WAD <br />212as <br />&6 TON NEAT PUMP (w/ SIVI EKERORNCY REAT STRIP) <br />21 .VIP : 290 VM <br />&S TON c emo BYETRII 40 AMP 1 240 VM <br />• 9600 <br />N6T OmiRIUL WAn <br />212ea <br />NRT TOTAL HVAC <br />2eoo <br />TOTAL WAD <br />aossa <br />CALCULATED LOAD FOR SERVICE <br />30666 VA/240 V- —j22 AI@ <br />150 AMP SERVICE <br />•WORST CASE 2CRNARW - HIOWAT NVAc WAD <br />UWD FOR CALCULATIONS.• <br />NEUTRAL CALCULATION: <br />LIGHTING, APLLIANCE, LAUNDRY LOADS: 14z83 VA <br />3000 VA ® 100%, REMAINDER ® 359. <br />NET LOAD: 6,949 VA <br />RANGE: 12000 ® 10% 0,400 VA <br />DRYER: 5000 ® 10% 3500yA <br />TOTAL 15,845 VA <br />NEUTRAL AMPACITY: 16,489 / 240 • 18 A <br />02 AL MINIMUM NEUTRAL CONDUCTOR <br />PROVIDE 3A2/0 CU, THLLN . 1% CU IN 2' CONDUIT OR 3 <br />A4/0 AL, THWN . 1% CU IN 2' CONDUIT. <br />(CONDUIT TO TERMINATE ABOVE SOFFIT o OVERHANG.) <br />COMBINATION SERVICE SO AMP <br />DISCONNECT SWITCH AND 120/240 VOLT <br />M ELECTRIC METER IN I PHASE <br />NEMA 3R ENCLOSURE MLO <br />PANEL <br />150A/1P <br />MCB <br />TELEPHONE SERVICE GABLE TELEVISION <br />ENTRANCE SERVICE ENTRANCE <br />EQUIPMENT EQUIPMENT <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW <br />VOLTAGE CONNECTIONS <br />1 04 CU SERVICE GROUND CONNECTED TO <br />CONCRETE ENCASED FOOTER STEEL PER <br />ELECTRICAL PROVISIONS OF THE FBCR 57H <br />EDITION (2014). <br />5/8" CIA X 8 FT LONG COPPER CLAD GROUND ROD <br />A R C N I T E C T! <br />Group <br />1441 Ni RONALD REAGAN BLVD. <br />LONG WOOD, FL 32750 <br />FYI: 407-774.6078 <br />FAX: 407-7744078 <br />www.abdosigngroup.com <br />AA X: 0003326 <br />�y <br />0 <br />a <br />O <br />F <br />A <br />C: <br />4 <br />4 <br />OxmDrv. !a LOT. <br />SILVERADO <br />LOT #13 <br />BLK #6 <br />PIROam" <br />04128.000-01361 <br />Koa� <br />4EHB <br />"2605-HAYDEN" <br />GAVIAG» EIII <br />LEFT <br />p FIRST <br />FLOOR <br />ELECTRICAL <br />PLAN <br />150 MPH EXP. B <br />ARCHRECTJ <br />STATE OF FLORIDA <br />yl <br />DATEk 11/7/17 <br />NI 1/4"=1'-O" <br />BIT <br />8 <br />